Publication year range
1.
Appl Radiat Isot ; 134: 200-204, 2018 Apr.
Article in English | MEDLINE | ID: mdl-28690097

ABSTRACT

At the JRC-Geel's RadioNuclide Metrology sector, a Monte Carlo code based on EGSnrc, and a general purpose calculation sheet implemented in Microsoft Excel®, have been developed to make the quantitative gamma-ray spectrometry analysis of samples simpler and more robust. The further aim is that the software can be used by non-experts in gamma-ray spectrometry e.g. external researchers using JRC-Geel's facilities through the EUFRAT transnational access scheme. This paper presents the developed Monte Carlo software and the functionality included in the calculation sheet.

2.
Appl Radiat Isot ; 130: 252-259, 2017 Dec.
Article in English | MEDLINE | ID: mdl-29040881

ABSTRACT

This paper addresses the measurement facilities for pre-selection of waste materials prior to measurement for repository acceptance or possible free release (segregation measurement system); and free release (free release measurement system), based on a single standardized concept characterized by unique, patented lead-free shielding. The key objective is to improve the throughput, accuracy, reliability, modularity and mobility of segregation and free-release measurement. This will result in a more reliable decision-making with regard to the safe release and disposal of radioactive wastes into the environment and, resulting in positive economic outcomes. The research was carried out within "Metrology for Decommissioning Nuclear Facilities" (MetroDecom) project.

3.
Appl Radiat Isot ; 126: 296-299, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28109700

ABSTRACT

A measurement station dedicated for quantitative radiological characterisation of naturally occurring radionuclides in a metallurgical company and based on gamma-ray spectrometry was developed. The station is intended for performing quality control of final non-ferrous metal products and for radiological checks of incoming materials. A low-background point-contact HPGe-detector was used and the signal was split in two branches to enable collecting simultaneously spectra with high amplification (for gamma-ray energies below 250keV) and low amplification.

4.
Appl Radiat Isot ; 109: 435-440, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26682891

ABSTRACT

Following the accident at the Fukushima Daiichi nuclear power plant, a campaign of sampling and measuring anthropogenic radionuclides in North Pacific seawater was set up. The main aim was to study natural processes using these radionuclides as tracers. Because of dilution, the activities of anthropogenic radionuclides at long range were very low and their measurement required advanced pre-concentration techniques and underground gamma-ray spectrometry. Data and metrological aspects of the measurements using HPGe-detectors are presented and discussed.


Subject(s)
Biological Assay/methods , Fukushima Nuclear Accident , Plankton/chemistry , Radioisotopes/analysis , Radiometry/methods , Seawater/chemistry , Water Pollutants, Radioactive/analysis , Environmental Monitoring/methods , Pacific Ocean , Reproducibility of Results , Sensitivity and Specificity , Spectrometry, Gamma/methods
5.
Radiat Prot Dosimetry ; 168(3): 293-9, 2016 Mar.
Article in English | MEDLINE | ID: mdl-25977349

ABSTRACT

A new large-volume metal reference standard has been developed. The intended use is for calibration of free-release radioactivity measurement systems and is made up of cast iron tubes placed inside a box of the size of a Euro-pallet (80 × 120 cm). The tubes contain certified activity concentrations of (60)Co (0.290 ± 0.006 Bq g(-1)) and (110m)Ag (3.05 ± 0.09 Bq g(-1)) (reference date: 30 September 2013). They were produced using centrifugal casting from a smelt into which (60)Co was first added and then one piece of neutron irradiated silver wire was progressively diluted. The iron castings were machined to the desirable dimensions. The final material consists of 12 iron tubes of 20 cm outer diameter, 17.6 cm inner diameter, 40 cm length/height and 245.9 kg total mass. This paper describes the reference standard and the process of determining the reference activity values.


Subject(s)
Cobalt Radioisotopes/analysis , Radiation Monitoring/methods , Radioactive Waste/analysis , Silver/analysis , Waste Management/standards , Humans , Reference Standards
6.
Appl Radiat Isot ; 87: 336-41, 2014 May.
Article in English | MEDLINE | ID: mdl-24332343

ABSTRACT

The aim of the study was to check for equivalence of computer codes that can perform calculations of true coincidence summing correction factors. All calculations were performed for a set of well-defined detector and sample parameters, without any reference to empirical data. For a p-type detector model the application of different codes resulted in satisfactory agreement in the calculated correction factors. For high-efficiency geometries in combination with an n-type detector and a radionuclide emitting abundant X-rays the results were scattered.

7.
Radiat Prot Dosimetry ; 144(1-4): 632-5, 2011 Mar.
Article in English | MEDLINE | ID: mdl-21051436

ABSTRACT

The aim of the study was to control occupational exposure during the removal of radioactive reactor components from a Greek research reactor pool. The method comprised the prediction of the radiation levels, the design of special shielding structures and the occupational dose assessment. Activation calculations were performed using the FISPACT code to predict the source term. Monte Carlo simulations using MCNP code were utilized to estimate the ambient dose equivalent rates. The results of the calculations were verified by measurements and were found to be in good agreement. Thermoluminescence dosemeter (TLD) and electronic personal dosemeter (EPD) were implemented to measure the radiation exposure of the workers. The total collective dose of 14 participating workers was 0.15 man mSv. The maximum individual effective dose was 0.02 mSv, and the maximum extremity equivalent dose was 0.09 mSv. The discussed method provides a useful tool enabling work planning during reactor decommissioning and renovation activities ensuring that exposures will be maintained ALARA.


Subject(s)
Occupational Exposure/prevention & control , Radiation Monitoring/instrumentation , Radiation Monitoring/methods , Radiation Protection/methods , Radiometry/instrumentation , Thermoluminescent Dosimetry/instrumentation , Computer Simulation , Equipment Design , Humans , Materials Testing , Monte Carlo Method , Neutrons , Nuclear Reactors , Radiation Dosage , Radioisotopes/analysis , Radiometry/methods , Thermoluminescent Dosimetry/methods
8.
Appl Radiat Isot ; 68(2): 355-9, 2010 Feb.
Article in English | MEDLINE | ID: mdl-19892558

ABSTRACT

Four general Monte Carlo codes (GEANT3, PENELOPE, MCNP and EGS4) and five dedicated packages for efficiency determination in gamma-ray spectrometry (ANGLE, DETEFF, GESPECOR, ETNA and EFFTRAN) were checked for equivalence by applying them to the calculation of efficiency transfer (ET) factors for a set of well-defined sample parameters, detector parameters and energies typically encountered in environmental radioactivity measurements. The differences between the results of the different codes never exceeded a few percent and were lower than 2% in the majority of cases.


Subject(s)
Algorithms , Radiometry/instrumentation , Radiometry/methods , Software , Equipment Design , Equipment Failure Analysis , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS