Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Eur J Radiol ; 175: 111426, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38493558

ABSTRACT

PURPOSE: We aimed to identify the optimal reconstruction settings based on qualitative and quantitative image quality parameters on standard and ultra-high resolution (UHR) images using photon-counting CT (PCCT). METHOD: We analysed 45 patients, 29 with standard and 16 with UHR acquisition, applying both smoother and sharper kernel settings. Coronary CT angiography images were performed on a dual-source PCCT system using standard (0.4/0.6 mm slice thickness, Bv40/Bv44 kernels, QIR levels 0-4) or UHR acquisition (0.2/0.4 mm slice thickness, Bv44/Bv56 kernels, QIR levels 0-4). Qualitative image quality was assessed using a 4-point Likert scale. Image noise (SD), signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated in both the proximal and distal segments. RESULTS: On standard resolution, larger slice thickness resulted in an average increase of 12.5 % in CNR, whereas sharper kernel led to an average 8.7 % decrease in CNR. Highest CNR was measured on 0.6 mm, Bv40, QIR4 images and lowest on 0.4 mm, Bv44, QIR0 images: 25.8 ± 4.1vs.8.3 ± 1.6 (p < 0.001). On UHR images, highest CNR was observed on 0.4 mm, Bv40, QIR4 and lowest on 0.2 mm, Bv56 and QIR0 images: 21.5 ± 3.9vs.3.6 ± 0.8 (p < 0.001). Highest qualitative image quality was found on images with Bv44 kernel and QIR level 3/4 with both slice thicknesses on standard reconstruction. Additionally, Bv56 with QIR4 on 0.2 mm slice thickness images showed highest subjective image quality. Preserved distal vessel visualization was detected using QIR 2-4, Bv56 and 0.2 mm slice thickness. CONCLUSIONS: Photon-counting CT demonstrated high qualitative and quantitative image quality for the assessment of coronaries and stents.


Subject(s)
Computed Tomography Angiography , Coronary Angiography , Photons , Humans , Computed Tomography Angiography/methods , Coronary Angiography/methods , Female , Male , Middle Aged , Aged , Radiographic Image Interpretation, Computer-Assisted/methods , Signal-To-Noise Ratio , Coronary Artery Disease/diagnostic imaging , Reproducibility of Results , Adult
2.
J Cardiovasc Comput Tomogr ; 18(1): 69-74, 2024.
Article in English | MEDLINE | ID: mdl-38097408

ABSTRACT

BACKGROUND: We sought to compare the degree of maximal stenosis and the rate of invasive coronary angiography (ICA) recommendations in patients who underwent coronary CT angiography (CCTA) with photon-counting detector CT (PCD-CT) versus those who underwent CCTA with whole heart coverage energy-integrating detector CT (EID-CT). METHODS: In our retrospective single-center study, we included consecutive patients with suspected CAD who underwent CCTA performed with either PCD-CT or a 280-slice EID-CT. The degree of coronary stenosis was classified as no CAD, minimal (1-24 â€‹%), mild (25-49 â€‹%), moderate (50-69 â€‹%), severe stenosis (70-99 â€‹%), or occlusion. RESULTS: A total of 812 consecutive patients were included in the analysis, 401 patients scanned with EID-CT and 411 patients with PCD-CT (mean age: 58.4 â€‹± â€‹12.4 years, 45.4 â€‹% female). Despite the higher total coronary artery calcium score (CACS) in the PCD-CT group (10 [interquartile range (IQR) â€‹= â€‹0-152.8] vs 1 [IQR â€‹= â€‹0-94], p â€‹< â€‹0.001), obstructive CAD was more frequently reported in the EID-CT vs PCD-CT group (no CAD: 28.7 â€‹% vs 26.0 â€‹%, minimal: 23.2 â€‹% vs 30.9 â€‹%, mild: 19.7 â€‹% vs 23.4 â€‹%, moderate: 14.5 â€‹% vs 9.7 â€‹%, severe: 11.5 â€‹% vs 8.5 â€‹% and occlusion: 2.5 â€‹% vs 1.5 â€‹%, respectively, p â€‹= â€‹0.025). EID-CT was independently associated with downstream ICA (OR â€‹= â€‹2.76 [95%CI â€‹= â€‹1.58-4.97] p â€‹< â€‹0.001) in the overall patient population, in patients with CACS<400 (OR â€‹= â€‹2.18 [95%CI â€‹= â€‹1.13-4.39] p â€‹= â€‹0.024) and in patients with CACS≥400 (OR â€‹= â€‹3.83 [95%CI â€‹= â€‹1.42-11.05] p â€‹= â€‹0.010). CONCLUSION: In patients who underwent CCTA with PCD-CT the number of subsequent ICAs was lower as compared to patients who were scanned with EID-CT. This difference was greater in patients with extensive coronary calcification.


