Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Arch Dermatol Res ; 316(7): 391, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38878217

ABSTRACT

Clinical grading of actinic keratosis (AK) is based on skin surface features, while subclinical alterations are not taken into consideration. Dynamic optical coherence tomography (D-OCT) enables quantification of the skin´s vasculature, potentially helpful to improve the link between clinical and subclinical features. We aimed to compare microvascular characteristics across AK grades using D-OCT with automated vascular analysis. This explorative study examined AK and photodamaged skin (PD) on the face or scalp. AKs were clinically graded according to the Olsen Classification scheme before D-OCT assessment. Using an open-source software tool, the OCT angiographic analyzer (OCTAVA), we quantified vascular network features, including total and mean vessel length, mean vessel diameter, vessel area density (VAD), branchpoint density (BD), and mean tortuosity from enface maximum intensity projection images. Additionally, we performed subregional analyses on selected scans to overcome challenges associated with imaging through hyperkeratosis (each lesion group; n = 18). Our study included 45 patients with a total of 205 AKs; 93 grade I lesions, 65 grade II, 47 grade III and 89 areas with PD skin. We found that all AK grades were more extensively vascularized relative to PD, as shown by greater total vessel length and VAD (p ≤ 0.009). Moreover, AKs displayed a disorganized vascular network, with higher BD in AK I-II (p < 0.001), and mean tortuosity in AK II-III (p ≤ 0.001) than in PD. Vascularization also increased with AK grade, showing significantly greater total vessel length in AK III than AK I (p = 0.029). Microvascular quantification of AK unveiled subclinical, quantitative differences among AK grades I-III and PD skin. D-OCT-based microvascular assessment may serve as a supplement to clinical AK grading, potentially raising perspectives to improve management strategies.


Subject(s)
Keratosis, Actinic , Skin , Tomography, Optical Coherence , Humans , Tomography, Optical Coherence/methods , Keratosis, Actinic/diagnostic imaging , Keratosis, Actinic/pathology , Keratosis, Actinic/diagnosis , Male , Female , Aged , Middle Aged , Skin/diagnostic imaging , Skin/pathology , Skin/blood supply , Severity of Illness Index , Aged, 80 and over , Scalp/pathology , Scalp/diagnostic imaging , Skin Aging/pathology , Face/diagnostic imaging
2.
Sci Rep ; 14(1): 5979, 2024 03 12.
Article in English | MEDLINE | ID: mdl-38472220

ABSTRACT

Quantitative assessment of retinal microvasculature in optical coherence tomography angiography (OCTA) images is important for studying, diagnosing, monitoring, and guiding the treatment of ocular and systemic diseases. However, the OCTA user community lacks universal and transparent image analysis tools that can be applied to images from a range of OCTA instruments and provide reliable and consistent microvascular metrics from diverse datasets. We present a retinal extension to the OCTA Vascular Analyser (OCTAVA) that addresses the challenges of providing robust, easy-to-use, and transparent analysis of retinal OCTA images. OCTAVA is a user-friendly, open-source toolbox that can analyse retinal OCTA images from various instruments. The toolbox delivers seven microvascular metrics for the whole image or subregions and six metrics characterising the foveal avascular zone. We validate OCTAVA using images collected by four commercial OCTA instruments demonstrating robust performance across datasets from different instruments acquired at different sites from different study cohorts. We show that OCTAVA delivers values for retinal microvascular metrics comparable to the literature and reduces their variation between studies compared to their commercial equivalents. By making OCTAVA publicly available, we aim to expand standardised research and thereby improve the reproducibility of quantitative analysis of retinal microvascular imaging. Such improvements will help to better identify more reliable and sensitive biomarkers of ocular and systemic diseases.


Subject(s)
Macula Lutea , Retinal Vessels , Reproducibility of Results , Fluorescein Angiography/methods , Microvessels , Tomography, Optical Coherence/methods
3.
Sci Adv ; 9(27): eadh5435, 2023 Jul 07.
Article in English | MEDLINE | ID: mdl-37418534

ABSTRACT

The penetration depth of optical coherence tomography (OCT) reaches well beyond conventional microscopy; however, signal reduction with depth leads to rapid degradation of the signal below the noise level. The pursuit of imaging at depth has been largely approached by extinguishing multiple scattering. However, in OCT, multiple scattering substantially contributes to image formation at depth. Here, we investigate the role of multiple scattering in OCT image contrast and postulate that, in OCT, multiple scattering can enhance image contrast at depth. We introduce an original geometry that completely decouples the incident and collection fields by introducing a spatial offset between them, leading to preferential collection of multiply scattered light. A wave optics-based theoretical framework supports our experimentally demonstrated improvement in contrast. The effective signal attenuation can be reduced by more than 24 decibels. Notably, a ninefold enhancement in image contrast at depth is observed in scattering biological samples. This geometry enables a powerful capacity to dynamically tune for contrast at depth.


