Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Echocardiography ; 32(11): 1723-7, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26096634

ABSTRACT

The authors describe transient apical thickening mimicking apical hypertrophic cardiomyopathy following apical ballooning syndrome. These findings are observed on multimodality cardiac imaging and appear to constitute a novel entity. Possible pathophysiologic mechanisms are explored.


Subject(s)
Takotsubo Cardiomyopathy/diagnostic imaging , Takotsubo Cardiomyopathy/physiopathology , Aged , Electrocardiography , Fatal Outcome , Female , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Syndrome , Tomography, X-Ray Computed , Ultrasonography
2.
Eur J Echocardiogr ; 9(3): 351-5, 2008 May.
Article in English | MEDLINE | ID: mdl-17658300

ABSTRACT

AIM: To compare and contrast 3 different echocardiographic methods used to measure left atrial (LA) volume: biplane area length (AL), biplane modified Simpson (SIMP), and prolate ellipse (PE) methods. METHODS AND RESULTS: A review of consecutive patients who presented to our outpatient echocardiography laboratory for a resting transthoracic study between April 2006 and May 2006 was performed. Echocardiograms were reexamined and LA volume measured using the AL, SIMP, and PE methods. Of 102 consecutive patients evaluated, 97 had a measure of LA volume using all 3 methods. A significant difference in the measurement of mean +/- SD LA volume was noted among the 3 different methods: 37 +/- 16 mL/m(2) for AL, 34 +/- 14 mL/m(2) for SIMP, and 27 +/- 12 mL/m(2) for PE. The PE method yielded routinely smaller values compared with either the AL or SIMP method (P < 0.001). Differences increased with increased LA volume. The SIMP method derived consistently smaller (<5 mL/m(2)) values than those of the AL method, consistent across the full range of LA volumes. CONCLUSION: Significant differences exist among these 3 commonly used methods for measuring LA volume. Standardization of the measurement of LA volume is recommended.


Subject(s)
Heart Atria/diagnostic imaging , Aged , Aged, 80 and over , Female , Heart Atria/anatomy & histology , Humans , Male , Middle Aged , Organ Size , Retrospective Studies , Ultrasonography
3.
J Am Soc Echocardiogr ; 19(7): 919-23, 2006 Jul.
Article in English | MEDLINE | ID: mdl-16825003

ABSTRACT

Although 2-dimensional echocardiography with adjunct intravenous contrast media improves endocardial visualization and enhances quality of spectral Doppler signals, widespread use of contrast agents has not occurred for various reasons. Results from this study indicate that discretionary use of contrast media will enhance endocardial and Doppler signal visualization scores without an impact on total procedure duration, lending credence to an argument for a lower threshold for discretionary use of contrast media.


Subject(s)
Echocardiography/methods , Image Enhancement/methods , Ventricular Dysfunction, Left/diagnostic imaging , Aged , Female , Humans , Male , Observer Variation , Prognosis , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...