1.
J Magn Reson Imaging ; 51(4): 1192-1199, 2020 04.
Article in English | MEDLINE | ID: mdl-31515878

ABSTRACT

BACKGROUND: Quantitative susceptibility mapping (QSM) and dynamic contrast-enhanced quantitative permeability (DCEQP) on magnetic resonance (MR) have been shown to correlate with neurovascular disease progression as markers of vascular leakage and hemosiderin deposition. Applying these techniques as monitoring biomarkers in clinical trials will be necessary; however, their validation across multiple MR platforms and institutions has not been rigorously verified. PURPOSE: To validate quantitative measurement of MR biomarkers on multiple instruments at different institutions. STUDY TYPE: Phantom validation between platforms and institutions. PHANTOM MODEL: T1 /susceptibility phantom, two-compartment dynamic flow phantom. FIELD STRENGTH/SEQUENCE: 3T/QSM, T1 mapping, dynamic 2D SPGR. ASSESSMENT: Philips Ingenia, Siemens Prisma, and Siemens Skyra at three different institutions were assessed. A QSM phantom with concentrations of gadolinium, corresponding to magnetic susceptibilities of 0, 0.1, 0.2, 0.4, and 0.8 ppm was assayed. DCEQP was assessed by measuring a MultiHance bolus as the consistency of the width ratio of the curves at the input and outputs over a range of flow ratios between outputs. STATISTICAL TESTS: Each biomarker was assessed by measures of accuracy (Pearson correlation), precision (paired t-test between repeated measurements), and reproducibility (analysis of covariance [ANCOVA] between instruments). RESULTS: QSM accuracy of r2 > 0.997 on all three platforms was measured. Precision (P = 0.66 Achieva, P = 0.76 Prisma, P = 0.69 Skyra) and reproducibility (P = 0.89) were good. T1 mapping of accuracy was r2 > 0.98. No significant difference between width ratio regression slopes at site 2 (P = 0.669) or site 3 (P = 0.305), and no significant difference between width ratio regression slopes between sites was detected by ANCOVA (P = 0.48). DATA CONCLUSION: The phantom performed as expected and determined that MR measures of QSM and DCEQP are accurate and consistent across repeated measurements and between platforms. LEVEL OF EVIDENCE: 1 Technical Efficacy Stage: 2 J. Magn. Reson. Imaging 2020;51:1192-1199.


Subject(s)
Image Processing, Computer-Assisted , Magnetic Resonance Imaging , Magnetic Resonance Spectroscopy , Permeability , Phantoms, Imaging , Reproducibility of Results
2.
Magn Reson Med ; 70(2): 413-9, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23042669

ABSTRACT

This work presents a new class of three-dimensional spiral based-trajectories for sampling magnetic resonance data. The distributed spirals trajectory efficiently traverses a cylinder or sphere or intermediate shape in k-space. The trajectory is shown to be nearly as efficient as a conventional stack of spirals trajectory in terms of scan time and signal-to-noise ratio, while reducing coherent aliasing in all three spatial directions and reducing Gibbs ringing due to the nature of collecting data from a sphere in k-space. The trajectory uses a single two-dimensional spiral waveform with the addition of a single orthogonal waveform which is scaled with each repetition, making it relatively easy to implement. Blurring from off-resonance only occurs in two dimensions due to the temporal nature of the sampling.


Subject(s)
Algorithms , Brain/anatomy & histology , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Humans , Reproducibility of Results , Sensitivity and Specificity