Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 23
Filter
1.
J Med Case Rep ; 18(1): 285, 2024 Jun 21.
Article in English | MEDLINE | ID: mdl-38902817

ABSTRACT

BACKGROUND: An aortoesophageal fistula can prove to be fatal. Salvage thoracic endovascular aortic repair as a bridging therapy and radical surgery with thoracotomy should be considered while treating aortoesophageal fistula without spontaneous closure. Moreover, it is essential to select a technique that reduces the risk of reinfection. Here we report a rare case of a ruptured thoracic aortic aneurysm related to esophageal perforation by a fish bone that led to massive hematemesis and shock, and the surgical treatment of an aortoesophageal fistula that developed after salvage thoracic endovascular aortic repair. CASE PRESENTATION: A 70-year-old Japanese female patient was admitted with hematemesis, thoracic pain, and shock related to esophageal perforation of a ruptured descending aortic aneurysm caused by fish bone aspiration and esophageal perforation 1 month previously. An emergency thoracic endovascular aortic repair was performed. Postoperatively, an aortoesophageal fistula that remained open and a food intake-related increase in the inflammatory response was noted. Radical blood-vessel prosthesis implantation and fistula closure were performed. The patient's postoperative course was favorable and the patient was discharged 22 days after the blood vessel prosthesis implantation. CONCLUSION: Such a case of rupture of a descending aortic aneurysm related to perforation by a fish bone and an aortoesophageal fistula is considerably rare. Thus, we report the therapeutic strategy of this particular case and review the relevant literature.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Rupture , Endovascular Procedures , Esophageal Fistula , Esophageal Perforation , Humans , Female , Esophageal Fistula/surgery , Esophageal Fistula/etiology , Aged , Endovascular Procedures/methods , Aortic Aneurysm, Thoracic/surgery , Aortic Rupture/surgery , Esophageal Perforation/surgery , Esophageal Perforation/etiology , Vascular Fistula/surgery , Vascular Fistula/etiology , Blood Vessel Prosthesis Implantation , Salvage Therapy/methods , Animals , Hematemesis/etiology , Aortic Diseases/surgery , Aortic Diseases/etiology , Aorta, Thoracic/surgery , Treatment Outcome , Fishes , Endovascular Aneurysm Repair
3.
Ann Vasc Surg ; 82: 294-302, 2022 May.
Article in English | MEDLINE | ID: mdl-34788707

ABSTRACT

BACKGROUND: This study was aimed to evaluate the outcomes of performing open repair or thoracic endovascular aortic repair for chronic type B dissecting aortic aneurysm. METHODS: From July 2004 to February 2019, 52 patients underwent surgery as open repair (n = 32) or endovascular repair (n = 20) for chronic type B dissecting aortic aneurysm. Replacement of the aorta was limited to the aneurysmal portion with or without reconstructing the visceral arteries or the segmental arteries. Stent grafts were deployed in the true lumen above the celiac artery to cover the primary entry for even DeBakey IIIb dissection. RESULTS: Operative mortality and morbidity rates, including spinal cord ischemia incidence, did not differ between the groups. Operative mortality and morbidity rates, including spinal cord ischemia incidence, did not differ between the groups. In the endovascular repair group, 3 patients died due to rupture of residual false lumen in the early, and late postoperative follow-up. The 5-year rate of freedom from all-cause death, aorta-related death, and aorta-related event were 84% ± 6%, 94% ± 3% and 84% ± 6%. The endovascular repair was independently associated with all-cause death (hazard ratio [HR], 5.7; confidence interval [CI], 1.02-31.6; P = 0.04) and aorta-related event (HR, 30.9; CI 4.9-195.0; P < 0.001). In the open group, postoperative residual aortic diameter was an independent predictor of aorta-related events, and the threshold was 41 mm. CONCLUSIONS: Open repair remains a better option than simple endovascular repair alone in DeBakey IIIb dissection, but the distal un-resected aortic portion over 41 mm was associated with late aortic events.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Aneurysm , Aortic Dissection , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Spinal Cord Ischemia , Aortic Dissection/diagnostic imaging , Aortic Dissection/surgery , Aortic Aneurysm/diagnostic imaging , Aortic Aneurysm/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Disease Progression , Endovascular Procedures/adverse effects , Humans , Retrospective Studies , Spinal Cord Ischemia/surgery , Stents , Time Factors , Treatment Outcome
4.
J Cardiol Cases ; 24(6): 307-309, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34917217