Subject(s)
Computed Tomography Angiography , Tomography, X-Ray Computed , Humans , Female , Middle Aged , Aged , Male , Coronary Angiography , Retrospective Studies , Constriction, Pathologic , Prospective Studies , Predictive Value of Tests , Referral and Consultation , Phantoms, Imaging
3.
J Cardiovasc Dev Dis ; 10(6)2023 Jun 13.
Article in English | MEDLINE | ID: mdl-37367422

ABSTRACT

(1) Study purpose: The aim of our prospective single-center, matched case-control study was to compare the number and volume of acute ischemic brain lesions following carotid endarterectomy (CEA) versus carotid artery stenting (CAS) using a propensity-matched design. (2) Methods: Carotid bifurcation plaques were analyzed by using VascuCAP software on CT angiography (CTA) images. The number and volume of acute and chronic ischemic brain lesions were assessed on MRI scans taken 12-48 h after the procedures. Propensity score-based matching was performed at a 1:1 ratio to compare the ischemic lesions on postinterventional MR. (3) Results: A total of 107 patients (CAS, N = 33; CEA, N = 74) were included in the study. There were significant differences in smoking (p = 0.003), total calcification plaque volume (p = 0.004), and lengths of the lesion (p = 0.045) between the CAS and CEA groups. Propensity score matching resulted in 21 matched pairs of patients. Acute ischemic brain lesions were detected in ten patients (47.6%) of the matched CAS group and in three patients (14.2%) in the matched CEA group (p = 0.02). The volume of acute ischemic brain lesions was significantly larger (p = 0.04) in the CAS group than in the CEA group. New ischemic brain lesions were not associated with neurological symptoms in either group. (4) Conclusions: Procedure-related new acute ischemic brain lesions occurred significantly more frequently in the propensity-matched CAS group.

4.
Psychol Med ; 53(4): 1355-1363, 2023 03.
Article in English | MEDLINE | ID: mdl-34334146

ABSTRACT

BACKGROUND: Our study examined whether the early-onset depression phenotype among young adults (probands) is associated with the metabolic syndrome (MetS) and its components, and if MetS characterizes unaffected but high-risk siblings of probands. METHODS: We studied three groups of young adults (Mage = 25 years, s.d. = 3.84 years): probands with histories of childhood onset depression - i.e. early-onset phenotype - (n = 293), their unaffected siblings (high-risk siblings, n = 273), and healthy controls (n = 171). Participants completed a full psychiatric interview, physical and laboratory assessments, and self-rating scales. MetS was defined using the criteria of the Expert Panel on Detection, Evaluation, and Treatment of High Blood Cholesterol in Adults (). RESULTS: Early-onset depression phenotype and being a high-risk sibling were associated with higher MetS composite scores relative to that of controls, but did not differ from one another. With regard to MetS components: Probands and siblings had similarly larger waist circumference and lower HDL than did controls, while siblings and controls had lower triglyceride levels than did probands but did not differ from one another. Groups did not differ on glucose levels and SBP. CONCLUSIONS: Our study extends the literature on the association between MetS and depression and underscores the importance of depression phenotypes: failure to account for the clinical heterogeneity of depression may partly underlie the inconsistent findings regarding its relation to MetS. The results also suggest that, in depression-prone populations, MetS may predate and possibly function as a risk factor for eventual depression.


