Int J Radiat Oncol Biol Phys ; 76(2): 548-56, 2010 Feb 01.
Article in English | MEDLINE | ID: mdl-20117290

ABSTRACT

PURPOSE: Optimal implementation of new radiotherapy techniques requires accurate predictive models for normal tissue complications. Since clinically used dose distributions are nonuniform, local tissue damage needs to be measured and related to local tissue dose. In lung, radiation-induced damage results in density changes that have been measured by computed tomography (CT) imaging noninvasively, but not yet on a localized scale. Therefore, the aim of the present study was to develop a method for quantification of local radiation-induced lung tissue damage using CT. METHODS AND MATERIALS: CT images of the thorax were made 8 and 26 weeks after irradiation of 100%, 75%, 50%, and 25% lung volume of rats. Local lung tissue structure (S(L)) was quantified from local mean and local standard deviation of the CT density in Hounsfield units in 1-mm(3) subvolumes. The relation of changes in S(L) (DeltaS(L)) to histologic changes and breathing rate was investigated. Feasibility for clinical application was tested by applying the method to CT images of a patient with non-small-cell lung carcinoma and investigating the local dose-effect relationship of DeltaS(L). RESULTS: In rats, a clear dose-response relationship of DeltaS(L) was observed at different time points after radiation. Furthermore, DeltaS(L) correlated strongly to histologic endpoints (infiltrates and inflammatory cells) and breathing rate. In the patient, progressive local dose-dependent increases in DeltaS(L) were observed. CONCLUSION: We developed a method to quantify local radiation-induced tissue damage in the lung using CT. This method can be used in the development of more accurate predictive models for normal tissue complications.


Subject(s)
Lung/radiation effects , Radiation Injuries, Experimental/diagnostic imaging , Tomography, X-Ray Computed , Animals , Carcinoma, Non-Small-Cell Lung/radiotherapy , Dose-Response Relationship, Radiation , Feasibility Studies , Humans , Lung/diagnostic imaging , Lung/pathology , Lung/physiopathology , Lung Neoplasms/radiotherapy , Male , Radiation Dosage , Radiation Injuries, Experimental/pathology , Rats , Rats, Wistar , Respiratory Rate
2.
Eur Radiol ; 15(5): 995-1007, 2005 May.
Article in English | MEDLINE | ID: mdl-15776244

ABSTRACT

Acquisition time plays a key role in the quality of cardiac multidetector computed tomography (MDCT) and is directly related to the rotation time of the scanner. The purpose of this study is to examine the influence of heart rate and a multisector reconstruction algorithm on the image quality of coronary arteries of an anthropomorphic adjustable moving heart phantom on an ECG-gated MDCT unit. The heart phantom and a coronary artery phantom were used on a MDCT unit with a rotation time of 500 ms. The movement of the heart was determined by analysis of the images taken at different phases. The results indicate that the movement of the coronary arteries on the heart phantom is comparable to that in a clinical setting. The influence of the heart rate on image quality and artifacts was determined by analysis of several heart rates between 40 and 80 bpm where the movement of the heart was synchronized using a retrospective ECG-gated acquisition protocol. The resulting reformatted volume rendering images of the moving heart and the coronary arteries were qualitatively compared as a result of the heart rate. The evaluation was performed on three independent series by two independent radiologists for the image quality of the coronary arteries and the presence of artifacts. The evaluation shows that at heart rates above 50 bpm the influence of motion artifacts in the coronary arteries becomes apparent. In addition the influence of a dedicated multisector reconstruction technique on image quality was determined. The results show that the image quality of the coronary arteries is not only related to the heart rate and that the influence of the multisector reconstruction technique becomes significant above 70 bpm. Therefore, this study proves that from the actual acquisition time per heart cycle one cannot determine an actual acquisition time, but only a mathematical acquisition time.


Subject(s)
Heart/diagnostic imaging , Models, Cardiovascular , Tomography, X-Ray Computed/methods , Algorithms , Artifacts , Electrocardiography , Heart Rate/physiology , Humans , Motion , Phantoms, Imaging , Physical Phenomena , Physics , Time Factors