Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 24
Filter
Add more filters










Publication year range
1.
Oper Dent ; 49(2): 222-230, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38349820

ABSTRACT

The aim of this study was to evaluate the push-out bond strength and the failure mode of single adjustable posts (SPLENDOR SAP), anatomical posts (AP), or computer-aided design/computer-aided manufacturing (CAD-CAM) posts cemented to flared root canal dentin with self-adhesive dual-cure resin cement. Thirty single-rooted premolars received endodontic treatment with gutta-percha and a calcium hydroxide-based endodontic cement. After 24 hours, the canal spaces were enlarged with burs. The tooth specimens were divided equally into three groups (n=10), according to the glass fiber post (GFP) system: AP-prefabricated GFP (Reforpost #2, Angelus) was relined with composite resin (Filtek Z350 XT, 3M ESPE); SPLENDOR SAP-GFP was used with a glass fiber sleeve to adjust the adaptation (Splendor SAP, Angelus); and CAD-CAM-a resin pattern was obtained and scanned to produce a CAD-CAM GFP (Fiber CAD Lab, Angelus) milled using a subtractive technique. The three GFP systems were cemented with self-adhesive resin cement (Rely X U200, 3M ESPE). The roots were fixed to an acrylic resin plate used to section them into specimens of cervical, middle, and apical thirds. Then, the slices were attached to a universal testing machine to perform the push- out test at a speed of 0.5 mm/min and a load of 50 Kgf. The posttest specimens were examined under a stereoscopic microscope to evaluate the failure mode. The bond strength variable was analyzed using a generalized linear model, following a split-plot design. Failure mode analysis was performed using Fisher exact test. The significance level adopted was 5%. There was no significant difference among the GFP systems or among the thirds, in terms of bond strength (p>0.05), nor was there any significant association between the systems and the failure mode (p>0.05). Most specimens presented mixed or adhesive failure between resin cement and dentin. It was concluded that the bond strength to flared root dentin was not influenced by the GFP system or the root third.


Subject(s)
Dental Bonding , Post and Core Technique , Resin Cements/therapeutic use , Dental Bonding/methods , Dental Pulp Cavity , Dental Cements , Glass , Materials Testing , Dentin
2.
Oper Dent ; 49(1): 52-64, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38019213

ABSTRACT

The present study aimed to evaluate the influence of application mode on the short-term microshear bond strength longevity of self-etching and universal adhesive systems to enamel, the failure mode, and the resulting enamel surface micromorphology. Ninety enamel surfaces were obtained from sound third molars, planed, and randomly assigned to nine groups, according to the application mode and the adhesive system (n=10). There were three primer application modes: according to the manufacturer's recommended application time (control), using double the application time recommended for the primer and selective enamel etching. The adhesive systems used were: Clearfil SE Bond (Kuraray), FL-Bond II (SHOFU), and Futurabond U (Voco). At least two resin-bonded composite cylinders (Grandioso Light Flow, Voco) were placed on each enamel surface, and then evaluated for microshear bond strength at 24 hours and 180 days of storage in solution body fluid (SBF) at pH 7.4. Failure modes were evaluated with a stereoscopic microscope at 20× magnification. A micromorphological analysis of the enamel surface was performed under a scanning electron microscope at 5000× magnification before and after the treatments. Mixed models for repeated measures over time showed significant interaction among application modes, adhesive systems, and time periods (p=0.0331). The bond strength of FL-Bond II adhesive to enamel observed after performing selective enamel etching was significantly higher than that observed after applying the control treatment (p=0.0010) at both 24 hours and 180 days. However, no significant difference was observed between the application of this same adhesive at double the time recommended by the manufacturer and the other two application modes (p>0.05). There was also no significant difference in the microshear bond strength for the enamel treatments applied using Clearfil SE Bond and Futurabond U (p>0.05). A significant reduction in bond strength to enamel was observed at the 180-day storage time for all the adhesive systems when selective enamel etching was performed (p<0.0001). No significant association was observed between the adhesive system failure mode and the enamel treatments (p=0.1402 and p=0.7590 for 24 hours and 180 days, respectively). The most prevalent failure was the adhesive type.


Subject(s)
Dental Bonding , Dental Cements , Dental Cements/chemistry , Dental Bonding/methods , Acid Etching, Dental/methods , Composite Resins/chemistry , Resin Cements/therapeutic use , Resin Cements/chemistry , Dental Enamel , Materials Testing , Shear Strength , Dentin-Bonding Agents/chemistry
3.
Oper Dent ; 48(6): 720-731, 2023 Nov 01.
Article in English | MEDLINE | ID: mdl-37881067

