Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Cureus ; 15(12): e49951, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38179359

ABSTRACT

Objective Doppler velocimetry is an established method of antepartum fetal surveillance in pre-eclampsia. Cerebroplacental ratio detects the centralization of fetal blood flow and the insufficiency in placental circulation. It is postulated to be a better marker of perinatal outcome than either vessel Doppler alone. The current study aims to assess the cerebroplacental ratio as a predictor of adverse perinatal outcomes and compare it to the systolic/diastolic (S/D) ratio of umbilical artery (UA) and middle cerebral artery (MCA) in hypertensive disorders of pregnancy. Material and methods The present prospective observational cohort study included 100 patients with hypertensive disorders of pregnancies between 32 and 37 weeks. Ultrasound with Doppler was done and the following parameters were assessed: fetal biometry, amniotic fluid index, umbilical artery pulsatility index, middle cerebral artery pulsatility index, S/D ratio of umbilical artery, S/D ratio of middle cerebral artery, and cerebroplacental ratio. Sensitivity, specificity, positive and negative predictive values were calculated for the cerebroplacental ratio and S/D ratios of umbilical and middle cerebral arteries. McNemar's test was used for the comparison of sensitivity and specificity. Results Thirty-two patients had an abnormal cerebroplacental ratio. Adverse perinatal outcomes such as a cesarean section for fetal distress, small for gestational age, APGAR < 7 at 1 and 5 minutes, NICU admission, and perinatal mortality were more in the group with abnormal cerebraplacental ratio and the difference was statistically significant. Conclusion The cerebroplacental ratio is a more reliable predictor of adverse perinatal outcomes and should be routinely calculated during obstetrical Doppler for antepartum fetal surveillance in case of hypertensive disorders of pregnancy.It suggested that the cerebroplacental ratio may be calibrated in the software ofthe Doppler ultrasonography machine for routine use in high-risk pregnancies.

2.
Gynecol Obstet Invest ; 82(2): 157-162, 2017.
Article in English | MEDLINE | ID: mdl-27486902

ABSTRACT

OBJECTIVE: To assess the feasibility and efficacy of Keyes punch biopsy instrument (KP) in diagnosing cervical lesions and compare it with cervical punch biopsy forceps (CP). METHODS: 75 women having satisfactory colposcopy with abnormal transformation zone were included and paired colposcopic directed biopsies were taken using KP followed by CP from the same target area. RESULTS: It was feasible in all cases to take cervical biopsy with KP after increasing its effective length. The volume of gross specimen obtained by KP was less than CP (0.076 ± 0.097 vs. 0.101 ± 0.156 cm3, p = 0.061), however on microscopic examination, mean length and mean depth of tissue in KP was greater than CP by 0.06 mm (p = 0.810) and 0.14 mm (p = 0.634) respectively. Exact agreement was found with the final surgical specimen in 42% of cases in both the biopsy forceps. CONCLUSION: KP is almost at par with CP for diagnosing preinvasive cervical lesions and is a useful adjunct to the existing armamentarium of biopsy forceps.


Subject(s)
Biopsy/instrumentation , Colposcopy/standards , Surgical Instruments/standards , Uterine Cervical Diseases/diagnosis , Adult , Feasibility Studies , Female , Humans , Obstetrical Forceps/standards , Uterine Cervical Neoplasms
SELECTION OF CITATIONS
SEARCH DETAIL
...