Subject(s)
Metabolic Syndrome , Humans , Metabolic Syndrome/epidemiology , Metabolic Syndrome/genetics , Depression/epidemiology , Genetic Predisposition to Disease , Risk Factors , Phenotype
5.
Vasc Endovascular Surg ; 55(4): 374-381, 2021 May.
Article in English | MEDLINE | ID: mdl-33563130

ABSTRACT

PURPOSE: We aimed to examine the effectiveness of different therapeutic options for and to identify the possible risk factors of recurrent internal carotid artery (ICA) in-stent restenosis (ISR). METHODS: Forty-six ICA ISRs, which were reintervened at least once, were retrospectively analyzed regarding clinical and imaging characteristics, as well as invasive treatment type (percutaneous transluminal angioplasty [PTA] with a plain balloon, PTA with a drug-eluting balloon [DEB], re-stenting) used. RESULTS: The median follow-up was 29.5 months (IQR, 8.5-52.8 months) in patients who underwent reintervention for ICA ISR. Stent occlusion occurred in 3 patients (6.5%). One ISR recurrence was noted in 10 patients (21.7%); reintervention was carried out in 7 cases (7/10 [70%]; PTA, N = 5; PTA with a DEB, N = 1; re-stenting, N = 1), while 3 patients (3/10; 30%) received best medical treatment. Two ISR recurrences were observed in 3 patients (6.5%); all of them underwent reintervention (PTA, N = 1; PTA with a DEB, N = 2). Three ISR recurrences were seen in 1 patient (2.2%), who was treated with PTA. No recurrence was observed in those patients, who had DEB treatment. Multiple logistic regression analysis revealed statin therapy to be a protective factor against recurrent ISR (OR, 0.17; 95% CI, 0.03-0.84; P = .029). CONCLUSION: Our study suggests that PTA with a DEB is the most effective for the treatment of recurrent ISR, and confirms the importance of statin use in patients who have had a carotid reintervention.


Subject(s)
Angioplasty, Balloon , Carotid Artery, Internal , Carotid Stenosis/therapy , Endovascular Procedures/instrumentation , Hydroxymethylglutaryl-CoA Reductase Inhibitors/therapeutic use , Stents , Aged , Angioplasty, Balloon/adverse effects , Carotid Artery, Internal/diagnostic imaging , Carotid Artery, Internal/physiopathology , Carotid Stenosis/diagnostic imaging , Carotid Stenosis/physiopathology , Endovascular Procedures/adverse effects , Female , Humans , Hydroxymethylglutaryl-CoA Reductase Inhibitors/adverse effects , Male , Middle Aged , Protective Factors , Recurrence , Retreatment , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome
6.
J Vasc Surg ; 73(2): 510-515.e2, 2021 02.
Article in English | MEDLINE | ID: mdl-32447038