ABSTRACT

OBJECTIVE: To evaluate the effects of commercial mouth rinses on color, roughness, sorption (SR), and solubility (SL) of resin composites. METHODS AND MATERIALS: Disc-shaped specimens (stage I: 6 mm × 2 mm; stage II: 10 mm × 1.5 mm) were made from the following resin composites (n=10): conventional nanofilled (Filtek Z350XT, 3M Oral Care), conventional nanohybrid (Luna, SDI), bulk-fill nanofilled (Filtek One Bulk-Fill, 3M Oral Care), and bulk-fill nanohybrid (Aura Bulk-Fill, SDI) exposed to distilled water (control), blue mouth rinse without alcohol (Colgate Total 12 Clean Mint, Colgate-Palmolive), or blue mouth rinse with alcohol and essential oil (Listerine Tartar Control, Johnson & Johnson). In stage I, tests were performed at the baseline, and after the immersion in solution time points to evaluate coordinates of the CIEL*a*b* system (ΔL*, Δa*, Δb*), general color change (ΔEab, ΔE00, and ΔSGU), and surface roughness (Ra). In stage II, SR and SL were evaluated (ISO 4049:2019) after immersion in the solutions for 7 days. The results were evaluated by generalized linear models (Ra, SR), Kruskal-Wallis, and Dunn tests (color, SL), with α = 0.05. RESULTS: There were no significative differences for Ra between the solutions. Both mouth rinses promoted significantly negative ΔL* (Luna), Δa* (Filtek One Bulk-fill), and Δb* (all materials except conventional nanofilled resin composite). Mouth rinse without alcohol promoted significantly negative Δa* on all resin composites tested. Both mouth rinses promoted higher ΔEab and ΔE00 for bulk-fill resin composites compared to control. Mouth rinse with alcohol caused higher ΔSGU for bulk-fill nanofilled resin composite. It also promoted greater SR in all the resin composites compared with mouth rinse without alcohol and higher SR in nanohybrid resin composites compared with control. Both mouth rinses promoted higher SL values in Luna and differed significantly from control. CONCLUSIONS: The physical properties were manufacturer dependent and mediated by mouth rinses. The mouth rinses promoted color changes in the resin composites, pointing out that bulk-fill resin composites were more affected by these effects, especially when the mouth rinse contained essential oil and alcohol.


Subject(s)
Mouthwashes , Oils, Volatile , Mouthwashes/pharmacology , Composite Resins , Ethanol , Solubility , Materials Testing , Surface Properties
4.
Oper Dent ; 48(6): 677-688, 2023 Nov 01.
Article in English | MEDLINE | ID: mdl-37881103

ABSTRACT

OBJECTIVE: To evaluate the flexural strength of two types of high-viscosity resin composites (conventional or bulk-fill) that were repaired with either high-viscosity composites (conventional or bulk-fill) or low-viscosity composites (conventional or bulk-fill) of the same manufacturer (3M Oral Care, St Paul, MN, USA). METHODS AND MATERIALS: Specimens (25 mm × 2 mm × 2 mm) of both conventional nanofilled resin (Filtek Z350XT), and bulk-fill nanofilled resin (Filtek One Bulk Fill) were prepared. After fracture of the specimens in the 3-point bending test (initial), half of the specimens were repaired immediately afterwards (24 hours), and the other half were repaired after 6 months of storage in distilled water. Repairs were performed with (n=15) high-viscosity resin composites (Filtek Z350XT, Filtek One Bulk Fill), or their low-viscosity versions (Filtek Supreme XT Flow, Filtek Bulk Fill Flowable Restorative). The repair was performed by roughening the surface and applying phosphoric acid, silane, and adhesive. The bending test (results reported in MPa) was performed in a universal testing machine, and the fracture pattern was determined. Data were evaluated by generalized linear models, chi-square test and the Fisher exact test (α=0.05). RESULTS: There was no significant difference between the former pair of high-viscosity resins in terms of initial flexural strength (p=0.42). The repairs performed with low-viscosity resin composites after 24 hours or 6 months obtained higher MPa values compared with those using high-viscosity composites (p=0.0006). There was a significant decrease in MPa values when the repair was performed after 24 hours and an increase after 6 months, regardless of the material (p<0.0001). After 6 months, fractures involving the old (conventional) resin were more frequent in the repair performed with bulk-fill resin composites compared with the conventional composites (p=0.02). CONCLUSIONS: Considering the tested products, the material to be repaired did not influence the flexural strength of the repair composite; however, the use of the low-viscosity resin composites resulted in greater flexural strength of the repaired material. The repair of the aged composite resulted in an increase in its flexural strength, regardless of the material repaired or used to perform the repair.


Subject(s)
Dental Materials , Flexural Strength , Viscosity , Materials Testing , Composite Resins/therapeutic use
5.
Oper Dent ; 48(5): E95-E105, 2023 Sep 01.
Article in English | MEDLINE | ID: mdl-37503688

ABSTRACT

This study evaluated dentin enzymatic degradation based on the total matrix metalloproteinase (MMP) activity of demineralized dentin matrices before and after exposure to phosphoric acid (PA), glycolic acid (GA), and ferulic acid (FA). The release of hydroxyproline (HP), ultimate tensile strength (UTS), and dentin permeability (DP) were also evaluated. Dentin collagen matrices were assessed according to total MMP activity before and after treatment with the tested acids (n=10) for 15 seconds and compared with the control (GM6001 inhibitor). Dentin beams were analyzed for HP release and UTS after the treatments. Dentin discs were tested for DP at a pressure of 5 psi before and after treatment with the acids (n=10). The FA group had a lower percentage of enzymatic inhibition than the PA and GA groups (p<0.0001). No significant difference in UTS was found among the acids (p=0.6824), but HP release was significantly higher in the FA group than in the PA and GA groups (p<0.0001). No significant difference in DP was found for the acids (p=0.0535). GA led to less activation of MMPs and less release of HP, whereas the UTS and DP for GA were like those found for PA. In contrast, FA promoted greater enzymatic activity and greater release of HP, while having similar results to GA and PA regarding mechanical properties.