ABSTRACT

Cardiac perforation is a rare but serious and life-threatening complication of permanent pacemaker implantation, with an incidence of 0.1-6%. Surgery is usually performed through a median sternotomy; however, sternotomy-related morbidity remains a concern. Herein, we report a case of surgical repair performed via a left mini-thoracotomy for a right ventricular perforation caused by implantation of a permanent pacemaker lead in a 56-year-old woman. Through the left fifth intercostal space, the pacemaker lead was observed to have penetrated the left ventricular myocardium, reaching the pericardium. The lead had passed through the right ventricle and the inferior ventricular septum and protruded from the left ventricular myocardium. After pacemaker lead removal, a dark blow-out type hemorrhage occurred; hence, repair was performed using a pair of pledgeted Mattress sutures. In conclusion, left mini-thoracotomy provides an adequate surgical field and has less impact on hemodynamics when operating at the cardiac apex. .

5.
Clin Case Rep ; 9(12): e05126, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34917364

ABSTRACT

In patients with a narrow sinotubular junction, small sinus of Valsalva, or extensibility loss in the aortic root, aortic valve replacement (AVR) with a standard valve is challenging due to limited surgical field. Detailed preoperative measurements of the aortic root render performing AVR using the Perceval valve easy.

6.
Ann Thorac Surg ; 112(2): e119-e121, 2021 08.
Article in English | MEDLINE | ID: mdl-33444579

ABSTRACT

A 25-year-old man presented with palpitations and subsequently received a diagnosis of a large epicardial cyst (6.8 × 3.8 cm) originating from the left ventricle. The cyst compressed the left atrium and ventricle and led to left ventricular diastolic dysfunction. Contrast-enhanced chest computed tomography revealed that the circumflex artery passed over or through the cyst. We successfully resected the cyst without using cardiopulmonary bypass through a left mini-thoracotomy with thoracoscopic assistance. The diastolic dysfunction improved after the procedure. Most epicardial cysts may be treated in this fashion if the cyst is located in the left side of the heart.


Subject(s)
Coronary Artery Bypass, Off-Pump/methods , Cysts/surgery , Heart Neoplasms/surgery , Adult , Cysts/diagnosis , Heart Neoplasms/diagnosis , Humans , Male , Pericardium , Tomography, X-Ray Computed
7.
Ann Thorac Surg ; 111(6): e415-e417, 2021 06.
Article in English | MEDLINE | ID: mdl-33352177

ABSTRACT

We admitted a 76-year-old woman for treatment of an ascending aortic aneurysm with left ventricular outflow tract (LVOT) obstruction and systolic anterior motion (SAM) of the mitral valve. Echocardiography showed an elevated velocity of the LVOT flow with a sigmoid septum. Mild mitral regurgitation was also detected due to SAM. We performed a graft replacement of the ascending aorta, after which the LVOT obstruction and SAM were resolved. We report a case in which the traction of a graft likely released the compression on the aortic root and ventricular septum.


Subject(s)
Ventricular Outflow Obstruction/surgery , Aged , Aorta/surgery , Blood Vessel Prosthesis , Cardiac Surgical Procedures/methods , Female , Humans , Ventricular Outflow Obstruction/complications
8.
J Artif Organs ; 24(2): 293-295, 2021 Jun.
Article in English | MEDLINE | ID: mdl-32959119