ABSTRACT

OBJECTIVE: The purpose of this study was to report our results of patients' characteristics, procedural complications, and long-term patency in treatment of isolated infrarenal aortic stenosis (IIAS). METHODS: Forty symptomatic patients (28 female, 12 male; median age, 60 years [54.8-68 years]) with IIAS who underwent endovascular intervention between 2001 and 2017 were retrospectively analyzed. Patient, lesion, procedure, and balloon/stent characteristics were assessed. Follow-up included clinical status evaluation and color Doppler ultrasound examination. RESULTS: The cause of IIAS was atherosclerosis in all patients. Twenty percent of the patients were younger than 50 years; 85% had hypertension, 80% were smokers, 38% had hyperlipidemia, 23% had diabetes mellitus, 15% were obese (body mass index ≥30 kg/m2), and 8% had chronic kidney disease. The median stenosis grade was 80% (70%-80%), and the median lesion length was 19.9 mm (13-29.4 mm). Severe calcification was present in 8% of the patients. Percutaneous transluminal angioplasty was performed in four cases (10%), whereas stenting was performed in 36 (90%). One complication, an aortic rupture requiring surgical repair, occurred. The median follow-up was 61 months (17-101 months). The primary patency rate was 100% at 6 months, 97% at 12 and 24 months, and 88% at 60 and 96 months. Restenosis developed in three patients (8%); reintervention was carried out in two cases (5%). CONCLUSIONS: Endovascular therapy for IIAS provides a safe and effective long-term treatment strategy.


Subject(s)
Angioplasty, Balloon , Aortic Diseases/therapy , Atherosclerosis/therapy , Aged , Angioplasty, Balloon/adverse effects , Angioplasty, Balloon/instrumentation , Aorta, Abdominal/diagnostic imaging , Aorta, Abdominal/physiopathology , Aortic Diseases/diagnostic imaging , Aortic Diseases/physiopathology , Atherosclerosis/diagnostic imaging , Atherosclerosis/physiopathology , Constriction, Pathologic , Female , Humans , Male , Middle Aged , Recurrence , Retreatment , Retrospective Studies , Risk Assessment , Risk Factors , Stents , Time Factors , Treatment Outcome , Vascular Patency
7.
Cardiovasc Intervent Radiol ; 43(8): 1134-1142, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32440962

ABSTRACT

PURPOSE: In the absence of literature data, we aimed to determine the long-term patency rates of middle/distal common carotid artery (CCA) stenting and to investigate predisposing factors in the development of in-stent restenosis (ISR). MATERIALS AND METHODS: Fifty-one patients (30 males, median age 63.5 years), who underwent stenting with 51 self-expandable stents for significant (≥ 60%) stenosis of the middle/distal CCA, were analyzed retrospectively. Patient (atherosclerotic risk factors, comorbidities, medications), vessel (elongation), lesion (stenosis grade, length, calcification, location), and stent characteristics (material, diameter, length, fracture) were examined. Duplex ultrasonography was used to monitor stent patency. The Mann-Whitney U and Fisher's exact tests, Kaplan-Meier analyses, and a log-rank test were used statistically. RESULTS: The median follow-up time was 35 months (interquartile range, 20-102 months). Significant (≥ 70%) ISR developed in 14 patients (27.5%; stenosis, N = 10; entire CCA occlusion, N = 4). Primary patency rates were 98%, 92%, 83%, 73%, and 61% at 6, 12, 24, 60, and 96 months, respectively. Reintervention was performed in six patients (11.8%) with nonocclusive ISR. Secondary patency rates were 100% at 6 and 12 months and 96% at 24, 60, and 96 months. In-stent restenosis developed more frequently (P < .001) in patients with hyperlipidemia; primary patency rates were also significantly worse (Chi-square, 11.08; degrees of freedom, 1; P < .001) in patients with hyperlipidemia compared to those without. CONCLUSION: Stenting of the middle/distal CCA can be performed with acceptable patency rates. If intervention is unequivocally needed, patients with hyperlipidemia will require closer follow-up care. LEVEL OF EVIDENCE: Level 3, Local non-random sample.


