Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Rev Sci Instrum ; 93(8): 081101, 2022 Aug 01.
Article in English | MEDLINE | ID: mdl-36050050

ABSTRACT

Giant negative ion sources for neutral beam injectors deliver huge negative ion currents, thanks to their multi-beamlet configuration. As the single-beamlet optics defines the transmission losses along the beamline, the extraction of a similar current for all beamlets is extremely desirable, in order to facilitate the beam source operation (i.e., around perveance match). This Review investigates the correlation between the vertical profile of beam intensity and the vertical profiles of plasma properties at the extraction region of the source, focusing on the influence of increasing cesium injection. Only by the combined use of all available source diagnostics, described in this Review, can beam features on the scale of the non-uniformities be investigated with a sufficient space resolution. At RF power of 50 kW/driver, with intermediate bias currents and a filter field of 2.4 mT, it is found that the central part of the four vertical beam segments exhibits comparable plasma density and beamlet currents; at the edges of the central segments, both the beam and electron density appear to decrease (probably maintaining fixed electron-to-ion ratio); at the bottom of the source, an increase of cesium injection can compensate for the vertical drifts that cause a much higher presence of electrons and a lower amount of negative ions.

2.
Rev Sci Instrum ; 92(4): 043302, 2021 Apr 01.
Article in English | MEDLINE | ID: mdl-34243389

ABSTRACT

Beam tomography is a non-invasive diagnostic that allows us to reconstruct the beam emission profile by measuring the light emitted by the beam particles interacting with the background gas, along an elevated number of lines of sight, which is related to the beam density by assuming a uniform background gas. In the framework of the heating and current drive of future nuclear fusion reactors, negative ion beams of hydrogen and deuterium are required for neutral beam injectors (NBIs) due to their elevated neutralization efficiency at high energy (in the MeV range). Beside the beam energy, beam divergence and homogeneity are two critical aspects in the design of future NBIs. In this paper, the characterization of the negative ion beam of the negative ion source NIO1 (a small-sized radio-frequency driven negative ion source, with 130 mA of total extracted H- current and 60 kV of maximum acceleration) using the tomographic system composed of two visible cameras is presented. The Simultaneous Algebraic Reconstruction Technique (SART) is used as an inversion technique to reconstruct the 3 × 3 matrix of the extracted beamlets, and the beam divergence and homogeneity are studied. The results are compared with the measurements of the other diagnostics and correlated with the source physics. The suitability of visible cameras as a diagnostics system for the characterization of the NIO1 negative ion beam is a small-scale experimental demonstration of the possibility to reconstruct more complicated multi-beamlet profiles, resulting in a powerful diagnostic for large NBIs.

3.
Rev Sci Instrum ; 91(1): 013316, 2020 Jan 01.
Article in English | MEDLINE | ID: mdl-32012575

ABSTRACT

The NIO1 (Negative Ion Optimization phase 1) source can provide continuous beam operation, which is convenient for systematic parameter and equipment studies. Even in the pure volume production regime, the source yield was found to depend on conditioning procedures. Magnetic configuration tests continued adding magnets to the existing setup; the filter field component Bx has been progressively extended to span the -12 to 5 mT range, and as a trend, source performances improved with |Bx|. The progress of camera beam diagnostics and of the quality of the volume-produced H- beam is also shown. The status, off-line results, and reliability of a first NIO1 cesium oven are discussed; other upgrades in preparation (cavity ring down spectrometer, the end calorimeter, and conceptual tests of the energy recovery system) are also listed.

4.
Rev Sci Instrum ; 91(1): 013509, 2020 Jan 01.
Article in English | MEDLINE | ID: mdl-32012577

ABSTRACT

For the ITER fusion experiment, two neutral beam injectors are required for plasma heating and current drive. Each injector supplies a power of about 17 MW, obtained from neutralization of 40 A (46 A), 1 MeV (0.87 MeV) negative deuterium (hydrogen) ions. The full beam is composed of 1280 beamlets, formed in 16 beamlet groups, and strict requirements apply to the beamlet core divergence (<7 mrad). The test facility BATMAN Upgrade uses an ITER-like grid with one beamlet group, which consists of 70 apertures. In a joint campaign performed by IPP and Consorzio RFX to better assess the beam optics, the divergence of a single beamlet was compared to a group of beamlets at BATMAN Upgrade. The single beamlet is measured with a carbon fiber composite tile calorimeter and by beam emission spectroscopy, whereas the divergence of the group of beamlets is measured by beam emission spectroscopy only. When increasing the RF power at low extraction voltages, the divergence of the beamlet and of the group of beamlets is continuously decreasing and no inflection point toward an overperveant beam is found. At the same time, scraping of the extracted ion beam at the second grid (extraction grid) takes place at higher RF power, supported by the absence of the normally seen linear behavior between the measured negative ion density in the plasma close to the extraction system and the measured extracted ion current. Beside its influence on the divergence, beamlet scraping needs to be considered for the determination of the correct perveance and contributes to the measured coextracted electron current.

SELECTION OF CITATIONS
SEARCH DETAIL
...