ABSTRACT

Hypo-attenuated leaflet thickening (HALT) is gaining attention as a relatively common issue after surgical or transcatheter aortic valve replacement (AVR). However, only a few reports have described HALT in sutureless bioprosthesis, which has emerged as a promising tool with excellent hemodynamics and enhanced implantability. We herein report a 75-year-old woman who underwent quintuple coronary artery bypass grafting and sutureless AVR with a Perceval S bioprosthesis (LivaNova PLC, London, UK). Despite an uneventful perioperative course, her recovery was slow with persistent pleural effusion. Echocardiography revealed an increased transvalvular pressure gradient, and HALT was confirmed by computed tomography. The patient received aggressive anticoagulation therapy with resolution of the HALT and made an uneventful recovery. Current guidelines provide no specific recommendations for peri-procedural antithrombotic therapy for sutureless AVR. However, HALT is not rare after sutureless AVR and can lead to significant clinical consequences. In this case, aggressive anticoagulation therapy with systemic heparinization was effective as HALT treatment following early post-sutureless AVR. Further investigation is required to determine the optimal antithrombotic strategy for sutureless AVR.


Subject(s)
Aortic Valve Stenosis/etiology , Aortic Valve/physiopathology , Bioprosthesis/adverse effects , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis/adverse effects , Aged , Aortic Valve/diagnostic imaging , Aortic Valve/pathology , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/surgery , Echocardiography , Female , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/methods , Hemodynamics/physiology , Humans , Motion , Pleural Effusion/diagnosis , Pleural Effusion/etiology , Pleural Effusion/physiopathology , Sutureless Surgical Procedures/adverse effects , Sutureless Surgical Procedures/instrumentation , Sutureless Surgical Procedures/methods , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
9.
J Cardiol Cases ; 24(4): 186-189, 2021 Oct.
Article in English | MEDLINE | ID: mdl-35059053

ABSTRACT

Optimal timing of open-heart surgery for the treatment of patients with cerebral hemorrhage remains controversial because systemic heparinization may lead to catastrophic bleeding. Several recent reports have shown that patients who undergo open-heart surgery .within a few weeks of cerebral hemorrhage have a much lower risk of exacerbated bleeding than previously considered. Herein, we report a case of left atrial myxoma and large hemorrhagic embolic stroke, which was successfully operated on with no exacerbation of cerebral hemorrhage. Careful assessment of time-course changes in cerebral hemorrhage by neurological imaging and adjustment of anticoagulation can help prevent the exacerbation of postoperative cerebral hemorrhage and neurological deterioration. .

10.
Gen Thorac Cardiovasc Surg ; 69(2): 353-355, 2021 Feb.
Article in English | MEDLINE | ID: mdl-32712755

ABSTRACT

A 78-year-old woman diagnosed with an infected descending aortic aneurysm underwent graft replacement through a left rib-cross thoracotomy. She developed shock suddenly on the postoperative day 3 owing to cardiac tamponade. We performed emergent surgery and identified a small myocardial laceration in the left ventricular obtuse marginal area and a small perforation on the pericardium. One of the claws used to fix the titanium plate in the cross-rib repair caused this complication. This is a cautionary note regarding this type of titanium plate, which is used in many procedures.


Subject(s)
Cardiac Tamponade , Titanium , Aged , Cardiac Tamponade/diagnostic imaging , Cardiac Tamponade/etiology , Cardiac Tamponade/surgery , Female , Humans , Pericardium , Ribs , Thoracotomy
11.
Gen Thorac Cardiovasc Surg ; 69(5): 790-795, 2021 May.
Article in English | MEDLINE | ID: mdl-33113115

