Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 30
Filter
1.
Int J Cardiol Heart Vasc ; 50: 101326, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38192687

ABSTRACT

Background: The POLARx FIT system (Boston Scientific, MA, USA) is a novel cryoballoon (CB) ablation technology in which the balloon diameter can be expanded from 28 to 31 mm. The aim of this study was to compare the benefits and safety of the new POLARx FIT system to those of the existing POLARx system currently in use for pulmonary vein (PV) isolation (PVI) in patients with atrial fibrillation. Methods: The first 70 consecutive patients who underwent CB-based PVI with the POLARx FIT system were retrospectively compared with 200 consecutive patients treated with the POLARx system at Sakakibara Heart Institute from October 2021 to May 2023. Results: The POLARx FIT system yielded a higher mean ± standard deviation nadir temperature in the right inferior PV (-59.2 ± 5.29 °C vs. - 62.0 ± 5.08 °C, p = 0.006), but this required a balloon size reduction to 28 mm in 30 % of cases. No significant differences were detected in the time to isolation and thaw time of any PV between the two groups. After the CB-based PVI procedure, no residual PV carina potentials were observed with the POLARx FIT system, whereas 4/20 were with the POLARx system (p = 0.04). Conclusions: The POLARx FIT system had comparable effectiveness and safety to the basic POLARx system. This technology may improve the ablation area, including the PV carina. However, the 31-mm balloon alone was not sufficient to isolate certain PVs.

2.
Am J Cardiol ; 178: 52-59, 2022 09 01.
Article in English | MEDLINE | ID: mdl-35817597

ABSTRACT

The basis for selection of contemporary ablation technologies for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF) remains unclear. We compared procedural data and efficacy in a propensity score-matched cohort treated with 4 ablation technologies in a center mainly using cryoballoon (CB). A total of 819 consecutive patients with AF underwent PVI, using radiofrequency current (RFC) (65 patients), CB (693 patients), hot balloon (HB) (74 patients), and laser balloon (LB) (52 patients). Fifty patients (82% paroxysmal AF) were selected from each group according to the propensity score. Procedural data and freedom from atrial tachyarrhythmia recurrence after the index procedure were compared. All pulmonary veins were isolated in all groups. Procedure time was shorter in CB and HB groups (RFC: 148 ± 53 vs CB: 85 ± 37 vs HB: 102 ± 31 vs LB: 140 ± 28 minutes, p <0.001). RFC touch-up was most commonly required for PVI in the HB group among balloon groups (40%) (p <0.001). Total complication rate was 4% to 18% without any statistical differences between groups (p = 0.123). Phrenic nerve injury occurred most often in the CB group (16%) (p <0.001). During a mean follow-up of 21 ± 6 months, there were no significant differences among groups for freedom from atrial tachyarrhythmia recurrence after the index procedure (RFC: 68% vs CB: 78% vs HB: 76% vs LB: 76%, p = 0.440). In conclusion, all the ablation technologies facilitate safe and efficient PVI, with slight differences in the procedural data and complications.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Catheter Ablation/methods , Cryosurgery/methods , Humans , Pulmonary Veins/surgery , Recurrence , Treatment Outcome
3.
Heart Rhythm O2 ; 3(3): 311-318, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35734297

ABSTRACT

Background: The lesion formation properties of a motorized rotational delivery (RAPID) mode, third-generation laser balloon (LB3) ablation compared to point-by-point laser ablation in patients with atrial fibrillation remain unclear. Objective: The purpose of this study was to assess lesion characteristics and thermodynamics in LB3 ablation with a RAPID mode in vitro model. Methods: Chicken muscles were cauterized using LB3 in RAPID mode with 13 W and 15 W and 50% overlapped point-by-point fashion with 7 W/30 seconds, 8.5 W/20 seconds, 10 W/20 seconds, and 12 W/20 seconds. Lesion depth, width, and continuity were compared. Lesion continuity was classified by the visible gap degree categorized from 1 (perfect) to 3 (poor). Thermodynamics and maximum tissue temperatures were assessed under infrared thermographic monitoring. Fifteen and 5 lesions were evaluated per ablation protocol for measurement of lesion size and continuity and for thermographic assessment, respectively. Results: Lesion depth and width were smaller in RAPID mode laser ablation than point-by-point laser ablation (P <.001). However, RAPID mode laser ablation revealed sufficient mean lesion depth of 5 mm or more. Lesion continuity was 1 (perfect) in all samples in RAPID mode laser ablation and point-by-point laser ablation (P = 1). Infrared thermographic observation demonstrated fast and gapless linear lesion formation with thermal stacking in RAPID mode laser ablation. Maximum tissue temperature was lower in RAPID mode laser ablation than point-by-point laser ablation (P <.001). Conclusion: RAPID mode LB3 ablation could provide fast, gapless, and acceptable lesion formation with thermal stacking and moderate tissue temperature rise.

