Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
2.
Article in English | MEDLINE | ID: mdl-31842318

ABSTRACT

Objective: N-(2-methoxy) benzyl-phenethylamine (NBOMe) derivatives have a high affinity to the serotonin receptor 2A and emerged as new psychedelic agents. We report the case of a 30-year-old man admitted to the hospital because of acute ischemia of the left arm with clinical symptoms of pallor, pulselessness, paresthesia, and a motoric deficit. The patient had a history of schizophrenia and drug abuse and disclosed during the hospital stay the sublingual intake of a substance bought as 25I-NBOMe the night before the ischemic event. Methods: Routine clinical diagnostics including among others color-coded duplex sonography and computed tomography angiography (CTA) were performed. The remainder of the drugs was analyzed using high performance liquid chromatography. Results: Initial color-coded duplex sonography of the upper left limb showed pathological flow profiles of the axillary, brachial, ulnar, and radial artery with a reduced diameter of the ulnar (0.9 mm) and radial (1.1 mm) artery. In consequence, peripheral vasospasm, distal arterial thrombosis, or arterial embolization was anticipated. As therapeutic measures, the patient immediately received intravenous systemic vasodilators (alprostadil) and therapeutic anticoagulation with low molecular weight heparin. Instant symptom improvement was observed within the first day after therapy initiation. The subsequently performed CTA of the heart and left arm showed no signs of thrombotic material. Treatment was continued for five days and the patient was released thereafter having completely normalized perfusion in his left arm. Outpatient treatment was continued with calcium-channel blockers, as the patient had also displayed arterial hypertension. Drug analysis retrieved a composition of the isomers 25I-NBOMe, 25C-NBOMe, and 25H-NBOMe as well as traces of pentylon. Conclusion: NBOMe ingestion implicates the risk of peripheral vasospasms with severe, limb-threatening ischemia.


Subject(s)
Dimethoxyphenylethylamine/analogs & derivatives , Hallucinogens/adverse effects , Ischemia/chemically induced , Adult , Dimethoxyphenylethylamine/adverse effects , Humans , Male
3.
PLoS One ; 13(10): e0204794, 2018.
Article in English | MEDLINE | ID: mdl-30281614

ABSTRACT

BACKGROUND: Modern CT scanners provide automatic dose adjustment systems, which are promising options for reducing radiation dose in pediatric CT scans. Their impact on patient dose, however, has not been investigated sufficiently thus far. OBJECTIVE: To evaluate automated tube voltage selection (ATVS) in combination with automated tube current modulation (ATCM) in non-contrast pediatric chest CT, with regard to the diagnostic image quality. MATERIALS AND METHODS: There were 160 non-contrast pediatric chest CT scans (8.7±5.4 years) analyzed retrospectively without and with ATVS. Correlations of volume CT Dose Index (CTDIvol) and effective diameter, with and without ATVS, were compared using Fisher's z-transformation. Image quality was assessed by mean signal-difference-to-noise ratios (SDNR) in the aorta and in the left main bronchus using the independent samples t-test. Two pediatric radiologists and a general radiologist rated overall subjective Image quality. Readers' agreement was assessed using weighted kappa coefficients. A p value <0.05 was considered significant. RESULTS: CTDIvol correlation with the effective diameter was r = 0.62 without and r = 0.80 with ATVS (CI: -0.04 to -0.60; p = 0.025). Mean SDNR was 10.88 without and 10.03 with ATVS (p = 0.0089). Readers' agreement improved with ATVS (weighted kappa between pediatric radiologists from 0.1 (0.03-0.16) to 0.27 (0.09-0.45) with ATVS; between general and each pediatric radiologist from 0.1 (0.06-0.14) to 0.12 (0.05-0.20), and from 0.22 (0.11-0.34) to 0.36 (0.24-0.49)). CONCLUSION: ATVS, combined with ATCM, results in a radiation dose reduction for pediatric non-contrast chest CT without a loss of diagnostic image quality and prevents errors in manual tube voltage setting, and thus protecting larger children against an unnecessarily high radiation exposure.


Subject(s)
Thorax/diagnostic imaging , Tomography, X-Ray Computed/methods , Algorithms , Child , Contrast Media/metabolism , Female , Humans , Male , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted/methods , Retrospective Studies , Signal-To-Noise Ratio
4.
Cardiovasc Intervent Radiol ; 41(5): 718-725, 2018 May.
Article in English | MEDLINE | ID: mdl-29218656

