1.
Phys Med Biol ; 53(5): 1369-84, 2008 Mar 07.
Article in English | MEDLINE | ID: mdl-18296767

ABSTRACT

Magnification is a special technique applied in mammography in cases where breast complaints have already been noticed, aiming to examine a specific area of the breast. Small-sized focal spots are essential in such techniques in order to reduce the resultant geometrical unsharpness. The x-ray intensity distribution of the focal spot is another crucial parameter for such a technique as it affects the mammographic resolution. In this study a Monte Carlo simulation model is utilized, in order to examine the effect of a wide range of focal spot sizes and three representative intensity distributions on spatial resolution under magnification. A thick sharp edge consisting of lead, non-transparent to x-rays was imaged under various conditions for this purpose, and the corresponding spatial resolution was calculated through the modulation transfer function (MTF). Results demonstrate that focal spots larger than 0.10 mm can mainly be used for low degrees of magnification, especially when combined with double peak Gaussian intensity distribution of the focal spot (sum of two single peak Gaussian distributions with different centers), as the resultant spatial resolution is not as high as the corresponding from smaller foci or uniform and single peak Gaussian distributions. Moreover, for the degrees of magnification usually utilized in clinical practice they do not reach the acceptable limit of 12 lp mm(-1). The replacement of the x-ray tube when the focal spot starts being destroyed is very crucial as the possible alteration of single peak Gaussian distribution to double peak Gaussian results in the degradation of spatial resolution. A focal spot of 0.10 mm or smaller, combined with single peak Gaussian intensity distribution, can be considered appropriate even for higher degrees of magnification and its use can contribute in the effort to optimize the magnification views in mammography.


Subject(s)
Mammography/methods , Monte Carlo Method , Radiographic Magnification/methods , Artifacts , Reproducibility of Results
2.
Phys Med Biol ; 52(21): 6439-60, 2007 Nov 07.
Article in English | MEDLINE | ID: mdl-17951854

ABSTRACT

Materials such as a-Se, a-As(2)Se(3), GaSe, GaAs, Ge, CdTe, CdZnTe, Cd(0.8)Zn(0.2)Te, ZnTe, PbO, TlBr, PbI(2) and HgI(2) are potential candidates as photoconductors in direct detectors for digital mammography. The x-ray induced primary electrons inside a photoconductor's bulk comprise the initial signal that propagates and forms the final signal (image) on the detector's electrodes. An already developed model for a-Se has been properly extended to simulate the primary electron production in the materials mentioned. Primary electron characteristics, such as their energy, angular and spatial distributions that strongly influence the characteristics of the final image, were studied for both monoenergetic and polyenergetic x-ray spectra in the mammographic energy range. The characteristic feature in the electron energy distributions for PbI(2) and HgI(2) is the atomic deexcitation peaks, whereas for the rest of the materials their shape can also be influenced by the electrons produced from primary photons. The electrons have a small tendency to be forward ejected whereas they prefer to be ejected perpendicular (theta = pi/2) to the incident beam's axis and at two lobes around phi = 0 and phi = pi. At practical mammographic energies (15-40 keV) a-Se, a-As(2)Se(3) and Ge have the minimum azimuthal uniformity whereas CdZnTe, Cd(0.8)Zn(0.2)Te and CdTe the maximum one. The spatial distributions for a-Se, a-As(2)Se(3), GaSe, GaAs, Ge, PbO and TlBr are almost independent of the polyenergetic spectrum, while those for CdTe, CdZnTe, Cd(0.8)Zn(0.2)Te, ZnTe, PbI(2) and HgI(2) have a spectrum dependence. In the practical mammographic energy range and at this primitive stage of primary electron production, a-Se has the best inherent spatial resolution as compared to the rest of the photoconductors. PbO has the minimum bulk space in which electrons can be produced whereas CdTe has the maximum one.


