Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Ultrasonics ; 42(1-9): 93-7, 2004 Apr.
Article in English | MEDLINE | ID: mdl-15047267

ABSTRACT

Configurations of large capacity ultrasonic complex vibration sources with multiple longitudinal transducers are proposed and studied. The ultrasonic complex vibration systems are effective and essential for new applications in various industries. The complex vibration source of 27 kHz consists of a complex transverse rod with a welding tip (aluminum alloy, stainless steel and titanium alloy), a complex vibration rod with a flange and stepped part for holding the system, a circular longitudinal vibration disk (aluminum alloy) and six bolt-clamped Langevin type PLT transducers. Three transducer pairs are driven simultaneously using three driving systems at phase difference 120 degrees, and almost circular vibration locus is obtained.

2.
Ultrasonics ; 42(1-9): 121-4, 2004 Apr.
Article in English | MEDLINE | ID: mdl-15047272

ABSTRACT

Welding characteristic of thin coated copper wires were studied using 40, 60, 100 kHz ultrasonic complex vibration welding equipments with elliptical to circular vibration locus. The complex vibration systems consisted of a longitudinal-torsional vibration converter and a driving longitudinal vibration system. Polyurethane coated copper wires of 0.036 mm outer diameter and copper plates of 0.3 mm thickness and the other dimension wires were used as welding specimens. The copper wire part is completely welded on the copper substrate and the insulated coating material is driven from welded area to outsides of the wire specimens by high frequency complex vibration.

3.
Ultrasonics ; 38(1-8): 67-71, 2000 Mar.
Article in English | MEDLINE | ID: mdl-10829631

ABSTRACT

Transverse and torsional complex vibration systems for ultrasonic seam welding of metal plate specimens, using a 27 kHz complex vibration disk welding tip vibrating in transverse and torsional vibration modes, were studied. Using a complex vibration welding system with a welding tip vibrating in elliptical or circular locus, thick plate specimens can be welded with a more uniform and larger area compared to a conventional ultrasonic welding system. The disk welding tip vibrates in an elliptical or circular locus. The complex vibration system can continuously weld multiple parts of metal plate specimens such as heat sinks with a large number of fins.

4.
Ultrasonics ; 38(1-8): 72-6, 2000 Mar.
Article in English | MEDLINE | ID: mdl-10829632

ABSTRACT

For increasing the available vibration velocity of the one-dimensional longitudinal-torsional vibration converter, a new type of complex vibration converter with multiple slitted parts installed in the positions avoiding longitudinal nodal positions along the converter for decreasing the maximum vibration stress level at the vibration nodal part was studied. The free end of the converter vibrates in an elliptical or circular locus. Complex vibration systems with elliptical to circular or rectangular to square loci can be applied effectively for various high-power applications, including ultrasonic welding of metal or plastics, ultrasonic wire bonding of IC, LSI and electronic devices, and also ultrasonic motors. The converter with multiple slitted parts was improved in the vibration stress level and the quality factor compared with the converter with single slitted part.

5.
Ultrasonics ; 38(1-8): 77-80, 2000 Mar.
Article in English | MEDLINE | ID: mdl-10829633

ABSTRACT

The vibration characteristics of longitudinal-complex transverse vibration systems with multiple resonance frequencies of 350-980 kHz for ultrasonic wire bonding of IC, LSI or electronic devices were studied. The complex vibration systems can be applied for direct welding of semiconductor tips (face-down bonding, flip-chip bonding) and packaging of electronic devices. A longitudinal-complex transverse vibration bonding system consists of a complex transverse vibration rod, two driving longitudinal transducers 7.0 mm in diameter and a transverse vibration welding tip. The vibration distributions along ceramic and stainless-steel welding tips were measured at up to 980 kHz. A high-frequency vibration system with a height of 20.7 mm and a weight of less than 15 g was obtained.

6.
Am J Sports Med ; 28(1): 47-56, 2000.
Article in English | MEDLINE | ID: mdl-10653543

ABSTRACT

An experimental study was performed in 32 adult beagle dogs to clarify the effect of nonphysiologically high initial tension on the mechanical and histologic properties of in situ frozen anterior cruciate ligaments. Both anterior cruciate ligaments in each dog underwent the in situ freeze-thaw treatment. The tibial insertion of the ligament was then made free from the tibia along with a cylindrical bone block. In the right knee, an initial tension of 20 N was applied on the anterior cruciate ligament by translocating the bone block in the distal direction. In the left knee, this bone block was anatomically reduced. Each bone block was firmly fixed with an interference screw. Ten animals were sacrificed at 6 weeks and 10 at 12 weeks. The tensile strength and the tangent modulus in the highly tensioned knee were significantly less than those in the physiologically tensioned knee at 12 weeks. Histologically, cell nuclei appeared to be spindle-shaped in the physiologically tensioned knee, while oval nuclei and focal degenerative changes with a number of vacuoles were occasionally found in the matrix in the highly tensioned knee. This study demonstrated that a nonphysiologically high tension significantly deteriorates the mechanical properties of the in situ frozen anterior cruciate ligament compared with physiologic tension.


