1.
JACC Cardiovasc Interv ; 17(13): 1597-1606, 2024 Jul 08.
Article in English | MEDLINE | ID: mdl-38986659

ABSTRACT

BACKGROUND: Severe pure aortic regurgitation (AR) carries a high mortality and morbidity risk, and it is often undertreated because of the inherent surgical risk. Transcatheter heart valves (THVs) have been used off-label in this setting with overall suboptimal results. The dedicated "purpose-built" Jena Valve Trilogy (JVT, JenaValve Technology) showed an encouraging performance, although it has never been compared to other THVs. OBJECTIVES: The aim of our study was to assess the performance of the latest iteration of THVs used off-label in comparison to the purpose-built JVT in inoperable patients with severe AR. METHODS: We performed a multicenter, retrospective registry with 18 participating centers worldwide collecting data on inoperable patients with severe AR of the native valve. A bicuspid aortic valve was the main exclusion criterion. The primary endpoints were technical and device success, 1-year all-cause mortality, and the composite of 1-year mortality and the heart failure rehospitalization rate. RESULTS: Overall, 256 patients were enrolled. THVs used off-label were used in 168 cases (66%), whereas JVT was used in 88 (34%). JVT had higher technical (81% vs 98%; P < 0.001) and device success rates (73% vs 95%; P < 0.001), primarily driven by significantly lower incidences of THV embolization (15% vs 1.1%; P < 0.001), the need for a second valve (11% vs 1.1%; P = 0.004), and moderate residual AR (10% vs 1.1%; P = 0.007). The permanent pacemaker implantation rate was comparable and elevated for both groups (22% vs 24%; P = 0.70). Finally, no significant difference was observed at the 1-year follow-up in terms of mortality (HR: 0.99; P = 0.980) and the composite endpoint (HR: 1.5; P = 0.355). CONCLUSIONS: The JVT platform has a better acute performance than other THVs when used off-label for inoperable patients with severe AR. A longer follow-up is conceivably needed to detect a possible impact on prognosis.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve , Heart Valve Prosthesis , Prosthesis Design , Registries , Severity of Illness Index , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve Insufficiency/physiopathology , Aortic Valve Insufficiency/mortality , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Female , Male , Retrospective Studies , Aged , Treatment Outcome , Aged, 80 and over , Risk Factors , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/instrumentation , Patient Readmission , Recovery of Function , Europe , Heart Failure/mortality , Heart Failure/therapy , Heart Failure/physiopathology , Heart Failure/diagnosis , Hemodynamics
2.
JAMA Cardiol ; 2024 Jul 10.
Article in English | MEDLINE | ID: mdl-38985461

ABSTRACT

Importance: In older patients with atrial fibrillation who take anticoagulants for stroke prevention, bleeding is increased compared with younger patients, thus, clinicians frequently prescribe lower than recommended doses in older patients despite limited randomized data. Objective: To evaluate ischemic and bleeding outcomes in patients 80 years and older with atrial fibrillation receiving edoxaban, 60 mg vs 30 mg, and edoxaban, 30 mg vs warfarin. Design, Setting, and Participants: The ENGAGE AF-TIMI 48 trial (Effective Anticoagulation With Factor Xa Next Generation in Atrial Fibrillation-Thrombolysis in Myocardial Infarction 48) was a parallel-design, double-blind, global clinical trial that randomized patients with atrial fibrillation to either one of 2 edoxaban dosing regimens or warfarin. This secondary analysis focused on patients 80 years or older without dose-reduction criteria receiving edoxaban, 60 mg vs 30 mg, as well as patients with or without dose-reduction criteria receiving edoxaban, 30 mg, vs warfarin. Study data were analyzed between October 2022 and December 2023. Interventions: Oral edoxaban, 30 mg once daily; edoxaban, 60 mg once daily; or warfarin. Main Outcomes and Measures: Primary net clinical outcome of death, stroke or systemic embolism, and major bleeding and each individual component. Results: The current analysis included 2966 patients 80 years and older (mean [SD] age, 83 [2.7] years; 1671 male [56%]). Among 1138 patients 80 years and older without dose-reduction criteria, those receiving edoxaban, 60 mg vs 30 mg, had more major bleeding events (hazard ratio [HR], 1.57; 95% CI, 1.04-2.38; P = .03), particularly gastrointestinal hemorrhage (HR, 2.24; 95% CI, 1.29-3.90; P = .004), with no significant difference in efficacy end points. Findings were supported by analyses of endogenous factor Xa inhibition, a marker of anticoagulant effect, which was comparable between younger patients receiving edoxaban, 60 mg, and older patients receiving edoxaban, 30 mg. In 2406 patients 80 years and older with or without dose-reduction criteria, patients receiving edoxaban, 30 mg, vs warfarin had lower rates of the primary net clinical outcome (HR, 0.78; 95% CI, 0.68-0.91; P = .001), major bleeding (HR, 0.59; 95% CI, 0.45-0.77; P < .001), and death (HR, 0.83; 95% CI, 0.70-1.00; P = .046), whereas rates of stroke or systemic embolism were comparable. Conclusions and Relevance: In this post hoc analysis of the ENGAGE AF-TIMI 48 randomized clinical trial, in patients 80 years and older with atrial fibrillation, major bleeding events were lower in patients randomized to receive edoxaban, 30 mg per day, compared with either edoxaban, 60 mg per day (in patients without dose-reduction criteria), or warfarin (irrespective of dose-reduction status), without an offsetting increase in ischemic events. These data support the concept that lower-dose anticoagulants, such as edoxaban, 30 mg, may be considered in older patients with atrial fibrillation even in the absence of dose-reduction criteria. Trial Registration: ClinicalTrials.gov Identifier: NCT00781391.

