Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 60
Filter
1.
Ann Vasc Surg ; 106: 80-89, 2024 Apr 04.
Article in English | MEDLINE | ID: mdl-38579908

ABSTRACT

BACKGROUND: The study aims to describe midterm outcomes following treatment of infrarenal abdominal aortic aneurysms (AAAs) with short necks by endosutured aneurysm repair using the Heli-FX EndoAnchor system. METHODS: This is a retrospective study of prospectively collected data from 9 vascular surgery departments between June 2010 and December 2019, including treated AAAs with neck lengths ≤10 mm. The decision for the use of EndoAnchors was made by the treating surgeon or multidisciplinary aortic committee according to each center's practice. There were 2 Groups further assessed according to neck length, A (≥4 and <7 mm) and B (≥7 and ≤10 mm). The main outcomes analyzed were technical success, freedom from type Ia endoleaks (TIaELs), sac size increase, all-cause and aneurysm-related mortality. RESULTS: Seventy-six patients were included in the study, 17 fell into Group A and 59 into Group B. Median follow-up for the cohort was 40.5 (interquartile range 12-61) months. A median of 6 (interquartile range 3) EndoAnchors were deployed in each subject. Technical success was 86.8% for the total group, 82.4% and 88.1% (P = 0.534) for Groups A and B respectively. Six out of 10 (60%) of TIaELs at the completion angiographies showed spontaneous resolution. Cumulative freedom from TIaEL at 3 and 5 years for the total group was 89% and 84% respectively; this was 93% and 74% for Group A and 88% at both intervals in Group B (P = 0.545). In total, there were 7 (9.2%) patients presenting with TIaELs over the entire study period. Two (11.8%) in Group A and 5 (8.5%) in Group B (P = 0.679). There were more patients with sac regression in Group B (Group A = 6-35.3% vs. Group B = 34-57.6%, P = 0.230) with no statistical significance. All-cause mortality was 19 (25%) patients, with no difference (4-23.5% vs. 15-25.4%, P = 0.874) between groups; whereas aneurysm-related mortality occurred in 1 patient from Group A and 3 from Group B. CONCLUSIONS: This study demonstrates reasonable outcomes for patients with short-necked AAAs treated by endosutured aneurysm repair in terms of TIaELs up to 5-year follow-up. EndoAnchor use should be judiciously evaluated in short necks and may be a reasonable option when anatomical constraints are encountered, mainly for those with 7-10 mm neck lengths. Shorter neck length aspects, as indicated by the results from Group A, may be an alternative when no other options are available or feasible.

2.
Front Oncol ; 14: 1304691, 2024.
Article in English | MEDLINE | ID: mdl-38344207

ABSTRACT

Background: Tumor heterogeneity is one of the key factors leading to chemo-resistance relapse. It remains unknown how resistant cancer cells influence sensitive cells during cohabitation and growth within a heterogenous tumors. The goal of our study was to identify driving factors that mediate the interactions between resistant and sensitive cancer cells and to determine the effects of cohabitation on both phenotypes. Methods: We used isogenic ovarian cancer (OC) cell lines pairs, sensitive and resistant to platinum: OVCAR5 vs. OVCAR5 CisR and PE01 vs. PE04, respectively, to perform long term direct culture and to study the phenotypical changes of the interaction of these cells. Results: Long term direct co-culture of sensitive and resistant OC cells promoted proliferation (p < 0.001) of sensitive cells and increased the proportion of cells in the G1 and S cell cycle phase in both PE01 and OVCAR5 cells. Direct co-culture led to a decrease in the IC50 to platinum in the cisplatin-sensitive cells (5.92 µM to 2.79 µM for PE01, and from 2.05 µM to 1.51 µM for OVCAR5). RNAseq analysis of co-cultured cells showed enrichment of Cell Cycle Control, Cyclins and Cell Cycle Regulation pathways. The transcription factor E2F1 was predicted as the main effector responsible for the transcriptomic changes in sensitive cells. Western blot and qRT-PCR confirmed upregulation of E2F1 in co-cultured vs monoculture. Furthermore, an E2F1 inhibitor reverted the increase in proliferation rate induced by co-culture to baseline levels. Conclusion: Our data suggest that long term cohabitation of chemo-sensitive and -resistant cancer cells drive sensitive cells to a higher proliferative state, more responsive to platinum. Our results reveal an unexpected effect caused by direct interactions between cancer cells with different proliferative rates and levels of platinum resistance, modelling competition between cells in heterogeneous tumors.

