Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 20(16)2020 Aug 07.
Article in English | MEDLINE | ID: mdl-32784793

ABSTRACT

Electrochemical spectroscopy enables rapid, sensitive, and label-free analyte detection without the need of extensive and laborious labeling procedures and sample preparation. In addition, with the emergence of commercially available screen-printed electrodes (SPEs), a valuable, disposable alternative to costly bulk electrodes for electrochemical (bio-)sensor applications was established in recent years. However, applications with bare SPEs are limited and many applications demand additional/supporting structures or flow cells. Here, high-resolution 3D printing technology presents an ideal tool for the rapid and flexible fabrication of tailor-made, experiment-specific systems. In this work, flow cells for SPE-based electrochemical (bio-)sensor applications were designed and 3D printed. The successful implementation was demonstrated in an aptamer-based impedimetric biosensor approach for the detection of Escherichia coli (E. coli) Crooks strain as a proof of concept. Moreover, further developments towards a 3D-printed microfluidic flow cell with an integrated micromixer also illustrate the great potential of high-resolution 3D printing technology to enable homogeneous mixing of reagents or sample solutions in (bio-)sensor applications.


Subject(s)
Biosensing Techniques , Electrochemical Techniques , Escherichia coli , Electrodes , Printing, Three-Dimensional
2.
Analyst ; 145(14): 4991-5003, 2020 Jul 21.
Article in English | MEDLINE | ID: mdl-32519701

ABSTRACT

Over the past decade aptamers have emerged as a promising class of bioreceptors for biosensing applications with significant advantages over conventional antibodies. However, experimental studies comparing aptasensors and immunosensors, under equivalent conditions, are limited and the results are inconclusive, in terms of benefits and limitations of each bioreceptor type. In the present work, the performance of aptamer and antibody bioreceptors for the detection of a his-tagged protein, used as a model target, is compared. The bioreceptors are immobilized onto a nanostructured porous silicon (PSi) thin film, used as the optical transducer, and the target protein is detected in a real-time and label-free format by reflective interferometric Fourier transform spectroscopy. For the antibodies, random-oriented immobilization onto the PSi nanostructure results in a poor biosensing performance. Contrary, Fc-oriented immobilization of the antibodies shows a similar biosensing performance to that exhibited by the aptamer-based biosensor, in terms of binding rate, dynamic detection range, limit of detection and selectivity. The aptasensor outperforms in terms of its reusability and storability, while the immunosensor could not be regenerated for subsequent experiments.


Subject(s)
Aptamers, Nucleotide , Biosensing Techniques , Immunoassay , Porosity , Silicon
3.
ACS Sens ; 4(1): 242-249, 2019 01 25.
Article in English | MEDLINE | ID: mdl-30604619

ABSTRACT

In this work, we report digital loop-mediated isothermal amplification (LAMP) or reverse-transcription LAMP (RT-LAMP) on a commercial membrane, without the need for complex chip fabrication or use of specialized equipment. Due to the pore size distribution, the theoretical error for digital LAMP on these membranes was analyzed, using a combination of Random Distribution Model and Multivolume Theory. A facile peel-off process was developed for effective droplet formation on the commercial track-etched polycarbonate (PCTE) membrane. Each pore functions as an individual nanoreactor for single DNA amplification. Absolute quantification of bacteria genomic DNA was realized with a dynamic range from 11 to 1.1 × 105 copies/µL. One-step digital RT-LAMP was also successfully performed on the membrane for the quantification of MS2 virus in wastewater. With the introduction of new probes, the positive pores can be easily distinguished from negative ones with 100 times difference in fluorescence intensities. Finally, the cost of a disposable membrane is less than $0.10/piece, which, to the best of our knowledge, is the most inexpensive way to perform digital LAMP. The membrane system offers opportunities for point-of-care users or common laboratories to perform digital quantification, single cell analysis, or other bioassays in an inexpensive, flexible, and simplified way.