Subject(s)
Dentin , Glycols , Glycols/metabolism , Tensile Strength , Phosphoric Acids/pharmacology , Permeability
6.
Oper Dent ; 48(2): E35-E47, 2023 Mar 01.
Article in English | MEDLINE | ID: mdl-36656318

ABSTRACT

This study evaluated the etching pattern, surface microhardness, and bond strength for enamel and dentin submitted to treatment with phosphoric, glycolic, and ferulic acids. Enamel and dentin blocks were treated with phosphoric, glycolic, and ferulic acid to evaluate the surface and adhesive interface by scanning electron microscopy (2000×). Surface microhardness (Knoop) was evaluated before and after etching, and microtensile bond strength was evaluated after application of a two-step adhesive system (Adper Single Bond 2, 3M ESPE) at 24 hours and 12 months storage time points. Analysis of variance (ANOVA) and Tukey's test showed a decrease in the microhardness values for both substrates after application of each acid (p<0.0001). The reduction percentage was significantly higher for enamel treated with phosphoric acid (59.9%) and glycolic acid (65.1%) than for ferulic acid (16.5%) (p<0.0001), and higher for dentin that received phosphoric acid (38.3%) versus glycolic acid (27.8%) and ferulic acid (21.9%) (p<0.0001). Phosphoric and glycolic acids led to homogeneous enamel demineralization, and promoted the opening of dentinal tubules, whereas ferulic acid led to enamel surface demineralization and partially removed the smear layer. The adhesive-enamel interface showed micromechanical embedding of the adhesive in the interprismatic spaces when phosphoric and glycolic acids were applied. Ferulic acid showed no tag formation. Microtensile bond strength at both time points, and for both substrates, was lower with ferulic acid (p=0.0003/E; p=0.0011/D; Kruskal Wallis and Dunn). The bond strength for enamel and dentin decreased when using phosphoric and glycolic acids at the 12-month time evaluation (p<0.05). Glycolic acid showed an etching pattern and microhardness similar to that of phosphoric acid. Ferulic acid was not effective in etching the enamel or dentin, and it did not provide satisfactory bond strength to dental substrates.


Subject(s)
Dental Bonding , Tooth Demineralization , Humans , Glycols/analysis , Surface Properties , Phosphoric Acids , Dental Enamel/chemistry , Dentin/chemistry , Tooth Demineralization/chemically induced , Tensile Strength , Dentin-Bonding Agents/chemistry , Resin Cements/chemistry
7.
Oper Dent ; 47(2): 173-182, 2022 Mar 01.
Article in English | MEDLINE | ID: mdl-35604820

ABSTRACT

OBJECTIVES: The aim of this study was to evaluate the effect of different surface treatments and thermocycling (TC) on the push-out bond strength of two brands of glass fiber posts (GFPs) to composite resin. METHODS: White Post DC (WP) (FGM Dental Group International, Joinville, Santa Catarina, BR) and Exacto (EC) (Angelus, Clinical Research Dental, Londrina, PR, Brazil). GFPs were cleaned with 70% alcohol and divided into five groups, according to the surface treatment (n=15): control (C), without treatment; prehydrolyzed silane (S-pre) (Prosil, FGM Dental Group International); 37% phosphoric acid + prehydrolyzed silane (AcS-pre); Scotchbond Universal Adhesive System (AdU), 3M Oral Care; two-bottle silane (S2B) (Dentsply Sirona Inc). The composite resin was inserted around the posts by using a split matrix. The samples were cut into 1-mm slices. Half of the samples were subjected to the push-out test immediately, and the other half underwent TC before the test. After failure analysis, the data were submitted to three-way analysis of variance (ANOVA) (α=0.05). RESULTS: EC achieved higher bond strength than WP, regardless of TC (p<0.05). Regarding WP, surface treatments (p<0.001) and TC (p<0.001) influenced bonding strength. As for EC without TC, the highest bond strength (p<0.05) was found for C, then AcSpre, S-pre, AdU, and S2B. Application of TC resulted in a statistically higher bond strength values for the EC AcS-pre group (p<0.05), followed by S2B, S-pre, C, and AdU. The WP failures were predominantly cohesive, similar to the EC AdU and EC S2B groups. The other EC groups showed mostly mixed failures. CONCLUSIONS: Surface treatment and TC affected the bond strength to composite resin, depending on which post was used. It is important for dentists to understand the effects of different types of silanization on their chosen post.


