Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Opt Express ; 32(1): 703-721, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38175093

ABSTRACT

Optical metasurface technology promises an important potential for replacing bulky traditional optical components, in addition to enabling new compact and lightweight metasurface-based devices. Since even subtle imperfections in metasurface design or manufacture strongly affect their performance, there is an urgent need to develop proper and accurate protocols for their characterization, allowing for efficient control of the fabrication. We present non-destructive spectroscopic Mueller matrix ellipsometry in an uncommon off-specular configuration as a powerful tool for the characterization of orthogonal polarization beam-splitters based on a-Si:H nanopillars. Through Mueller matrix analysis, the spectroscopic polarimetric performance of the ±1 diffraction orders is experimentally demonstrated. This reveals a wavelength shift in the maximum efficiency caused by fabrication-induced conical pillars while still maintaining a polarimetric response close to ideal non-depolarizing Mueller matrices. We highlight the advantage of the spectroscopic Mueller matrix approach, which not only allows for monitoring and control of the fabrication process itself, but also verifies the initial design and produces feedback into the computational design.

2.
RSC Adv ; 13(10): 6582-6592, 2023 Feb 21.
Article in English | MEDLINE | ID: mdl-36860536

ABSTRACT

Spectroscopic Mueller matrix ellipsometry is becoming increasingly routine across physical branches of science, even outside optics. The highly sensitive tracking of the polarization-related physical properties offers a reliable and non-destructive analysis of virtually any sample at hand. If coupled with a physical model, it is impeccable in performance and irreplaceable in versatility. Nonetheless, this method is rarely adopted interdisciplinarily, and when it is, it often plays a supporting role, which does not take benefit of its full potential. To bridge this gap, we present Mueller matrix ellipsometry in the context of chiroptical spectroscopy. In this work, we utilize a commercial broadband Mueller ellipsometer to analyze the optical activity of a saccharides solution. We verify the correctness of the method in the first place by studying the well-known rotatory power of glucose, fructose, and sucrose. By employing a physically meaningful dispersion model, we obtain 2π-unwrapped absolute specific rotations. Besides that, we demonstrate the capability of tracing the glucose mutarotation kinetics from just one set of measurements. Coupling the Mueller matrix ellipsometry with the proposed dispersion model ultimately leads to the precisely determined mutarotation rate constants and spectrally and temporally resolved gyration tensor of individual glucose anomers. In this view, Mueller matrix ellipsometry may stand as an offbeat yet equal technique to those considered classical chiroptical spectroscopy techniques, which may help open new opportunities for broader polarimetric applications in biomedicine and chemistry.

3.
Article in English | MEDLINE | ID: mdl-36834447

ABSTRACT

We aim to examine the cross-education effects of unilateral muscle neuromuscular electrical stimulation (NMES) training combined with illusionary mirror visual feedback (MVF). Fifteen adults (NMES + MVF: 5; NMES: 5, Control: 5) completed this study. The experimental groups completed a 3-week NMES training on their dominant elbow flexor muscle. The NMES + MVF group had a mirror placed in the midsagittal plane between their upper arms, so a visual illusion was created in which their non-dominant arms appeared to be stimulated. Baseline and post-training measurements included both arms' isometric strength, voluntary activation level, and resting twitch. Cross-education effects were not observed from all dependent variables. For the unilateral muscle, both experimental groups showed greater strength increases when compared to the control (isometric strength % changes: NMES + MVF vs. NMES vs. Control = 6.31 ± 4.56% vs. 4.72 ± 8.97% vs. -4.04 ± 3.85%, p < 0.05). Throughout the training, even with the maximally tolerated NMES, the NMES + MVF group had greater perceived exertion and discomfort than the NMES. Additionally, the NMES-evoked force increased throughout the training for both groups. Our data does not support that NMES combined with or without MVF induces cross-education. However, the stimulated muscle becomes more responsive to the NMES and can become stronger following the training.


Subject(s)
Feedback, Sensory , Illusions , Adult , Humans , Pilot Projects , Muscle, Skeletal/physiology , Electric Stimulation , Muscle Strength/physiology
4.
Sports (Basel) ; 10(9)2022 Sep 05.
Article in English | MEDLINE | ID: mdl-36136389

ABSTRACT

This study aimed to examine the potential sex differences in wide-pulse high-frequency neuromuscular electrical stimulation (WPHF NMES)-evoked force. Twenty-two subjects (10 women) completed this study. Prior to the stimulation, the visual analogue scale (VAS) for discomfort and the rating of perceived exertion (RPE) were measured, followed by the isometric strength of the dominant elbow flexor muscles. The subjects then completed ten, 10-s on 10-s off WPHF NMES (pulse width: 1 ms, frequency: 100 Hz) at maximum tolerable intensities. The subjects' RPE was recorded after each set, and the VAS was measured following the last stimulation. The stimulation induced significant increase in discomfort for both sexes, with women having greater discomfort than men (men: 22.4 ± 14.9 mm, women: 39.7 ± 12.7 mm). The stimulation amplitude was significantly greater in men than in women (men: 16.2 ± 6.3 mA, women: 12.0 ± 4.5 mA). For the evoked force, only the relative NMES-evoked force was found greater in women than in men (men: 8.96 ± 6.51%, women: 17.08 ± 12.61%). In conclusion, even at the maximum tolerable intensity, WPHF NMES evoked larger relative elbow flexion force in women than in men, with women experiencing greater discomfort.

5.
Opt Express ; 29(7): 10434-10450, 2021 Mar 29.
Article in English | MEDLINE | ID: mdl-33820178

ABSTRACT

Mueller matrix ellipsometry has been used to precisely characterize quartz waveplates for demanding applications in the semiconductor industry and high precision polarimetry. We have found this experimental technique to be beneficial to use because it enables us to obtain absolute and precise measurement of retardation in a wide spectral range, waveplate orientation, and compound waveplate adjustment. In this paper, the necessity of including the optical activity in the Mueller matrix model and data treatment is demonstrated. Particularly, the optical activity of the quartz influences the adjustment of misalignment between the perpendicularly oriented waveplates of the compound biplate. We demonstrate that omitting the optical activity from the model leads to inaccurate values of the misalignment. In addition, the depolarization effects caused by a finite monochromator bandwidth is included in the model. Incorporation of the optical activity to the Mueller matrix model has required a development of rigorous theory based on appropriate constitutive equations. The generalized Yeh's matrix algebra to bianisotropic media has been used for the calculation of the eigenmodes propagation in chiral materials with reduced symmetry. Based on the applied method, the authors have proposed approximated analytical form of the Mueller matrix representing optically active waveplate and biplate and provided discussion on the analytical and numerical limits of the method.

SELECTION OF CITATIONS
SEARCH DETAIL
...