Subject(s)
DNA, Bacterial/analysis , DNA, Viral/analysis , Polycarboxylate Cement/chemistry , Enterococcus faecalis/genetics , Escherichia coli/genetics , Levivirus/genetics , Limit of Detection , Microfluidic Analytical Techniques/methods , Nanopores , Nucleic Acid Amplification Techniques/methods , Salmonella typhimurium/genetics , Wastewater/analysis , Wastewater/virology
4.
Small ; 15(2): e1804326, 2019 01.
Article in English | MEDLINE | ID: mdl-30548194

ABSTRACT

One of the basic operations in microfluidic systems for biological and chemical applications is the rapid mixing of different fluids. However, flow profiles in microfluidic systems are laminar, which means molecular diffusion is the only mixing effect. Therefore, mixing structures are crucial to enable more efficient mixing in shorter times. Since traditional microfabrication methods remain laborious and expensive, 3D printing has emerged as a potential alternative for the fabrication of microfluidic devices. In this work, five different passive micromixers known from literature are redesigned in comparable dimensions and manufactured using high-definition MultiJet 3D printing. Their mixing performance is evaluated experimentally, using sodium hydroxide and phenolphthalein solutions, and numerically via computational fluid dynamics. Both experimental and numerical analysis results show that HC and Tesla-like mixers achieve complete mixing after 0.99 s and 0.78 s, respectively, at the highest flow rate (Reynolds number (Re) = 37.04). In comparison, Caterpillar mixers exhibit a lower mixing rate with complete mixing after 1.46 s and 1.9 s. Furthermore, the HC mixer achieves very good mixing performances over all flow rates (Re = 3.7 to 37.04), while other mixers show improved mixing only at higher flow rates.

5.
ACS Nano ; 12(10): 10281-10290, 2018 10 23.
Article in English | MEDLINE | ID: mdl-30211534

ABSTRACT

In this work, we introduce an asymmetric membrane as a simple and robust nanofluidic platform for digital detection of single pathogenic bacteria directly in 10 mL of unprocessed environmental water samples. The asymmetric membrane, consisting of uniform micropores on one side and a high density of vertically aligned nanochannels on the other side, was prepared within 1 min by a facile method. The single membrane covers all the processing steps from sample concentration, purification, and partition to final digital loop-mediated isothermal amplification (LAMP). By simple filtration, bacteria were enriched and partitioned inside the micropores, while inhibitors typically found in the environmental samples ( i.e., proteins, heavy metals, and organics) were washed away through the nanochannels. Meanwhile, large particles, indigenous plankton, and positively charged pollutants in the samples were excluded by using a sacrificial membrane stacked on top. After initial filtration, modified LAMP reagents, including NaF and lysozyme, were loaded onto the membrane. Each pore in the asymmetric membrane functioned as an individual nanoreactor for selective, rapid, and efficient isothermal amplification of single bacteria, generating a bright fluorescence for direct counting. Even though high levels of inhibitors were present, absolute quantification of Escherichia coli and Salmonella directly in an unprocessed environmental sample (seawater and pond water) was achieved within 1 h, with sensitivity down to single cell and a dynamic range of 0.3-10000 cells/mL. The simple and low-cost analysis platform described herein has an enormous potential for the detection of pathogens, exosomes, stem cells, and viruses as well as single-cell heterogeneity analysis in environmental, food, and clinical research.


Subject(s)
Escherichia coli/isolation & purification , Salmonella typhi/isolation & purification , Water Microbiology , Cells, Cultured , Escherichia coli/cytology , Salmonella typhi/cytology
6.
Environ Sci Technol ; 52(11): 6399-6407, 2018 06 05.
Article in English | MEDLINE | ID: mdl-29738236

ABSTRACT

Model coliphages (e.g., ΦX174, MS2, and PRD1) have been widely used as surrogates to study the fate and transport of pathogenic viruses in the environment and during wastewater treatment. Two groups of coliphages (F-specific and somatic) are being explored as indicators of viral fecal pollution in ambient water. However, the detection and quantification of coliphages still largely rely on time-consuming culture-based plaque assays. In this study, we developed an in-gel loop-mediated isothermal amplification (gLAMP) system enabling coliphage MS2 quantification within 30 min using standard laboratory devices. Viral particles (MS2) were immobilized with LAMP reagents in polyethylene glycol hydrogel, and then viral RNAs were amplified through a LAMP reaction. Due to the restriction effect of the hydrogel matrix, one viral particle would only produce one amplicon dot. Therefore, the sample virus concentrations can be determined based on the number of fluorescent amplicon dots using a smartphone for imaging. The method was validated by using artificially spiked and naturally contaminated water samples. gLAMP results were shown to correlate well with plaque assay counts ( R2 = 0.984, p < 0.05) and achieved similar sensitivity to quantitative reverse-transcription polymerase chain reaction (RT-qPCR; 1 plaque-forming unit per reaction). Moreover, gLAMP demonstrated a high level of tolerance against inhibitors naturally present in wastewater, in which RT-qPCR was completely inhibited. Besides MS2, gLAMP can also be used for the quantification of other microbial targets (e.g., Escherichia coli and Salmonella). Considering its simplicity, sensitivity, rapidity, and versatility, gLAMP holds great potential for microbial water-quality analysis, especially in resource-limited settings.


