1.
J Cardiovasc Dev Dis ; 11(6)2024 May 22.
Article in English | MEDLINE | ID: mdl-38921660

ABSTRACT

We characterized the performance, as well as the safety, of a second-generation thin-strut sirolimus-eluting stent with a biodegradable polymer, Alex Plus (Balton, Poland), implanted in patients with type 2 diabetes (DM) with a 4-year follow-up. We defined the primary endpoint as the 48-month rate of major cardiovascular adverse events (MACE), including cardiac death, myocardial infarction (MI), or target lesion revascularization (TLR). The secondary endpoints were all-cause death, cardiac death, MI, and TLR rates at 12, 24, 36, and 48 months. We enrolled 232 patients in whom 282 stents were implanted, including 97 DM and 135 non-DM patients. The mean age of the DM patients was 69.5 ± 10.1 years and females accounted for 30% of the patients. DM patients had higher rates of arterial hypertension (97% vs. 88%, p = 0.016), dyslipidemia (86% vs. 70%, p = 0.005), prior MI (61% vs. 40%, p = 0.002), prior PCI (65% vs. 50%, p = 0.020), and prior CABG (14% vs. 5.9%, p = 0.029). We recorded statistically significant differences for MACE (HR 1.85, 95% CI 1.01-3.41, p = 0.046), cardiac death (HR 4.46, 95% CI 1.44-13.8, p = 0.010), and MI (HR 3.17, 95% CI 1.10-9.12, p = 0.033), but not for TLR, between DM and non-DM patients in terms of the analyzed endpoints at 4 years. Our study showed that Alex Plus was efficient and safe in a contemporary cohort of real-world DM patients undergoing percutaneous revascularization.

2.
J Pers Med ; 13(11)2023 Nov 03.
Article in English | MEDLINE | ID: mdl-38003888

ABSTRACT

We characterized the performance as well as safety of a second-generation thin-strut sirolimus-eluting stent with a biodegradable polymer, Alex Plus (Balton, Poland), deployed in the acute coronary syndrome (ACS) setting. We enrolled patients who were subjected to percutaneous coronary intervention (PCI) between July 2015 and March 2016 and took into consideration demographics, clinical and laboratory data, and clinical outcomes. We defined the primary endpoint as the 48-month rate of major cardiovascular adverse events (MACE), including cardiac death, myocardial infarction (MI), or target lesion revascularization (TLR). The secondary endpoints were all-cause death, cardiac death, MI, and TLR rates at 12-, 24-, 36-, and 48 months. We enrolled 232 patients in whom 282 stents were implanted, including 88 ACS and 144 chronic coronary syndrome (CCS) patients. The mean age of the ACS population was 67 ± 13 years old, and 32% of it consisted of females. Patients with ACS were characterized by lower rates of arterial hypertension (85.2% vs. 95.8%, p = 0.004), dyslipidemia (67% vs. 81.9%, p = 0.01), prior MI (34.1% vs. 57.6%, p < 0.001), and prior PCI (35.2% vs. 68.8%, p < 0.001). At 48 months, among the ACS patients, the rates of MACE, death, cardiac death, MI, and TLR were 23.9%, 11.4%, 7.9%, 9.1%, and 10.2%, respectively. No stent thrombosis cases were reported. Multivariable Cox regression revealed that the statistically significant MACE predictors were massive calcifications in coronary arteries (HR 9.0, 95% CI 1.75-46.3, p = 0.009), post-dilatation (HR 3.78, 95% CI 1.28-11.2, p = 0.016), prior CABG (HR 6.64, 95% CI 1.62-27.1, p = 0.008), vitamin K antagonist use (HR 5.99, 95% CI 1.29-27.8, p = 0.022), and rivaroxaban use (HR 51.7, 95% CI 4.48-596, p = 0.002). The study findings show that Alex Plus was effective and safe in a contemporary cohort of real-world ACS patients undergoing primary PCI. The outcomes were comparable between the ACS and chronic coronary syndrome patients, with a trend of lower TLR in ACS patients at 4 years.