Subject(s)
Mammography/instrumentation , Mammography/methods , Computer Simulation , Electrons , Humans , Light , Models, Statistical , Monte Carlo Method , Phantoms, Imaging , Photons , Probability , Radiographic Image Enhancement , Reproducibility of Results , Scattering, Radiation , X-Rays
3.
Phys Med Biol ; 52(11): 3185-99, 2007 Jun 07.
Article in English | MEDLINE | ID: mdl-17505097

ABSTRACT

Magnification views are a common way to perform a secondary examination when suspicious abnormalities are found in a screening mammogram. The visibility of microcalcifications and breast lesions is restricted by the compromise between the image quality and the absorbed dose. In this study, image quality characteristics in magnification mammography were evaluated based on Monte Carlo techniques. A breast phantom was utilized, simulating a homogeneous mixture of adipose and glandular tissue in various percentages of glandularity, containing inhomogeneities of various sizes and compositions. The effect of the magnification degree, breast glandularity, tube voltage and anode/filter material combination on image quality characteristics was investigated in terms of a contrast-to-noise ratio (CNR). A performance index PI(nu) was introduced in order to study the overall performance of various anode/filter combinations under different exposure parameters. Results demonstrate that CNR is improved with the degree of magnification and degraded as the breast glandularity is increased. Degree of magnification 1.3 offers the best overall performance for most of the anode/filter combinations utilized. Under magnification conditions, the role of dose is demoted against the image quality, as magnification views are secondary, diagnostic examinations and not screening procedures oriented to non-symptomatic women. For decreased image quality weighting, some anode/filter combinations different from Mo/0.030 mmMo can be utilized as they offer a similar performance index. However, if the desired weighting for the image quality is high, the Mo/0.030 mmMo combination has the best overall performance.


Subject(s)
Breast Neoplasms/radiotherapy , Mammography/instrumentation , Mammography/methods , Breast/pathology , Female , Humans , Image Processing, Computer-Assisted , Models, Statistical , Models, Theoretical , Monte Carlo Method , Phantoms, Imaging , Radiation Dosage , Radiographic Image Enhancement , Radiographic Image Interpretation, Computer-Assisted , Reproducibility of Results , X-Ray Intensifying Screens
4.
Med Phys ; 33(11): 4221-35, 2006 Nov.
Article in English | MEDLINE | ID: mdl-17153401

ABSTRACT

Mammography is the technique with the highest sensitivity and specificity, for the early detection of nonpalpable lesions associated with breast cancer. As screening mammography refers to asymptomatic women, the task of optimization between the image quality and the radiation dose is critical. A way toward optimization could be the introduction of new anode materials. A method for producing the x-ray spectra of different anode/filter combinations is proposed. The performance of several mammographic spectra, produced by both existing and theoretical anode materials, is evaluated, with respect to their dose and subject contrast characteristics, using a Monte Carlo simulation. The mammographic performance is evaluated utilizing a properly designed mathematical phantom with embedded inhomogeneities, irradiated with different spectra, based on combinations of conventional and new (Ru, Ag) anode materials, with several filters (Mo, Rh, Ru, Ag, Nb, Al). An earlier developed and validated Monte Carlo model, for deriving both image and dose characteristics in mammography, was utilized and overall performance results were derived in terms of subject contrast to dose ratio and squared subject contrast to dose ratio. Results demonstrate that soft spectra, mainly produced from Mo, Rh, and Ru anodes and filtered with k-edge filters, provide increased subject contrast for inhomogeneities of both small size, simulating microcalcifications and low density, simulating masses. The harder spectra (W and Ag anode) come short in the discrimination task but demonstrate improved performance when considering the dose delivered to the breast tissue. As far as the overall performance is concerned, new theoretical spectra demonstrate a noticeable good performance that is similar, and in some cases better compared to commonly used systems, stressing the possibility of introducing new materials in mammographic practice as a possible contribution to its optimization task. In the overall optimization task in terms of subject contrast to dose ratio, tube voltage was found to have a minor effect, while with respect to the filter material, a lesion specific performance was noticed, with Al filtered spectra showing improved characteristics in case of the inhomogeneities simulating microcalcifications, while softer k-edge filtered spectra are more suitable for the discrimination of inhomogeneities simulating masses.