Subject(s)
Anterior Cruciate Ligament/physiology , Cryopreservation , Knee Joint/physiology , Animals , Anterior Cruciate Ligament/pathology , Biomechanical Phenomena , Dogs , Male , Stress, Mechanical , Tibia/physiology
7.
Am J Sports Med ; 25(1): 99-106, 1997.
Article in English | MEDLINE | ID: mdl-9006702

ABSTRACT

We conducted a prospective, randomized, short-term study to clarify the effects of initial graft tension on clinical outcome after arthroscopically assisted anterior cruciate ligament reconstruction with autogenous doubled semitendinosus and gracilis tendons connected in series with polyester tapes. Seventy Japanese patients with chronic, "isolated" anterior cruciate ligament tears were entered in the study. The patients were randomly divided into three groups based on initial graft tension: Group 1 (20 N), Group 2 (40 N), or Group 3 (80 N). No statistical differences were noted among the three groups with regard to their background factors. The patients were observed for 2 years or more after surgery. Postoperatively, the average side-to-side difference in anterior laxity was 2.2 +/- 2.4 mm in Group 1, 1.4 +/- 1.8 mm in Group 2, and 0.6 +/- 1.7 mm in Group 3. Analysis of variance testing showed that the postoperative laxity in Group 3 was significantly less than that in Group 1. Spearman's rank-order correlation analysis also demonstrated significant correlation between the magnitude of initial graft tension and the magnitude of the postoperative laxity. This study demonstrates that relatively high initial tension (up to 80 N) reduces the postoperative anterior laxity of the knee joint after anterior cruciate ligament reconstruction using the doubled autogenous hamstring tendons connected in series with polyester tapes.


Subject(s)
Anterior Cruciate Ligament Injuries , Anterior Cruciate Ligament/surgery , Knee Injuries/surgery , Tendons/transplantation , Adult , Female , Humans , Joint Instability/prevention & control , Knee Injuries/rehabilitation , Male , Prospective Studies , Rupture , Treatment Outcome
8.
Am J Sports Med ; 23(6): 706-14, 1995.
Article in English | MEDLINE | ID: mdl-8600739

ABSTRACT

To distinguish between morbidity caused by harvesting semitendinosus and gracilis tendons and morbidity associated with anterior cruciate ligament reconstruction surgery, we performed a prospective randomized study using 65 patients who underwent anterior cruciate ligament reconstruction using these tendons. The patients underwent either contralateral (N = 34) or ipsilateral (N = 31) graft harvest. For the nonoperated knees in the ipsilateral harvest group, isometric and isokinetic strength of the quadriceps and hamstring muscles increased to approximately 120% of the preoperative value at 12 months after surgery. Compared with these knees, the tendon harvest did not affect quadriceps muscle strength at all. However, harvest did decrease hamstring muscles strength for 9 months after surgery. The graft harvest in the knees with anterior cruciate ligament reconstruction also did not significantly affect quadriceps muscle strength, but it did significantly decrease hamstring muscles strength only at 1 month. Activity-related soreness at the donor site was rarely restricting and resolved by 3 months. This study demonstrated that the semitendinosus and gracilis tendon graft is a reasonable choice to minimize the donor site morbidity in ligament reconstruction using autografts.


Subject(s)
Anterior Cruciate Ligament Injuries , Anterior Cruciate Ligament/surgery , Muscle, Skeletal/surgery , Tendons/transplantation , Activities of Daily Living , Adult , Female , Humans , Isometric Contraction , Knee Injuries/rehabilitation , Knee Injuries/surgery , Knee Joint/physiopathology , Male , Muscle Contraction , Muscle, Skeletal/physiopathology , Pain, Postoperative/physiopathology , Patient Satisfaction , Postoperative Care , Prospective Studies , Range of Motion, Articular , Sports/physiology , Transplantation, Autologous
SELECTION OF CITATIONS
SEARCH DETAIL
...