1.
Urology ; 126: e3-e4, 2019 04.
Article in English | MEDLINE | ID: mdl-30707965

ABSTRACT

A 35-year-old male of 165 cm height and weight of 65 kg, had a suprapubic catheter indwelling for 4 years without replacement for urethral stricture. The catheter became gradually obstructed, and urine leaked out around the suprapubic catheter. A lumbar abdominal distension, an inferior abdominal mass and renal failure prompted him to seek medical attention in our hospital in September 2018. This clinical case is hereby presented from 3 aspects of imaging, lab examination, and operation.


Subject(s)
Catheters, Indwelling , Urethral Stricture/therapy , Urinary Catheters , Adult , Device Removal , Equipment Failure , Humans , Male , Time Factors