Subject(s)
Dental Bonding , Post and Core Technique , Brazil , Composite Resins/chemistry , Dental Bonding/methods , Dental Stress Analysis , Glass/chemistry , Materials Testing , Resin Cements/chemistry , Silanes/chemistry , Surface Properties
8.
Eur J Prosthodont Restor Dent ; 27(3): 103-112, 2019 Aug 29.
Article in English | MEDLINE | ID: mdl-31433135

ABSTRACT

The purpose was to evaluate the influence of dentin pretreatment with titanium tetrafluoride (TiF4) on the longevity of bond strength (BS) of an indirect composite to dentin, using conventional resin cementation strategy or a self-adhesive resin cement. Forty third human molars with exposed dentin surfaces were used. The teeth were divided into groups (n = 10), according to the cementation strategy and the presence or absence of pretreatment with TiF4. Microtensile strength testing and failure mode analysis were performed after 24 hours, 180 and 360 days of storage in water. Split-plot ANOVA and Tukey's test showed that BS was significantly higher when the conventional strategy was used, regardless of the time period, and of the application or no application of pretreatment with TiF4 (p ⟨0.0001). When TiF4 was used for both cementing strategies, BS was lower after 360 days (p = 0.0019). Both cementing strategies led to the formation of a shallow hybrid layer, regardless of the presence of TiF4. BS was higher when the conventional cementation strategy was used, regardless of TiF4 pretreatment. TiF4 used as a pretreatment agent associated with different types of resin cementation was unable to maintain adhesive bond strength in the long term.


Subject(s)
Cementation , Dental Bonding , Dental Cements , Fluorides , Resin Cements , Titanium , Composite Resins , Dental Stress Analysis , Dentin , Dentin-Bonding Agents , Humans , Materials Testing , Tensile Strength
9.
Oper Dent ; 44(6): 595-608, 2019.
Article in English | MEDLINE | ID: mdl-31034349

ABSTRACT

The purpose of this in situ study was to evaluate the influence of staining solutions (coffee and cola) on the color change, microhardness, roughness, and micromorphology of the enamel surface during at-home and in-office dental bleaching. One hundred and thirty-five enamel bovine blocks were prepared to perform the evaluations. Fifteen volunteers used an intraoral appliance with nine enamel blocks for 15 days. The enamel blocks were randomly assigned among the different groups according to the three treatments: in-office bleaching with high hydrogen peroxide concentration (Opalescence Boost PF 40%, Ultradent) for 40 minutes in three sessions (first, eighth, and 15th days of treatment), at-home bleaching with low carbamide peroxide concentration (Opalescence PF 10%, Ultradent) for 60 minutes daily for 15 days, and a control group (no bleaching agent applied). The enamel blocks were immersed daily in different staining solutions (coffee or cola) for 30 minutes for 15 days or were not submitted to staining (control) to obtain a factorial scheme (3×3) of the dental bleaching treatment and staining solution (n=15). The microhardness analyses (Knoop), roughness evaluations (Ra), surface micromorphological observations, and color measurements (using the CIELAB system and the VITA Classical scale) were made before and after the bleaching treatments to assess immersion in staining solutions. Mixed model tests showed that there was a decrease in enamel microhardness after exposure to cola compared with coffee and the control group (p<0.0001) for both bleaching techniques. Roughness was higher for the cola groups (p<0.0001), and there was no significant difference between the coffee and the control groups. Generalized linear models showed that when no staining solution was applied, lighter color scores were found for the VITA Classical scale (p<0.0001). Without the staining solutions, there was an increase in luminosity (ΔL) (p=0.0444) for in-office bleaching. Lower values of Δa (p=0.0010) were observed when the staining solutions were not used. The Δb (p=0.3929) did not vary significantly between the bleaching agents, but when cola was applied, the values were significantly higher than for the control (p=0.0293). Higher values of ΔE (p=0.0089) were observed for in-office bleaching without staining solutions, while lower values of ΔE were observed for the in-office associated with coffee immersion. Regardless of whether being submitted to bleaching, the enamel stained with cola showed a decrease in microhardness, an increase in roughness, and changes in the micromorphology. The efficacy of the bleaching agents was greater when no staining solution (cola or coffee) was used, and in-office bleaching showed greater color change than the at-home bleaching technique.


Subject(s)
Tooth Bleaching , Animals , Cattle , Color , Dental Enamel , Humans , Hydrogen Peroxide , Peroxides , Staining and Labeling , Surface Properties , Urea
10.
Oral Dis ; 24(6): 957-963, 2018 Sep.
Article in English | MEDLINE | ID: mdl-29423930

