1.
J Card Fail ; 29(11): 1522-1530, 2023 11.
Article in English | MEDLINE | ID: mdl-37220824

ABSTRACT

BACKGROUND: The implantable cardiac defibrillator-based HeartLogic algorithm aims to detect impending fluid retention in patients with heart failure (HF). Studies show that HeartLogic is safe to integrate into clinical practice. The current study investigates whether HeartLogic provides clinical benefit on top of standard care and device telemonitoring in patients with HF. METHODS: A multicenter, retrospective, propensity-matched cohort analysis was performed in patients with HF and implantable cardiac defibrillators, and it compared HeartLogic to conventional telemonitoring. The primary endpoint was the number of worsening HF events. Hospitalizations and ambulatory visits due to HF were also evaluated. RESULTS: Propensity score matching yielded 127 pairs (median age 68 years, 80% male). Worsening HF events occurred more frequently in the control group (2; IQR 0-4) compared to the HeartLogic group (1; IQR 0-3; P = 0.004). The number of HF hospitalization days was higher in controls than in the HeartLogic group (8; IQR 5-12 vs 5; IQR 2-7; P = 0.023), and ambulatory visits for diuretic escalation were more frequent in the control group than in the HeartLogic group (2; IQR 0-3 vs 1; IQR 0-2; P = 0.0001). CONCLUSION: Integrating the HeartLogic algorithm in a well-equipped HF care path on top of standard care is associated with fewer worsening HF events and shorter duration of fluid retention-related hospitalizations.


Subject(s)
Defibrillators, Implantable , Heart Failure , Humans , Male , Aged , Female , Retrospective Studies , Heart Failure/diagnosis , Heart Failure/epidemiology , Heart Failure/therapy , Cohort Studies , Hospitalization
2.
JACC Case Rep ; 4(7): 438-442, 2022 Apr 06.
Article in English | MEDLINE | ID: mdl-35693896

ABSTRACT

We describe the case of a young woman with a dual-chamber implantable cardioverter-defibrillator for long-QT syndrome who was referred to our emergency department (Cardiovascular Research Centre of Aalst, Belgium) because of an "arrhythmic storm" caused by atrial lead fracture. This case highlights the importance of the correct choice of both the device type and the pacing modality. (Level of Difficulty: Intermediate.).

4.
Pacing Clin Electrophysiol ; 44(5): 943-951, 2021 May.
Article in English | MEDLINE | ID: mdl-33829506

ABSTRACT

BACKGROUND: Exercise capacity is an important aspect of quality of life in patients undergoing pacemaker implantation. Device algorithms for ventricular pacing avoidance have been developed to avoid unnecessary and potentially harmful effects of right ventricular pacing. However, little data exists on the immediate response of these algorithms to sudden AV block during exercise. METHODS: The ventricular pacing avoidance algorithms of four pacemaker manufacturers were tested in an ex-vivo model. The RSIM-1500-USB Device-Interactive Heart Simulator (Rivertek Medical Systems, Inc.) was used to simulate three different scenarios: the first one starting with an initially conducted atrial pacing rate of 60 min-1 , the second one starting with an atrial rate of 120 min-1 and finally a scenario starting with an atrial rate of 150 min-1 . In all three scenarios, the initially conducted atrial rate was followed by a sudden, long lasting episode of third-degree AV-block. The response to those scenarios was recorded for each of the (brand-specific) ventricular pacing avoidance algorithms. RESULTS: In the first scenario, the simulation resulted in a ventricular pause of 1333 ms (Boston Scientific), 2000 ms (Medtronic and Microport), and 2340 ms (Biotronik). In the second and third scenario, different results were observed across devices. All simulations of the second and third scenario resulted in repetitive 2:1 block response (during eight cycles) in Boston Scientific and Biotronik devices. These scenarios were confirmed in patient cases. CONCLUSION: Simulator based observations of unanticipated pacemaker-induced 2:1 block response during exercise may explain clinical symptoms experienced by some patients having a two-chamber pacemaker.


Subject(s)
Algorithms , Atrioventricular Node/physiopathology , Exercise Tolerance , Heart Block/physiopathology , Pacemaker, Artificial , Electrocardiography , Humans , Quality of Life
5.
ESC Heart Fail ; 8(2): 1541-1551, 2021 04.
Article in English | MEDLINE | ID: mdl-33619901

ABSTRACT

AIMS: The implantable cardiac defibrillator/cardiac resynchronization therapy with defibrillator-based HeartLogic™ algorithm has recently been developed for early detection of impending decompensation in heart failure (HF) patients; but whether this novel algorithm can reduce HF hospitalizations has not been evaluated. We investigated if activation of the HeartLogic algorithm reduces the number of hospital admissions for decompensated HF in a 1 year post-activation period as compared with a 1 year pre-activation period. METHODS AND RESULTS: Heart failure patients with an implantable cardiac defibrillator/cardiac resynchronization therapy with defibrillator with the ability to activate HeartLogic and willingness to have remote device monitoring were included in this multicentre non-blinded single-arm trial with historical comparison. After a HeartLogic alert, the presence of HF symptoms and signs was evaluated. If there were two or more symptoms and signs apart from the HeartLogic alert, lifestyle advices were given and/or medication was adjusted. After activation of the algorithm, patients were followed for 1 year. HF events occurring in the 1 year prior to activation and in the 1 year after activation were compared. Of the 74 eligible patients (67.2 ± 10.3 years, 84% male), 68 patients completed the 1 year follow-up period. The total number of HF hospitalizations reduced from 27 in the pre-activation period to 7 in the post-activation period (P = 0.003). The number of patients hospitalized for HF declined from 21 to 7 (P = 0.005), and the hospitalization length of stay diminished from average 16 to 7 days (P = 0.079). Subgroup analysis showed similar results (P = 0.888) for patients receiving cardiac resynchronization therapy during the pre-activation period or not receiving cardiac resynchronization therapy, meaning that the effect of hospitalizations cannot solely be attributed to reverse remodelling. Subanalysis of a single-centre Belgian subpopulation showed important reductions in overall health economic costs (P = 0.025). CONCLUSION: Activation of the HeartLogic algorithm enables remote monitoring of HF patients, coincides with a significant reduction in hospitalizations for decompensated HF, and results in health economic benefits.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Algorithms , Female , Heart Failure/epidemiology , Heart Failure/therapy , Hospitalization , Humans , Male