3.
Article in English | MEDLINE | ID: mdl-38970592

ABSTRACT

Inter-echocardiography core laboratory (ECL) harmonization is pivotal to consider data from different ECLs interchangeable. On the basis of the experience of the first trans-Atlantic harmonization of 2 established ECLs in the field of transcatheter aortic valve replacement (TAVR) trials, this review describes the harmonized ECL methodology in analyzing and adjudicating the post-TAVR echocardiographic endpoints according to Valve Academic Research Consortium 3 definitions. This review presents the feasibility and intra- and inter-ECL reproducibility, explains the root cause of potential important inter-ECL variability, and formulates ECL recommendations for optimal post-TAVR echocardiographic image acquisition. The implementation of inter-ECL harmonization may further define the best practice of ECLs and have logistic and regulatory implications for the realization of future TAVR trials.

4.
Article in English | MEDLINE | ID: mdl-38970594

ABSTRACT

3-dimensional (3D) intracardiac echocardiography (ICE) is emerging as a promising complement and potential alternative to transesophageal echocardiography for imaging guidance in structural heart interventions. To establish standardized practices, our multidisciplinary expert position statement serves as a comprehensive guide for the appropriate indications and utilization of 3D-ICE in various structural heart procedures. The paper covers essential aspects such as the fundamentals of 3D-ICE imaging, basic views, and workflow recommendations specifically tailored for ICE-guided structural heart procedures, such as transeptal puncture, device closure of intracardiac structures, and transcatheter mitral and tricuspid valve interventions. Current challenges, future directions, and training requirements to ensure operator proficiency are also discussed, thereby promoting the safety and efficacy of this innovative imaging modality to support expanding its future clinical applications.

5.
J Clin Med ; 13(11)2024 May 25.
Article in English | MEDLINE | ID: mdl-38892807

ABSTRACT

Atherosclerosis is the predominant underlying etiopathology of coronary artery disease. Changes in plaque phenotype from stable to high risk may spur future major adverse cardiac events (MACE). Different pharmacological therapies have been implemented to mitigate this risk. Over the last two decades, intravascular imaging modalities have emerged in clinical studies to clarify how these therapies may affect the composition and burden of coronary plaques. Lipid-lowering agents, such as statins, ezetimibe, and proprotein convertase subtilisin/kexin type 9 inhibitors, were shown not only to reduce low-density lipoprotein levels and MACE but also to directly affect features of coronary plaque vulnerability. Studies have demonstrated that lipid-lowering therapy reduces the percentage of atheroma volume and number of macrophages and increases fibrous cap thickness. Future studies should answer the question of whether pharmacological plaque stabilization may be sufficient to mitigate the risk of MACE for selected groups of patients with atherosclerotic coronary disease.