4.
Int J Cardiol Heart Vasc ; 39: 100967, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35146121

ABSTRACT

BACKGROUND: A surface temperature sensor can be used to visualize the effect of hot balloon (HB) catheters. This study evaluated the efficacy and safety of a second-generation HB system with surface temperature monitoring in patients with atrial fibrillation (AF). METHODS: Twenty patients (age: 69.6 ± 9.7 years, 11 male participants) who underwent first-time pulmonary vein isolation (PVI) using a second-generation HB were included. For each pulmonary vein (PV), the acute isolation rate and effective therapeutic range of surface temperature were investigated. RESULTS: Eighty-three PVs (including three right middle PVs) were isolated in 20 patients using an HB with a surface temperature sensor. Sixty-eight PVs were isolated using the first application. Fifteen PVs (left superior PV [LSPV], n = 7 [35%]; left inferior PV, n = 2 [10%]; right superior PV, n = 3 [15%]; right inferior PV, n = 3 [15%]) showed early intraoperative reconduction and required second applications. One LSPV required radiofrequency touch-up at the carina. The optimal balloon surface temperature and application time were evaluated, and a median value of 58 °C and integral value of 1000 °C·s were identified from the receiver operating characteristic curve to be useful effective indicators. However, for LSPV, the PV potential of carina or ridge likely often remained and needed to be independently considered. There was no periprocedural complication including severe pulmonary vein stenosis. During the observation period (median: 280 days, interquartile range: 261-318 days), 17 patients (85%) achieved and maintained sinus rhythm. CONCLUSIONS: Second-generation HBs with a surface temperature sensor are expected to provide favorable outcomes in AF ablation treatment.

5.
Int Heart J ; 62(1): 135-141, 2021.
Article in English | MEDLINE | ID: mdl-33518652

ABSTRACT

Although it is well known that patients with hypertrophic cardiomyopathy (HCM) have serious adverse events, such as life-threatening arrhythmia and heart failure, the prediction of such evens is still difficult. Recently, it has been reported that one of the causes of these serious adverse events is microvascular dysfunction, which can be noninvasively evaluated by employing cardiac magnetic resonance (CMR) imaging.We analyzed 32 consecutive HCM patients via CMR imaging and myocardial scintigraphy and divided them into two groups: ventricular tachycardia (VT) group and non-VT group. Myocardial perfusion studies were conducted quantitatively using the QMass® software, and each slice image was divided into six segments. The time-intensity curve derived from the perfusion image by CMR imaging was evaluated, and the time to 50% of the peak intensity (time 50% max) was automatically calculated for each segment.Although no difference was observed in various parameters of myocardial scintigraphy between the two groups, the VT group exhibited a higher mean of time 50% max and wider standard deviation (SD) of time 50% max in each segment than the non-VT group. The cutoff values were obtained by the receiver operating characteristic curves derived from the mean of time 50% max and SD of time 50% max. The two groups divided by the cutoff values exhibited significant differences in the occurrence of serious adverse events.CMR imaging may be useful for predicting serious adverse events of patients with HCM.