ABSTRACT

OBJECTIVES: To compare diagnostic performance and time efficiency between 3D multipath curved planar reformations (mpCPRs) and axial images of CT angiography for the pre-interventional assessment of peripheral arterial disease (PAD), with digital subtraction angiography as the standard of reference. METHODS: Forty patients (10 females, mean age 72 years), referred to CTA prior to endovascular treatment of PAD, were prospectively included and underwent peripheral CT angiography. A semiautomated toolbox was used to render mpCPRs. Twenty-one arterial segments were defined in each leg; for each segment, the presence of stenosis > 70% was assessed on mpCPRs and axial images by two readers, independently, with digital subtraction angiography as gold standard. RESULTS: Both readers reached lower sensitivity (Reader 1: 91 vs. 94%, p = 0.08; Reader 2: 89 vs. 93%, p = 0.03) but significantly higher specificity (Reader 1: 94 vs. 89%, p < 0.01; Reader 2: 96 vs. 95%, p = 0.01) with mpCPRs than with axial images. Reader 1 achieved significantly higher accuracy with mpCPRs (93 vs. 91%, p = 0.02), and Reader 2 had similar overall accuracy in both evaluations (94 vs. 94%, p = 0.96). Both readers read mpCPRs significantly faster than axial images (Reader 1: 5'45″ based on mpCPRs vs. 7'40″ based on axial images; Reader 2: 4'41″ based on mpCPRs vs. 6'57″ based on axial images; p < 0.01). CONCLUSIONS: mpCPRs are a promising 3D reformation technique that facilitates a fast assessment of PAD with high diagnostic accuracy.


Subject(s)
Computed Tomography Angiography/methods , Peripheral Arterial Disease/diagnostic imaging , Adult , Aged , Aged, 80 and over , Female , Humans , Imaging, Three-Dimensional/methods , Male , Middle Aged , Multidetector Computed Tomography , Prospective Studies , Reproducibility of Results , Sensitivity and Specificity , Time
5.
Eur J Radiol ; 93: 149-156, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28668409

ABSTRACT

OBJECTIVES: To investigate radiation exposure, objective image quality, and the diagnostic accuracy of a BMI-adjusted ultra-low-dose CT angiography (CTA) protocol for the assessment of peripheral arterial disease (PAD), with digital subtraction angiography (DSA) as the standard of reference. METHODS: In this prospective, IRB-approved study, 40 PAD patients (30 male, mean age 72 years) underwent CTA on a dual-source CT scanner at 80kV tube voltage. The reference amplitude for tube current modulation was personalized based on the body mass index (BMI) with 120 mAs for [BMI≤25] or 150 mAs for [2570%) was assessed by two readers independently and compared to subsequent DSA. Radiation exposure was assessed with the computed tomography dose index (CTDIvol) and the dosis-length product (DLP). Objective image quality was assessed via contrast- and signal-to-noise ratio (CNR and SNR) measurements. Radiation exposure and image quality were compared between the BMI groups and between the BMI-adjusted ultra-low-dose protocol and the low-dose institutional standard protocol (ISP). RESULTS: The BMI-adjusted ultra-low-dose protocol reached high diagnostic accuracy values of 94% for Reader 1 and 93% for Reader 2. Moreover, in comparison to the ISP, it showed significantly (p<0.001) lower CTDIvol (1.97±0.55mGy vs. 4.18±0.62 mGy) and DLP (256±81mGy x cm vs. 544±83mGy x cm) but similar image quality (p=0.37 for CNR). Furthermore, image quality was similar between BMI groups (p=0.86 for CNR). CONCLUSIONS: A CT protocol that incorporates low kV settings with a personalized (BMI-adjusted) reference amplitude for tube current modulation and iterative reconstruction enables very low radiation exposure CTA, while maintaining good image quality and high diagnostic accuracy in the assessment of PAD.


Subject(s)
Body Mass Index , Computed Tomography Angiography/methods , Peripheral Arterial Disease/diagnostic imaging , Adult , Aged , Aged, 80 and over , Angiography, Digital Subtraction/methods , Angiography, Digital Subtraction/standards , Arteries/diagnostic imaging , Computed Tomography Angiography/standards , Female , Humans , Male , Middle Aged , Prospective Studies , Radiation Dosage , Radiation Exposure , Radiographic Image Interpretation, Computer-Assisted/methods , Signal-To-Noise Ratio
6.
Eur J Radiol ; 90: 73-80, 2017 May.
Article in English | MEDLINE | ID: mdl-28583650

ABSTRACT

PURPOSE: To determine the value of CT perfusion (CTP) for early response assessment after transarterial chemoembolization (TACE) for hepatocellular carcinoma (HCC). MATERIALS AND METHODS: Between April 2013 and April 2015, 41 HCC (16 patients) were included in this study. CT perfusion was performed before and one day after TACE. Blood flow (BF), blood volume (BV), time to start (TTS), arterial liver perfusion (ALP), portal liver perfusion (PVP) and hepatic perfusion index (HPI) were measured. Quantitative perfusion values before and after TACE were compared to the response assessed using mRECIST criteria six weeks after TACE and long-term outcome was assessed. RESULTS: Twenty-one lesions (51%) had complete remission (CR) and five (12%) had partial response (PR) six weeks after TACE. CTP parameters were significantly reduced after TACE in responders (PR, CR, p<0.001) while no difference was observed in non-responders. ALPpost was superior in the prediction of CR compared to BFpost and BVpost (p<0.001) with a sensitivity, specificity, PPV, NPV, and accuracy of 90%, 90%, 91%, 90%, and 91%, respectively. Only 3/21 lesions with CR recurred, with a mean local-recurrence-free survival of 19.6 months. CONCLUSION: CT perfusion detects lesions with complete response one day after TACE, and is a feasible tool for early response assessment.


