Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-38991770

ABSTRACT

BACKGROUND AND PURPOSE: A single aspiration maneuver using a large volume syringe is a common and effective technique for aspiration thrombectomy. Multiple aspiration cycles using large aspiration syringes has been proposed as a means to improve efficacy over single aspiration. In this study, we sought to investigate the efficacy of a "triple aspiration technique" where a large volume syringe is cycled three times prior to catheter retraction during aspiration thrombectomy. MATERIALS AND METHODS: A 3D-printed adult vasculature was used as a benchtop thrombectomy platform. Fibrin-rich and red blood cell-rich clots were prepared in centrifuge tubes using human plasma, red blood cells, and calcium chloride. Next, clots were placed in the carotid terminus of the model, and the performances of three different aspiration techniques-triple syringe, single syringe, and continuous pump aspiration-were compared in a randomized manner (1:1:1). Outcomes of interest included first-pass efficacy (FPE), complete clot removal (final mTICI 2c/3), the number of thrombectomy attempts to achieve mTICI 2c/3, vacuum pressure, and distal embolization. The distal emboli were detected using a 70-micron cell strainer placed at the outflow of the model and quantified using an image processing algorithm. The vacuum pressures were measured using a pressure transducer (Honeywell, NC, USA). RESULTS: A total of 102 replicates were performed, 34 for each technique. The triple aspiration technique provided a significantly higher rate of FPE than the syringe and pump aspiration techniques (67.6% vs. 41.1%, p= 0.02). Additionally, the triple aspiration technique achieved complete clot removal with a significantly lower number of thrombectomy attempts compared to single syringe aspiration (1.2 ± 0.5 vs. 1.8 ± 0.8, p=0.005). The triple aspiration technique generated significantly higher vacuum pressure than both the single syringe and vacuum pump aspiration (28.3 ± 0.2 vs. 27.2 ± 0.3 (p= 0.002) and 26.2 ± 0.4 (p=0.001), respectively). The differences in complete clot removal and distal embolization parameters were not statistically significantly different across the groups. CONCLUSIONS: Our findings suggest that the triple aspiration technique can improve FPE rates and vacuum pressure in aspiration thrombectomy. Further studies are needed to examine the safety and efficacy of triple aspiration in the clinical setting. ABBREVIATIONS: AcommA = anterior communicating artery; FPE = first pass efficacy; ICA = internal carotid artery; MCA = middle cerebral artery; MT = mechanical thrombectomy; mTICI = modified thrombolysis in cerebral infarction scale; PcommA = posterior communicating artery.

2.
J Neurointerv Surg ; 2024 Jun 11.
Article in English | MEDLINE | ID: mdl-38862208

ABSTRACT

The New Zealand rabbit elastase-induced arterial aneurysm of the right common carotid artery remains a widely used model for assessing the effectiveness and safety of new neuroendovascular devices.1 This model offers a simple and reliable platform for pre-clinical in vivo investigations, crucial for comprehending the biological processes underlying aneurysm healing after endovascular treatment.2 Notably, the induced aneurysm exhibits morphological, hemodynamic, and histological characteristics similar to human intracranial aneurysms. The creation of the aneurysm is performed using open and endovascular techniques. Each step of the procedure requires a meticulous and controlled gesture to ensure reproducibility of the aneurysm and minimize animal misuse. In video 1 we present a step-by-step procedural guide for aneurysm creation and follow-up. We hope this resource will help in promoting this model and provide useful guidance for researchers in the field.neurintsurg;jnis-2024-021912v1/V1F1V1Video 1Surgical procedure of creating elastase-induced aneurysms in rabbits.

3.
Surg Neurol Int ; 14: 228, 2023.
Article in English | MEDLINE | ID: mdl-37404491

ABSTRACT

Background: Cerebrospinal fluid (CSF) rhinorrhea with meningoencephalocele (MEC) associated with Sternberg's canal is rare. We treated two such cases. Case Description: A 41-year-old man and a 35-year-old woman presented with CSF rhinorrhea and mild headache worsening with standing posture. Head computed tomography showed a defect close to the foramen rotundum in the lateral wall of the left sphenoid sinus in both cases. Head magnetic resonance (MR) imaging and MR cisternography revealed that brain parenchyma had herniated into the lateral sphenoid sinus through the defect of the middle cranial fossa. The intradural and extradural spaces and bone defect were sealed with fascia and fat through both intradural and extradural approaches. The MEC was cut away to prevent infection. CSF rhinorrhea completely stopped after the surgery. Conclusion: Our cases were characterized by empty sella, thinning of the dorsum sellae, and large arteriovenous malformations that suggest chronic intracranial hypertension. The possibility of Sternberg's canal in patients with CSF rhinorrhea with chronic intracranial hypertension should be considered. The cranial approach has the advantages of lower infection risk and the ability to close the defect with multilayer plasty under direct vision. The transcranial approach is still safe if performed by a skillful neurosurgeon.

SELECTION OF CITATIONS
SEARCH DETAIL
...