Subject(s)
Levivirus , Smartphone , Coliphages , Real-Time Polymerase Chain Reaction , Sensitivity and Specificity , Water Pollution
7.
Talanta ; 172: 199-205, 2017 Sep 01.
Article in English | MEDLINE | ID: mdl-28602295

ABSTRACT

Sensitive and specific detection and quantification of small molecules often remain challenging. We developed a novel magnetic bead-based aptamer-assisted real-time PCR (Apta-qPCR) assay to provide a versatile platform for quantification of small molecules. The assay has been realized for the detection of ATP as a model system. The assay relies on a combination of qPCR with the target-induced dissociation (TID) of ATP aptamer from an oligonucleotide, complementary to the ATP binding site of the aptamer. The complementary oligonucleotide was immobilized on deoxythymidine (dT)-modified magnetic beads (dT-beads) and hybridized with the aptamer. The presence of ATP resulted in dissociation of the aptamer from the dT-beads and the dissociated aptamer was quantified using qPCR. The Apta-qPCR assay was able to detect 17nM ATP with a broad dynamic range from 50nM to 5mM. The assay is label-free, and real-time PCR-based detection of aptamer facilitates high sensitivity. The presented method is highly versatile and can be applied to various aptamer-target pairs to allow detection of a broad range of target analytes.


Subject(s)
Adenosine Triphosphate/analysis , Aptamers, Nucleotide/metabolism , Real-Time Polymerase Chain Reaction/methods , Adenosine Triphosphate/metabolism , HeLa Cells , Humans , Limit of Detection
8.
J Biotechnol ; 257: 171-177, 2017 Sep 10.
Article in English | MEDLINE | ID: mdl-28131857

ABSTRACT

Protein A, which is secreted by and displayed on the cell membrane of Staphylococcus aureus is an important biomarker for S. aureus. Thus, its rapid and specific detection may facilitate the pathogen identification and initiation of proper treatment. Herein, we present a simple, label-free and rapid optical biosensor enabling specific detection of protein A. Protein A-binding aptamer serves as the capture probe and is immobilized onto a nanostructured porous silicon thin film, which serves as the optical transducer element. We demonstrate high sensitivity of the biosensor with a linear detection range between 8 and 23µM. The apparent dissociation constant was determined as 13.98µM and the LoD is 3.17µM. Harnessing the affinity between protein A and antibodies, a sandwich assay format was developed to amplify the optical signal associated with protein A capture by the aptamer. Using this approach, we increase the sensitivity of the biosensor, resulting in a three times lower LoD.


Subject(s)
Aptamers, Nucleotide/chemistry , Biosensing Techniques/methods , Nanostructures/chemistry , Silicon/chemistry , Staphylococcal Protein A/isolation & purification , Antibodies , Immobilization/methods , Immunoglobulin G , Optical Phenomena , Porosity , Sensitivity and Specificity , Staphylococcal Infections/diagnosis , Staphylococcus aureus/metabolism
9.
Anal Chem ; 87(3): 1999-2006, 2015 Feb 03.
Article in English | MEDLINE | ID: mdl-25551423

ABSTRACT

A proof-of-concept for a label-free and reagentless optical biosensing platform based on nanostructured porous silicon (PSi) and aptamers is presented in this work. Aptamers are oligonucleotides (single-stranded DNA or RNA) that can bind their targets with high affinity and specificity, making them excellent recognition elements for biosensor design. Here we describe the fabrication and characterization of aptamer-conjugated PSi biosensors, where a previously characterized his-tag binding aptamer (6H7) is used as model system. Exposure of the aptamer-functionalized PSi to the target proteins as well as to complex fluids (i.e., bacteria lysates containing target proteins) results in robust and well-defined changes in the PSi optical interference spectrum, ascribed to specific aptamer-protein binding events occurring within the nanoscale pores, monitored in real time. The biosensors show exceptional stability and can be easily regenerated by a short rinsing step for multiple biosensing analyses. This proof-of-concept study demonstrates the possibility of designing highly stable and specific label-free optical PSi biosensors, employing aptamers as capture probes, holding immense potential for application in detection of a broad range of targets, in a simple yet reliable manner.


Subject(s)
Aptamers, Nucleotide/chemistry , Biosensing Techniques/instrumentation , Histidine/analysis , Nanostructures/chemistry , Oligopeptides/analysis , Silicon/chemistry , Porosity
SELECTION OF CITATIONS