Subject(s)
Carcinoma, Hepatocellular/diagnostic imaging , Chemoembolization, Therapeutic/methods , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/pathology , Tomography, X-Ray Computed/methods , Blood Volume , Carcinoma, Hepatocellular/pathology , Chemoembolization, Therapeutic/standards , Humans , Neoplasm Recurrence, Local , Perfusion , Sensitivity and Specificity , Treatment Outcome
8.
PLoS One ; 11(3): e0149725, 2016.
Article in English | MEDLINE | ID: mdl-26930490

ABSTRACT

PURPOSE: To define the diagnostic precision of non-specialized readers in the detection of type 2 endoleaks (T2EL) in arterial versus venous phase acquisitions, and to evaluate an approach for radiation dose reduction. METHODS: The pre-discharge and final follow-up multi-slice CT angiographies of 167 patients were retrospectively analyzed. Image data were separated into an arterial and a venous phase reading set. Two radiology residents assessed the reading sets for the presence of a T2EL, feeding vessels, and aneurysm sac size. Findings were compared with a standard of reference established by two experts in interventional radiology. The effective dose was calculated. RESULTS: Overall, experts detected 131 T2ELs, and 331 feeding vessels in 334 examinations. Persistent T2ELs causing aneurysm sac growth > 5 mm were detected in 20 patients. Radiation in arterial and venous phases contributed to a mean of 58.6% and 39.0% of the total effective dose. Findings of reader 1 and 2 showed comparable sensitivities in arterial sets of 80.9 versus 85.5 (p = 0.09), and in venous sets of 73.3 versus 79.4 (p = 0.15), respectively. Reader 1 and 2 achieved a significant higher detection rate of feeding vessels with arterial compared to venous set (p = 0.04, p < 0.01). Both readers correctly identified T2ELs with growing aneurysm sac in all cases, independent of the acquisition phase. CONCLUSION: Arterial acquisitions enable non-specialized readers an accurate detection of T2ELs, and a significant better identification of feeding vessels. Based on our results, it seems reasonable to eliminate venous phase acquisitions.


Subject(s)
Angiography/methods , Arteries/pathology , Endoleak/diagnosis , Tomography, X-Ray Computed/methods , Veins/pathology , Aged , Aged, 80 and over , Angiography/instrumentation , Female , Humans , Male , Middle Aged , Radiation Dosage , Reproducibility of Results , Retrospective Studies , Sensitivity and Specificity , Tomography, X-Ray Computed/instrumentation
9.
PLoS One ; 9(6): e99832, 2014.
Article in English | MEDLINE | ID: mdl-24919195

ABSTRACT

OBJECTIVE: To prospectively evaluate image quality and radiation dose using a low-dose computed tomography angiography protocol and iterative image reconstruction for high-pitch dual-source CT-angiography (DSCTA) of the supraaortic arteries. MATERIAL AND METHODS: DSCTA was performed in 42 patients, using either 120 kVp tube voltage, 120 mAS tube current, 2.4 pitch and filtered back projection, or 100 kVp tube voltage, 100 mAs tube current, 3.2 pitch, and sinogram affirmed iterative reconstruction. Measurements of vessel attenuation, of the contrast-to-noise ratio (CNR) and the signal-to-noise ratio (SNR) were performed to objectively evaluate image quality. Two readers evaluated subjective image quality and image noise, using a four-point scale. Effective dose was used to compare the differences in radiation dose. RESULTS: Low-dose protocol application showed significantly higher vessel opacification (p = 0.013), and non-significantly higher CNR and SNR values. There was no difference in the subjective image quality and image noise reading between the protocols. Effective dose was significantly lower using the low-dose protocol (1.29 ± 0.21 mSv vs. 2.92 ± 0.72 mSv; p < 0.001). CONCLUSION: The combined use of reduced tube voltage, reduced tube current, and iterative reconstruction reduces radiation dose by 55.4% in high-pitch DSCTA of the supraaortic arteries without impairment of image quality.


Subject(s)
Angiography/methods , Arteries/diagnostic imaging , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Prospective Studies , Radiation Dosage , Radionuclide Imaging , Signal-To-Noise Ratio
SELECTION OF CITATIONS
SEARCH DETAIL
...