Water Sci Technol ; 64(7): 1527-32, 2011.
Article in English | MEDLINE | ID: mdl-22179652

ABSTRACT

A membrane electrode assembly (MEA) for microbial fuel cells (MEA-MFC) was developed for continuous electricity production while treating domestic wastewater concurrently. It was optimized via three upgraded versions (noted α, ß and γ) in terms of design (current collectors, hydrophilic separator nature) and operating conditions (hydraulic retention time, external resistance, aeration rate, recirculation). An overall rise of power by over 100% from version α to γ shows the importance of factors such as the choice of proper construction materials and prevention of short-circuits. A power of 2.5 mW was generated with a hydraulic retention time of 2.3 h when a Selemion proton exchange membrane was used as a hydrophilic separator in the MEA and 2.8 mW were attained with a reverse osmosis membrane. The MFC also showed a competitive value of internal resistance (≈40-50 Ω) as compared to the literature, especially considering its large volume (3 L). However, the operation of our system in a complete loop where the anolyte was allowed to trickle over the cathode (version γ) resulted in system failure.


Subject(s)
Bioelectric Energy Sources/standards , Waste Disposal, Fluid/methods , Electrodes , Equipment Design , Waste Disposal, Fluid/instrumentation