Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
Add more filters










Publication year range
1.
Appl Radiat Isot ; 166: 109315, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32966949

ABSTRACT

Existing and active low-energy Accelerator-Based BNCT programs worldwide will be reviewed and compared. In particular, the program in Argentina will be discussed which consists of the development of an Electro-Static-Quadrupole (ESQ) Accelerator-Based treatment facility. The facility is conceived to operate with the deuteron-induced reactions 9Be(d,n)10B and 13C(d,n)14N at 1.45 MeV deuteron energy, as neutron sources. Neutron production target development status is specified. The present status of the construction of the new accelerator development laboratory and future BNCT centre is shown.

2.
Appl Radiat Isot ; 106: 18-21, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26320739

ABSTRACT

In this work we provide some information on the present status of accelerator-based BNCT (AB-BNCT) worldwide and subsequently concentrate on the recent accelerator technology developments in Argentina.


Subject(s)
Boron Neutron Capture Therapy/instrumentation , Argentina
3.
Appl Radiat Isot ; 88: 185-9, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24365468

ABSTRACT

The activity in accelerator development for accelerator-based BNCT (AB-BNCT) both worldwide and in Argentina is described. Projects in Russia, UK, Italy, Japan, Israel, and Argentina to develop AB-BNCT around different types of accelerators are briefly presented. In particular, the present status and recent progress of the Argentine project will be reviewed. The topics will cover: intense ion sources, accelerator tubes, transport of intense beams, beam diagnostics, the (9)Be(d,n) reaction as a possible neutron source, Beam Shaping Assemblies (BSA), a treatment room, and treatment planning in realistic cases.


Subject(s)
Boron Neutron Capture Therapy/instrumentation , Particle Accelerators/instrumentation , Radiometry/instrumentation , Equipment Design , Equipment Failure Analysis , Internationality , Technology Assessment, Biomedical
4.
Appl Radiat Isot ; 69(12): 1688-91, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21592806

ABSTRACT

This work reports on the characterisation of a neutron beam shaping assembly (BSA) prototype and on the preliminary modelling of a treatment room for BNCT within the framework of a research programme for the development and construction of an accelerator-based BNCT irradiation facility in Buenos Aires, Argentina. The BSA prototype constructed has been characterised by means of MCNP simulations as well as a set of experimental measurements performed at the Tandar accelerator at the National Atomic Energy Commission of Argentina.


Subject(s)
Boron Neutron Capture Therapy/instrumentation , Models, Theoretical , Argentina , Static Electricity
5.
Appl Radiat Isot ; 69(12): 1668-71, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21411330

ABSTRACT

A numerical optimization of a Beam Shaping Assembly (BSA) for Accelerator Based-Boron Neutron Capture Therapy (AB-BNCT) has been performed. The reaction (7)Li(p,n)(7)Be has been considered using a proton beam on a lithium fluoride target. Proton energy and the dimensions of a simple BSA geometry have been varied to obtain a set of different configurations. The optimal configuration of this set is shown.

6.
Appl Radiat Isot ; 69(12): 1672-5, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21353577

ABSTRACT

We describe the present status of an ongoing project to develop a Tandem-ElectroStatic-Quadrupole (TESQ) accelerator facility for Accelerator-Based (AB)-BNCT. The project final goal is a machine capable of delivering 30 mA of 2.4 MeV protons to be used in conjunction with a neutron production target based on the (7)Li(p,n)(7)Be reaction. The machine currently being constructed is a folded TESQ with a high-voltage terminal at 0.6 MV. We report here on the progress achieved in a number of different areas.


Subject(s)
Boron Neutron Capture Therapy , Boron Neutron Capture Therapy/instrumentation , Static Electricity
7.
Appl Radiat Isot ; 69(12): 1676-9, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21421324

ABSTRACT

Several ion sources have been developed and an ion source test stand has been mounted for the first stage of a Tandem-Electrostatic-Quadrupole facility For Accelerator-Based Boron Neutron Capture Therapy. A first source, designed, fabricated and tested is a dual chamber, filament driven and magnetically compressed volume plasma proton ion source. A 4 mA beam has been accelerated and transported into the suppressed Faraday cup. Extensive simulations of the sources have been performed using both 2D and 3D self-consistent codes.