Subject(s)
Arterial Occlusive Diseases/epidemiology , Carotid Artery, Common/surgery , Stents , Vascular Patency , Aged , Arterial Occlusive Diseases/diagnostic imaging , Arterial Occlusive Diseases/pathology , Carotid Artery, Common/diagnostic imaging , Carotid Artery, Common/pathology , Constriction, Pathologic , Diagnostic Imaging/methods , Female , Follow-Up Studies , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Recurrence , Retrospective Studies , Risk Assessment , Risk Factors , Treatment Outcome
8.
J Vasc Surg ; 71(3): 824-831.e1, 2020 03.
Article in English | MEDLINE | ID: mdl-31405760

ABSTRACT

OBJECTIVE: Our aim was to identify the incidence of and predictors for common carotid artery (CCA) stent fractures (SFs) and to examine the effect of SFs on the development of in-stent restenosis (ISR). METHODS: Seventy patients (37 women; median age, 60.9 years) who were stented for significant (≥60%) proximal CCA stenosis from 2006 to 2016 and revisited us to determine SF using fluoroscopy in 2018 were evaluated. Seventy stents were deployed; among them 87.1% were balloon-expandable and 12.9% were self-expandable. SFs were classified as type I (fracture of one strut), type II (fracture of multiple struts without stent deformity), type III (fracture of multiple struts with stent deformity), type IV (complete fracture of the stent without a gap), and type V (complete fracture of the stent with a gap). Duplex ultrasound examination was used for monitoring stent patency. Mann-Whitney U and Fisher's exact tests, Kaplan-Meier and logistic regression analyses, and a log-rank test and a gamma correlation analysis were applied as statistical methods. RESULTS: The patients were followed for 75.5 months (range, 47-109 months). Significant (≥70%) ISR was observed in eight patients (11.4%). Reintervention was performed in four cases (5.7%). Twenty-seven SFs (38.6%; type I, 8; type II, 10; type III, 4; type IV, 2; and type V, 3) were found. Calcification was shown to be a significant predictor for SF (odds ratio, 13.2; 95% confidence interval, 3.9-45.1; P < .001). There was no significant difference between the fractured and the nonfractured group regarding the number of patients with ISR and reintervention (P = .701 and P = .636, respectively). Neither did the primary patency rates differ significantly (P = .372) in patients with and without SF. CONCLUSIONS: Fractures frequently occur in a wide variety of stent devices deployed in the proximal CCA, but SFs seem to have no effect on ISR and reintervention.


Subject(s)
Carotid Stenosis/therapy , Prosthesis Failure , Stents , Aged , Carotid Stenosis/diagnostic imaging , Female , Fluoroscopy , Humans , Incidence , Male , Middle Aged , Retrospective Studies , Risk Factors , Ultrasonography, Doppler, Duplex
9.
J Vasc Surg ; 70(4): 1146-1154.e1, 2019 10.
Article in English | MEDLINE | ID: mdl-30926275

ABSTRACT

OBJECTIVE: To determine the prevalence and risk factors of subclavian artery stent fractures and to investigate their impact on in-stent restenosis development. METHODS: One hundred eight patients (65 females; median age, 58.3 years [interquartile range, 53.4-65.5 years]) with steno-occlusive disease of the first part of the subclavian artery who underwent stenting (N = 108 stents; balloon-expandable, 83.3%; self-expandable, 16.7%) between 2005 and 2015 and returned for a fluoroscopic examination of the implanted stents in 2017 were included in our study. Fractures were type I (single strut fracture), type II (multiple strut fractures without deformation), type III (multiple strut fractures with deformation), type IV (multiple strut fractures with acquired transection but without gap), or type V (multiple strut fractures with acquired transection with gap in the stent body). Stent patency was monitored by duplex ultrasound imaging. The Mann-Whitney U and Fisher's exact tests; Kaplan-Meier, receiver operating characteristic, and logistic regression analyses; as well as a log-rank test were used as statistical methods. RESULTS: The median follow-up was 73.8 months (interquartile range, 35.6-104.2 months). Thirty-eight fractures (35.2%) were detected; fractures were type I in 13, type II in 12, type III in 6, type IV in 4, and type V in 3 cases. Multivariable logistic regression analysis revealed the presence of long (≥20 mm) lesions (odds ratio, 3.3; 95% confidence interval, 1.3-8.4; P = .012) and heavy calcification (odds ratio, 4.7; 95% confidence interval, 1.7-12.7; P = .002) to be significant independent predictors of stent fracture. The primary patency rates were significantly worse (P = .035) in patients with stent fracture compared with those without stent fracture. CONCLUSIONS: Stent fractures frequently occur. Patients with long and/or heavily calcified lesions require closer follow-up.