Subject(s)
Cardiomyopathy, Hypertrophic/diagnostic imaging , Magnetic Resonance Imaging , Myocardial Perfusion Imaging , Tachycardia, Ventricular/diagnostic imaging , Adult , Aged , Cardiomyopathy, Hypertrophic/complications , Female , Humans , Male , Middle Aged , Retrospective Studies , Tachycardia, Ventricular/etiology
6.
Can J Infect Dis Med Microbiol ; 2017: 4896791, 2017.
Article in English | MEDLINE | ID: mdl-28316631

ABSTRACT

Background. Early detection of Gram-positive bacteremia and timely appropriate antimicrobial therapy are required for decreasing patient mortality. The purpose of our study was to evaluate the performance of the Verigene Gram-positive blood culture assay (BC-GP) in two special healthcare settings and determine the potential impact of rapid blood culture testing for Gram-positive bacteremia within the Japanese healthcare delivery system. Furthermore, the study included simulated blood cultures, which included a library of well-characterized methicillin-resistant Staphylococcus aureus (MRSA) and vancomycin-resistant enterococci (VRE) isolates reflecting different geographical regions in Japan. Methods. A total 347 BC-GP assays were performed on clinical and simulated blood cultures. BC-GP results were compared to results obtained by reference methods for genus/species identification and detection of resistance genes using molecular and MALDI-TOF MS methodologies. Results. For identification and detection of resistance genes at two clinical sites and simulated blood cultures, overall concordance of BC-GP with reference methods was 327/347 (94%). The time for identification and antimicrobial resistance detection by BC-GP was significantly shorter compared to routine testing especially at the cardiology hospital, which does not offer clinical microbiology services on weekends and holidays. Conclusion. BC-GP generated accurate identification and detection of resistance markers compared with routine laboratory methods for Gram-positive organisms in specialized clinical settings providing more rapid results than current routine testing.

7.
Int J Cardiol ; 227: 222-224, 2017 Jan 15.
Article in English | MEDLINE | ID: mdl-27839820

ABSTRACT

BACKGROUND: Early cardiac surgery may have a trade-off between stabilized hemodynamics with controlled infection and a risk of peri-operative death in patients with infective endocarditis (IE) complicated with cardio-embolic strokes. METHODS: We retrospectively studied clinical characteristics and outcomes in 68 consecutive patients with IE (mean age, 58±3years, 62% male) who admitted in our institute during June 2013 and August 2015. RESULTS: Cardio-embolic strokes were noted in 37% of patients (n=25) with IE and overall in-hospital mortality was 4 times higher in IE with cardio-embolic strokes than IE with an absence of strokes (n=43) (20% vs. 4.7%, p=0.045). Bacteremia of Staphylococcus aureus (p=0.021) and a complication of cardio-embolic strokes (p=0.031) were independently associated with in-hospital death in those with IE. However, in-hospital mortality was quite low in 19 with early cardiac surgery compared with 6 with conventional treatment in those with cardio-embolic strokes (11% vs. 50%, p=0.035). Multivariate logistic analysis demonstrated that lack of early cardiac surgery (p=0.014), a complication of cerebral hemorrhage (p=0.002), and a presence of refractory heart failure (p=0.047) were independently associated with in-hospital death in those with IE complicated with cardio-embolic strokes. CONCLUSION: Early cardiac surgery may provide clinical advantages overcoming peri-operative risks in those with IE complicated with cardio-embolic strokes.


Subject(s)
Cardiac Surgical Procedures/adverse effects , Endocarditis, Bacterial/mortality , Endocarditis, Bacterial/surgery , Intracranial Embolism/etiology , Staphylococcal Infections/mortality , Stroke/etiology , Aged , Cardiac Surgical Procedures/methods , Cohort Studies , Endocarditis, Bacterial/diagnosis , Female , Hospital Mortality , Hospitalization/statistics & numerical data , Humans , Intracranial Embolism/mortality , Intracranial Embolism/physiopathology , Kaplan-Meier Estimate , Logistic Models , Male , Middle Aged , Postoperative Complications/mortality , Postoperative Complications/physiopathology , Retrospective Studies , Risk Assessment , Staphylococcal Infections/diagnosis , Staphylococcal Infections/surgery , Statistics, Nonparametric , Stroke/mortality , Stroke/physiopathology , Survival Analysis , Time Factors
8.
Heart Vessels ; 31(1): 38-45, 2016 Jan.
Article in English | MEDLINE | ID: mdl-25217037

