Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
IEEE Trans Nucl Sci ; 62(3): 694-698, 2015 Jun.
Article in English | MEDLINE | ID: mdl-26538685

ABSTRACT

Metabolic imaging techniques can potentially improve detection and diagnosis of cancer in women with radiodense and/or fibrocystic breasts. Our group has previously developed a high-resolution positron emission tomography imaging and biopsy device (PEM-PET) to detect and guide the biopsy of suspicious breast lesions. Initial testing revealed that the imaging field-of-view (FOV) of the scanner was smaller than the physical size of the detector's active area, which could hinder sampling of breast areas close to the chest wall. The purpose of this work was to utilize segmented, tapered light guides for optically coupling the scintillator arrays to arrays of position-sensitive photomultipliers to increase both the active FOV and identification of individual scintillator elements. Testing of the new system revealed that the optics of these structures made it possible to discern detector elements from the complete active area of the detector face. In the previous system the top and bottom rows and left and right columns were not identifiable. Additionally, use of the new light guides increased the contrast of individual detector elements by up to 129%. Improved element identification led to a spatial resolution increase by approximately 12%. Due to attenuation of light in the light guides the detector energy resolution decreased from 18.5% to 19.1%. Overall, these improvements should increase the field-of-view and spatial resolution of the dedicated breast-PET system.

2.
Phys Med Biol ; 56(1): 139-53, 2011 Jan 07.
Article in English | MEDLINE | ID: mdl-21119228

ABSTRACT

By using detectors with good depth encoding accuracy (∼2 mm), an animal PET scanner can be built with a small ring diameter and thick crystals to simultaneously obtain high spatial resolution and high sensitivity. However, there will be large wedge-shaped gaps between detector modules in such a scanner if traditional cuboid crystal arrays are used in a polygonal arrangement. The gaps can be minimized by using tapered scintillator arrays enabling the sensitivity of the scanner to be further improved. In this work, tapered lutetium oxyorthosilicate (LSO) arrays with different crystal dimensions and different combinations of inter-crystal reflector and crystal surface treatments were manufactured and their performance was evaluated. Arrays were read out from both ends by position-sensitive avalanche photodiodes (PSAPDs). In the optimal configuration, arrays consisting of 0.5 mm LSO elements could be clearly resolved and a depth of interaction resolution of 2.6 mm was obtained for a 20 mm thick array. For this tapered array, the intrinsic spatial is degraded from 0.67 to 0.75 mm compared to a standard cuboidal array with similar dimensions, while the increase in efficiency is 41%. Tapered scintillator arrays offer the prospect of improvements in sensitivity and sampling for small-bore scanners, without large increases in manufacturing complexity.


Subject(s)
Lutetium , Positron-Emission Tomography/instrumentation , Silicates , Animals , Equipment Design , Lutetium/chemistry , Positron-Emission Tomography/methods , Reproducibility of Results , Sensitivity and Specificity , Silicates/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...