Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Jpn J Thorac Cardiovasc Surg ; 49(5): 273-8, 2001 May.
Article in English | MEDLINE | ID: mdl-11431944

ABSTRACT

OBJECTIVE: We evaluated the effect of tranexamic acid on blood loss in patients undergoing elective cardiopulmonary bypass for coronary artery bypass surgery. METHODS: We randomly assigned 7 of 14 patients to a group receiving 50 mg/kg tranexamic acid before skin incision and after the start of cardiopulmonary bypass and the other 7 as controls. RESULTS: Intraoperative and postoperative blood loss was significantly (p = 0.025) reduced in the tranexamic acid group. A similar decrease in platelet count was observed during cardiopulmonary bypass in both groups. Antithrombin III was significantly (p = 0.013) decreased in both groups during cardiopulmonary bypass. Antithrombin III and thrombin-antithrombin III complexes were significantly (p = 0.001) increased after protamine administration. A significant (p = 0.010) decrease in alpha 2-plasmin inhibitor was noted at 5 and 60 minutes after the start of cardiopulmonary bypass in the tranexamic acid group. alpha 2-plasmin inhibitor-plasmin complexes were significantly (p = 0.001) increased after the start of cardiopulmonary bypass in both groups and were significantly (p = 0.012) decreased after protamine administration. alpha 2-plasmin inhibitor-plasmin complexes in the tranexamic acid group were significantly (p = 0.030) lower than in controls 60 minutes after the start of cardiopulmonary bypass, just prior to the end of cardiopulmonary bypass, and after protamine administration. CONCLUSIONS: These findings showed that tranexamic acid administration effectively prevented perioperative blood loss without thromboembolic complications and that tranexamic acid during cardiopulmonary bypass coordinates the anticoagulative effect of heparin and the antifibrinolytic effect of tranexamic acid.


Subject(s)
Antifibrinolytic Agents/pharmacology , Blood Loss, Surgical/prevention & control , Cardiopulmonary Bypass , Tranexamic Acid/pharmacology , Aged , Analysis of Variance , Antithrombin III , Female , Hematocrit , Humans , Male , Middle Aged , Peptide Hydrolases/blood , Platelet Count , alpha-2-Antiplasmin/analysis
2.
Artif Organs ; 25(2): 146-50, 2001 Feb.
Article in English | MEDLINE | ID: mdl-11251480

ABSTRACT

Tumor necrosis factor-alpha (TNF-alpha) release has been implicated in a sepsis-like syndrome following cardiopulmonary bypass (CPB). This also may be important in patients who have had a left ventricular assist device (LVAD) implanted. This report investigates the effect of reducing systemic blood flow on hemodynamic response, mixed venous oxygen saturation (SvO(2)), and the release of TNF-alpha. LVADs were implanted in 9 pigs. The aorta was clamped, and thus the LVAD flow represented the entire systemic blood flow. Plasma TNF-alpha in the femoral artery (FA) and superior mesenteric vein (SMV) was measured at baseline and following systemic blood flow changes. Simultaneously, hemodynamic parameters and oxygen saturation in the pulmonary artery (SvO(2)) were measured. Following reductions in systemic blood flow, plasma TNF-alpha increased gradually to a maximum level at a systemic blood flow of 20%. There was no significant difference between TNF-alpha levels in the SMV and the FA. There was a significant (p < 0.05) correlation between cardiac index, stroke volume index, and TNF-alpha. The SvO(2) decreased significantly (p < 0.05) at a systemic blood flow of 30 and 20%. A rise in TNF-alpha occurred when the SvO(2) was less than 75%. The data demonstrate that a reduction in systemic blood flow causes an increase in plasma TNF-alpha. This can lead to the development of a sepsis-like syndrome in a group of patients who already are hemodynamically compromised. While weaning short-term LVAD support, rapid diminution of the cardiac output and the pump flow must be avoided.


Subject(s)
Heart-Assist Devices , Hemodynamics/physiology , Oxygen/blood , Tumor Necrosis Factor-alpha/analysis , Analysis of Variance , Animals , Blood Flow Velocity , Disease Models, Animal , Heart Ventricles , Probability , Sensitivity and Specificity , Statistics, Nonparametric , Swine
3.
Artif Organs ; 25(1): 53-7, 2001 Jan.
Article in English | MEDLINE | ID: mdl-11167560

