Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Mol Sci ; 22(24)2021 Dec 14.
Article in English | MEDLINE | ID: mdl-34948238

ABSTRACT

The increasing incidence of trauma in medicine brings with it new demands on the materials used for the surgical treatment of bone fractures. Titanium, its alloys, and steel are used worldwide in the treatment of skeletal injuries. These metallic materials, although inert, are often removed after the injured bone has healed. The second-stage procedure-the removal of the plates and screws-can overwhelm patients and overload healthcare systems. The development of suitable absorbable metallic materials would help us to overcome these issues. In this experimental study, we analyzed an extruded Zn-0.8Mg-0.2Sr (wt.%) alloy on a rabbit model. From this alloy we developed screws which were implanted into the rabbit tibia. After 120, 240, and 360 days, we tested the toxicity at the site of implantation and also within the vital organs: the liver, kidneys, and brain. The results were compared with a control group, implanted with a Ti-based screw and sacrificed after 360 days. The samples were analyzed using X-ray, micro-CT, and a scanning electron microscope. Chemical analysis revealed only small concentrations of zinc, strontium, and magnesium in the liver, kidneys, and brain. Histologically, the alloy was verified to possess very good biocompatibility after 360 days, without any signs of toxicity at the site of implantation. We did not observe raised levels of Sr, Zn, or Mg in any of the vital organs when compared with the Ti group at 360 days. The material was found to slowly degrade in vivo, forming solid corrosion products on its surface.


Subject(s)
Absorbable Implants , Alloys , Materials Testing , Tibia/metabolism , Tibial Fractures , Alloys/chemistry , Alloys/pharmacokinetics , Alloys/pharmacology , Animals , Humans , Magnesium/chemistry , Magnesium/pharmacokinetics , Magnesium/pharmacology , Rabbits , Strontium/chemistry , Strontium/pharmacokinetics , Strontium/pharmacology , Tibia/pathology , Tibial Fractures/metabolism , Tibial Fractures/surgery , Zinc/chemistry , Zinc/pharmacokinetics , Zinc/pharmacology
2.
Materials (Basel) ; 14(12)2021 Jun 13.
Article in English | MEDLINE | ID: mdl-34199249

ABSTRACT

In this pilot study, we investigated the biocompatibility and degradation rate of an extruded Zn-0.8Mg-0.2Sr (wt.%) alloy on a rabbit model. An alloy screw was implanted into one of the tibiae of New Zealand White rabbits. After 120 days, the animals were euthanized. Evaluation included clinical assessment, microCT, histological examination of implants, analyses of the adjacent bone, and assessment of zinc, magnesium, and strontium in vital organs (liver, kidneys, brain). The bone sections with the implanted screw were examined via scanning electron microscopy and energy dispersive spectroscopy (SEM-EDS). This method showed that the implant was covered by a thin layer of phosphate-based solid corrosion products with a thickness ranging between 4 and 5 µm. Only negligible changes of the implant volume and area were observed. The degradation was not connected with gas evolution. The screws were fibrointegrated, partially osseointegrated histologically. We observed no inflammatory reaction or bone resorption. Periosteal apposition and formation of new bone with a regular structure were frequently observed near the implant surface. The histological evaluation of the liver, kidneys, and brain showed no toxic changes. The levels of Zn, Mg, and Sr after 120 days in the liver, kidneys, and brain did not exceed the reference values for these elements. The alloy was safe, biocompatible, and well-tolerated.

3.
J Biomater Appl ; 32(7): 886-895, 2018 02.
Article in English | MEDLINE | ID: mdl-29192548

ABSTRACT

Introduction A standard osteosynthetic material for maxillofacial skeleton is titanium and its alloys. The convenience of degradable material is avoiding of second surgery in cases, where removal of the material is necessary. Magnesium biodegradable alloys have similar mechanic properties as cortical bone - reasonable corrosion and sufficient biologic properties. They might be used in facial skeleton fixation. Materials and methods The study included a total of 16 rabbits, and they were randomly divided into two groups. Each group received two screws (WE4 and titanium as a standard material) in artificially drilled defect into right tibia. Animals were euthanized at four-week intervals. Bone samples with implants underwent microfocus CT scans and were histologically examined. Results WE43 alloys showed fragmentation of the material on the 16th week - statistically significant volume loss was found between weeks 12 and 16. Bone healing around the WE43 screws was of similar quality as around titanium screws, and no adverse effect was noticed. Conclusion The study showed good quality of bone healing around WE43 implants. From this point of view, the WE43 alloy meets the requirements of osteosynthetic material for maxillofacial skeleton.


Subject(s)
Absorbable Implants , Alloys/chemistry , Bone Screws , Magnesium/chemistry , Tibia/injuries , Tibia/surgery , Titanium/chemistry , Absorbable Implants/adverse effects , Alloys/adverse effects , Animals , Bone Screws/adverse effects , Magnesium/adverse effects , Male , Rabbits , Surface Properties , Tibia/pathology , Titanium/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL
...