Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J AOAC Int ; 103(3): 833-842, 2020 Jun 01.
Article in English | MEDLINE | ID: mdl-33241359

ABSTRACT

BACKGROUND: CERTUS Environmental Listeria species Detection Kit (CERTUS EL Detection Kit) is a real-time, bio-contained assay designed to accurately detect Listeria species (L. grayi, L. innocua, L. ivanovii, L. marthii, L. monocytogenes, L. seeligeri, and L. welshimeri) from environmental surface matrixes using an antibody-coupled magnetic microparticle with a Surface Enhanced Raman Spectroscopy (SERS) nanoparticle technology test system paired with proprietary CERTUS EL Selective Growth Media and CERTUS Detection Unit. OBJECTIVE: The method was evaluated for AOAC®Performance Tested MethodSM certification. METHODS: Inclusivity and exclusivity, matrix studies, product consistency and stability were conducted to evaluate the CERTUS EL Detection Kit. RESULTS: In the matrix studies, stainless steel, ceramic tile, plastic (polystyrene) and sealed concrete environmental surfaces (4 × 4" test areas) were tested. No statistically significant differences were found by Probability of Detection analysis (POD) in any of the matrixes when results were compared to the U.S. Food and Drug Administration cultural microbiology reference method for Listeria. The CERTUS EL Detection Kit correctly identified all 50 target Listeria isolates and correctly excluded all 30 non-target strains that were analyzed. Probability of Detection analysis of CERTUS EL Detection Kit robustness, product consistency (lot-to-lot) and stability studies demonstrated no statistically significant differences, and no variation was observed between instruments. CONCLUSIONS: The data collected in these studies demonstrate that the CERTUS EL Detection Kit is a reliable method for the rapid and specific detection of Listeria from stainless steel, ceramic tile, plastic (polystyrene) and sealed concrete environmental surfaces.


Subject(s)
Listeria , Bacteriological Techniques , Environmental Microbiology , Food Microbiology , Plastics , Stainless Steel
2.
J AOAC Int ; 102(4): 1145-1161, 2019 Jul 01.
Article in English | MEDLINE | ID: mdl-30728092

ABSTRACT

Background: Solus One Salmonella is designed to accurately detect Salmonella species (Salmonella enterica subspecies enterica, salamae, arizonae, diarizonae, houtenae, indica, and Salmonella bongori) from select food matrixes and stainless-steel and plastic environmental surfaces. Solus One Salmonella uses an antibody-based technology test system that is paired with media and our proprietary media supplement, the Solus One Salmonella supplement combined with a manual or automated sample preparation method. Objective: Solus One Salmonella was evaluated for inclusivity and exclusivity, and a matrix comparison study was done for six food matrixes (raw beef trim, pasteurized liquid egg, raw salmon, cheddar cheese, Romaine lettuce, nonfat dry milk) and two environmental surfaces (stainless steel and polystyrene). Methods: Solus One Salmonella was compared with the U.S. Food and Drug Administration Bacteriological Analytical Manual Chapter 5: Salmonella (July 2018) and the U.S. Department of Agriculture Food Safety and Inspection Service Microbiology Laboratory Manual, 4.09 (January 2017) in the matrix study. Both the manual and automated sample preparation methods were performed for cheddar cheese and stainless-steel environmental surfaces. Results: For the inclusivity and exclusivity evaluation, Solus One Salmonella correctly detected all 108 target organism isolates and correctly excluded all 35 nontarget strains that were analyzed. Conclusions: In the method comparison study, both Solus One Salmonella manual and automated sample preparation methods demonstrated no significant differences based on probability of detection (POD) statistical analysis between presumptive and confirmed results or between candidate and reference method results for the six food matrixes after 20-22 h and two environmental surfaces after 16-20 h of enrichment time. POD analysis of Solus One Salmonella method robustness, product consistency, and stability studies using the automated sample preparation method demonstrated no statistically significant differences.


Subject(s)
Bacteriological Techniques/methods , Food Contamination/analysis , Polystyrenes , Salmonella/isolation & purification , Stainless Steel , Animals , Cattle , Equipment Contamination , Food Microbiology/methods
3.
Mar Drugs ; 14(11)2016 Oct 27.
Article in English | MEDLINE | ID: mdl-27801777

ABSTRACT

A series of oxy-polybrominated diphenyl ethers (O-PBDEs) has been isolated from the extracts of Miamira magnifica and Miamira miamirana collected from Queensland, Australia. M. magnifica sequesters the new OH-PBDE 1 and six known OH-PBDEs containing four to six bromines (2-7). M. miamirana also accumulates known tribromo- and tetrabromo OMe-PBDEs 8-10 in both mantle and viscera tissues. To date, Miamira is the only genus of the family Chromodorididae that is known to incorporate O-PBDEs, rather than terpenes, in the mantle where the metabolites may play a putative role in chemical defense. The extract of M. magnifica was tested in a brine shrimp lethality assay and exhibited an LD50 of 58 µg/mL.


Subject(s)
Gastropoda/chemistry , Halogenated Diphenyl Ethers/chemistry , Halogenated Diphenyl Ethers/metabolism , Polybrominated Biphenyls/chemistry , Polybrominated Biphenyls/metabolism , Animals , Artemia/drug effects , Feeding Behavior/drug effects , Fishes , Lethal Dose 50 , Queensland , Terpenes/metabolism , Water Pollutants, Chemical
SELECTION OF CITATIONS
SEARCH DETAIL
...