Biomed Opt Express ; 2(8): 2372-82, 2011 Aug 01.
Article in English | MEDLINE | ID: mdl-21833374

ABSTRACT

We demonstrate for the first time that optical coherence tomography (OCT) imaging can reliably distinguish between morphologic features of low risk pancreatic cysts (i.e., pseudocysts and serous cystadenomas) and high risk pancreatic cysts (i.e., mucinous cystic neoplasms and intraductal papillary mucinous neoplasms). In our study fresh pancreatectomy specimens (66) from patients with cystic lesions undergoing surgery were acquired and examined with OCT. A training set of 20 pathology-OCT correlated tissue specimens were used to develop criteria for differentiating between low and high risk cystic lesions. A separate (validation) set of 46 specimens were used to test the OCT criteria by three clinicians, blinded to histopathology findings. Histology was finally used as a 'gold' standard for testing OCT findings. OCT was able to reveal specific morphologic features of pancreatic cysts and thus to differentiate between low-risk and high-risk cysts with over 95% sensitivity and specificity. This pilot study suggests that OCT could be used by clinicians in the future to more reliably differentiate between benign and potentially malignant pancreatic cysts. However, in vivo use of OCT requires a probe that has to fit the bore of the pancreas biopsy needle. Therefore, we have developed such probes and planned to start an in vivo pilot study within the very near future.

2.
Rev Sci Instrum ; 79(11): 114301, 2008 Nov.
Article in English | MEDLINE | ID: mdl-19045902

ABSTRACT

Real-time display of processed Fourier domain optical coherence tomography (FDOCT) images is important for applications that require instant feedback of image information, for example, systems developed for rapid screening or image-guided surgery. However, the computational requirements for high-speed FDOCT image processing usually exceeds the capabilities of most computers and therefore display rates rarely match acquisition rates for most devices. We have designed and developed an image processing system, including hardware based upon a field programmable gated array, firmware, and software that enables real-time display of processed images at rapid line rates. The system was designed to be extremely flexible and inserted in-line between any FDOCT detector and any Camera Link frame grabber. Two versions were developed for spectrometer-based and swept source-based FDOCT systems, the latter having an additional custom high-speed digitizer on the front end but using all the capabilities and features of the former. The system was tested in humans and monkeys using an adaptive optics retinal imager, in zebrafish using a dual-beam Doppler instrument, and in human tissue using a swept source microscope. A display frame rate of 27 fps for fully processed FDOCT images (1024 axial pixels x 512 lateral A-scans) was achieved in the spectrometer-based systems.


Subject(s)
Image Interpretation, Computer-Assisted/instrumentation , Image Processing, Computer-Assisted , Tomography, Optical Coherence/instrumentation , Algorithms , Computer Systems , Electronics , Equipment Design , Fingers/anatomy & histology , Fourier Analysis , Humans , Image Enhancement/instrumentation , Intestines/anatomy & histology , Miniaturization , Software , Spectrophotometry/instrumentation , Tomography, Optical Coherence/methods
3.
Invest Ophthalmol Vis Sci ; 49(5): 2061-70, 2008 May.
Article in English | MEDLINE | ID: mdl-18223243

ABSTRACT

PURPOSE: To describe the fine structure of the fovea in subjects with a history of mild retinopathy of prematurity (ROP) using adaptive optics-Fourier domain optical coherence tomography (AO-FDOCT). METHODS: High-speed, high-resolution AO-FDOCT videos were recorded in subjects with a history of ROP (n = 5; age range, 14-26 years) and in control subjects (n = 5; age range, 18-25 years). Custom software was used to extract foveal pit depth and volume from three-dimensional (3-D) retinal maps. The thickness of retinal layers as a function of retinal eccentricity was measured manually. The retinal vasculature in the parafoveal region was assessed. RESULTS: The foveal pit was wider and shallower in ROP than in control subjects. Mean pit depth, defined from the base to the level at which the pit reaches a lateral radius of 728 microm, was 121 microm compared with 53 microm. Intact, contiguous inner retinal layers overlay the fovea in ROP subjects but were absent in the control subjects. Mean full retinal thickness at the fovea was greater in the subjects with ROP (279.0 microm vs. 190.2 microm). The photoreceptor layer thickness did not differ between ROP and control subjects. An avascular zone was not identified in the subjects with ROP but was present in all the control subjects. CONCLUSIONS: The foveas of subjects with a history of mild ROP have significant structural abnormalities that are probably a consequence of perturbations of neurovascular development.