Subject(s)
Boron Neutron Capture Therapy , Static Electricity
8.
Appl Radiat Isot ; 69(12): 1649-53, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21339070

ABSTRACT

Within the frame of an ongoing project to develop a folded Tandem-Electrostatic-Quadrupole (TESQ) accelerator facility for Accelerator-Based Boron Neutron Capture Therapy (AB-BNCT), we discuss here the electrostatic design of the machine, including the accelerator tubes with electrostatic quadrupoles and the simulations for the transport and acceleration of a high intensity beam.

9.
Appl Radiat Isot ; 69(12): 1680-3, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21334904

ABSTRACT

The accelerator tubes are essential components of the accelerator. Their function is to transport and accelerate a very intense proton or deuteron beam through the machine, from the ion source to the neutron production target, without significant losses. In this contribution, we discuss materials selected for the tube construction, the procedures used for their assembly and the testing performed to meet the stringent requirements to which it is subjected.


Subject(s)
Boron Neutron Capture Therapy/instrumentation , Equipment Design , Static Electricity
10.
Appl Radiat Isot ; 69(12): 1858-61, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21316978

ABSTRACT

This work discusses the development of online dosimetry of the boron dose via Single Photon Emission Computed Tomography (SPECT) during a BNCT treatment irradiation. Such a system will allow the online computation of boron dose maps without the large current uncertainties in the assessment of the boron concentration in different tissues. The first tomographic boron dose image with a SPECT prototype is shown.


Subject(s)
Boron Neutron Capture Therapy , Neutrons , Tomography, Emission-Computed, Single-Photon
11.
Appl Radiat Isot ; 67(7-8 Suppl): S266-9, 2009 Jul.
Article in English | MEDLINE | ID: mdl-19376714

ABSTRACT

In this work we describe the present status of an ongoing project to develop a tandem-electrostatic-quadrupole (TESQ) accelerator facility for accelerator-based (AB) BNCT at the Atomic Energy Commission of Argentina in Buenos Aires. The project final goal is a machine capable of delivering 30 mA of 2.4 MeV protons to be used in conjunction with a neutron production target based on the (7)Li(p,n)(7)Be reaction slightly beyond its resonance at 2.25 MeV. These are the specifications needed to produce sufficiently intense and clean epithermal neutron beams, based on the (7)Li(p,n)(7)Be reaction, to perform BNCT treatment for deep-seated tumors in less than an hour. An electrostatic machine is the technologically simplest and cheapest solution for optimized AB-BNCT. The machine being designed and constructed is a folded TESQ with a high-voltage terminal at 1.2 MV intended to work in air. Such a machine is conceptually shown to be capable of transporting and accelerating a 30 mA proton beam to 2.4 MeV. The general geometric layout, its associated electrostatic fields, and the acceleration tube are simulated using a 3D finite element procedure. The design and construction of the ESQ modules is discussed and their electrostatic fields are investigated. Beam transport calculations through the accelerator are briefly mentioned. Likewise, work related to neutron production targets, strippers, beam shaping assembly and patient treatment room is briefly described.


Subject(s)
Boron Neutron Capture Therapy/instrumentation , Particle Accelerators , Argentina , Biophysical Phenomena , Brain Neoplasms/radiotherapy , Facility Design and Construction , Humans , Static Electricity
12.
Appl Radiat Isot ; 67(7-8 Suppl): S179-82, 2009 Jul.
Article in English | MEDLINE | ID: mdl-19386504

ABSTRACT

This article reports on the development of a prototype of a SPECT tomograph system for online dosimetry in BNCT based on LaBr(3)(Ce) scintillation detectors. The setup shielding was optimized to be used in the accelerator based BNCT facility of the University of Birmingham. The system was designed and built. An image of a (241)Am point source was reconstructed. A projection of a phantom with two tumors with 400 microg/g of (10)B was measured at the BNCT facility.