ABSTRACT

OBJECTIVE: The aim of this study was to compare outcomes of the full maze procedure with left atrial appendage closure (LAAc) as concomitant procedures for atrial fibrillation (AF) in patients undergoing cardiovascular surgery. METHODS: A total of 151 patients (88 men, 62 women) underwent elective AF surgery concomitantly with cardiovascular surgery from April 2005 to December 2019. The mean age at time of operation was 70 years and the mean follow-up period was 5.2 ± 3.8 years. Patients were divided into two groups according to the procedure performed: the maze group (n = 87) and the LAAc group (n = 63). RESULTS: Patients in the LAAc group were significantly older and had more comorbidities than those in the maze group. The operative mortality rate was significantly higher in the LAAc group. There was no difference in the rate of freedom from cardiac-related death between the groups (p = 0.86). Furthermore, there was no difference in the 5-year rate of freedom from thromboembolic stroke between the maze group and the LAAc group (p = 0.17). However, the 5-year rate of freedom from heart failure was significantly higher in the maze group compared with the LAAc group (100% vs. 86% ± 6%, respectively; p = 0.006). CONCLUSIONS: Patients undergoing the maze procedure had good operative and long-term results, suggesting that this procedure should be performed if indicated. Concomitant LAAc may be effective for preventing thromboembolic stroke in patients with AF if they have no indication for the maze procedure.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Cardiac Surgical Procedures , Stroke , Atrial Appendage/surgery , Atrial Fibrillation/surgery , Cardiac Surgical Procedures/adverse effects , Female , Humans , Male , Maze Procedure , Stroke/etiology , Stroke/prevention & control , Treatment Outcome
12.
J Artif Organs ; 23(4): 401-404, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32508003

ABSTRACT

Sutureless aortic valve replacement (AVR) offers an alternative approach to the standard AVR in aortic valve disease. We herein report a case of an 82-year-old woman with severe aortic insufficiency and a persistent type 1 endoleak following a thoracic endovascular aortic repair, who underwent successful combined aortic arch reconstruction and sutureless AVR. The bioprosthesis, Perceval (LivaNova PLC, London, UK), a self-anchoring, self-expanding, sutureless valve, which can be implanted in selected patients with aortic insufficiency was used. Although the patient was frail and at a high risk of open-heart surgery, she had an uneventful postoperative course. Hence, Perceval may be a useful option for combined aortic arch reconstruction and aortic valve surgery in high-risk elderly patients.


Subject(s)
Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Aged, 80 and over , Aorta, Thoracic/surgery , Bioprosthesis , Female , Humans , Prosthesis Design , Plastic Surgery Procedures , Treatment Outcome
13.
Ann Vasc Surg ; 59: 143-149, 2019 Aug.
Article in English | MEDLINE | ID: mdl-30954589

ABSTRACT

BACKGROUND: Perioperative stroke is a major complication after debranching thoracic endovascular aortic repair (TEVAR), with a reported incidence of 7.0-26.9%. Subsequent functional recovery is difficult in most cases. This study was performed to evaluate the efficacy of mini-cardiopulmonary bypass (mini-CPB) support in debranching TEVAR to prevent perioperative stroke. METHODS: From December 2010 to July 2017, 32 patients with a shaggy aorta or intimal irregularity in the aortic arch identified on preoperative computed tomography underwent debranching TEVAR. Nineteen patients underwent debranching TEVAR without mini-CPB, and 13 patients underwent debranching TEVAR with a mini-CPB support. Mini-CPB support had been used in November 2014 to treat perioperative stroke, which had occurred in 8 (42%) patients at that time. The form of the debranching arch vessels was not changed; bypass from the right axillary artery to the left axillary artery was performed for one debranching, and bypass from the right axillary artery to the left common carotid artery and left axillary artery was performed for two debranchings. After establishment of mini-CPB support through this debranching graft and right femoral vein cannulation, all endovascular manipulations were initiated. The left subclavian artery was occluded with a plug at the end of the procedure. RESULTS: The proximal landing zones of the endoprosthesis were as follows: zone 0 in 9 patients, zone 1 in 5 patients, and zone 2 in 5 patients in the no-CPB era and zone 1 in 3 patients and zone 2 in 10 patients in the CPB era. The mean mini-CPB support period was 51 minutes. Postoperative respiratory support and hospitalization were not prolonged with mini-CPB support. The incidence of perioperative stroke was 42% in the no-CPB era and 8% in the CPB era. No operative mortality was observed in the CPB era, although 5 (26%) patients died in the no-CPB era. The cause of operative mortality in the no-CPB era was perioperative stroke in 4 patients and acute myocardial infarction in 1 patient. No significant difference in the cumulative survival rate was found between patients with and without mini-CPB support. CONCLUSIONS: Our mini-CPB system may have the potential to prevent perioperative stroke during debranching TEVAR for treatment of aortic arch pathologies.


