Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Electron Physician ; 10(5): 6775-6780, 2018 May.
Article in English | MEDLINE | ID: mdl-29997761

ABSTRACT

BACKGROUND: Dobutamine stress echocardiography (DSE) is a non-invasive technique to detect coronary artery diseases (CAD). There are limited studies on evaluation of the right ventricular function by stress echocardiography. The appropriate evaluation of RV function and early diagnosis of its failure can help to improve outcomes for the patients undergoing cardiac surgery. OBJECTIVE: To determine right ventricular dysfunction in patients with three-vessel CAD by using DSE. METHODS: This cross-sectional study was among 13 patients who were candidates for coronary artery bypass grafting (CABG) referred to Ghaem Hospital, Mashhad, Iran; from September 2015 to May 2016. After a physical examination and initial measures, DSE was performed and echocardiographic parameters were recorded by a cardiologist. Paired-samples t-test was performed using SPSS Software v.16.0 for data analysis. RESULTS: The study included 13 patients (9 males) with a mean age of 65.4±7.6 years. The mean of TAPS was 16.9±4.5 mm and 15.7±2.9 mm before and after stress echocardiography, respectively (p=0.69). Systolic right ventricular (SRV) peak increased from before DSE compared with after DSE (8.0±2.2 vs. 13.7±4.2 mm/s, p<0.001). In addition, after dobutamine injection, right ventricular (RV) cardiac output decreased in 7 patients and one patient was affected by post-ejection shortening. CONCLUSION: It seems that TAPS and RV cardiac output after injection of dobutamine, can be used as markers for the recognition of ischemic RV dysfunction.

2.
Int J Prev Med ; 4(12): 1476-9, 2013 Dec.
Article in English | MEDLINE | ID: mdl-24498506

ABSTRACT

BACKGROUND: The aim of study was to compare the serum level of magnesium in mothers having low birth weight with those having normal birth weight neonates. METHODS: In a case-control study, women who delivered low birth weight neonate (cases), compared with normal birth weight (controls) in serum concentration of magnesium. Blood samples collected within 24 h after delivery. Concentration of magnesium assessed by standard atomic absorption spectro-photometry. Multiple linear regression analysis was performed to control of potential confounding variables. RESULTS: A total of 116 mothers (67 cases and 49 control) were studied. Mothers in two groups did not differ in age, body mass index, and socioeconomic or demographic factors. Maternal magnesium concentration did not differ between two groups 0.86 ± 0.11 m.mol/l versus 0.94 ± 0.22 m.mol/l respectively (P = 0.09). CONCLUSION: There is no significant difference between serum magnesium levels of low birth weight infants' mother and normal weight infants' mother.

SELECTION OF CITATIONS
SEARCH DETAIL
...