4.
J Med Chem ; 66(14): 9445-9465, 2023 07 27.
Article in English | MEDLINE | ID: mdl-37449845

ABSTRACT

Tissue transglutaminase (TG2) is a multifunctional enzyme involved in the cross-linking of extracellular matrix proteins, formation of complexes with fibronectin (FN) and integrins, and GTP hydrolysis. TG2 is activated in several pathological conditions, including cancer. We recently described a novel series of ligands that bind to TG2 and inhibit its interaction with FN. Because TG2 acts via multiple mechanisms, we set out to pursue a targeted protein degradation strategy to abolish TG2's myriad functions. Here, we report the synthesis and characterization of a series of VHL-based degraders that reduce TG2 in ovarian cancer cells in a proteasome-dependent manner. Degradation of TG2 resulted in significantly reduced cancer cell adhesion and migration in vitro in scratch-wound and migration assays. These results strongly indicate that further development of more potent and in vivo efficient TG2 degraders could be a new strategy for reducing the dissemination of ovarian and other cancers.


Subject(s)
Protein Glutamine gamma Glutamyltransferase 2 , Transglutaminases , Female , Humans , Proteolysis Targeting Chimera , GTP-Binding Proteins/metabolism , Cell Adhesion
6.
Angiol. (Barcelona) ; 75(2): 78-84, Mar-Abr. 2023. tab
Article in Spanish | IBECS | ID: ibc-219057

ABSTRACT

La isquemia intestinal asocia una elevada mortalidad debida principalmente a un retraso en el diagnóstico. Sibien el angio tC es una herramienta sensible y específica, suele transcurrir demasiado tiempo hasta su realizacióndebido a una presentación clínica poco específica. en este tiempo la isquemia intestinal puede progresar a estadiosirreversibles con afectación sistémica. La obtención de biomarcadores precisos y de elevación precoz acortaría eltiempo diagnóstico de esta patología, lo que disminuiría su mortalidad asociada. Se sabe que las moléculas usadastradicionalmente, entre ellas el lactato, no tienen buena capacidad diagnóstica. no obstante, se ha observado unaelevada sensibilidad con el uso del esteroisómero D del lactato y la procalcitonina para detectar colitis isquémicatras cirugía de aorta, al tiempo que se recomienda valorar los niveles de dímero D para descartar isquemia mesen-térica aguda en pacientes con dolor abdominal. Otras moléculas con un potencial rendimiento diagnóstico sonla proteína ligadora de ácidos grasos intestinales (I-FaBp) y el péptido similar al glucagón de tipo 1 (GLp-1), aúnen investigación.(AU)


Intestinal ischemia associates high mortality rates, mainly due to a delay in diagnosis. although computed tomog-raphy angiography (Cta) remains a sensitive and specifi c tool, it usually takes quite long until it is done, due to anunspecific clinical presentation. In this time lapse, intestinal ischemia may progress to an irreversible stage withsigns of systemic failure. the acquisition of precise and early detection biomarkers for the disease would shortenthe time to diagnosis and hence its associated mortality. It is acknowledged that those molecules which have beenclassically used-lactate amongst them-do not have a proper diagnostic capacity. nevertheless, the D stereoisomerof lactate and procalcitonin have shown high sensitivity for detection of ischemic colitis after open aortic surgery,while D-dimer measurement is recommended to rule out acute mesenteric ischemia in patients with abdominalpain. Other molecules with a potential for diagnostic yield are intestinal fatty acid binding protein (i-FaBp) andglucagon-like peptide-1 (GLp-1), still under investigation.(AU)


Subject(s)
Humans , Biomarkers , Mortality , Intestines/injuries , Colitis, Ischemic , Mesenteric Ischemia , Cardiovascular Diseases , Blood Vessels
7.
Mol Cancer Ther ; 22(3): 393-405, 2023 03 02.
Article in English | MEDLINE | ID: mdl-36622754

ABSTRACT

Development of resistance to platinum (Pt) in ovarian cancer remains a major clinical challenge. Here we focused on identifying epitranscriptomic modifications linked to Pt resistance. Fat mass and obesity-associated protein (FTO) is a N6-methyladenosine (m6A) RNA demethylase that we recently described as a tumor suppressor in ovarian cancer. We hypothesized that FTO-induced removal of m6A marks regulates the cellular response of ovarian cancer cells to Pt and is linked to the development of resistance. To study the involvement of FTO in the cellular response to Pt, we used ovarian cancer cells in which FTO was knocked down via short hairpin RNA or overexpressed and Pt-resistant (Pt-R) models derived through repeated cycles of exposure to Pt. We found that FTO was significantly downregulated in Pt-R versus sensitive ovarian cancer cells. Forced expression of FTO, but not of mutant FTO, increased sensitivity to Pt in vitro and in vivo (P < 0.05). Increased numbers of γ-H2AX foci, measuring DNA double-strand breaks, and increased apoptosis were observed after exposure to Pt in FTO-overexpressing versus control cells. Through integrated RNA sequencing and MeRIP sequencing, we identified and validated the enzyme nicotinamide N-methyltransferase (NNMT), as a new FTO target linked to Pt response. NNMT was upregulated and demethylated in FTO-overexpressing cells. Treatment with an NNMT inhibitor or NNMT knockdown restored sensitivity to Pt in FTO-overexpressing cells. Our results support a new function for FTO-dependent m6A RNA modifications in regulating the response to Pt through NNMT, a newly identified RNA methylated gene target.