Subject(s)
Aorta, Thoracic/surgery , Aortic Diseases/surgery , Blood Vessel Prosthesis Implantation/methods , Cardiopulmonary Bypass/methods , Endovascular Procedures/methods , Stroke/prevention & control , Aged , Aged, 80 and over , Aorta, Thoracic/diagnostic imaging , Aortic Diseases/diagnostic imaging , Aortic Diseases/mortality , Aortography/methods , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/mortality , Cardiopulmonary Bypass/adverse effects , Cardiopulmonary Bypass/mortality , Computed Tomography Angiography , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Endovascular Procedures/mortality , Female , Humans , Male , Middle Aged , Prosthesis Design , Protective Factors , Risk Factors , Stroke/diagnosis , Stroke/etiology , Stroke/mortality , Time Factors , Treatment Outcome
14.
Ann Vasc Dis ; 12(1): 30-35, 2019 Mar 25.
Article in English | MEDLINE | ID: mdl-30931054

ABSTRACT

Objective: The usefulness of abdominal duplex ultrasound (DUS) for the detection of endoleaks after endovascular aneurysm repair (EVAR) was evaluated. Materials and Methods: Among 286 patients who underwent EVAR between September 2007 and July 2017, 241 patients were followed up using abdominal DUS. Endoleaks were detected in 74 patients (31%), who were divided into enlarged and nonenlarged sac groups. Endoleak velocities and widths were measured using abdominal DUS every 6 months after EVAR and were compared between the 2 groups. Results: The aneurysm diameter in the nonenlarged sac group was 54.4±8.7 mm in the final follow-up. None of the patients in the nonenlarged sac group were subjected to reintervention, whereas all patients in the enlarged sac group were subjected to reintervention. The aneurysm diameter in the enlarged sac group was 62.8±8.8 mm at the time of reintervention, and the maximum endoleak flow velocities and endoleak widths were significantly higher in the enlarged sac group than in the nonenlarged sac group (p<0.05). The cutoff values on receiver operating characteristics curves for endoleak velocity and width were 83.4 cm/s and 4.0 mm, respectively. Conclusion: Follow-ups using abdominal DUS are useful after EVAR. Endoleak velocity and width measurements are important, and reintervention may be needed when these measurements exceed their cutoff values.

15.
ASAIO J ; 65(5): 503-508, 2019 07.
Article in English | MEDLINE | ID: mdl-30394887

ABSTRACT

Blood glucose management is important for cardiovascular surgery using cardiopulmonary bypass. The usefulness of an artificial pancreas apparatus (STG-55) to control blood glucose in patients undergoing cardiopulmonary bypass was investigated. Subjects comprised 44 patients using the artificial pancreas during cardiopulmonary bypass between June 2016 and March 2017; 55 were initially enrolled, but 11 were excluded because of blood removal failure. Patients were divided into a monitoring group in which blood glucose levels were only monitored using the artificial pancreas (11 patients: six people with diabetes and 5 people without diabetes) and a management group with glycemic control by automatic insulin administration using the artificial pancreas (33 patients: people with diabetes and 21 people without diabetes). Mean maximum blood glucose levels and variation ranges significantly differed between the monitoring and management groups (p = 0.02). The variation range significantly differed between people with and without diabetes in the monitoring group (p = 0.008), but not in the management group. The artificial pancreas apparatus continuously and accurately reflected glycemic variations, facilitating strict and favorable control.


Subject(s)
Blood Glucose , Cardiopulmonary Bypass/methods , Insulin/administration & dosage , Pancreas, Artificial , Aged , Female , Humans , Male , Middle Aged , Monitoring, Physiologic/instrumentation
16.
Gen Thorac Cardiovasc Surg ; 65(11): 627-632, 2017 Nov.
Article in English | MEDLINE | ID: mdl-28791582

