1.
J Synchrotron Radiat ; 8(3): 1021-6, 2001 May 01.
Article in English | MEDLINE | ID: mdl-11486407

ABSTRACT

X-ray polarization-contrast images resulting from X-ray magnetic circular dichroism (XMCD) in the hard X-ray region have been successfully recorded for the first time. The apparatus used consisted of an X-ray polarizer, double X-ray phase retarders, and a high-spatial-resolution X-ray charge-coupled-device detector. The sample used was a hexagonal-close-packed cobalt polycrystal foil having a thickness of about 4 microns. The X-ray polarization-contrast image resulting from XMCD was observed at a photon energy of 10 eV above the cobalt K-absorption edge (7709 eV). The observed contrast in the image was reversed by inversion of the magnetic field. Furthermore, the contrast was reversed again at a photon energy of 32 eV above the cobalt K-absorption edge.


Subject(s)
Circular Dichroism , Signal Processing, Computer-Assisted , Magnetics , X-Rays
2.
J Synchrotron Radiat ; 8(1): 33-7, 2001 Jan 01.
Article in English | MEDLINE | ID: mdl-11486494

ABSTRACT

An X-ray double phase retarder system composed of two transmission-type phase retarders is proposed and developed in order to compensate for off-axis aberration (phase-shift inhomogeneity due to angular divergence of incident X-rays). The scattering planes of the two phase retarders are set to be inclined by 45 degrees with respect to the plane of incident polarization, but the two phase retarders give Bragg reflections in opposite directions. By using this X-ray optical system, vertically polarized X-rays with a 0.99 degree of linear polarization were obtained from horizontally polarized synchrotron radiation with a horizontal beam divergence of 20 arcsec (0.1 mrad). This value is favorably compared with the value of 0.87 which was obtained using a conventional single phase retarder of identical total thickness, 627 microns. The comparison was made at the nickel K-absorption edge (8333 eV) with the condition that 47% of incident X-rays were transmitted through the two phase retarder crystals. The crystals were (100)-oriented diamond plates giving asymmetric 111 Laue reflections.

3.
J Synchrotron Radiat ; 7(Pt 6): 368-73, 2000 Nov 01.
Article in English | MEDLINE | ID: mdl-16609223

ABSTRACT

X-ray polarization-contrast images resulting from X-ray linear dichroism (XLD) in the hard X-ray region have been successfully recorded for the first time. The apparatus used consisted of an X-ray polarizer, double X-ray phase retarders and a high-spatial-resolution X-ray charge-coupled device (CCD) detector. The sample used was a hexagonal close packed (h.c.p.) cobalt single-crystal foil of thickness about 12 microm. The experiment was performed at X-ray energies of 23 and 29 eV above the cobalt K edge (7709 eV), at which the maximum linear dichroisms (approximately 3%) were observed, with their signs reversed, in the XLD spectrum measured with quadruple X-ray phase retarders. The contrasts in the images at the two X-ray energies were reversed as a result of the XLD in the sample. Furthermore, the values of the contrast in the images arising from the linear dichroism (approximately 3%) were in good agreement with those yielded by the XLD spectrum.

4.
Acta Crystallogr A ; 55(Pt 5): 955-962, 1999 Sep 01.
Article in English | MEDLINE | ID: mdl-10927305

ABSTRACT

The possibility of a transmission-type X-ray linear polarizer is investigated using a thin Bragg reflector as a polarizing filter. In this device, the transmitted beam (rather than the Bragg-reflected beam) is the useful output of the device. Consequently, the position and the direction of the transmitted beam are unchanged as the energy is changed, or even when the polarization direction to be filtered out is changed. Theoretical considerations as well as preliminary transmissivity measurements are presented. The use of perfect crystals of silicon and diamond is examined. A polarization ratio, defined as I(H)/I(V), higher than 10(5) was observed in experiments to measure the performance characteristics of the proposed X-ray polarizing reflector. The transmission-type X-ray linear polarizer is well suited for spectroscopic measurements with polarized X-rays.

5.
J Synchrotron Radiat ; 5(Pt 3): 738-40, 1998 May 01.
Article in English | MEDLINE | ID: mdl-15263637

ABSTRACT

Even though conventional X-ray polarizers with multiple-reflection channel-cut structures perform well, they suffer from the disadvantage that the polarized beam is non-stationary as the energy is scanned. In this paper the possibility of using a thin Bragg reflector as a polarizing filter is investigated, so that the transmitted beam (rather than the Bragg-reflected beam) is used. Consequently, the position and direction of the transmitted beam are unchanged as the energy is changed, or even when the polarization direction to be filtered out is changed. Theoretical considerations as well as experimental results on the performance characteristics of the proposed transmission-type X-ray linear polarizer are presented. A polarization ratio, defined as I(H)/I(V), higher than 10(5) was obtained.

6.
J Synchrotron Radiat ; 5(Pt 3): 1055-7, 1998 May 01.
Article in English | MEDLINE | ID: mdl-15263743

ABSTRACT

X-ray triple refraction and triple absorption have been quantitatively measured for the first time. The samples were (100)-, (010)- and (001)-oriented plates of a cobalt-complex monoclinic crystal. The apparatus used was an energy-tunable X-ray polarimeter with a phase retarder. The X-ray energy was scanned over a range of 150 eV near the cobalt K-absorption edge. Both the spectra of ellipticity and rotation of polarization were completely different for each crystal plate, which revealed that the biaxial crystal had three refractive indices and three absorption coefficients in the X-ray region. The Kramers-Kronig relation between the real and imaginary parts of the dielectric anisotropy has been quantitatively confirmed for all three different orientations.