Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
PLoS One ; 7(8): e42733, 2012.
Article in English | MEDLINE | ID: mdl-22900045

ABSTRACT

Stable positioning between a measurement probe and its target from sub- to few micrometer scales has become a prerequisite in precision metrology and in cellular level measurements from biological tissues. Here we present a 3D stabilization system based on an optoelectronic displacement sensor and custom piezo-actuators driven by a feedback control loop that constantly aims to zero the relative movement between the sensor and the target. We used simulations and prototyping to characterize the developed system. Our results show that 95% attenuation of movement artifacts is achieved at 1 Hz with stabilization performance declining to ca. 70% attenuation at 10 Hz. Stabilization bandwidth is limited by mechanical resonances within the displacement sensor that occur at relatively low frequencies, and are attributable to the sensor's high force sensitivity. We successfully used brain derived micromotion trajectories as a demonstration of complex movement stabilization. The micromotion was reduced to a level of ∼1 µm with nearly 100 fold attenuation at the lower frequencies that are typically associated with physiological processes. These results, and possible improvements of the system, are discussed with a focus on possible ways to increase the sensor's force sensitivity without compromising overall system bandwidth.


Subject(s)
Mechanics , Motion , Electronics/instrumentation , Vibration
2.
Sci Rep ; 2: 324, 2012.
Article in English | MEDLINE | ID: mdl-22442752

ABSTRACT

Ideally, neuronal functions would be studied by performing experiments with unconstrained animals whilst they behave in their natural environment. Although this is not feasible currently for most animal models, one can mimic the natural environment in the laboratory by using a virtual reality (VR) environment. Here we present a novel VR system based upon a spherical projection of computer generated images using a modified commercial data projector with an add-on fish-eye lens. This system provides equidistant visual stimulation with extensive coverage of the visual field, high spatio-temporal resolution and flexible stimulus generation using a standard computer. It also includes a track-ball system for closed-loop behavioural experiments with walking animals. We present a detailed description of the system and characterize it thoroughly. Finally, we demonstrate the VR system's performance whilst operating in closed-loop conditions by showing the movement trajectories of the cockroaches during exploratory behaviour in a VR forest.

3.
J Neurosci Methods ; 180(2): 290-5, 2009 Jun 15.
Article in English | MEDLINE | ID: mdl-19379772

ABSTRACT

Electrophysiological recordings from a single or population of neurons are currently the standard method for investigating neural mechanisms with high spatio-temporal resolution. It is often difficult or even impossible to obtain stable recordings because of brain movements generated by the cardiac and respiratory functions and/or motor activity. An alternative approach to extensive surgical procedures aimed to reduce these movements would be to develop a control system capable of compensating the relative movement between the recording site and the electrode. As a first step towards such a system, an accurate method capable of measuring brain micromotion, preferably in 3D, in a non-invasive manner is required. A wide variety of technical solutions exist for displacement measurement. However, increased sensitivity in the measurement is often accompanied by strict limitations to sensor handling, implementation and external environment. In addition, majority of the current methods are limited to measurement along only one axis. We present a novel, minimally invasive, 3D displacement sensor with displacement resolution exceeding 70 nm along each axis. The sensor is based on optoelectronic detection of movements of a spring-like element with three degrees of freedom. It is remarkably compact with needle-like probe and can be packaged to withstand considerable mishandling, which allow easy implementation to existing measurement systems. We quantify the sensor performance and demonstrate its capabilities with an in vivo measurement of blowfly brain micromotion in a preparation commonly used for electrophysiology.


Subject(s)
Biosensing Techniques/instrumentation , Brain/physiology , Electrophysiology/instrumentation , Motion Perception/physiology , Neurophysiology/instrumentation , Pattern Recognition, Automated/methods , Animals , Artifacts , Biosensing Techniques/methods , Brain/anatomy & histology , Diptera , Electrodes , Electronics/instrumentation , Electronics/methods , Electrophysiology/methods , Microscopy/instrumentation , Microscopy/methods , Minimally Invasive Surgical Procedures/instrumentation , Minimally Invasive Surgical Procedures/methods , Neurophysiology/methods , Optics and Photonics/instrumentation , Optics and Photonics/methods , Restraint, Physical/instrumentation , Restraint, Physical/methods
4.
J Biomed Mater Res A ; 82(4): 810-9, 2007 Sep 15.
Article in English | MEDLINE | ID: mdl-17326140

ABSTRACT

In the present study, we examined the effect of NiTi oxidation on material surface characteristics related to biocompatibility. Correspondence between electron work function (EWF) and adhesive force predicted by electron theory of adsorption as well as the effect of surface mechanical stress on the adhesive force were studied on the nonoxidized and oxidized at 350, 450, and 600 degrees C NiTi alloy for medical application. The adhesive force generated by the material surface towards the drops of alpha-minimal essential medium (alpha-MEM) was used as a characteristic of NiTi adsorption properties. The study showed that variations in EWF and mechanical stress caused by surface treatment were accompanied by variations in adhesive force. NiTi oxidation at all temperatures used gave rise to decrease in adhesive force and surface stress values in comparison to the nonoxidized state. In contrary, the EWF value revealed increase under the same condition. Variations in surface oxide layer thickness and its phase composition were also followed. The important role of oxide crystallite size in EWF values within the range of crystallite dimensions typical for NiTi surface oxide as an instrument for the fine regulation of NiTi adsorption properties was demonstrated. The comparative oxidation of pure titanium and NiTi showed that the effect of Ni on the EWF value of NiTi surface oxide is negligible.


Subject(s)
Coated Materials, Biocompatible , Nickel , Titanium , Adhesiveness , Adsorption , Culture Media , Elasticity , Electrochemistry , Humans , In Vitro Techniques , Materials Testing , Oxidation-Reduction , Prostheses and Implants , Stress, Mechanical , Surface Properties , X-Ray Diffraction
SELECTION OF CITATIONS
SEARCH DETAIL
...