Subject(s)
Electrodes , Information Storage and Retrieval/methods , Mammography/instrumentation , Radiographic Image Enhancement/instrumentation , Radiographic Image Interpretation, Computer-Assisted/instrumentation , Radiographic Image Interpretation, Computer-Assisted/methods , Computer Simulation , Equipment Design , Equipment Failure Analysis , Mammography/methods , Materials Testing , Models, Biological , Models, Statistical , Monte Carlo Method , Reproducibility of Results , Sensitivity and Specificity
5.
Phys Med Biol ; 51(21): 5539-48, 2006 Nov 07.
Article in English | MEDLINE | ID: mdl-17047268

ABSTRACT

Magnification mammography is a special technique used in the cases where breast complaints are noted by a woman or when an abnormality is found in a screening mammogram. The carcinogenic risk in mammography is related to the dose deposited in the glandular tissue of the breast rather than the adipose, and average glandular dose (AGD) is the quantity taken into consideration during a mammographic examination. Direct measurement of the AGD is not feasible during clinical practice and thus, the incident air KERMA on the breast surface is used to estimate the glandular dose, with the help of proper conversion factors. Additional conversion factors adapted for magnification and tube voltage are calculated, using Monte Carlo simulation. The effect of magnification degree, tube voltage, various anode/filter material combinations and glandularity on AGD is also studied, considering partial breast irradiation. Results demonstrate that the estimation of AGD utilizing conversion factors depends on these parameters, while the omission of correction factors for magnification and tube voltage can lead to significant underestimation or overestimation of AGD. AGD was found to increase with filter material's k-absorption edge, anode material's k-emission edge, tube voltage and magnification. Decrease of the glandularity of the breast leads to higher AGD due to the increased penetrating ability of the photon beam in thick breasts with low glandularity.


Subject(s)
Mammography/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Air , Breast/pathology , Breast Neoplasms/diagnosis , Breast Neoplasms/diagnostic imaging , Humans , Mammography/instrumentation , Mass Screening , Models, Theoretical , Monte Carlo Method , Radiation Dosage , Radiographic Image Enhancement , X-Ray Intensifying Screens
6.
Phys Med Biol ; 50(16): 3717-38, 2005 Aug 21.
Article in English | MEDLINE | ID: mdl-16077223

ABSTRACT

Selenium is among the materials under investigation that may form effective detectors and provide a major contribution to digital mammography. Till the final image formation, there is an intervention of the x-ray photons transformation to primary electrons and their subsequent ionizing drift towards the electrodes that collect them. The characteristics of the generated primary electrons inside a-Se material such as their angular, spatial and energy distribution affect the characteristics of the final image. A Monte Carlo based model has been developed that simulates the x-ray irradiation of an a-Se detector plate, including primary photon interactions (photoelectric absorption, coherent and incoherent scattering), as well as secondary ones, such as fluorescence (Kalpha, Kbeta) and emission of Auger electrons. The angular, spatial and energy distributions for the generated primary electrons inside a-Se have been produced for various mammographic x-ray spectra and their usefulness in designing and optimizing a detector made of a-Se for digital mammography is discussed.


Subject(s)
Mammography/instrumentation , Mammography/methods , Selenium/chemistry , Algorithms , Electrons , Humans , Monte Carlo Method , Phantoms, Imaging , Photons , Radiation , Radiographic Image Enhancement , Scattering, Radiation , Spectrometry, X-Ray Emission , Spectrophotometry , X-Ray Intensifying Screens , X-Rays
7.
Eur J Radiol ; 54(3): 371-6, 2005 Jun.
Article in English | MEDLINE | ID: mdl-15899338

ABSTRACT

Dosimetric studies in mammography are addressed by means of a Monte Carlo simulation program. The core of this program (DOSIS: dosimetry simulation studies) is a simulation model developed using FORTRAN 90, enriched with a graphical user interface developed in MS Visual Basic. User defined mammographic technique parameters affecting breast dose are imported to the simulation model and the produced results are provided by means of both absolute (surface dose, exposure at detector plane) and relative quantities (percentage depth dose, isodose curves). The program functionality has been demonstrated in the evaluation of various mammographic examination techniques. Specifically, the influence of tube voltage and filtration on the surface dose and the exposure at detector plane has been studied utilizing a water phantom. Increase of tube voltage from 25 to 30 kVp for a Mo/Mo system resulted in a 42% decrease of the surface dose for a thick breast (6 cm), without changing the exposure at the detector plane. Use of 1.02 mm Al filter for a W anode system operating at 30 kVp resulted in a 19.1% decrease of the surface dose delivered to a 5 cm water equivalent breast. Overall, W/Al systems appear to have improved dosimetric performance, resulting up to a 65% decrease of surface dose compared to Mo/Mo systems, for identical exposures at the detector plane and breast thicknesses.