ABSTRACT

OBJECTIVES: To investigate whether saliva formulations with reduced calcium (Ca) and inorganic phosphorous (Pi) concentration would affect dental erosion caused by hydrochloric acid (HCl). METHODS: Enamel and root dentine bovine slabs were embedded, polished, and measured for surface Knoop microhardness (SMH). After reference areas were created, specimens were exposed to HCl solution (0.01 M; pH 2; 120 s) and immersed in artificial salivas (6 hr) containing three different Ca/Pi concentrations (n = 15), which simulate serum conditions of normo-, mild, or severe hypocalcemia. The control group was immersed in Ca/Pi-free saliva. The study protocol was carried out 2×/day for 5 days. Surface loss of enamel and root dentine was assessed using an optical profilometer, and SMH was remeasured for enamel. RESULTS: One-way analysis of variance (p < .001) and Tukey's test showed that enamel loss in groups subjected to artificial salivas that simulated mild or severe hypocalcemia did not differ from that resembling normocalcemia. %SMH was lower when saliva was mildly and normally concentrated in Ca/Pi (p < .001). Root dentine loss was higher in saliva simulating severe hypocalcemia than in those referring to mild, hypo-, and normocalcemia. CONCLUSIONS: Depending on the dental substrate, salivary formulations resembling serum hypocalcemia affected surface loss due to erosion and rehardening thereof.


Subject(s)
Calcium/analysis , Dental Enamel/chemistry , Dentin/chemistry , Phosphorus/analysis , Saliva, Artificial/chemistry , Animals , Cattle , Hydrochloric Acid/adverse effects , Hydrochloric Acid/chemistry , Tooth Erosion/chemically induced
11.
Oper Dent ; 42(3): 308-318, 2017.
Article in English | MEDLINE | ID: mdl-28467252

ABSTRACT

The purpose of this study was to evaluate the calcium (Ca) and phosphorous (P) content in enamel bleached with high and low concentrations of hydrogen peroxide (HP) using Total Reflection X-Ray Fluorescence (TXRF) and colorimetric spectrophotometry (SPEC). Forty-eight sound human third molars were used. Their roots were embedded in polystyrene resin and immersed for seven days in an artificial saliva solution. Then they were distributed into six groups to receive the bleaching treatments. The agents of high HP concentration (for in-office use) evaluated were Whiteness HP Maxx/FGM (35% HP), Whiteness HP Blue/FGM (35% HP, 2% calcium gluconate), Pola Office+/SDI (37.5% HP, 5% potassium nitrate), and Opalescence Boost/Ultradent (38% HP, 1.1% ion fluoride, 3% potassium nitrate); these agents were applied to enamel in three sessions. The agents of low HP concentration (for home use) evaluated were Pola Day/SDI (9.5% HP) and White Class 10%/FGM (10% HP, potassium nitrate, calcium, fluoride), and these agents were applied for 14 days. Enamel microbiopsies were evaluated by TXRF and SPEC analysis before the bleaching treatment (baseline), during the treatment, and 14 days after the end of the treatment. For TXRF, the Kruskal-Wallis test showed that Ca and P were not influenced by agent (p>0.05). For SPEC, Pola Office+, Opalescence Boost, Pola Day, and White Class 10% caused a decrease of Ca over time; there was a significant decrease of P over time to Pola Office+ and White Class 10%. The Spearman test showed no correlation between the Ca (p=0.987; r2=-0.020) and P (p=0.728, r2=0.038) obtained by SPEC and TXRF. For TXRF and SPEC, changes in Ca and P during bleaching occurred independently of the HP concentration used.


Subject(s)
Calcium/chemistry , Dental Enamel/chemistry , Dental Enamel/drug effects , Hydrogen Peroxide/chemistry , Phosphorus/chemistry , Tooth Bleaching Agents/chemistry , Colorimetry , Fluorescence , Hardness , Humans , In Vitro Techniques , Molar, Third , Spectrophotometry , X-Rays
12.
Oper Dent ; 42(1): 30-40, 2017.
Article in English | MEDLINE | ID: mdl-27723425

ABSTRACT

The purpose of this study was to evaluate bleaching methods containing hydrogen peroxide (HP) or carbamide peroxide (CP), dispensed in customized or prefilled trays, in terms of color change, tooth sensitivity, gingival irritation, acceptance, and comfort. Seventy-five volunteers were randomly selected and distributed according to the whitening agent (n=25): 10% HP dispensed in prefilled trays (Opalescence Go 10%) and 9.5% HP (Pola Day) and 10% CP both delivered in customized trays (Opalescence PF 10%). HP was applied for 30 min/d for 14 days (d), and CP for 8 h/d for 14 days. Evaluations were performed at baseline and at 7 days and 14 days of treatment. Color change was measured with Commission internationale de l'éclairage color coordinates (L*, a*, b*), Vita Classical, and 3D Master scales. A visual analog scale was used to assess tooth sensitivity, acceptance of the method and degree of comfort of the tray. Gingival irritation was evaluated as present or absent and localized or generalized. Regarding gingival irritation, tray acceptance, and tooth sensitivity, no differences were observed among the groups at any time (p>0.05). As for degree of comfort, 10% HP showed lower scores (comfortable) than 10% CP, with significant differences (p<0.05) from the other groups (comfortable to very comfortable). In terms of ΔL, Δa, and ΔE, no difference was observed among the groups or between the time periods (p>0.05). The Δb average was higher at 14 days (p<0.05), and there was no difference among the groups (p>0.05). Localized gingival irritation was observed in both tray methods. Mild tooth sensitivity was observed with time, regardless of the bleaching agent concentration or the application time. Color change was similar for all the groups at 7 days and 14 days, but there was a greater reduction in the yellow hue at 14 days. All the bleaching methods were highly accepted and effective in promoting whitening. Although prefilled trays are generally comfortable, they proved less comfortable than customized trays.