Subject(s)
Microscopy , Tomography, Optical Coherence , Tomography, Optical Coherence/methods , Optics and Photonics , Scattering, Radiation
4.
Sci Rep ; 13(1): 1122, 2023 01 20.
Article in English | MEDLINE | ID: mdl-36670141

ABSTRACT

Optical coherence tomography angiography (OCTA) is a non-invasive, high-resolution imaging modality with growing application in dermatology and microvascular assessment. Accepted reference values for OCTA-derived microvascular parameters in skin do not yet exist but need to be established to drive OCTA into the clinic. In this pilot study, we assess a range of OCTA microvascular metrics at rest and after post-occlusive reactive hyperaemia (PORH) in the hands and feet of 52 healthy people and 11 people with well-controlled type 2 diabetes mellitus (T2DM). We calculate each metric, measure test-retest repeatability, and evaluate correlation with demographic risk factors. Our study delivers extremity-specific, age-dependent reference values and coefficients of repeatability of nine microvascular metrics at baseline and at the maximum of PORH. Significant differences are not seen for age-dependent microvascular metrics in hand, but they are present for several metrics in the foot. Significant differences are observed between hand and foot, both at baseline and maximum PORH, for most of the microvascular metrics with generally higher values in the hand. Despite a large variability over a range of individuals, as is expected based on heterogeneous ageing phenotypes of the population, the test-retest repeatability is 3.5% to 18% of the mean value for all metrics, which highlights the opportunities for OCTA-based studies in larger cohorts, for longitudinal monitoring, and for assessing the efficacy of interventions. Additionally, branchpoint density in the hand and foot and changes in vessel diameter in response to PORH stood out as good discriminators between healthy and T2DM groups, which indicates their potential value as biomarkers. This study, building on our previous work, represents a further step towards standardised OCTA in clinical practice and research.


Subject(s)
Diabetes Mellitus, Type 2 , Diabetic Retinopathy , Humans , Pilot Projects , Diabetes Mellitus, Type 2/diagnostic imaging , Tomography, Optical Coherence/methods , Angiography , Risk Factors , Fluorescein Angiography/methods , Retinal Vessels
5.
Life (Basel) ; 12(12)2022 Dec 04.
Article in English | MEDLINE | ID: mdl-36556388

ABSTRACT

Femoral artery (FA) endothelial function is a promising biomarker of lower extremity vascular health for peripheral artery disease (PAD) prevention and treatment; however, the impact of age on FA endothelial function has not been reported in healthy adults. Therefore, we evaluated the reproducibility and acceptability of flow-mediated dilation (FMD) in the FA and brachial artery (BA) (n = 20) and performed cross-sectional FA- and BA-FMD measurements in healthy non-smokers aged 22−76 years (n = 50). FMD protocols demonstrated similar good reproducibility. Leg occlusion was deemed more uncomfortable than arm occlusion; thigh occlusion was less tolerated than forearm and calf occlusion. FA-FMD with calf occlusion was lower than BA-FMD (6.0 ± 1.1% vs 6.4 ± 1.3%, p = 0.030). Multivariate linear regression analysis indicated that age (−0.4%/decade) was a significant independent predictor of FA-FMD (R2 = 0.35, p = 0.002). The age-dependent decline in FMD did not significantly differ between FA and BA (pinteraction agexlocation = 0.388). In older participants, 40% of baseline FA wall shear stress (WSS) values were <5 dyne/cm2, which is regarded as pro-atherogenic. In conclusion, endothelial function declines similarly with age in the FA and the BA in healthy adults. The age-dependent FA enlargement results in a critical decrease in WSS that may explain part of the age-dependent predisposition for PAD.