ABSTRACT

Simultaneous dual-isotope SPECT imaging with 201Tl and (123)I-ß-methyl-p-iodophenylpentadecanoic acid (BMIPP) is used to study the perfusion-metabolism mismatch. It predicts post-ischemic functional recovery by detecting stunned myocardium. On the other hand, (99m)Tc-MIBI is another radioisotope widely used in myocardial perfusion imaging because of its better image quality and lower radiation exposure than 201Tl. However, since the photopeak energies of (99m)Tc and (123)I are very similar, crosstalk hampers the simultaneous use of these two radioisotopes. To overcome this problem, we conducted simultaneous dual-isotope imaging study using the D-SPECT scanner (Spectrum-Dynamics, Israel) which has a novel detector design and excellent energy resolution. We first conducted a basic experiment using cardiac phantom to simulate the condition of normal perfusion and impaired fatty acid metabolism. Subsequently, we prospectively recruited 30 consecutive patients who underwent successful percutaneous coronary intervention for acute myocardial infarction, and performed (99m)Tc-MIBI/(123)I-BMIPP dual-isotope imaging within 5 days after reperfusion. Images were interpreted by two experienced cardiovascular radiologists to identify the infarcted and stunned areas based on the coronary artery territories. As a result, cardiac phantom experiment revealed no significant crosstalk between (99m)Tc and (123)I. In the subsequent clinical study, (99m)Tc-MIBI/(123)I-BMIPP dual-isotope imaging in all participant yielded excellent image quality and detected infarcted and stunned areas correctly when compared with coronary angiographic findings. Furthermore, we were able to reduce radiation exposure to significantly approximately one-eighth. In conclusion, we successfully demonstrated the practical application of simultaneous assessment of myocardial perfusion and fatty acid metabolism by (99m)Tc-MIBI and (123)I-BMIPP using a D-SPECT cardiac scanner. Compared with conventional (201)TlCl/(123)I-BMIPP dual-isotope imaging, the use of (99m)Tc-MIBI instead of (201)TlCl improves image quality as well as lowers radiation exposure.


Subject(s)
Fatty Acids/metabolism , Myocardial Infarction/diagnostic imaging , Myocardial Perfusion Imaging/methods , Radiopharmaceuticals/administration & dosage , Tomography, Emission-Computed, Single-Photon , Adult , Aged , Aged, 80 and over , Coronary Angiography/methods , Feasibility Studies , Female , Heart/physiopathology , Humans , Iofetamine/administration & dosage , Japan , Male , Middle Aged , Myocardial Infarction/surgery , Percutaneous Coronary Intervention/methods , Phantoms, Imaging , Technetium Tc 99m Sestamibi/administration & dosage
10.
Int J Cardiol ; 176(3): 969-74, 2014 Oct 20.
Article in English | MEDLINE | ID: mdl-25205480

ABSTRACT

BACKGROUND/OBJECTIVES: Detecting the presence of coronary artery disease (CAD) is critically important in managing patients with heart failure of uncertain cause. The recently introduced 123I-BMIPP/201TlCl dual myocardial single-photon emission computed tomography (dual SPECT) is potentially a non-invasive diagnostic tool in detecting ischemic heart disease. The aim of our study is to evaluate the efficacy of detecting CAD by dual SPECT in patients with heart failure. METHODS: We studied 501 consecutive patients (366 males, mean age 68±12 years) who were admitted because of heart failure between January 2005 and April 2009. In all patients, the dual SPECT was performed in clinically stabilized states, followed by coronary angiography within 1 week. The polar map of the SPECT image was divided into 17 segments, each scored on a scale of 0-4 based on segmental percent uptake. The mismatch score was defined as the difference between 123I-BMIPP defect score and 201TlCI defect score. The uptake of 201TlCl and 123I-BMIPP was analyzed quantitatively using the Heart Score View software. RESULTS: The 201TlCI defect score and mismatch score were significantly higher in CAD patients than in non-CAD patients. The receiver operating characteristic (ROC) curve revealed that the mismatch score was a significantly more effective marker in detecting the presence of CAD than 201TlCl defect score (area under the curve: 0.84 versus 0.73, p<0.05). Using the mismatch score, the sensitivity and specificity of dual SPECT in detecting CAD were 84% and 83%, respectively. CONCLUSION: Dual SPECT is a useful non-invasive procedure for the detection of CAD in patients with heart failure.