Subject(s)
Dental Devices, Home Care , Tooth Bleaching Agents/therapeutic use , Tooth Bleaching/instrumentation , Adult , Carbamide Peroxide , Drug Combinations , Female , Humans , Hydrogen Peroxide/therapeutic use , Male , Peroxides/therapeutic use , Polyvinyls , Treatment Outcome , Urea/analogs & derivatives , Urea/therapeutic use
13.
Oper Dent ; 39(1): 64-71, 2014.
Article in English | MEDLINE | ID: mdl-23675741

ABSTRACT

The aim of this study was to evaluate the effect of a chlorhexidine and/or ethanol application on the bond strength of an etch-and-rinse, hydrophobic adhesive system either under in vitro aging or in situ cariogenic challenge. The dentin surface of 36 human third molars were flattened and allocated into four groups to be treated with chlorhexidine, ethanol, or chlorhexidine + ethanol or left unexposed to any solution (control) (n=9). Then, a resin composite restoration was made on the dentin surface and longitudinal sticks were obtained. Sticks from each tooth were assigned to three test conditions: stored in water in vitro for 24 hours, stored in water in vitro for 6 months, or worn in situ for 14 days. During in situ wear time, a high-cariogenic challenge condition was simulated. Specimens were tested for microtensile bond strength (µTBS). Multivariate analysis of variance and Tukey's test showed that chlorhexidine, ethanol, or chlorhexidine + ethanol did not affect the µTBS. The in vitro µTBS values were significantly lower for the specimens stored for 6 months than for those stored for 24 hours. Intermediate µTBS values were shown by the specimens worn in situ. Thus, use of chlorhexidine and/or ethanol was incapable of containing the degradation at the bond interface in the in vitro model. The in situ model was capable of reducing bond strength similarly to the in vitro/6 months model. Despite this, the in situ bond strength was still similar to that of the in vitro/24-hour model.


Subject(s)
Chlorhexidine/pharmacology , Dental Cements/metabolism , Dental Etching/methods , Dentin/drug effects , Ethanol/pharmacology , Composite Resins/therapeutic use , Dental Bonding , Dental Stress Analysis , Humans , In Vitro Techniques
14.
Microsc Res Tech ; 73(11): 1030-5, 2010 Oct.
Article in English | MEDLINE | ID: mdl-20146349

ABSTRACT

BACKGROUND: It remains uncertain as to whether or not CO(2) laser is able to hinder demineralization of enamel. The possibility to use bovine instead of human teeth on anticariogenic studies with laser has not yet been determined. PURPOSE: To compare the ability of CO(2) laser and fluoride to inhibit caries-like lesions in human enamel and to test whether a similar pattern of response would hold for bovine enamel. STUDY DESIGN: Ninety-six enamel slabs (2 × 2 × 4 mm) (48 from bovine and 48 from human teeth) were randomly distributed according to surface treatment (n = 12): CO(2) laser, 5% sodium fluoride varnish (FV), 1.23% acidulated phosphate fluoride (APF) gel, or no treatment (control). Specimens were subjected to a 14-day in vitro cariogenic challenge. Microhardness (SMH) was measured at 30 µm from the surface. For ultrastructural analysis, additional 20 slabs of each substrate (n = 5) received the same treatment described earlier and were analyzed by SEM. RESULTS: ANOVA and Tukey test ascertained that CO(2) laser promoted the least mineral loss (SMH = 252(a)). Treatment with FV resulted in the second highest values (207(b)), which was followed by APF (172(c)). Untreated specimens performed the worst (154(d)). SEM showed no qualitative difference between human and bovine teeth. APF and control groups exhibited surfaces covered by the smear layer. A granulate precipitate were verified on FV group and fusion of enamel crystals were observed on lased-specimens. CONCLUSIONS: CO(2) laser may control caries progression more efficiently than fluoride sources and bovine teeth may be a suitable substitute for human teeth in studies of this nature.


Subject(s)
Dental Enamel , Fluorides/pharmacology , Hardness , Lasers, Gas/therapeutic use , Microscopy, Electron, Scanning/methods , Analysis of Variance , Animals , Cariogenic Agents/pharmacology , Cattle , Dental Caries/prevention & control , Dental Enamel/drug effects , Dental Enamel/radiation effects , Hardness/drug effects , Hardness/radiation effects , Hardness Tests/methods , Humans , Models, Biological , Photomicrography , Tooth Demineralization
15.
J Dent ; 37(10): 786-90, 2009 Oct.
Article in English | MEDLINE | ID: mdl-19595495