Subject(s)
Angioplasty, Balloon/instrumentation , Prosthesis Failure , Stents , Subclavian Steal Syndrome/therapy , Vascular Calcification/therapy , Aged , Angioplasty, Balloon/adverse effects , Female , Humans , Male , Middle Aged , Prospective Studies , Prosthesis Design , Recurrence , Retrospective Studies , Risk Assessment , Risk Factors , Severity of Illness Index , Subclavian Steal Syndrome/diagnostic imaging , Subclavian Steal Syndrome/physiopathology , Time Factors , Treatment Outcome , Vascular Calcification/diagnostic imaging , Vascular Calcification/physiopathology , Vascular Patency
10.
J Endovasc Ther ; 25(5): 632-639, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30122138

ABSTRACT

PURPOSE: To determine the long-term patency of aortoiliac kissing stents and to identify predisposing factors for the development of in-stent restenosis (ISR). METHODS: A retrospective analysis was conducted of 105 patients (median age 60.9 years; 64 women) with symptomatic aortoiliac occlusive disease who had kissing stents implanted between 2001 and 2015. The indication for kissing stents was severe claudication in 91 (86.7%) patients and critical limb ischemia in 14 (13.3%). Lesions were TASC A in 52 (49.5%), B in 29 (27.6%), C in 4 (3.8%), and D in 20 (19%) patients. Twenty-five (23.8%) patients had heavily calcified lesions. In all, 210 stents were deployed [180 (85.7%) self-expanding and 30 (14.3%) balloon-expandable]. Follow-up included clinical evaluation, ankle-brachial index measurement, and duplex ultrasonography. RESULTS: The median follow-up was 45 months. The primary patency rates were 93%, 86%, and 77% at 12, 24, and 60 months, respectively. Significant ISR developed in 23 (21.9%) patients (12 unilateral and 11 bilateral). Univariate Cox regression analysis revealed older age [hazard ratio (HR) 0.5, 95% confidence interval (CI) 0.31 to 0.81, p=0.004] and larger aortic diameter (HR 0.42, 95% CI 0.25 to 0.7, p<0.001) to be variables favoring long-term patency, while a longer aortic stent segment (HR 1.56, 95% CI 1.16 to 2.09, p=0.003) and a larger discrepancy between the summed stent diameters and the aortic diameter (HR 1.64, 95% CI 1.01 to 2.65, p=0.043) were associated with ISR development. Multivariate analysis showed a longer aortic stent segment to be the only significant determinant of ISR (HR 1.44, 95% CI 1.02 to 2.01, p=0.035). CONCLUSION: The kissing stent technique can be performed with good long-term patency. Patients whose iliac stents protrude too far into the aorta need closer follow-up.


Subject(s)
Angioplasty, Balloon/adverse effects , Angioplasty, Balloon/instrumentation , Aortic Diseases/therapy , Arterial Occlusive Diseases/therapy , Iliac Artery , Intermittent Claudication/therapy , Ischemia/therapy , Stents , Aged , Aortic Diseases/diagnostic imaging , Aortic Diseases/physiopathology , Arterial Occlusive Diseases/diagnostic imaging , Arterial Occlusive Diseases/physiopathology , Critical Illness , Female , Humans , Iliac Artery/diagnostic imaging , Iliac Artery/physiopathology , Intermittent Claudication/diagnostic imaging , Intermittent Claudication/physiopathology , Ischemia/diagnostic imaging , Ischemia/physiopathology , Male , Middle Aged , Prosthesis Design , Retrospective Studies , Time Factors , Treatment Outcome , Vascular Patency
SELECTION OF CITATIONS
SEARCH DETAIL
...