Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Arch Craniofac Surg ; 19(2): 148-151, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29996642

ABSTRACT

The nose is an important landmark of the face and its shape and beauty is of significant concern. The columella is the subunit between the two nostrils that provides support and projection to the nasal tip and has functional role in nostrils, as well as aesthetic. Ethiology for columellar absence or deficiency is diverse, and it is one of the most complex nasal subunits to reconstruct because of its narrow horizontal dimension, its tenuous vascularity and limited availability of adjacent tissue. We present a patient with columellar, membranous septum and upper lip defect, due to oncological resection. The lip reconstruction was designed using advancement of two upper lip edges with the technique of webster perialar/nasocheek advancement. However, the perialar/nasocheek tissue which is usually discarded was used as inferiorly based skin flaps to reconstruct the membranous septum, columellar skin and nasal vestibule lining. Rib cage cartilage graft was used as columellar strut for support. At 1-year followup, the patient has good nasal contour and projection. Scaring of the columella is very subtle. This is a versatile way for successful reconstruction of a columella and large central facial defect in one-stage operation. It is a method which provides very satisfactory aesthetic result with minimum patient morbidity and discomfort.

2.
J Glaucoma ; 24(6): 410-6, 2015 Aug.
Article in English | MEDLINE | ID: mdl-24633088

ABSTRACT

PURPOSE: The aim of this study was to compare the efficacy and safety between standard trabeculectomy and the Ex-PRESS shunt implantation. METHODS: A retrospective review of the records of 100 eyes of 100 patients who underwent trabeculectomy or Ex-PRESS shunt implantation between July 2010 and June 2012 was conducted. Of these, 61 (61%) eyes underwent trabeculectomy and 39 (39%) eyes underwent Ex-PRESS shunt implantation. Demographic information, glaucoma type, surgical details, preoperative, and postoperative data including intraocular pressure (IOP), number of medications, reoperation, and occurrence of any complications were recorded. RESULTS: No differences in IOP reduction or number of postoperative IOP-lowering medications were demonstrated between the 2 procedures. Success rates were 86.9% for trabeculectomy and 84.6% for Ex-PRESS shunt. Rates of failure and hypotony were not significantly different between the groups. No parameter was correlated with success or failure of any procedure. CONCLUSIONS: Standard trabeculectomy and Ex-PRESS shunt have similar efficacy and safety profiles. As the Ex-PRESS shunt is considerably more expensive, its use may be unjustified, especially as a primary procedure.


Subject(s)
Glaucoma Drainage Implants , Glaucoma/surgery , Trabeculectomy/methods , Adult , Aged , Aged, 80 and over , Antihypertensive Agents/therapeutic use , Female , Glaucoma/drug therapy , Glaucoma/physiopathology , Humans , Intraocular Pressure/drug effects , Intraocular Pressure/physiology , Male , Middle Aged , Prosthesis Implantation , Retrospective Studies , Tonometry, Ocular
SELECTION OF CITATIONS
SEARCH DETAIL
...