Subject(s)
Coronary Artery Disease/diagnosis , Fatty Acids , Heart Failure/diagnostic imaging , Iodine Radioisotopes , Iodobenzenes , Thallium Radioisotopes , Thallium , Tomography, Emission-Computed, Single-Photon , Adult , Aged , Aged, 80 and over , Coronary Artery Disease/complications , Female , Heart Failure/complications , Humans , Male , Middle Aged , Predictive Value of Tests , Retrospective Studies
11.
J Cardiol Cases ; 9(4): 129-133, 2014 Apr.
Article in English | MEDLINE | ID: mdl-30546782

ABSTRACT

A 78-year-old woman complained of experiencing dyspnea (New York Heart Association II) and faintness. Echocardiography revealed she had asymmetric left ventricular hypertrophy, and a dynamic left ventricular outflow tract (LVOT) obstruction due to systolic anterior motion of the mitral valve. It also revealed calcification of the noncoronary cusp and a high-flow velocity in the LVOT (6.3 m/s). The planimetry measurement with transesophageal echocardiography was 0.89 cm2 (aortic valve area/body surface area: 0.69 cm2/m2). Later, she was diagnosed with hypertrophic obstructive cardiomyopathy (HOCM) and aortic stenosis (AS). However, during the catheterization, the transvalvular pressure gradient (PG) was only 25 mmHg. In order to solve this, we performed a percutaneous transluminal septal myocardial ablation. As a result, the PG of the LVOT decreased from 152 mmHg to 25 mmHg. We first thought that the LVOT obstruction had reduced the flow passing through the aortic valve, and restricted the motion of the aortic valve leaflets. We also considered the possibility that the aortic valve area had been underestimated. The hemodynamic study played an important role in the decision for the treatment plan. The present case was a combination of HOCM and "mild" AS. .

12.
Heart Lung ; 42(5): 379-81, 2013.
Article in English | MEDLINE | ID: mdl-23831301

ABSTRACT

We present a case of prosthetic valve endocarditis, which was caused by a rare etiological agent, Streptococcus constellatus. In our case, transesophageal echocardiography showed a large and broad abscess formation throughout the patient's aortic prosthetic valve ring and left atrium. Despite specific intravenous antibiotic therapy, the infection was uncontrollable, and the patient underwent surgical treatment. The pathogen rarely causes endocarditis, but it is known to have a strong potential to form abscess, and therefore its infection may be more serious than other Streptococcus species. Our case seems to be the first report of surgical treatment of PVE caused by S. constellatus. As in our case, transesophageal echocardiography is useful for the detection of vegetation and abscess, and early cardiac surgery may be a more appropriate therapeutic approach for endocarditis caused by S. constellatus.


Subject(s)
Aortic Valve/diagnostic imaging , Endocarditis, Bacterial/microbiology , Heart Valve Prosthesis/adverse effects , Prosthesis-Related Infections/microbiology , Streptococcal Infections/diagnostic imaging , Streptococcus constellatus , Abscess/diagnostic imaging , Abscess/microbiology , Echocardiography, Transesophageal , Endocarditis, Bacterial/diagnostic imaging , Humans , Male , Middle Aged , Prosthesis-Related Infections/diagnostic imaging
13.
J Cardiol ; 61(4): 281-8, 2013 Apr.
Article in English | MEDLINE | ID: mdl-23466066