Subject(s)
Fourier Analysis , Fovea Centralis/pathology , Retinopathy of Prematurity/diagnosis , Tomography, Optical Coherence/methods , Adolescent , Adult , Gestational Age , Humans , Infant, Low Birth Weight , Infant, Newborn , Refraction, Ocular , Retinal Vessels/pathology , Visual Acuity
4.
J Opt Soc Am A Opt Image Sci Vis ; 24(5): 1327-36, 2007 May.
Article in English | MEDLINE | ID: mdl-17429478

ABSTRACT

We have developed a compact, multimodal instrument for simultaneous acquisition of en face quasi-confocal fundus images and adaptive-optics (AO) spectral-domain optical coherence tomography (SDOCT) cross-sectional images. The optical system including all AO and SDOCT components occupies a 60x60 cm breadboard that can be readily transported for clinical applications. The AO component combines a Hartmann-Shack wavefront sensor and a microelectromechanical systems-based deformable mirror to sense and correct ocular aberrations at 15 Hz with a maximum stroke of 4 microm. A broadband superluminescent diode source provides 4 mum depth resolution for SDOCT imaging. In human volunteer testing, we observed up to an 8 dB increase in OCT signal and a corresponding lateral resolution of <10 microm as a result of AO correction.


Subject(s)
Image Enhancement/instrumentation , Lenses , Retinoscopes , Spectrometry, Fluorescence/instrumentation , Tomography, Optical Coherence/instrumentation , Adult , Equipment Design , Equipment Failure Analysis , Female , Humans , Male , Miniaturization , Reproducibility of Results , Sensitivity and Specificity , Spectrometry, Fluorescence/methods , Systems Integration , Tomography, Optical Coherence/methods
5.
J Biomed Opt ; 11(4): 041126, 2006.
Article in English | MEDLINE | ID: mdl-16965154

ABSTRACT

Scanning laser ophthalmoscopy (SLO) is a powerful imaging tool with specialized applications limited to research and ophthalmology clinics due in part to instrument size, cost, and complexity. Conversely, low-cost retinal imaging devices have limited capabilities in screening, detection, and diagnosis of diseases. To fill the niche between these two, a hand-held, nonmydriatic line-scanning laser ophthalmoscope (LSLO) is designed, constructed, and tested on normal human subjects. The LSLO has only one moving part and uses a novel optical approach to produce wide-field confocal fundus images. Imaging modes include multiwavelength illumination and live stereoscopic imaging with a split aperture. Image processing and display functions are controlled with two stacked prototype compact printed circuit boards. With near shot-noise limited performance, the digital LSLO camera requires low illumination power (<500 microW) at near-infrared wavelengths. The line-scanning principle of operation is examined in comparison to SLO and other imaging modes. The line-scanning approach produces high-contrast confocal images with nearly the same performance as a flying-spot SLO. The LSLO may significantly enhance SLO utility for routine use by ophthalmologists, optometrists, general practitioners, and also emergency medical personnel and technicians in the field for retinal disease detection and other diverse applications.