3.
J Clin Med ; 12(16)2023 Aug 15.
Article in English | MEDLINE | ID: mdl-37629356

ABSTRACT

We aimed to characterize the performance and safety of percutaneous coronary intervention (PCI) in complex, high-risk indicated procedure (CHIP) and high-bleeding-risk (HBR) patients at a 4-year follow up. We included all consecutive patients who underwent PCI with the sirolimus-eluting coronary stent Alex Plus (Balton, Poland) between July 2015 and March 2016. We analyzed various baseline demographic and clinical characteristics, laboratory data, and clinical outcomes. We enrolled 232 patients in whom 282 stents were implanted, including 81 patients meeting the CHIP criteria and 76 patients meeting the HBR criteria. In the whole population, the mean age was 68 ± 11 years, and 23.7% were females. Most procedures were performed from radial access (83.2%) using a 6F guiding catheter (95.7%). The lesions were mostly predilated (61.6%), and postdilatation was performed in 37.9%. The device success was 99.6% (in one case, a second stent was required due to heavy calcifications). Additional stents were deployed in 39% of cases due to edge dissection (6.9%), side branch stenting (5.2%), or diffuse disease (26.9%). Myocardial infarction (MI) type 4a was revealed in 2.2% of cases. At 4 years, the MACE rates for the whole population and for CHIP and HBR patients were 23.3%, 29.6%, and 27.6%, respectively. CHIP patients had a higher risk of MACEs (29.6% vs. 19.9%, HR 1.69, p = 0.032) and cardiac death (11.1% vs. 4.6%, HR 2.50, p = 0.048). There were no differences for MI (7.4% vs. 6.6%, p = 0.826) and TLR (18.5% vs. 12.6%, p = 0.150). HBR patients were also characterized by a higher risk of MACEs (27.6% vs. 21.2%, HR 1.84, p = 0.049) and cardiac death (17.1% vs. 1.9%, HR 9.61, p < 0.001). There were no differences for MI (7.9% vs. 6.4%, p = 0.669) and TLR (11.8% vs. 16.0%, p = 0.991). PCI in CHIP and HBR patients is feasible with a low rate of periprocedural complications. Nevertheless, CHIP and HBR patients are at a high risk of future adverse events and require strict surveillance to improve outcomes.

4.
J Pers Med ; 13(5)2023 May 19.
Article in English | MEDLINE | ID: mdl-37241026

ABSTRACT

The long-term outcomes of patients with myocardial infarction with non-obstructive coronary arteries (MINOCA) are still not well known. This study aimed to compare the characteristics and outcomes between MINOCA and STEMI patients in a 5-year follow-up. Between 2010 and 2015 we identified 3171 coronary angiography procedures performed due to acute coronary syndrome, from which 153 had a working MINOCA diagnosis, and the final diagnosis of MINOCA was ascribed to 112 (5.8%) patients. Additionally, we matched 166 patients with STEMI and obstructive coronary arteries as the reference group. In MINOCA patients (mean age of 63 years), there were more females (60% vs. 26%, p < 0.001), and patients presented most frequently with NSTEMI (83.9%). Patients with MINOCA had more frequent atrial fibrillation (22% vs. 5.4%, p < 0.001) and higher left ventricular ejection fraction (59 ± 10% vs. 54 ± 10%, p < 0.001) compared to STEMI patients. We observed only a trend for a higher rate of MACE in STEMI patients at 5 years (11.6% vs. 18.7%, HR 1.82, 95% CI 0.91-3.63, p = 0.09). In multivariable Cox regression, only beta-blocker use was a protective factor (a trend observed), with HR 0.33, 95% CI 0.10-1.15, p = 0.082 of future MACE. The outcomes of MINOCA and STEMI patients were comparable in the 5-year follow-up.