Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Surg Endosc ; 35(4): 1741-1748, 2021 04.
Article in English | MEDLINE | ID: mdl-32323015

ABSTRACT

BACKGROUND: Lumen apposing metal stent (LAMS) allows an easy access to peripancreatic fluid collections (PPFCs) and the possibility of performing direct endoscopic necrosectomy (DEN). The aim of our study was to evaluate the safety and efficacy of a new 20-mm LAMS in the management of PPFCs. This novel stent represents the largest diameter LAMS available on the market to date. METHODS: This is an international, multicenter retrospective study involving 20 centers. Consecutive patients who underwent EUS-guided PPFC drainage using a 20-mm LAMS were included. Primary outcomes were technical and clinical success. Secondary outcomes were rate and the severity of adverse events. RESULTS: A total 105 patients underwent PPFC drainage using the new 20-mm LAMS and 106 LAMS were placed. Technical success was 100% (106/106). 7/105 patients died due to causes not related to the stent. Clinical success was achieved in 92/98 patients (93.9%). Significant adverse events occurred in 8/98 patients (8.16%): 4 cases (4.08%) of bleeding, 3 cases (3.06%) of suprainfection, 1 case of gastric outlet obstruction. CONCLUSIONS: This multicenter study demonstrated acceptable rates of technical and clinical success using a new 20-mm LAMS for PPFC, including walled-off pancreatic necrosis (WOPN). The results of our study suggest that a new 20-mm LAMS is non-inferior in terms of safety, efficacy, and adverse events as compared to smaller diameter LAMS in the management of PPFCs, including pancreatic psuedocysts (PP) and WOPN. Randomized controlled studies will be needed to determine the ideal size of LAMS need to achieve the greatest clinical benefit with the minimized risk exposure for this high-risk patient population.


Subject(s)
Body Fluids/chemistry , Endoscopy , Internationality , Pancreas/pathology , Pancreas/surgery , Stents/adverse effects , Adult , Aged , Aged, 80 and over , Drainage , Endosonography , Hemorrhage/etiology , Humans , Male , Middle Aged , Pancreas/diagnostic imaging , Retrospective Studies , Tomography, X-Ray Computed , Treatment Outcome , Young Adult
2.
Gastrointest Endosc ; 91(3): 574-583, 2020 03.
Article in English | MEDLINE | ID: mdl-31759037

ABSTRACT

BACKGROUND AND AIMS: High rates of technical and clinical success were reported for lumen-apposing metal stent (LAMS) placement for peripancreatic fluid collection (PFC) drainage. However, data on the adverse event (AE) rates are heterogeneous. The aim of this study was to evaluate the incidence, severity, management, and risk factors of AEs related to the use of LAMSs for drainage of PFCs in a large cohort of patients. METHODS: This is a multicenter, international, retrospective review from 15 centers of all patients who underwent placement of LAMSs for the management of PFCs. A nested case-control study was conducted in patients with (case) or without (control) AEs. RESULTS: Three hundred thirty-three procedures in 328 patients were performed (5 patients treated with 2 LAMSs). Technical success was achieved in 321 patients (97.9%). Three hundred four patients were finally included in the study (7 excluded for lost to follow-up information; 10 excluded for deaths unrelated to LAMSs). The rate of clinical success was 89.5%. Seventy-nine LAMS-related AEs occurred in 74 of 304 patients (24.3%), after a mean time of 25.3 days (median, 18 days; interquartile range, 6-30) classified as 20 (25.3%) mild, 54 (68.4%) moderate, or 5 (6.3%) severe. On multivariable analysis compared with control subjects, cases were more likely to have walled-off necrosis (WON) versus pancreatic pseudocysts (odds ratio, 2.18; 95% confidence interval, 1.09-4.46; P = .028), whereas cases were less likely to have undergone tract (balloon) dilation (yes vs no; odds ratio, .47; 95% confidence interval, .22-.93; P = .034). CONCLUSIONS: Data from this large international retrospective study confirm that the use of LAMSs for management of PFCs has excellent technical and good clinical success rates. The rate of AEs, however, is not negligible and should be carefully considered before using these stents for drainage of PFCs and in particular for WON. Further prospective studies are needed to confirm these findings. (Clinical trial registration number: NCT03544008.).


Subject(s)
Drainage , Pancreas/surgery , Pancreatic Juice , Pancreatic Pseudocyst/surgery , Pancreatitis/surgery , Prosthesis Implantation/adverse effects , Self Expandable Metallic Stents , Europe/epidemiology , Female , Humans , Incidence , Male , Middle Aged , Necrosis/surgery , Pancreas/pathology , Pancreatic Pseudocyst/epidemiology , Pancreatitis/epidemiology , Prosthesis Implantation/statistics & numerical data , Retrospective Studies , Risk Factors , Self Expandable Metallic Stents/adverse effects , Self Expandable Metallic Stents/statistics & numerical data , United States/epidemiology
SELECTION OF CITATIONS