ABSTRACT

We previously demonstrated that tumor necrosis factor-alpha (TNF-alpha) increased following a reduction in systemic blood flow to 60% or less of the original cardiac output using a left ventricular assist device (LVAD). The aim of this study was to investigate the effect of reducing systemic blood flow on tissue oxygenation in the gastrointestinal tract (GIT) and the consequences of this on TNF-alpha release. LVADs were implanted in 9 pigs. The aorta was clamped, and thus the LVAD flow represented the entire systemic blood flow. Plasma TNF-alpha of the superior mesenteric vein was measured at baseline and during systemic blood flow changes. Simultaneously, pH, lactate, oxygen delivery index (DO(2)I), oxygen consumption index (VO(2)I), and oxygen extraction (O(2)ER) in the GIT were measured. The pH decreased and the lactate level increased significantly (p < 0.05) at a systemic blood flow of 50% or less. The VO(2)I was positively correlated with DO(2)I. The O(2)ER increased significantly (p < 0.05) with reductions in systemic blood flow to 30% or less. There was a significant (p < 0.01) correlation between TNF-alpha and O(2)ER at levels higher than 55%. These data demonstrate that the GIT oxygenation is inadequate with a reduction in systemic blood flow to 50% and that GIT oxygenation becomes critical at a reduction of 30%. During LVAD weaning, careful attention must be given to the GIT. The pH and lactate may be good markers of the adequacy of tissue oxygenation in the GIT.


Subject(s)
Heart-Assist Devices , Hemodynamics , Intestinal Mucosa/metabolism , Oxygen Consumption , Oxygen/blood , Tumor Necrosis Factor-alpha/metabolism , Animals , Blood Flow Velocity , Cardiac Output , Femoral Artery , Hydrogen-Ion Concentration , Intestines/blood supply , Lactic Acid/blood , Mesenteric Artery, Superior , Swine
4.
Jpn J Thorac Cardiovasc Surg ; 48(9): 583-5, 2000 Sep.
Article in English | MEDLINE | ID: mdl-11030131

ABSTRACT

Here, we report a case of a two-day-old neonate with total anomalous pulmonary venous connection to the innominate vein and a bronchogenic cyst arising from the trachea. Antenatal echocardiography had delineated both cardiac and extracardiac lesions, and a repeated examination on the day of birth disclosed progressive enlargement in the cyst in a manner so as to obstruct the innominate vein. On the second day of life, the patient underwent complete correction of the cardiac lesion and total excision of the cyst. The patient recovered uneventfully and was discharged on the thirteenth postoperative day.


Subject(s)
Bronchogenic Cyst/complications , Pulmonary Veins/abnormalities , Brachiocephalic Veins/abnormalities , Bronchogenic Cyst/surgery , Cardiac Surgical Procedures/methods , Humans , Infant, Newborn , Male , Pulmonary Veins/surgery
5.
Ann Thorac Surg ; 65(3): 663-6, 1998 Mar.
Article in English | MEDLINE | ID: mdl-9527192

ABSTRACT

BACKGROUND: Little is known about left ventricular performance during venoarterial bypass and left heart bypass (LHB) after cross-clamping the descending thoracic aorta. We evaluated the effects of venoarterial bypass and LHB on ventricular load optimization and left ventricular work efficiency. METHODS: We used the left ventricular conductance catheter and a micromanometer in 7 anesthetized mongrel dogs. We assessed preload by the end-diastolic volume, afterload by the effective arterial elastance, and left ventricular contractile properties by the slope of the end-systolic pressure-volume relationship. In addition, optimal ventricular arterial coupling (ratio of effective arterial elastance to slope of end-systolic pressure-volume relationship) and left ventricular work efficiency (ratio of external work to pressure-volume area) were calculated. RESULTS: The decrease in preload was much greater with LHB than venoarterial bypass. There were no significant differences in afterload and left ventricular contractility between venoarterial bypass and LHB. The ventricular arterial coupling during LHB was near 0.50 (0.69 +/- 0.16) in the "best heart" condition (effective arterial elastance = slope of end-systolic pressure-volume relationship/2), whereas the work efficiency during LHB was at maximum (0.73 +/- 0.12). CONCLUSIONS: We conclude that LHB has a more beneficial effect on left ventricular performance after cross-clamping of the descending thoracic aorta.


Subject(s)
Assisted Circulation , Ventricular Function, Left/physiology , Animals , Cardiac Catheterization , Dogs , Hemodynamics , Manometry
6.
Appl Environ Microbiol ; 62(6): 1903-7, 1996 Jun.
Article in English | MEDLINE | ID: mdl-16535329

ABSTRACT

During the screening of microbial proline hydroxylases, novel proline 3-hydroxylase activities, which hydroxylate free l-proline to free cis-3-hydroxy-l-proline, were detected in whole cells of Streptomyces sp. strain TH1 and Bacillus sp. strains TH2 and TH3 from 3,000 strains isolated from soil. The reaction product was purified from a reaction mixture of Streptomyces sp. strain TH1, and its chemical structure was identified as cis-3-hydroxy-l-proline by instrumental analyses. Proline 3-hydroxylase activity was also detected in Streptomyces canus ATCC 12647 which produces the 3-hydroxyproline-containing peptide antibiotic telomycin. Bacillus sp. strains TH2 and TH3 were found to accumulate cis-3-hydroxy-l-proline in culture media at 426 and 352 (mu)M, respectively. It was suggested that hydroxylation occurred in a highly regio- and stereospecific manner at position 3 of l-proline because no hydroxylation product other than cis-3-hydroxy-l-proline was observed. Proline 3-hydroxylases of these strains were first characterized on crude enzyme preparations. Since 2-oxoglutarate and ferrous ion were required for hydroxylation of l-proline, these 3-hydroxylases were thought to belong to a family of 2-oxoglutarate-related dioxygenases. The reaction was inhibited by Co(sup2+), Zn(sup2+), and Cu(sup2+). l-Ascorbic acid accelerated the reaction. The optimum pH and temperature were 7.5 and 35(deg)C, respectively.