ABSTRACT

OBJECTIVE: Mitral annular structure and dynamics after mitral ring annuloplasty using transesophageal echocardiography during the operation have been reported. We evaluated mitral annular structure and dynamics of three different rings in the mid-term period postoperatively. METHODS: Thirty-one patients underwent mitral valve repair for degenerative mitral insufficiency. The MEMO 3D ring (semi-flexible), Carpentier-Edwards Physio II ring (semi-rigid), and St. Jude Medical Rigid Saddle Ring (rigid) were implanted in 15, 12, and eight patients, respectively, from September 2009 to February 2015. Electrocardiogram-gated three-dimensional computed tomography was performed in the mid-term period postoperatively. RESULTS: The postoperative antero-posterior rate of reduction in diameter from end-diastole to end-systole was slightly larger in the MEMO3D (0.57 ± 0.69%) than in the Physio II (0.08 ± 0.60%) and Rigid Saddle Ring (0.11 ± 0.59%). There was no significant difference in the commissure-to-commissure rate of reduction in diameter among the groups. The postoperative end-systolic annular height to commissure width ratio was significantly larger in the Physio II (20.4 ± 1.7%) and Rigid Saddle Ring (21.3 ± 1.7%) than in the MEMO3D (10.8 ± 3.1%, both p < 0.0001). The rate of increase in the postoperative annular height to commissure width ratio from end-diastole to end-systole was significantly larger in the MEMO3D (2.1 ± 1.7%) than in the Physio II (0.1 ± 0.4%) and Rigid Saddle Ring (0.1 ± 0.6%). CONCLUSIONS: The Physio II and Rigid Saddle Ring can restore the physiological and three-dimensional annular shape, and the MEMO3D can preserve physiological annular dynamics in mid-term period postoperatively.


Subject(s)
Blood Flow Velocity/physiology , Cardiac Valve Annuloplasty/methods , Mitral Valve Insufficiency/surgery , Mitral Valve/surgery , Aged , Diastole , Echocardiography, Transesophageal , Female , Follow-Up Studies , Humans , Imaging, Three-Dimensional , Male , Middle Aged , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Mitral Valve Insufficiency/diagnosis , Mitral Valve Insufficiency/physiopathology , Systole , Time Factors , Tomography, X-Ray Computed
17.
Gen Thorac Cardiovasc Surg ; 65(5): 285-288, 2017 May.
Article in English | MEDLINE | ID: mdl-26984288

ABSTRACT

We report a rare case of a giant right coronary artery aneurysm 13 years after coronary artery bypass grafting. Coronary angiography at the time of primary surgery demonstrated irregular aneurysmal dilatation in the mid-right coronary artery that expanded greatly over a 13-year period to a maximum diameter of 80 mm. The patient underwent aneurysmectomy and interposition using a saphenous vein graft through a right lateral thoracotomy. The patient did not undergo dissection or clamping of the left internal thoracic artery graft, and myocardial protection was obtained using systemic hypothermia and hyperkalaemia in addition to continuous antegrade cardioplegia. Postoperatively, coronary computed tomography showed a lack of residual aneurysm and good flow in the saphenous vein graft. The patient made an uneventful recovery.


Subject(s)
Blood Vessel Prosthesis Implantation/methods , Coronary Aneurysm/surgery , Coronary Vessels/surgery , Mammary Arteries/transplantation , Aged , Coronary Aneurysm/diagnosis , Coronary Angiography , Coronary Vessels/diagnostic imaging , Humans , Male , Postoperative Period , Tomography, X-Ray Computed
18.
Gan To Kagaku Ryoho ; 41(12): 1654-6, 2014 Nov.
Article in Japanese | MEDLINE | ID: mdl-25731285

ABSTRACT

We describe the case of a patient with sigmoid colon cancer liver metastasis accompanied by multiple liver abscesses. The 59-year-old female patient presented with a fever at a body temperature of 39.0°C. On abdominal computed tomography (CT), multiple liver abscesses were detected, and percutaneous transhepatic abscess drainage (PTAD) was performed. The day after the PTAD, the patient's fever subsided and her inflammatory response abated. A lower gastrointestinal examination, performed to identify the origin of her symptoms, revealed a type 1 tumor in the sigmoid colon. A biopsy indicated a moderately differentiated adenocarcinoma. Prior to surgery, a second abdominal CT scan was performed, and a single liver metastasis was detected. Laparoscopic sigmoidectomy and partial liver resection were simultaneously performed. The histopathological diagnosis of the colon cancer was tub2, pN1, pH1, P0, ly1, v1, stage IV. To date, the patient remains free from hepatic abscess and colon cancer recurrence. Gastrointestinal examinations should be performed as early as possible to identify the cause of hepatic abscesses. Moreover, therapeutic decisions should only be made after imaging and examinations have been performed, which will be sufficient to identify the presence of liver metastases.