6.
Eur Heart J Case Rep ; 8(6): ytae291, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38938469

ABSTRACT

Background: Left ventricular assist devices (LVADs) are increasingly utilized in cardiogenic shock and high-risk percutaneous coronary interventions (PCIs). These devices aspirate and expel blood from the left ventricle (LV) into the aorta, consequently reducing left ventricular end-diastolic pressure (LVEDP). We report a case of unexpected LVEDP rise under LV-to-aorta LVAD in the context of transcatheter aortic valve implantation (TAVI) and concomitant multi-vessel PCI. Case summary: A patient with acute heart failure, severely depressed systolic LV function, severe aortic stenosis, and multi-vessel coronary artery disease underwent TAVI and concomitant PCI under pulsatile LVAD. Notably, the patient experienced unexpected shortness of breath and elevated LVEDP while under LVAD, which normalized immediately upon LVAD removal. Discussion: Pulsatile LVAD enhances cardiac output by providing pulsatile support through a percutaneous bi-directional flow catheter. Despite expectations of reduced LVEDP and improved myocardial oxygen supply under LVAD support, we observed high LVEDP and clinical complaints of shortness of breath following TAVI and multi-vessel PCI. This case illustrates that an LVAD across the aortic valve may immobilize aortic leaflets and generate acute aortic regurgitation.

7.
Eur J Heart Fail ; 2024 Jun 02.
Article in English | MEDLINE | ID: mdl-38825743

ABSTRACT

AIMS: Heart failure (HF), a global pandemic affecting millions of individuals, calls for adequate predictive guidance for improved therapy. Congestion, a key factor in HF-related hospitalizations, further underscores the need for timely interventions. Proactive monitoring of intracardiac pressures, guided by pulmonary artery (PA) pressure, offers opportunities for efficient early-stage intervention, since haemodynamic congestion precedes clinical symptoms. METHODS: The BioMEMS study, a substudy of the MONITOR-HF trial, proposes a multifaceted approach integrating blood biobank data with traditional and novel HF parameters. Two additional blood samples from 340 active participants in the MONITOR-HF trial were collected at baseline, 3-, 6-, and 12-month visits and stored for the BioMEMS biobank. The main aims are to identify the relationship between temporal biomarker patterns and PA pressures derived from the CardioMEMS-HF system, and to identify the biomarker profile(s) associated with the risk of HF events and cardiovascular death. CONCLUSION: Since the prognostic value of single baseline measurements of biomarkers like N-terminal pro-B-type natriuretic peptide is limited, with the BioMEMS study we advocate a dynamic, serial approach to better capture HF progression. We will substantiate this by relating repeated biomarker measurements to PA pressures. This design rationale presents a comprehensive review on cardiac biomarkers in HF, and aims to contribute valuable insights into personalized HF therapy and patient risk assessment, advancing our ability to address the evolving nature of HF effectively.

8.
Am J Cardiol ; 223: 73-80, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-38777210

ABSTRACT

Recent trials suggested immediate complete revascularization (ICR) as a safe alternative to staged complete revascularization (SCR), but the impact of the respective percutaneous coronary intervention strategies between on- versus off-hours is unclear. On-hours was defined as an index revascularization performed between 8:00 a.m. and 6:00 p.m., Monday to Friday, or else the procedure was defined as performed during off-hours. The primary end point consisted of a composite of all-cause mortality, myocardial infarction, unplanned ischemia-driven revascularization, and cerebrovascular events at 1-year follow-up. We used Cox regression models to relate randomized treatment with study end points. We evaluated multiplicative and additive interactions between on- versus off-hours and randomized treatment. The BIOVASC (Percutaneous Complete Revascularization Strategies Using Sirolimus Eluting Biodegradable Polymer Coated Stents in Patients Presenting With Acute Coronary Syndromes and Multivessel Disease) trial enrolled 1,097 and 428 patients during on- and off-hours, respectively. Patients randomized during off-hours were more likely to present with ST-segment elevation myocardial infarction (66.4% vs 29.5%, p <0.001). The composite primary outcome occurred in 8.4% and 10.1% of patients randomized to ICR and SCR, respectively, during on-hours (hazard ratio 0.80, 95% confidence interval 0.54 to 1.19). During off-hours, the primary composite outcome occurred in 5.4% and 7.7% in ICR and SCR (0.69, 95% confidence interval 0.32 to 1.46) with no evidence of a differential effect (interaction pmultiplicative = 0.70, padditive = 0.56). No differential effect was found between treatment allocation and on- versus off-hours in any of the secondary outcomes. In conclusion, no differential treatment effect was found when comparing ICR versus SCR in patients presenting with acute coronary syndrome and multivessel disease during on- or off-hours.