7.
Ann Thorac Surg ; 61(3): 817-22, 1996 Mar.
Article in English | MEDLINE | ID: mdl-8619699

ABSTRACT

BACKGROUND: Although hemodynamic stability and renal function are important and are monitored closely in patients with implanted left ventricular assist devices (LVAD), the gastrointestinal tract may be underestimated in the early postoperative period with regard to adequate perfusion. We investigated renal, intestinal, and whole body metabolic changes in response to variations in LVAD flow and inspired oxygen concentration (FiO2). METHODS: Left ventricular assist devices were implanted in 10 adult pigs (weight, 55 +/- 1.76 kg). Renal vein (RV), superior mesenteric vein (SMV), and pulmonary artery (PA) blood oxygen saturation and lactate concentration were measured and used as tissue perfusion markers. These measurements were made at baseline and after changes in LVAD flow or FiO2. RESULTS: Oxygen saturation in the PA, SMV, and RV decreased significantly after a reduction in LVAD flow (P < 0.05), with a greater reduction in the SMV than in the PA and RV (p < 0.05 at LVAD flow 3.5L/min; p < 0.01 at LVAD flow 2.0 and 1.0 L/min). The lactate concentration in the PA and SMV increased significantly (p < 0.01) with decreased flow, with a greater increase in the SMV than in the PA (p< 0.05), whereas it remained unchanged in the RV. Oxygen saturation in the PA, SMV, and RV decreased significantly after a reduction in FiO2 (p < 0.05). Lactate concentration in the PA, SMV, and RV increased significantly at FiO2 of 0.10 (p < 0.05). Lactate concentration in the PA and SMV was significantly higher than that in the RV at Fi)2 of 0.10 (p < 0.01). CONCLUSIONS: The results show that the gastrointestinal tract is at high risk during low perfusion or low FiO2, whereas the kidneys' metabolic function appears to be less disturbed. In clinical practice, this emphasizes the need to ensure adequate blood flow and respiratory function, especially after extubation, in patients with implanted LVAD. This might avoid intestinal ischemia and subsequent endotoxemia. Gastrointestinal tonometry may help in the assessment of intestinal perfusion.


Subject(s)
Digestive System Physiological Phenomena , Heart-Assist Devices , Oxygen/blood , Animals , Hemodynamics , Swine
8.
J Vasc Surg ; 20(5): 826-33, 1994 Nov.
Article in English | MEDLINE | ID: mdl-7966819

ABSTRACT

PURPOSE: This clinical study was to evaluate changes of evoked spinal cord potentials (ESCPs) elicited by direct spinal cord stimulation and to determine their relation to spinal cord ischemia during aortic aneurysm surgery. METHODS: We monitored descending ESCPs from the thoracic spinal cord and lumbar enlargement after cervical spinal cord stimulation (thoracic descending ESCP and lumbar descending ESCP), and segmental ESCP at lumbar enlargement elicited by bilateral tibial nerve stimulation in 22 aortic aneurysm surgical operations. RESULTS: ESCP changes were classified into three types: (1) decrease of amplitude in lumbar descending ESCP and segmental ESCP; (2) decrease of amplitude in segmental ESCP alone; (3) decrease of amplitude in all ESCPs. The late negative waves of both lumbar descending ESCP and segmental ESCP were more sensitive than other components of ESCPs. Postoperative paraplegia occurred in the two cases that showed persistent diminution of amplitude in the late negative waves. Segmental ESCP was less reliable than lumbar descending ESCP, because it depended entirely on the adequate perfusion of the lower extremities. CONCLUSIONS: Lumbar descending ESCP was the best method for the spinal cord ischemia during aortic aneurysm surgery. Spinal cord ischemia could be detected by diminution in the amplitude of the late negative wave of lumbar descending ESCP. The recovery amplitude of the late negative wave after declamping correlated with the neurologic outcome.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Intraoperative Complications/physiopathology , Ischemia/physiopathology , Monitoring, Intraoperative , Spinal Cord/blood supply , Aged , Electrodes, Implanted , Evoked Potentials, Somatosensory , Female , Humans , Intraoperative Complications/diagnosis , Intraoperative Complications/etiology , Intraoperative Complications/prevention & control , Ischemia/diagnosis , Ischemia/etiology , Ischemia/prevention & control , Male , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL
...