Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Radiat Res ; 58(6): 840-848, 2017 Nov 01.
Article in English | MEDLINE | ID: mdl-28339740

ABSTRACT

Carbon-ion therapy by layer-stacking irradiation for static targets has been practised in clinical treatments. In order to apply this technique to a moving target, disturbances of carbon-ion dose distributions due to respiratory motion have been studied based on the measurement using a respiratory motion phantom, and the margin estimation given by the square root of the summation Internal margin2+Setup margin2 has been assessed. We assessed the volume in which the variation in the ratio of the dose for a target moving due to respiration relative to the dose for a static target was within 5%. The margins were insufficient for use with layer-stacking irradiation of a moving target, and an additional margin was required. The lateral movement of a target converts to the range variation, as the thickness of the range compensator changes with the movement of the target. Although the additional margin changes according to the shape of the ridge filter, dose uniformity of 5% can be achieved for a spherical target 93 mm in diameter when the upward range variation is limited to 5 mm and the additional margin of 2.5 mm is applied in case of our ridge filter. Dose uniformity in a clinical target largely depends on the shape of the mini-peak as well as on the bolus shape. We have shown the relationship between range variation and dose uniformity. In actual therapy, the upper limit of target movement should be considered by assessing the bolus shape.


Subject(s)
Heavy Ion Radiotherapy , Motion , Respiration , Dose-Response Relationship, Radiation , Phantoms, Imaging
2.
J Radiat Res ; 53(2): 272-80, 2012.
Article in English | MEDLINE | ID: mdl-22129564

ABSTRACT

Intensity-modulated proton therapy (IMPT) is expected to improve treatment results with fewer side effects than other proton therapies. The purpose of this study was to evaluate the tumor sites for which IMPT was effective under the same beam calculation conditions by planning IMPT for typical cases treated with passive scattering proton therapy (PSPT). We selected 16 cases of nasal cavity, lung, liver or prostate cancers as typical tumor sites receiving PSPT. The dose distributions and dose volume histograms optimized by the IMPT were compared with those optimized by the PSPT. We took particular note of the doses to the skin and organs at risk (OAR) when PSPT was replaced by IMPT. Furthermore, an improvement of the beam angles was also performed to obtain better dose distributions in the IMPT. The IMPT with the same beam angles resulted in near-maximum doses to the skin of average 78%, 64%, 84% and 99% of the PSPT doses for nasal cavity, lung, liver, and prostate cancers, respectively. However, it was difficult to improve the dose homogeneity of the target volume. The change of the IMPT beam angles could reduce the doses to OARs and skin in the case of the nasal cavity, while it had limited effect in the other cases. We concluded that IMPT was effective for reducing the doses to some OARs when treating nasal cavity, lung, liver and prostate cancers. The selection of beam angles was important in the IMPT optimization, especially for nasal cavity cancers.


Subject(s)
Models, Biological , Neoplasms/radiotherapy , Organs at Risk/radiation effects , Radiation Injuries/etiology , Radiation Injuries/prevention & control , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Conformal/methods , Computer Simulation , Female , Humans , Neoplasms/complications , Proton Therapy , Protons/adverse effects , Radiotherapy Dosage , Scattering, Radiation , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...