Subject(s)
Drug-Eluting Stents , Percutaneous Coronary Intervention , Humans , Male , Female , Percutaneous Coronary Intervention/methods , Middle Aged , Aged , Time Factors , Acute Coronary Syndrome/surgery , Acute Coronary Syndrome/therapy , ST Elevation Myocardial Infarction/surgery , ST Elevation Myocardial Infarction/therapy , Myocardial Revascularization/methods , Myocardial Revascularization/statistics & numerical data , Coronary Artery Disease/surgery , Treatment Outcome , Sirolimus/therapeutic use , Follow-Up Studies
9.
Article in English | MEDLINE | ID: mdl-38795109

ABSTRACT

BACKGROUND: In patients with low-gradient aortic stenosis (AS) and low transvalvular flow, dobutamine stress echocardiography (DSE) is recommended to determine AS severity, whereas the degree of aortic valve calcification (AVC) supposedly correlates with AS severity according to current European and American guidelines. OBJECTIVES: The purpose of this study was to assess the relationship between AVC and AS severity as determined using echocardiography and DSE in patients with aortic valve area <1 cm2 and peak aortic valve velocity <4.0 m/s. METHODS: All patients underwent DSE to determine AS severity and multislice computed tomography to quantify AVC. Receiver-operating characteristics curve analysis was used to assess the diagnostic value of AVC for AS severity grading as determined using echocardiography and DSE in men and women. RESULTS: A total of 214 patients were included. Median age was 78 years (25th-75th percentile: 71-84 years) and 25% were women. Left ventricular ejection fraction was reduced (<50%) in 197 (92.1%) patients. Severe AS was diagnosed in 106 patients (49.5%). Moderate AS was diagnosed in 108 patients (50.5%; in 77 based on resting transthoracic echocardiography, in 31 confirmed using DSE). AVC score was high (≥2,000 for men or ≥1,200 for women) in 47 (44.3%) patients with severe AS and in 47 (43.5%) patients with moderate AS. AVC sensitivity was 44.3%, specificity was 56.5%, and positive and negative predictive values for severe AS were 50.0% and 50.8%, respectively. Area under the receiver-operating characteristics curve was 0.508 for men and 0.524 for women. CONCLUSIONS: Multi-slice computed tomography-derived AVC scores showed poor discrimination between grades of AS severity using DSE and cannot replace DSE in the diagnostic work-up of low-gradient severe AS.

10.
Eur Heart J Digit Health ; 5(3): 379-383, 2024 May.
Article in English | MEDLINE | ID: mdl-38774368

ABSTRACT

Aims: Invasive haemodynamic monitoring of heart failure (HF) is used to detect deterioration in an early phase thereby preventing hospitalizations. However, this invasive approach is costly and presently lacks widespread accessibility. Hence, there is a pressing need to identify an alternative non-invasive method that is reliable and more readily available. In this pilot study, we investigated the relation between wrist-derived photoplethysmography (PPG) signals and the invasively measured pulmonary capillary wedge pressure (PCWP). Methods and results: Fourteen patients with aortic valve stenosis who underwent transcatheter aortic valve replacement with concomitant right heart catheterization and PPG measurements were included. Six unique features of the PPG signals [heart rate, heart rate variability, systolic amplitude (SA), diastolic amplitude, crest time (CT), and large artery stiffness index (LASI)] were extracted. These features were used to estimate the continuous PCWP values and the categorized PCWP (low < 12 mmHg vs. high ≥ 12 mmHg). All PPG features resulted in regression models that showed low correlations with the invasively measured PCWP. Classification models resulted in higher performances: the model based on the SA and the model based on the LASI both resulted in an area under the curve (AUC) of 0.86 and the model based on the CT resulted in an AUC of 0.72. Conclusion: These results demonstrate the capability to non-invasively classify patients into clinically meaningful categories of PCWP using PPG signals from a wrist-worn wearable device. To enhance and fully explore its potential, the relationship between PPG and PCWP should be further investigated in a larger cohort of HF patients.