Subject(s)
Ovarian Neoplasms , Platinum , RNA , Female , Humans , Adenosine/chemistry , Alpha-Ketoglutarate-Dependent Dioxygenase FTO/genetics , Alpha-Ketoglutarate-Dependent Dioxygenase FTO/metabolism , Nicotinamide N-Methyltransferase , Ovarian Neoplasms/drug therapy , Ovarian Neoplasms/metabolism , Platinum/pharmacology , Platinum/therapeutic use , RNA/chemistry , RNA/metabolism
8.
Vascular ; 31(3): 455-462, 2023 Jun.
Article in English | MEDLINE | ID: mdl-35225085

ABSTRACT

OBJECTIVE: To describe mid-term outcomes of the use of EndoAnchors as an adjunct for arch and thoracic endovascular aortic repair (TEVAR). METHODS: A retrospective multicentre series from nine centres using the Heli-FX EndoAnchor System (Medtronic Inc, Minneapolis, USA) at TEVAR over May 2014-May 2019 is presented. The study is registered at ClinicalTrials.gov with number NCT04100499. The primary outcome was freedom from Type I endoleak at EndoAnchors deployments; secondary outcomes included evaluation of aortic wall penetration (AWP) at first computed tomography scan, EndoAnchor-related issues and mortality. RESULTS: 54 high-risk patients (35 males/19 females, age 73 ± 11 years) with arch, thoracic and thoracoabdominal aneurysmal disease (3 chronic post-dissection and one patch pseudoaneurysm), with a mean neck length 19.7 ± 6.6 mm that were treated with multiple hybrid and endovascular techniques were included. A total of 329 EndoAnchors were used with a mean of 6.1 ± 2.5 per patient. Overall adequate AWP was 86%, whereas arch (Ishimaru's zones 0-2) deployments achieved 80.6% when compared to 87.3% in descending thoracic aorta (dTA); although there was no statistical significance. Freedom from type I endoleaks was 88% at 2 year follow-up, due to 4 type IA endoleaks, two of them successfully treated, one with conservative treatment due to complexity of repair and remaining patient died 1 year later due to endograft infection. There were reported five EndoAnchor-related issues; four losses and one renal stent-graft was crushed due to catheter deflection solved with balloon reinflation. None of the losses had clinical significance. Overall mortality is described for 7 (9.5%) patients, one of them aneurysm-related. CONCLUSIONS: The adjunctive use of EndoAnchors in TEVAR and complex TEVAR procedures achieved acceptable outcomes at midterm in a high-risk series with hostile seal zones. Still, they should be still judiciously used as there is lack of data to suggest a more liberal use; therefore, the landing zone should not be compromised in favour of their use.


Subject(s)
Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Male , Female , Humans , Middle Aged , Aged , Aged, 80 and over , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Aneurysm Repair , Endoleak/diagnostic imaging , Endoleak/etiology , Endoleak/surgery , Treatment Outcome , Endovascular Procedures/adverse effects , Retrospective Studies , Risk Factors , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/etiology
9.
J Endovasc Ther ; 30(3): 449-460, 2023 06.
Article in English | MEDLINE | ID: mdl-35297713