ABSTRACT

OBJECTIVES: To assess whether pastes containing casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) and calcium sodium phosphosilicate (CSP) control artificial caries lesion progression. METHODS: Enamel slabs of bovine teeth were embedded in polyester resin and had their enamel surfaces serially polished, and tested for surface microhardness (SMH, 25 g, 5 s). Incipient caries-like lesions were pre-formed and specimens were evaluated by microhardness test (SMH(post-lesion)) and randomly assigned to five treatment groups (n=15): (1) regular dentifrice (RE, 1,100 ppm F); (2) dentifrice with calcium sodium phosphosilicate (CSP); (3) amorphous calcium phosphate stabilized by casein phosphopeptide (CPP-ACP); (4) CPP-ACP with 900 ppm F (CPP-ACP+F) and (5) control group-unexposed to any remineralizing agent. Treatments were applied five times, after the de-remineralization period in the cariogenic challenges. Post-treatments SMH measurements were conducted (SMH(post-treatment)). RESULTS: ANOVA was applied for data evaluation and revealed a significant difference among the treatments (p=0.0161). Tukey's test was conducted and the percentage of mineral loss was calculated. Specimens exposed to CSP (7.1%), RE (6.7%) and CPP-ACP+F (3.8%) showed lower mineral loss than those that in the control group (-11.0%). CPP-ACP group (3.2%) differed from the control, CSP and RE groups. CONCLUSIONS: Depending on the agent used, a remineralizing effect may be expected, which reflects in caries lesions progression.


Subject(s)
Dental Caries/prevention & control , Dentifrices/therapeutic use , Tooth Remineralization/methods , Animals , Calcium Phosphates/therapeutic use , Caseins/therapeutic use , Cattle , Dental Enamel , Dentifrices/chemistry , Drug Combinations , Fluorides/therapeutic use , Glass , Hardness , Random Allocation
16.
Caries Res ; 40(5): 435-9, 2006.
Article in English | MEDLINE | ID: mdl-16946613

ABSTRACT

The usefulness of fluoride-releasing restorations in secondary caries prevention may be questioned because of the presence of other common sources of fluoride and because of ageing of the restorations. This study tested the hypothesis that glass-ionomer cement restorations, either aged or unaged, do not prevent secondary root caries, when fluoride dentifrice is frequently used. Sixteen volunteers wore palatal appliances in two phases of 14 days, according to a 2 x 2 crossover design. In each phase the appliance was loaded with bovine root dentine slabs restored with either glass-ionomer or resin composite, either aged or unaged. Specimens were exposed to cariogenic challenge 4 times/day and to fluoridated dentifrice 3 times/day. The fluoride content in the biofilm (FB) formed on slabs and the mineral loss (DeltaZ) around the restorations were analysed. No differences were found between restorative materials regarding the FB and the DeltaZ, for either aged (p = 0.792 and p = 0.645, respectively) or unaged (p = 1.00 and p = 0.278, respectively) groups. Under the cariogenic and fluoride dentifrice exposure conditions of this study, the glass-ionomer restoration, either aged or unaged, did not provide additional protection against secondary root caries.


Subject(s)
Cariostatic Agents/therapeutic use , Dental Restoration, Permanent/methods , Dentifrices/therapeutic use , Fluorides/therapeutic use , Glass Ionomer Cements , Root Caries/prevention & control , Animals , Cariogenic Agents , Cattle , Cross-Over Studies , Dental Plaque/chemistry , Dentin , Fluorides/analysis , Humans , Resin Cements , Statistics, Nonparametric
17.
Biomaterials ; 26(24): 4932-7, 2005 Aug.
Article in English | MEDLINE | ID: mdl-15769527

ABSTRACT

Based on the incomplete understanding on how filler features influence the wear resistance and monomer conversion of resin composites, this study sought to evaluate whether materials containing different shapes and combinations of size of filler particles would perform similarly in terms of three-body abrasion and degree of conversion. Twelve experimental monomodal, bimodal or trimodal composites containing either spherical or irregular shaped fillers ranging from 100 to 1500 nm were examined. Wear testings were conducted in the OHSU wear machine (n = 6) and quantified after 10(5) cycles using a profilometer. Degree of conversion (DC) was measured by FTIR spectrometry at the surface of the composites (n = 6). Data sets were analyzed using one-way Anova and Tukey's test at a significance level of 0.05. Filler size and geometry was found to have a significant effect on wear resistance and DC of composites. At specific sizes and combinations, the presence of small filler particles, either spherical or irregular, may aid in enhancing the wear resistance of composites, without compromising the percentage of reacted carbon double bonds.


Subject(s)
Composite Resins/chemistry , Hardness Tests/methods , Materials Testing/methods , Nanostructures/chemistry , Composite Resins/analysis , Hardness , Nanostructures/analysis , Particle Size
18.
Caries Res ; 38(5): 473-7, 2004.
Article in English | MEDLINE | ID: mdl-15316192

ABSTRACT

This crossover study aimed to investigate abrasion of previously eroded hard dental tissues by a whitening dentifrice compared to a regular dentifrice. After a 3-day lead-in period, 14 volunteers were randomly assigned to use one of the toothpastes while wearing a removable appliance, containing 3 enamel and 3 root dentine slabs on each side. On the first day salivary pellicle was allowed to form. Twice daily for the following 3 days, one side of each appliance was immersed in an acidic carbonated drink ex vivo while the other side remained unexposed. Specimens were then brushed with the allocated dentifrice. After a 3-day washout period, new sets of enamel and dentine slabs were mounted in the appliances and the participants commenced period 2 using the alternative toothpaste. Acid-treated specimens always showed more wear than untreated specimens. The whitening dentifrice did not significantly increase the wear of softened enamel compared with the regular dentifrice. Brushing with the whitening toothpaste led to significantly greater wear of sound enamel and of both eroded and sound dentine than the regular dentifrice. The results suggest that whitening dentifrices may not increase the wear of acid-softened enamel but may have a more deleterious effect on dentine than regular toothpastes.