11.
EuroIntervention ; 20(9): 536-550, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38726720

ABSTRACT

The identification and management of patients at high bleeding risk (HBR) undergoing transcatheter aortic valve implantation (TAVI) are of major importance, but the lack of standardised definitions is challenging for trial design, data interpretation, and clinical decision-making. The Valve Academic Research Consortium for High Bleeding Risk (VARC-HBR) is a collaboration among leading research organisations, regulatory authorities, and physician-scientists from Europe, the USA, and Asia, with a major focus on TAVI-related bleeding. VARC-HBR is an initiative of the CERC (Cardiovascular European Research Center), aiming to develop a consensus definition of TAVI patients at HBR, based on a systematic review of the available evidence, to provide consistency for future clinical trials, clinical decision-making, and regulatory review. This document represents the first pragmatic approach to a consistent definition of HBR evaluating the safety and effectiveness of procedures, devices and drug regimens for patients undergoing TAVI..


Subject(s)
Consensus , Hemorrhage , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Risk Factors , Hemorrhage/etiology , Risk Assessment , Aortic Valve Stenosis/surgery , Aortic Valve/surgery
12.
ASAIO J ; 2024 May 20.
Article in English | MEDLINE | ID: mdl-38776488

ABSTRACT

Patients undergoing veno-arterial extracorporeal membrane oxygenation (VA-ECMO) typically suffer from cardiogenic pulmonary edema and lung atelectasis, which can exacerbate right ventricular (RV) dysfunction through an increase in lung elastance and RV afterload. Invasive mechanical ventilation settings, and positive end-expiratory pressure (PEEP) in particular, can help to improve RV performance by optimizing lung recruitment and minimizing alveolar overdistention. In this report, we present a VA-ECMO supported patient in whom in vivo RV pressure-volume (PV) loops were measured during a decremental PEEP trial, leading to the identification of an optimum PEEP level from a cardio-respiratory viewpoint. This innovative approach of tailoring mechanical ventilation settings according to cardio-respiratory physiology through in vivo RV PV loops may provide a novel way to optimize hemodynamics and patient outcomes.

14.
Am J Cardiol ; 223: 147-155, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-38641189

ABSTRACT

There are limited data from randomized controlled trials assessing the impact of transcatheter aortic valve replacement (TAVR) or surgery in women with aortic stenosis and small aortic annuli. We evaluated 2-year clinical and hemodynamic outcomes after aortic valve replacement to understand acute valve performance and early and midterm clinical outcomes. This post hoc analysis pooled women enrolled in the randomized, prospective, multicenter Evolut Low Risk and Surgical Replacement and Transcatheter Aortic Valve Implantation (SURTAVI) intermediate risk trials. Women with severe aortic stenosis at low or intermediate surgical risk who had a computed tomography-measured annular perimeter of ≤72.3 mm were included and underwent self-expanding, supra-annular TAVR or surgery. The primary end point was 2-year all-cause mortality or disabling stroke rate. The study included 620 women (323 TAVR, 297 surgery) with a mean age of 78 years. At 2 years, the all-cause mortality or disabling stroke was 6.5% for TAVR and 8.0% for surgery, p = 0.47. Pacemaker rates were 20.0% for TAVR and 8.3% for surgery, p <0.001. The mean effective orifice area at 2 years was 1.9 ± 0.5 cm2 for TAVR and 1.6 ± 0.5 cm2 for surgery and the mean gradient was 8.0 ± 4.1 versus 12.7 ± 6.0 mm Hg, respectively (both p <0.001). Moderate or severe patient-prothesis mismatch at discharge occurred in 10.9% of patients who underwent TAVR and 33.2% of patients who underwent surgery, p <0.001. In conclusion, in women with small annuli, the clinical outcomes to 2 years were similar between self-expanding, supra-annular TAVR and surgery, with better hemodynamics in the TAVR group and fewer pacemakers in the surgical group.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Transcatheter Aortic Valve Replacement , Humans , Female , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/surgery , Aged , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Prospective Studies , Aged, 80 and over , Heart Valve Prosthesis Implantation/methods , Treatment Outcome , Risk Factors , Severity of Illness Index , Risk Assessment/methods , Postoperative Complications/epidemiology , Tomography, X-Ray Computed , Heart Valve Prosthesis
15.
EuroIntervention ; 20(8): e487-e495, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38629416