ABSTRACT

BACKGROUND: Traditional 3-dimensional echocardiography (3DE) with volumetric scanning technique requires several heart cycles for full-volume acquisition and complicated manual contouring of left ventricular (LV) endocardium. The new real-time 3DE (RT3DE) system allows acquisition of an instantaneous full-volume dataset in a single heart cycle and automated measurement of LV volume by the algorithm software. However, it has not been evaluated adequately whether automated measurement by RT3DE has better agreement with cardiac magnetic resonance imaging (CMR) than 2-dimensional echocardiography (2DE) with CMR. PURPOSE: This study aimed to evaluate the accuracy of automated measurement of LV volume using RT3DE compared with 2DE and CMR. METHODS AND RESULTS: Forty-four consecutive patients who underwent RT3DE, 2DE, and CMR were evaluated in this study. The feasibility of automated measurement by RT3DE was 93.2% and the mean operation time was 6min. LV volume and ejection fraction (EF) from semi-automated measurement [end-diastolic volume: r=0.96, limits of agreement (LOA) -30.5 to 39.3 ml; end-systolic volume: r=0.97, LOA -22.6 to 32.7 ml; EF: r=0.90, LOA -16.1 to 14.2%, respectively] had better agreement with CMR than those from 2DE (r=0.87, LOA -50.5 to 72.2 ml; r=0.93, LOA -34.1 to 65.2 ml; r=0.89, LOA -20.9 to 10.0%, respectively). CONCLUSION: Semi-automated measurement by RT3DE has better agreement with CMR than 2DE in LV volume and EF. In addition, it is simple to operate and acceptable in feasibility for the clinical setting although there may be room for further learning required to incorporate small hypertrophic LV into the automated algorithm software.


Subject(s)
Cardiac Volume , Computer Systems , Echocardiography, Three-Dimensional/methods , Echocardiography , Heart Diseases/diagnostic imaging , Heart Diseases/physiopathology , Heart Ventricles/physiopathology , Heart Ventricles/ultrastructure , Magnetic Resonance Imaging , Ventricular Function, Left , Aged , Algorithms , Feasibility Studies , Female , Heart Ventricles/pathology , Humans , Male , Middle Aged , Sensitivity and Specificity , Software
14.
J Echocardiogr ; 11(2): 50-8, 2013 Jun.
Article in English | MEDLINE | ID: mdl-27278511

ABSTRACT

BACKGROUND: Recently, post-exercise diastolic stunning (PES) has been reported as a new clinical marker of induced ischemia. Velocity vector imaging (VVI) has been developed to visualize regional wall motion abnormalities based on vectors detected by the tissue tracking technique, which has the potential to visualize PES. Thus, the aim of this study was to evaluate the usefulness of PES detection by VVI as an objective marker of ischemia compared to stress thallium-201 (Tl-201) single photon emission computed tomography (SPECT). METHODS: We studied consecutive patients who were scheduled to undergo exercise stress Tl-201 SPECT for the diagnosis of ischemic heart disease. Transthoracic echocardiography was recorded digitally before and 20 min after exercise for Tl-201 SPECT, and the data were used subsequently for VVI analysis. We defined PES regions as those with new abnormal vectors observed during isovolumic relaxation. RESULTS: After excluding 14 patients with old myocardial infarction and/or atrial fibrillation, echocardiograms suitable for VVI analysis were obtained from 62 of 65 patients (feasibility, 95 %; 44 men; mean age, 64 ± 11 years). SPECT revealed induced ischemia in 20 patients, whereas VVI identified PES in 18 patients. VVI detected inducible ischemia with 85 % sensitivity and 98 % specificity compared to SPECT. CONCLUSIONS: VVI detection of PES is a new clinical tool for induced ischemia. Regional diastolic wall motion abnormalities following induced ischemia can be noninvasively detected by VVI.