Subject(s)
Dentifrices/adverse effects , Tooth Abrasion/chemically induced , Tooth Bleaching/adverse effects , Tooth Erosion/complications , Adult , Analysis of Variance , Carbonated Beverages/adverse effects , Cariostatic Agents/therapeutic use , Cross-Over Studies , Dental Enamel/drug effects , Dental Enamel/pathology , Dental Pellicle/drug effects , Dental Pellicle/pathology , Dentifrices/therapeutic use , Dentin/drug effects , Dentin/pathology , Female , Fluorides/therapeutic use , Humans , Male , Phosphates/therapeutic use , Sodium Fluoride/therapeutic use , Tooth Abrasion/pathology , Tooth Root/drug effects , Tooth Root/pathology
19.
J Oral Rehabil ; 30(11): 1123-7, 2003 Nov.
Article in English | MEDLINE | ID: mdl-14641679

ABSTRACT

This study evaluated the effect of non-vital tooth bleaching on microleakage of composite resin/bovine tooth interface at different post-bleaching times. A total of 320 teeth were cleaned. A pulp chamber access cavity was made at the lingual surface of each tooth. The teeth were randomly divided into four groups: SPH - sodium perborate + 30% hydrogen peroxide; SPW - sodium perborate + distilled water; CP-37% carbamide peroxide; and CON-distilled water (control). The bleaching agents were replaced every 7 days, over 4 weeks. Following bleaching procedures, the groups were divided into four subgroups (n = 20), according to the post-bleaching times: 0 (baseline), 7, 14 and 21 days. After that, the cavities were restored with an adhesive system (Single Bond; 3M Co., St Paul, MN, USA) and a composite resin (Z100/3M). The specimens were thermocycled, stained with 2% methylene blue solution (pH 7), and sectioned longitudinally. The teeth were evaluated blind and independently by three previously calibrated examiners, to provide representative scores. The data were submitted to Kruskal-Wallis and multiple comparison tests (alpha=0.05). At baseline and 7 days, the SPH group showed a higher degree of dye penetration than the CON (P=0.04). At 14 and 21 days, there were no differences among groups. The association of sodium perborate with 30% hydrogen peroxide or with water may affect the sealing ability of composite resin restorations performed up to 7 days after bleaching procedures.


Subject(s)
Dental Leakage/chemically induced , Dental Restoration, Permanent , Tooth Bleaching/adverse effects , Urea/analogs & derivatives , Adhesiveness/drug effects , Animals , Borates/toxicity , Carbamide Peroxide , Cattle , Composite Resins/chemistry , Dental Bonding/methods , Drug Combinations , Hydrogen Peroxide/toxicity , Peroxides/toxicity , Time Factors , Tooth Bleaching/methods , Urea/toxicity
20.
J Oral Rehabil ; 29(9): 864-71, 2002 Sep.
Article in English | MEDLINE | ID: mdl-12366542

ABSTRACT

The aim of this study was to evaluate the effect of different storage media upon the surface micromorphology of resin-based restoratives. One resin-modified glass-ionomer (Fuji II LC Improved), one polyacid-modified composite resin (Dyract AP), one microfilled composite resin (Durafill VS), and one hybrid composite resin (Filtek Z250) were tested. For each material, 45 standardized cylindrical specimens were randomly made. After 24 h, samples were finished and polished, and their surface roughness measured to obtain Ra (micro m) baseline values (Bv). Fifteen specimens of each material were then stored at 37 +/- 1 degrees C, for 24 h, either in distilled deionized water or in artificial saliva, or else subjected to a pH-cycling regimen. At the end of 10 days of storage, final readings (Fv) of surface roughness were obtained. The Analysis of Covariance (alpha=0.05), considering the covariate Bv showed a significant interaction between restorative materials and storage media (P value=0.0000). Multiple comparison Tukey's test revealed that the surface roughness of resin-based restoratives subjected to a pH-cycling model was significantly higher compared with both distilled deionized water and artificial saliva. Micromorphological changes were noticed in a situation of acid challenge.


Subject(s)
Compomers , Composite Resins/chemistry , Glass Ionomer Cements/chemistry , Resin Cements/chemistry , Acids , Analysis of Variance , Drug Storage , Materials Testing , Methacrylates/chemistry , Resins, Synthetic/chemistry , Saliva, Artificial , Silicates/chemistry , Statistics, Nonparametric , Surface Properties , Water
SELECTION OF CITATIONS
SEARCH DETAIL
...