ABSTRACT

BACKGROUND: Data on the likelihood of left ventricle (LV) recovery in patients with severe LV dysfunction and severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI) and its prognostic value are limited. AIMS: We aimed to assess the likelihood of LV recovery following TAVI, examine its association with midterm mortality, and identify independent predictors of LV function. METHODS: In our multicentre registry of 17 TAVI centres in Western Europe and Israel, patients were stratified by baseline LV function (ejection fraction [EF] >/≤30%) and LV response: no LV recovery, LV recovery (EF increase ≥10%), and LV normalisation (EF ≥50% post-TAVI). RESULTS: Our analysis included 10,872 patients; baseline EF was ≤30% in 914 (8.4%) patients and >30% in 9,958 (91.6%) patients. The LV recovered in 544 (59.5%) patients, including 244 (26.7%) patients whose LV function normalised completely (EF >50%). Three-year mortality for patients without severe LV dysfunction at baseline was 29.4%. Compared to this, no LV recovery was associated with a significant increase in mortality (adjusted hazard ratio 1.32; p<0.001). Patients with similar LV function post-TAVI had similar rates of 3-year mortality, regardless of their baseline LV function. Three variables were associated with a higher likelihood of LV recovery following TAVI: no previous myocardial infarction (MI), estimated glomerular filtration rate >60 mL/min, and mean aortic valve gradient (mAVG) (expressed either as a continuous variable or as a binary variable using the standard low-flow, low-gradient aortic stenosis [AS] definition). CONCLUSIONS: LV recovery following TAVI and the extent of this recovery are major determinants of midterm mortality in patients with severe AS and severe LV dysfunction undergoing TAVI. Patients with no previous MI and those with an mAVG >40 mmHg show the best results following TAVI, which are at least equivalent to those for patients without severe LV dysfunction. (ClinicalTrials.gov: NCT04031274).


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Ventricular Dysfunction, Left , Humans , Aortic Valve/surgery , Heart Ventricles , Stroke Volume , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , Ventricular Function, Left , Multicenter Studies as Topic , Clinical Studies as Topic
16.
JACC Cardiovasc Interv ; 17(7): 890-903, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38599692

ABSTRACT

BACKGROUND: Mitral transcatheter edge-to-edge repair (M-TEER) is a guideline-recommended treatment option for patients with severe symptomatic mitral regurgitation (MR). Outcomes with the PASCAL system in a post-market setting have not been established. OBJECTIVES: The authors report 30-day and 1-year outcomes from the MiCLASP (Transcatheter Repair of Mitral Regurgitation with Edwards PASCAL Transcatheter Valve Repair System) European post-market clinical follow-up study. METHODS: Patients with symptomatic, clinically significant MR were prospectively enrolled. The primary safety endpoint was clinical events committee-adjudicated 30-day composite major adverse event rate and the primary effectiveness endpoint was echocardiographic core laboratory-assessed MR severity at discharge compared with baseline. Clinical, echocardiographic, functional, and quality-of-life outcomes were assessed at 1 year. RESULTS: A total of 544 patients were enrolled (59% functional MR, 30% degenerative MR). The 30-day composite major adverse event rate was 6.8%. MR reduction was significant from baseline to discharge and sustained at 1 year with 98% of patients achieving MR ≤2+ and 82.6% MR ≤1+ (all P < 0.001 vs baseline). One-year Kaplan-Meier estimate for survival was 87.3%, and freedom from heart failure hospitalization was 84.3%. Significant functional and quality-of-life improvements were observed at 1 year, including 71.6% in NYHA functional class I/II, 14.4-point increase in Kansas City Cardiomyopathy Questionnaire score, and 24.2-m improvement in 6-minute walk distance (all P < 0.001 vs baseline). CONCLUSIONS: One-year outcomes of this large cohort from the MiCLASP study demonstrate continued safety and effectiveness of M-TEER with the PASCAL system in a post-market setting. Results demonstrate high survival and freedom from heart failure hospitalization, significant and sustained MR reduction, and improvements in symptoms, functional capacity, and quality of life.