Subject(s)
Image Enhancement/instrumentation , Image Interpretation, Computer-Assisted/instrumentation , Microscopy, Confocal/instrumentation , Ophthalmoscopes , Signal Processing, Computer-Assisted/instrumentation , Computer-Aided Design , Equipment Design , Equipment Failure Analysis , Information Storage and Retrieval/methods , Reproducibility of Results , Sensitivity and Specificity
6.
Opt Express ; 14(8): 3354-67, 2006 Apr 17.
Article in English | MEDLINE | ID: mdl-19516480

ABSTRACT

A retinal imaging instrument that integrates adaptive optics (AO), scanning laser ophthalmoscopy (SLO), and retinal tracking components was built and tested. The system uses a Hartmann-Shack wave-front sensor (HS-WS) and MEMS-based deformable mirror (DM) for AO-correction of high-resolution, confocal SLO images. The system includes a wide-field line-scanning laser ophthalmoscope for easy orientation of the high-magnification SLO raster. The AO system corrected ocular aberrations to <0.1 mum RMS wave-front error. An active retinal tracking with custom processing board sensed and corrected eye motion with a bandwidth exceeding 1 kHz. We demonstrate tracking accuracy down to 6 mum RMS for some subjects (typically performance: 10-15 mum RMS). The system has the potential to become an important tool to clinicians and researchers for vision studies and the early detection and treatment of retinal diseases.

7.
Opt Express ; 14(8): 3377-88, 2006 Apr 17.
Article in English | MEDLINE | ID: mdl-19516482

ABSTRACT

We demonstrate in vivo measurements in human retinal vessels of an experimental parameter, the slope of the low coherence interferometry (LCI) depth reflectivity profile, which strongly correlates with the real value of blood hematocrit. A novel instrument that combines two technologies, spectral domain low coherence interferometry (SDLCI) and retinal tracking, has been developed and used for these measurements. Retinal tracking allows a light beam to be stabilized on retinal vessels, while SDLCI is used for obtaining depth-reflectivity profiles within the investigated vessel. SDLCI backscatter extinction rates are obtained from the initial slope of the A-scan profile within the vessel lumen. The differences in the slopes of the depth reflectivity profiles for different subjects are interpreted as the difference in the scattering coefficient, which is correlated with the number density of red blood cells (RBC) in blood. With proper calibration, it is possible to determine hematocrit in retinal vessels. Ex vivo measurements at various RBC concentrations were performed to calibrate the instrument. Preliminary measurements on several healthy volunteers show estimated hematocrit values within the normal clinical range.

8.
Opt Express ; 14(26): 12909-14, 2006 Dec 25.
Article in English | MEDLINE | ID: mdl-19532184

ABSTRACT

We demonstrate for the first time the integration of two technologies, Spectral Domain Optical Coherence Tomography (SDOCT) and Line-Scanning Laser Ophthalmoscopy (LSLO) into a single compact instrument that shares the same imaging optics and line scan camera for both OCT and LSLO imaging. Co-registered high contrast wide-field en face retinal LSLO and SDOCT images are obtained non-mydriatically with less than 600 microwatts of broadband illumination at 15 frames/sec. The LSLO/SDOCT hybrid instrument could have important applications in clinical ophthalmic diagnostics and emergency medicine.

9.
Opt Express ; 13(20): 7937-47, 2005 Oct 03.
Article in English | MEDLINE | ID: mdl-19498823

ABSTRACT

An upgraded optical coherence tomography system with integrated retinal tracker (TOCT) was developed. The upgraded system uses improved components to extend the tracking bandwidth, fully integrates the tracking hardware into the optical head of the clinical OCT system, and operates from a single software platform. The system was able to achieve transverse scan registration with sub-pixel accuracy (~10 microm). We demonstrate several advanced scan sequences with the TOCT, including composite scans averaged (co-added) from multiple B-scans taken consecutively and several hours apart, en face images collected by summing the A-scans of circular, line, and raster scans, and three-dimensional (3D) retinal maps of the fovea and optic disc. The new system achieves highly accurate OCT scan registration yielding composite images with significantly improved spatial resolution, increased signal-to-noise ratio, and reduced speckle while maintaining well-defined boundaries and sharp fine structure compared to single scans. Precise re-registration of multiple scans over separate imaging sessions demonstrates TOCT utility for longitudinal studies. En face images and 3D data cubes generated from these data reveal high fidelity image registration with tracking, despite scan durations of more than one minute.