6.
Food Funct ; 13(20): 10439-10448, 2022 Oct 17.
Article in English | MEDLINE | ID: mdl-36164983

ABSTRACT

Background: diabetes and age are major risk factors for the development of lower extremity peripheral artery disease (PAD). Cocoa flavanol (CF) consumption is associated with lower risk for PAD and improves brachial artery (BA) endothelial function. Objectives: to assess if femoral artery (FA) endothelial function and dermal microcirculation are impaired in individuals with type 2 diabetes mellitus (T2DM) and evaluate the acute effect of CF consumption on FA endothelial function. Methods: in a randomised, controlled, double-blind, cross-over study, 22 individuals (n = 11 healthy, n = 11 T2DM) without cardiovascular disease were recruited. Participants received either 1350 mg CF or placebo capsules on 2 separate days in random order. Endothelial function was measured as flow-mediated dilation (FMD) using ultrasound of the common FA and the BA before and 2 hours after interventions. The cutaneous microvasculature was assessed using optical coherence tomography angiography. Results: baseline FA-FMD and BA-FMD were significantly lower in T2DM (FA: 3.2 ± 1.1% [SD], BA: 4.8 ± 0.8%) compared to healthy (FA: 5.5 ± 0.7%, BA: 6.0 ± 0.8%); each p < 0.001. Whereas in healthy individuals FA-FMD did not significantly differ from BA-FMD (p = 0.144), FA-FMD was significantly lower than BA-FMD in T2DM (p = 0.003) indicating pronounced and additional endothelial dysfunction of lower limb arteries (FA-FMD/BA-FMD: 94 ± 14% [healthy] vs. 68 ± 22% [T2DM], p = 0.007). The baseline FA blood flow rate (0.42 ± 0.23 vs. 0.73 ± 0.35 l min-1, p = 0.037) and microvascular dilation in response to occlusion in hands and feet were significantly lower in T2DM subjects than in healthy ones. CF increased both FA- and BA-FMD at 2 hours, compared to placebo, in both healthy and T2DM subgroups (FA-FMD effect: 2.9 ± 1.4%, BA-FMD effect 3.0 ± 3.5%, each pintervention< 0.001). In parallel, baseline FA blood flow and microvascular diameter significantly increased in feet (3.5 ± 3.5 µm, pintervention< 0.001) but not hands. Systolic blood pressure and pulse wave velocity significantly decreased after CF in both subgroups (-7.2 ± 9.6 mmHg, pintervention = 0.004; -1.3 ± 1.3 m s-1, pintervention = 0.002). Conclusions: individuals with T2DM exhibit decreased endothelial function that is more pronounced in the femoral than in the brachial artery. CFs increase endothelial function not only in the BA but also the FA both in healthy individuals and in those with T2DM who are at increased risk of developing lower extremity PAD and foot ulcers.


Subject(s)
Cacao , Diabetes Mellitus, Type 2 , Brachial Artery/physiology , Cross-Over Studies , Diabetes Mellitus, Type 2/drug therapy , Endothelium, Vascular , Humans , Lower Extremity/blood supply , Polyphenols/pharmacology , Pulse Wave Analysis , Vasodilation
7.
PLoS One ; 16(12): e0261052, 2021.
Article in English | MEDLINE | ID: mdl-34882760

ABSTRACT

Optical coherence tomography angiography (OCTA) performs non-invasive visualization and characterization of microvasculature in research and clinical applications mainly in ophthalmology and dermatology. A wide variety of instruments, imaging protocols, processing methods and metrics have been used to describe the microvasculature, such that comparing different study outcomes is currently not feasible. With the goal of contributing to standardization of OCTA data analysis, we report a user-friendly, open-source toolbox, OCTAVA (OCTA Vascular Analyzer), to automate the pre-processing, segmentation, and quantitative analysis of en face OCTA maximum intensity projection images in a standardized workflow. We present each analysis step, including optimization of filtering and choice of segmentation algorithm, and definition of metrics. We perform quantitative analysis of OCTA images from different commercial and non-commercial instruments and samples and show OCTAVA can accurately and reproducibly determine metrics for characterization of microvasculature. Wide adoption could enable studies and aggregation of data on a scale sufficient to develop reliable microvascular biomarkers for early detection, and to guide treatment, of microvascular disease.


Subject(s)
Algorithms , Forearm/diagnostic imaging , Hand/diagnostic imaging , Image Processing, Computer-Assisted/methods , Microvessels/diagnostic imaging , Tomography, Optical Coherence/methods , Adult , Forearm/blood supply , Hand/blood supply , Healthy Volunteers , Humans , Middle Aged , Signal-To-Noise Ratio
8.
Nat Commun ; 9(1): 2079, 2018 05 25.
Article in English | MEDLINE | ID: mdl-29802258

ABSTRACT

Optical tweezers are an invaluable tool for non-contact trapping and micro-manipulation, but their ability to facilitate high-throughput volumetric microrheology of biological samples for mechanobiology research is limited by the precise alignment associated with the excitation and detection of individual bead oscillations. In contrast, radiation pressure from a low-numerical aperture optical beam can apply transversely localized force over an extended depth range. Here we present photonic force optical coherence elastography (PF-OCE), leveraging phase-sensitive interferometric detection to track sub-nanometer oscillations of beads, embedded in viscoelastic hydrogels, induced by modulated radiation pressure. Since the displacements caused by ultra-low radiation-pressure force are typically obscured by absorption-mediated thermal effects, mechanical responses of the beads were isolated after independent measurement and decoupling of the photothermal response of the hydrogels. Volumetric imaging of bead mechanical responses in hydrogels with different agarose concentrations by PF-OCE was consistent with bulk mechanical characterization of the hydrogels by shear rheometry.


Subject(s)
Elasticity Imaging Techniques/methods , Imaging, Three-Dimensional/methods , Microscopy/methods , Optical Tweezers , Tomography, Optical Coherence/methods , Biomechanical Phenomena , Hydrogels , Photons , Rheology/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...