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Follow-Up Studies , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Quality of Life , Treatment Outcome , Heart Valve Prosthesis Implantation/adverse effects , Cardiac Catheterization/adverse effects
17.
EuroIntervention ; 20(7): e436-e444, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38562070

ABSTRACT

BACKGROUND: The effect of administering a crushed prasugrel loading dose is uncertain in patients presenting with a large myocardial infarction and ST-segment elevation myocardial infarction (STEMI). AIMS: The aim of this study was to investigate if patients with a large myocardial infarction may benefit from prehospital administration of a crushed prasugrel loading dose. METHODS: Patients from the CompareCrush trial with an available ambulance electrocardiography (ECG) were included in the study. An independent core laboratory confirmed a prehospital large myocardial area. We compared pre- and postprocedural angiographic markers, including Thrombolysis in Myocardial Infarction (TIMI) 3 flow in the infarct-related artery, high thrombus burden, and myocardial blush grade 3, in STEMI patients with and without a prehospital large myocardial area. RESULTS: Ambulance ECG was available for 532 patients, of whom 331 patients were identified with a prehospital large myocardial area at risk. Crushed prasugrel significantly improved postprocedural TIMI 3 flow rates in STEMI patients with a prehospital large myocardial area at risk (92% vs 79%, odds ratio [OR] 3.00, 95% confidence interval [CI]: 1.50-6.00) but not in STEMI patients without a prehospital large myocardial area at risk (91% vs 95%, OR 0.47, 95% CI: 0.14-1.57; pinteraction=0.009). CONCLUSIONS: Administration of crushed prasugrel may improve postprocedural TIMI 3 flow in STEMI patients with signs of a large myocardial area at risk on the ambulance ECG. The practice of crushing tablets of prasugrel loading dose might, therefore, represent a safe, fast and cost-effective strategy to improve myocardial reperfusion in this high-risk STEMI subgroup undergoing primary percutaneous coronary intervention.


Subject(s)
Emergency Medical Services , Myocardial Infarction , Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction , Humans , Myocardial Infarction/drug therapy , Percutaneous Coronary Intervention/adverse effects , Platelet Aggregation Inhibitors/therapeutic use , Prasugrel Hydrochloride/therapeutic use , ST Elevation Myocardial Infarction/drug therapy , Treatment Outcome
18.
EuroIntervention ; 20(8): e479-e486, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38629415

ABSTRACT

BACKGROUND: In patients presenting with acute coronary syndrome (ACS), the number of diseased vessels may affect the efficacy of a complete revascularisation strategy. AIMS: The authors sought to evaluate the safety and efficacy of immediate complete revascularisation (ICR) and staged complete revascularisation (SCR) in patients presenting with ACS stratified by the number of diseased vessels. METHODS: In this prespecified analysis of the BIOVASC trial, ICR was compared with SCR in patients with two-vessel disease (2VD) or three-vessel disease (3VD). The primary endpoint was a composite of all-cause mortality, myocardial infarction (MI), any unplanned ischaemia-driven revascularisation or cerebrovascular events at 1 year after the index procedure. Comparisons were performed using Cox regression. RESULTS: A total of 1,525 patients were enrolled in the BIOVASC trial, of whom 1,177 presented with 2VD and 265 with 3VD. In the 2VD group, 613 patients were assigned to ICR and 564 to SCR. In the 3VD group, 117 patients were assigned to ICR and 148 to SCR. ICR and SCR led to similar results in both the 2VD (hazard ratio [HR] 0.76, 95% confidence interval [CI]: 0.50-1.13; p=0.18) and 3VD groups (HR 0.79, 95% CI: 0.39-1.59; p=0.51) (pinteraction=0.91) in terms of the primary endpoint. ICR was associated with a lower rate of MI in patients with 3VD (HR 0.21, 95% CI: 0.046-0.93; p=0.04) (pinteraction=0.30). CONCLUSIONS: ICR might be an option in patients presenting with extensive 3VD and might be associated with a lower rate of myocardial infarction compared with SCR.