Subject(s)
Boron Neutron Capture Therapy/statistics & numerical data , Radiotherapy Planning, Computer-Assisted/statistics & numerical data , Tomography, Emission-Computed, Single-Photon/statistics & numerical data , Boron/therapeutic use , Boron Neutron Capture Therapy/instrumentation , England , Equipment Design , Humans , Isotopes/therapeutic use , Neoplasms/radiotherapy , Phantoms, Imaging/statistics & numerical data , Radiation-Sensitizing Agents/therapeutic use , Radiotherapy Planning, Computer-Assisted/instrumentation , Tomography, Emission-Computed, Single-Photon/instrumentation
13.
Appl Radiat Isot ; 61(5): 771-4, 2004 Nov.
Article in English | MEDLINE | ID: mdl-15308142

ABSTRACT

Microdistributions of the prospective BNCT-compound CuTCPH, a carborane-containing tetraphenylporphyrin with one Cu atom in its molecular structure, have been obtained in tissue sections of different organs of tumor-bearing and normal Syrian hamsters injected with the boron compound by employing a heavy ion microbeam. High resolution X-ray spectroscopy following micro-PIXE (Particle Induced X-ray Emission with micrometer-sized beams) with a focused (16)O ion beam was used. Focusing was performed with a heavy-ion scanning high-precision magnetic quadrupole triplet microprobe. Squamous Cell Carcinomas were induced on the right Cheek Pouch of Syrian Hamsters (HCP), sampled, cryo-sectioned and freeze-dried. Two-dimensional maps of elemental concentration were obtained by scanning the beam over the samples. Very non-uniform Cu concentrations were found in all sections.


Subject(s)
Boron Neutron Capture Therapy/methods , Metalloporphyrins/pharmacokinetics , Metalloporphyrins/therapeutic use , Animals , Boron Neutron Capture Therapy/instrumentation , Carcinoma, Squamous Cell/metabolism , Carcinoma, Squamous Cell/radiotherapy , Cheek , Cricetinae , Mesocricetus , Mouth Neoplasms/metabolism , Mouth Neoplasms/radiotherapy , Spectrometry, X-Ray Emission , Tissue Distribution
14.
Appl Radiat Isot ; 61(5): 811-5, 2004 Nov.
Article in English | MEDLINE | ID: mdl-15308149

ABSTRACT

Different materials and proton beam energies have been studied in order to search for an optimized neutron production target and beam shaping assembly for accelerator-based BNCT. The solution proposed in this work consists of successive stacks of Al, polytetrafluoroethylene, commercially known as Teflon, and LiF as moderator and neutron absorber, and Pb as reflector. This assembly is easy to build and its cost is relatively low. An exhaustive Monte Carlo simulation study has been performed evaluating the doses delivered to a Snyder model head phantom by a neutron production Li-metal target based on the (7)Li(p,n)(7)Be reaction for proton bombarding energies of 1.92, 2.0, 2.3 and 2.5 MeV. Three moderator thicknesses have been studied and the figures of merit show the advantage of irradiating with near-resonance-energy protons (2.3 MeV) because of the relatively high neutron yield at this energy, which at the same time keeps the fast neutron healthy tissue dose limited and leads to the lowest treatment times. A moderator of 34 cm length has shown the best performance among the studied cases.


Subject(s)
Boron Neutron Capture Therapy/instrumentation , Aluminum , Boron Neutron Capture Therapy/statistics & numerical data , Brain Neoplasms/radiotherapy , Equipment Design , Fluorides , Humans , Lead , Lithium Compounds , Monte Carlo Method , Phantoms, Imaging , Polytetrafluoroethylene , Radiotherapy Planning, Computer-Assisted/statistics & numerical data
SELECTION OF CITATIONS
SEARCH DETAIL
...