Subject(s)
Breast Diseases/diagnostic imaging , Mammography/instrumentation , Monte Carlo Method , Algorithms , Female , Humans , Phantoms, Imaging , Radiation Dosage , Software , User-Computer Interface
8.
Phys Med Biol ; 47(6): 917-33, 2002 Mar 21.
Article in English | MEDLINE | ID: mdl-11936178

ABSTRACT

A simulation model of mammographic x-ray sources with finite size has been developed. The model is based on Monte Carlo methods and it takes into account the electron penetration inside the anode, the anode geometry and material, as well as the resulting heel effect and the spectral and spatial distribution of x-rays. This x-ray source simulation model has been embedded into an earlier developed simulation package of a mammography unit. The main outputs of this model are Monte Carlo generated images that correspond to the irradiation of properly designed phantoms. In this way it is possible to make studies of the influence of x-ray source characteristics on MTF. This paper presents the development of the mammographic x-ray source model, accompanied by a set of simulation studies concerning the influence of magnification effects as well as that of the x-ray spatial and spectral distribution on the mammographic spatial resolution for a certain magnification factor (m = 1.4). The validity level of the model, as well as its limitations and perspectives, rise through comparisons with experimental and theoretical data.


Subject(s)
Mammography/methods , X-Rays , Algorithms , Female , Humans , Monte Carlo Method , Normal Distribution , Phantoms, Imaging
9.
Med Inform Internet Med ; 25(4): 275-93, 2000.
Article in English | MEDLINE | ID: mdl-11198189

ABSTRACT

Mammography is a high quality imaging technique for the detection of breast lesions, which requires dedicated equipment and optimum operation. The design parameters of a mammography unit have to be decided and evaluated before the construction of such a high cost of apparatus. The optimum operational parameters also must be defined well before the real breast examination. MASTOS is a software package, based on Monte Carlo methods, that is designed to be used as a simulation tool in mammography. The input consists of the parameters that have to be specified when using a mammography unit, and also the parameters specifying the shape and composition of the breast phantom. In addition, the input may specify parameters needed in the design of a new mammographic apparatus. The main output of the simulation is a mammographic image and calculations of various factors that describe the image quality. The Monte Carlo simulation code is PC-based and is driven by an outer shell of a graphical user interface. The entire software package is a simulation tool for mammography and can be applied in basic research and/or in training in the fields of medical physics and biomedical engineering as well as in the performance evaluation of new designs of mammography units and in the determination of optimum standards for the operational parameters of a mammography unit.


Subject(s)
Computer Simulation , Mammography/standards , Software , Algorithms , Computer Graphics , Data Display , Equipment Design , Female , Humans , Mammography/instrumentation , Monte Carlo Method , Phantoms, Imaging , Software Design , User-Computer Interface
10.
Phys Med Biol ; 43(11): 3341-57, 1998 Nov.
Article in English | MEDLINE | ID: mdl-9832020

ABSTRACT

We have developed a model using Monte Carlo methods to simulate x-ray mammography. All possible physical processes of interaction of x-rays with matter have been taken into account. A simplified geometry of the mammographic apparatus has been considered along with a software phantom of compressed breast. The phantom may contain inhomogeneities of various compositions and sizes. We have used this model to produce Monte Carlo mammograms under realistic conditions. The validation of the simulation includes both the modelling of physical processes and the production of Monte Carlo mammograms. The first part is accomplished by the demonstration of the coincidence between Monte Carlo and theoretical data, whereas the second is accomplished by the comparison of real mammograms, taken from irradiation of a simplified breast phantom that we have constructed, and Monte Carlo mammograms taken from simulation of the above phantom under the corresponding exposure conditions. The limitations of the model as well as the future use of Monte Carlo mammograms are discussed.


Subject(s)
Mammography/methods , Monte Carlo Method , Biophysical Phenomena , Biophysics , Breast Neoplasms/diagnostic imaging , Female , Humans , Mammography/statistics & numerical data , Models, Biological , Phantoms, Imaging , Photons , Radiographic Image Interpretation, Computer-Assisted/methods , Reproducibility of Results , Scattering, Radiation , Software