Subject(s)
Adenocarcinoma/secondary , Liver Abscess/etiology , Liver Neoplasms/secondary , Sigmoid Neoplasms/pathology , Adenocarcinoma/surgery , Female , Humans , Liver Abscess/therapy , Liver Neoplasms/surgery , Magnetic Resonance Imaging , Middle Aged , Multimodal Imaging , Sigmoid Neoplasms/surgery , Tomography, X-Ray Computed
19.
Gan To Kagaku Ryoho ; 41(12): 2047-9, 2014 Nov.
Article in Japanese | MEDLINE | ID: mdl-25731418

ABSTRACT

We report a case of advanced lung cancer with recurrence of liver and tracheal metastases that were responsive to multimodality therapy. The patient was a 77-year-old man who suffered from advanced lung cancer with chronic obstructive pulmonary disease (COPD) and alcohol-induced liver cirrhosis. The primary lung cancer was surgically resected. Eight months after resection of the primary lung cancer, a solitary liver tumor appeared and hepatic resection was performed. Histological findings showed that both the primary lung tumor and the solitary liver tumor were squamous cell carcinoma (SCC). Subsequently, he developed a recurrence in his trachea 8 months after hepatic resection. Radiotherapy, endobronchial argon plasma coagulation (APC), and systemic chemotherapy were administered. The tracheal tumor remained stable without any liver metastasis for 25 months.


Subject(s)
Carcinoma, Squamous Cell/therapy , Liver Neoplasms/therapy , Lung Neoplasms/therapy , Tracheal Neoplasms/therapy , Aged , Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Carcinoma, Squamous Cell/secondary , Combined Modality Therapy , Humans , Liver Cirrhosis, Alcoholic/complications , Liver Neoplasms/secondary , Lung Neoplasms/pathology , Lung Neoplasms/surgery , Male , Pulmonary Disease, Chronic Obstructive/complications , Recurrence , Tracheal Neoplasms/secondary , Treatment Outcome
20.
Gan To Kagaku Ryoho ; 41(12): 2320-1, 2014 Nov.
Article in Japanese | MEDLINE | ID: mdl-25731509

ABSTRACT

In June 2010, a 67-year-old man presented with advanced gastric cancer. He underwent 2 courses of combination chemo- therapy with S-1/CDDP. After chemotherapy, total gastrectomy was performed (pT4aN3aM0, Stage IIIC). Although he underwent S-1 chemotherapy, colon tumors recurred 22 months after the operation. Colonoscopy revealed the presence of type 2 advanced cancer in the ascending colon, and type IIa early cancer in the transverse colon, which were diagnosed as either primary colon cancers or recurrent gastric cancers upon pathological examination. In October 2012, resection of the right side of the colon was performed in order to prevent malignant bowel obstruction. Pathological examination of the resected specimen identified recurrent gastric cancers. After the surgery, he is currently undergoing S-1 chemotherapy and has no sign of recurrent tumors.


Subject(s)
Colonic Neoplasms/surgery , Intestinal Obstruction/surgery , Stomach Neoplasms/pathology , Aged , Antimetabolites, Antineoplastic/therapeutic use , Chemotherapy, Adjuvant , Colonic Neoplasms/drug therapy , Colonic Neoplasms/secondary , Drug Combinations , Gastrectomy , Humans , Intestinal Obstruction/etiology , Male , Oxonic Acid/therapeutic use , Recurrence , Stomach Neoplasms/drug therapy , Stomach Neoplasms/surgery , Tegafur/therapeutic use
SELECTION OF CITATIONS
SEARCH DETAIL
...