Subject(s)
Acute Coronary Syndrome , Coronary Artery Disease , Myocardial Infarction , Percutaneous Coronary Intervention , Humans , Acute Coronary Syndrome/surgery , Treatment Outcome , Coronary Artery Bypass/methods , Vascular Surgical Procedures , Percutaneous Coronary Intervention/methods , Coronary Artery Disease/surgery
19.
Clin Res Cardiol ; 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38619575

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation (TAVI) serves a growing range of patients with severe aortic stenosis (AS). TAVI has evolved to a streamlined procedure minimizing length of hospital stay. AIMS: To evaluate the safety and efficacy of an early discharge (ED) strategy after TAVI. METHODS: We performed an international, multi-center, prospective observational single-arm study in AS patients undergoing TAVI with the ACURATE valve platform. Eligibility for ED was assessed prior to TAVI and based on prespecified selection criteria. Discharge ≤ 48 h was defined as ED. Primary Valve Academic Research Consortium (VARC)-3-defined 30-day safety and efficacy composite endpoints were landmarked at 48 h and compared between ED and non-ED groups. RESULTS: A total of 252 patients were included. The median age was 82 [25th-75th percentile, 78-85] years and the median Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) score was 2.2% [25th-75th percentile, 1.6-3.3]. ED and non-ED were achieved in 173 (69%) and 79 (31%) patients respectively. Monitoring for conduction disturbances was the principal reason for non-ED (33%). Overall, at 30 days, all-cause mortality was 1%, new permanent pacemaker rate was 4%, and valve- or procedure-related rehospitalization was 4%. There was no difference in the primary safety and efficacy endpoint between the ED and non-ED cohorts (OR 0.84 [25th-75th percentile, 0.31-2.26], p = 0.73, and OR 0.97 [25th-75th percentile, 0.46-2.06], p = 0.94). The need for rehospitalization was similarly low for ED and non-ED groups. CONCLUSION: Early discharge after TAVI with the ACURATE valve is safe and feasible in selected patients. Rhythm monitoring and extended clinical observation protracted hospital stay.

20.
JACC Cardiovasc Interv ; 17(8): 1007-1016, 2024 Apr 22.
Article in English | MEDLINE | ID: mdl-38573257

ABSTRACT

BACKGROUND: Data on valve reintervention after transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) are limited. OBJECTIVES: The authors compared the 5-year incidence of valve reintervention after self-expanding CoreValve/Evolut TAVR vs SAVR. METHODS: Pooled data from CoreValve and Evolut R/PRO (Medtronic) randomized trials and single-arm studies encompassed 5,925 TAVR (4,478 CoreValve and 1,447 Evolut R/PRO) and 1,832 SAVR patients. Reinterventions were categorized by indication, timing, and treatment. The cumulative incidence of reintervention was compared between TAVR vs SAVR, Evolut vs CoreValve, and Evolut vs SAVR. RESULTS: There were 99 reinterventions (80 TAVR and 19 SAVR). The cumulative incidence of reintervention through 5 years was higher with TAVR vs SAVR (2.2% vs 1.5%; P = 0.017), with differences observed early (≤1 year; adjusted subdistribution HR: 3.50; 95% CI: 1.53-8.02) but not from >1 to 5 years (adjusted subdistribution HR: 1.05; 95% CI: 0.48-2.28). The most common reason for reintervention was paravalvular regurgitation after TAVR and endocarditis after SAVR. Evolut had a significantly lower incidence of reintervention than CoreValve (0.9% vs 1.6%; P = 0.006) at 5 years with differences observed early (adjusted subdistribution HR: 0.30; 95% CI: 0.12-0.73) but not from >1 to 5 years (adjusted subdistribution HR: 0.61; 95% CI: 0.21-1.74). The 5-year incidence of reintervention was similar for Evolut vs SAVR (0.9% vs 1.5%; P = 0.41). CONCLUSIONS: A low incidence of reintervention was observed for CoreValve/Evolut R/PRO and SAVR through 5 years. Reintervention occurred most often at ≤1 year for TAVR and >1 year for SAVR. Most early reinterventions were with the first-generation CoreValve and managed percutaneously. Reinterventions were more common following CoreValve TAVR compared with Evolut TAVR or SAVR.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Postoperative Complications , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Female , Humans , Male , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Postoperative Complications/surgery , Prosthesis Design , Randomized Controlled Trials as Topic , Risk Assessment , Risk Factors , Severity of Illness Index , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Treatment Outcome , Incidence , Retreatment
SELECTION OF CITATIONS