Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 23(4)2023 Feb 09.
Article in English | MEDLINE | ID: mdl-36850546

ABSTRACT

The paper describes a system and experimental procedure that use integrating passive detectors, such as thermoluminescent dosimeters (TLDs), for the measurement of ultra-low-level ambient dose equivalent rate values at the underground SNOLAB facility located in Sudbury, Ontario, Canada. Because these detectors are passive and can be exposed for relatively long periods of time, they can provide better sensitivity for measuring ultra-low activity levels. The final characterization of ultra-low-level ambient dose around water shielding for ongoing direct dark matter search experiments in Cube Hall at SNOLAB underground laboratory is given. The conclusion is that TLDs provide reliable results in the measurement of the ultra-low-level environmental radiation background.

2.
Sensors (Basel) ; 20(20)2020 Oct 10.
Article in English | MEDLINE | ID: mdl-33050397

ABSTRACT

This paper explores the prospect of CMOS devices to assay lead in drinking water, using calorimetry. Lead occurs together with traces of radioisotopes, e.g., 210Pb, producing g-emissions with energies ranging from 10 keV to several 100 keV when they decay; this range is detectable in silicon sensors. In this paper we test a CMOS camera (OXFORD INSTRUMENTS Neo 5.5) for its general performance as a detector of X-rays and low energy g-rays and assess its sensitivity relative to the World Health Organization upper limit on lead in drinking water. Energies from 6 keV to 60 keV are examined. The CMOS camera has a linear energy response over this range and its energy resolution is for the most part slightly better than 2%. The Neo sCMOS is not sensitive to X-rays with energies below ~10 keV. The smallest detectable rate is 40 ± 3 mHz, corresponding to an incident activity on the chip of 7 ± 4 Bq. The estimation of the incident activity sensitivity from the detected activity relies on geometric acceptance and the measured efficiency vs. energy. We report the efficiency measurement, which is 0.08(2)% (0.0011(2)%) at 26.3 keV (59.5 keV). Taking calorimetric information into account we measure a minimal detectable rate of 4 ± 1 mHz (1.5 ± 0.1 mHz) for 26.3 keV (59.5 keV) g-rays, which corresponds to an incident activity of 1.0 ± 0.6 Bq (57 ± 33 Bq). Toy Monte Carlo and Geant4 simulations agree with these results. These results show this CMOS sensor is well-suited as a g- and X-ray detector with sensitivity at the few to 100 ppb level for 210Pb in a sample.

SELECTION OF CITATIONS
SEARCH DETAIL
...