15.
Circ J ; 76(7): 1761-7, 2012.
Article in English | MEDLINE | ID: mdl-22473457

ABSTRACT

BACKGROUND: Aortic stenosis (AS) is increasingly common in the elderly population. A recent invention of transcatheter aortic valve implantation tends to tilt the risk-benefit balance to favor earlier elective intervention for AS. Hence, decision making for elective intervention in octogenarians gradually becomes important. However, the outcome after elective aortic valve replacement (eAVR) has not been evaluated adequately. This study aimed to identify risk factors after eAVR in octogenarians and investigate their influence on long-term outcome. METHODS AND RESULTS: One hundred and thirty-seven consecutive Japanese octogenarians with AS who underwent eAVR were studied. The mean follow-up period was 35±22 (range, 0-88) months. Long-term overall survival rates after eAVR were 92.0%, 85.2% and 75.5% at 1, 3 and 5 years, respectively. Cox proportional hazards model identified age [hazard ratio (HR) 1.23; 95% confidence interval (CI) 1.07-1.43; P<0.01)] and ejection fraction (EF) <50% (HR 3.38; 95%CI 1.34-8.52; P<0.01) as the risk factors of mortality. Post-eAVR survival rates in octogenarians with an EF ≥50% and <50% were 97.3% and 70.4% at 1 year, 90.1% and 65.3% at 3 years, and 84.3% and 39.2% at 5 years, respectively (P<0.0001). CONCLUSIONS: Octogenarians with preserved LV systolic function before surgery have favorable long-term survival after eAVR. However, an EF <50% influences the mortality in octogenarian patients. Therefore, eAVR should be considered for octogenarians with AS before the progression of LV impairment.


Subject(s)
Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation , Stroke Volume , Ventricular Dysfunction, Left/complications , Ventricular Function, Left , Age Factors , Aged, 80 and over , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Disease Progression , Female , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Hospital Mortality , Humans , Japan , Kaplan-Meier Estimate , Male , Postoperative Complications/etiology , Proportional Hazards Models , Retrospective Studies , Risk Assessment , Risk Factors , Survival Rate , Time Factors , Treatment Outcome , Ultrasonography , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Left/mortality , Ventricular Dysfunction, Left/physiopathology
16.
Pediatr Int ; 54(3): 379-82, 2012 Jun.
Article in English | MEDLINE | ID: mdl-22212537

ABSTRACT

BACKGROUND: The use of implantable cardioverter defibrillator (ICD) therapy for congenital heart disease (CHD) has been increasing, but few studies have reported on the efficacy of ICD therapy in Japanese CHD patients. METHOD: Twelve CHD patients (median age, 35 years) with first ICD implantation were examined. Median follow-up duration was 2.9 years. Demographic information, implant electrical parameters, appropriate and inappropriate discharge data and complications were recorded for all implants from 2003 to 2010. RESULTS: Implant indication was primary prevention in two patients and secondary prevention in 10. Overall four patients received one or more discharges; three patients (25%) with secondary prevention received nine appropriate discharges. Inappropriate discharge attributed to sinus tachycardia occurred in two patients (16.7%). Only one patient experienced the late complication of skin erosion at the generator implantation site. CONCLUSIONS: Patients with CHD experienced significant rates of appropriate discharges and lower complications. But given that the indications of ICD implantation were mostly for secondary prevention, the ratio of appropriate shocks might be lower than in previous studies. In the primary prevention patients, the benefit of ICD was not clear because no appropriate discharges were seen during follow up. Although ICD implantation for CHD is beneficial for preventing sudden cardiac death, careful decision making and a large, long-term prospective study is required for the determination of the efficacy of ICD therapy in Japanese patients with CHD.


Subject(s)
Defibrillators, Implantable , Heart Diseases/congenital , Heart Diseases/therapy , Adolescent , Adult , Aged , Child , Female , Humans , Male , Middle Aged , Retrospective Studies , Treatment Outcome , Young Adult
17.
J Echocardiogr ; 10(1): 21-3, 2012 Mar.
Article in English | MEDLINE | ID: mdl-27277925

ABSTRACT

Pure aortic regurgitation (AR) is caused by primary disease of the aortic leaflet and/or the aortic root. However, there are many patients with AR with unclear etiology and mechanism. The assessment of mechanism is critical to the decision of surgical modality for AR. Echocardiography, particularly a detailed analysis of the aortic leaflets and root by transesophageal echocardiography (TEE), could be an important diagnostic step to assess its mechanism. In this report, we present a case of AR in which the TEE images led to diagnosis of cusp bending of aortic leaflet without specific findings indicating this pathology.

18.
J Cardiol ; 58(3): 266-77, 2011 Nov.
Article in English | MEDLINE | ID: mdl-21824749

ABSTRACT

BACKGROUND: Anticoagulation therapy reduces the risk of thromboembolic events by two-thirds in patients with atrial fibrillation (AF). The prevalence of left atrial thrombus (LAT) in AF patients with anticoagulation therapy has not been fully investigated. PURPOSE: To investigate the prevalence of LAT and its impact on the outcomes in patients with nonvalvular AF after anticoagulation therapy. METHODS: This study consisted of 231 patients with nonvalvular AF who had transthoracic (TTE) and transesophageal echocardiographic (TEE) examinations more than 3 weeks after anticoagulation therapy. The clinical and echocardiographic characteristics were evaluated. RESULTS: LAT was observed in 13 (8.8%) of 148 patients with sub-therapeutic anticoagulation, and in 3 (3.6%) of 83 patients with sufficient anticoagulation. The presence of LAT was associated with higher CHADS(2) score, decreased LA volume changes and the presence of spontaneous echocardiographic contrast (SEC) in patients with sub-therapeutic anticoagulation. Patients with LAT after sufficient anticoagulation were male with permanent AF who had decreased left ventricular systolic and diastolic function and dilated LA on TTE and SEC, and reduced appendage flow velocity on TEE. Patients with LAT had worse cardiovascular outcomes compared with those without LAT (p=0.02). CONCLUSIONS: We demonstrated that LAT was a univariate risk factor associated with worse cardiovascular outcomes, which was observed in 8.8% of patients with sub-therapeutic anticoagulation and 3.6% of patients with sufficient anticoagulation.


Subject(s)
Anticoagulants/therapeutic use , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/drug therapy , Heart Atria , Heart Diseases/diagnostic imaging , Heart Diseases/prevention & control , Thrombosis/diagnostic imaging , Thrombosis/prevention & control , Aged , Atrial Fibrillation/complications , Echocardiography, Transesophageal , Female , Heart Diseases/epidemiology , Heart Diseases/etiology , Humans , Male , Middle Aged , Prevalence , Prognosis , Risk Factors , Thrombosis/epidemiology , Thrombosis/etiology
20.
Int J Cardiol ; 142(3): 224-9, 2010 Jul 23.
Article in English | MEDLINE | ID: mdl-19185371

ABSTRACT

PURPOSE: Delayed enhancement cardiovascular magnetic resonance (DE-CMR) can detect cardiac scarring and has the potential to visualize the progression of myocardial remodeling. We determined whether DE-CMR can predict cardiac events in dilated cardiomyopathy patients. MATERIALS AND METHODS: Transthoracic echocardiography, coronary arteriography, and DE-CMR studies were performed in 60 consecutive dilated cardiomyopathy (DCM) patients. Percent delayed enhancement (%DE) was determined as the ratio of the area showing delayed enhancement to the total myocardial area in three short-axis views. Patients were classified as advanced group (Group A) when %DE was 10% or higher, and as non-advanced group (Group NA) when %DE was less than 10%. The incidence of cardiac events and the clinical history were compared between Group A and Group NA. RESULTS: There were 11 patients in Group A and 49 patients in Group NA. The incidence of cardiac events was significantly higher in Group A (36%; 4/11 patients) than in Group NA (2.0%; 1/49 patients) (log rank, p=0.0001). CONCLUSION: DE-CMR is a useful tool to predict cardiac events in DCM patients.


Subject(s)
Cardiomyopathy, Dilated/diagnosis , Magnetic Resonance Imaging/methods , Ventricular Remodeling , Acute Disease , Aged , Cardiomyopathy, Dilated/epidemiology , Coronary Angiography , Echocardiography , Female , Heart Failure/epidemiology , Humans , Incidence , Kaplan-Meier Estimate , Male , Middle Aged , Predictive Value of Tests
SELECTION OF CITATIONS
SEARCH DETAIL
...