ABSTRACT

PURPOSE: The purpose of the study was to provide a consensus definition of the infrarenal sealing zone and develop an algorithm to determine when and if adjunctive procedure(s) or reintervention should be considered in managing patients undergoing endovascular aortic repair (EVAR) for infrarenal abdominal aortic aneurysm (AAA). METHODS: A European Advisory Board (AB), made up of 11 vascular surgeons with expertise in EVAR for AAA, was assembled to share their opinion regarding the definition of preoperative and postoperative infrarenal sealing zone. Information on their current clinical practice and level of agreement on proposed reintervention paths was used to develop an algorithm. The process included 2 virtual meetings and 2 rounds of online surveys completed by the AB (Delphi method). Consensus was defined as reached when ≥ 8 of 11 (73%) respondents agreed or were neutral. RESULTS: The AB reached complete consensus on definitions and measurement of the pre-EVAR target anticipated sealing zone (TASZ) and the post-EVAR real achieved sealing zone (RASZ), namely, the shortest length between the proximal and distal reference points as defined by the AB, in case of patients with challenging anatomies. Also, agreement was achieved on a list of 4 anatomic parameters and 3 prosthesis-/procedure-related parameters, considered to have the most significant impact on preoperative and postoperative sealing zones. Furthermore, the agreement was reached that in the presence of visible neck-related complications, both adjunctive procedure(s) and reintervention should be contemplated (100% consensus). In addition, adjunctive procedure(s) or reintervention can be considered in the following cases (% consensus): insufficient sealing zone on completion imaging (91%) or on the first postoperative computed tomography (CT) scan (91%), suboptimal sealing zone on completion imaging (73%) or postoperative CT scan (82%), and negative evolution of the actual sealing zone over time (91%), even in the absence of visible complications. CONCLUSIONS: AB members agreed on definitions of the pre- and post-EVAR infrarenal sealing zone, as well as factors of influence. Furthermore, a clinical decision algorithm was proposed to determine the timing and necessity of adjunctive procedure(s) and reinterventions.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/methods , Endovascular Aneurysm Repair , Delphi Technique , Consensus , Expert Testimony , Treatment Outcome , Endovascular Procedures/adverse effects , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Risk Factors , Retrospective Studies , Blood Vessel Prosthesis
10.
Mol Cancer Res ; 21(2): 140-154, 2023 02 01.
Article in English | MEDLINE | ID: mdl-36318113

ABSTRACT

Cancer stem cells (CSC) represent a population of cancer cells responsible for tumor initiation, chemoresistance, and metastasis. Here, we identified the H3K79 methyltransferase disruptor of telomeric silencing-1-like (DOT1L) as a critical regulator of self-renewal and tumor initiation in ovarian CSCs. DOT1 L was upregulated in ovarian CSCs versus non-CSCs. shRNA-mediated DOT1 L knockdown decreased the aldehyde dehydrogenase (ALDH)+ cell population, impaired the tumor initiation capacity (TIC) of ovarian CSCs, and blocked the expression of stemness-associated genes. Inhibition of DOT1L's methyltransferase activity by the small-molecule inhibitor (DOT1Li) EPZ-5676 also effectively targeted ovarian CSCs. Integrated RNA-sequencing analyses of ovarian cancer cells in which DOT1 L was knocked down versus control cells and of ovarian CSCs versus non-CSCs, identified Wnt signaling as a shared pathway deregulated in both CSCs and in DOT1L-deficient ovarian cancer cells. ß-catenin, a key transcription factor regulated by Wnt, was downregulated in ovarian cancer cells in which DOT1 L was knocked down and upregulated in DOT1 L overexpressing ovarian cancer cells. Chromatin immunoprecipitation (ChIP) revealed enrichment of the H3K79Me3 mark at the ß-catenin promoter, suggesting that its transcription is regulated by DOT1L. Our results suggest that DOT1 L is critical for the self-renewal and TIC of ovarian CSCs by regulating ß-catenin signaling. Targeting DOT1 L in ovarian cancer could be a new strategy to eliminate CSCs. IMPLICATIONS: This study found that the histone methyltransferase DOT1 L regulates the self-renewal and tumor initiation capacity of ovarian CSCs and suggests DOT1 L as a new cancer target.


Subject(s)
Ovarian Neoplasms , beta Catenin , Humans , Female , beta Catenin/genetics , beta Catenin/metabolism , Cell Line, Tumor , Cell Proliferation , Neoplastic Stem Cells/metabolism , Cell Transformation, Neoplastic/metabolism , Wnt Signaling Pathway , Ovarian Neoplasms/pathology
11.
J Endovasc Ther ; : 15266028221127839, 2022 Oct 10.
Article in English | MEDLINE | ID: mdl-36214450

ABSTRACT

PURPOSE: To analyze sac evolution patterns in matched patients with hostile neck anatomy (HNA) treated with standard endovascular aneurysm repair (sEVAR) and endosutured aneurysm repair (ESAR). METHODS: Observational retrospective study using prospectively collected data between June 2010 and December 2019. ESAR group data were extracted from the primary arm of the PERU registry with an assigned identifier (NCT04100499) at 8 centers and those from the sEVAR came from 4 centers. Suitability for inclusion required: no proximal endograft adjuncts (besides EndoAnchor use), ≤15 mm neck length and minimum of 12-months follow-up imaging. Bubble-shaped neck (noncylindrical short neck with discontinuous seal) aspect was analyzed. Both groups were analyzed using propensity score matching (PSM) for aortic neck length, width, angulation, and device fixation type. Main outcome assessed was sac evolution patterns (sac expansion and regression were defined as >5mm increase or decrease, of the maximum sac diameter respectively; all AAAs within this ±5 mm range in diameter change were considered stable) and secondary outcomes were type-Ia endoleaks; other endoleaks and mortality. A power analysis calculation >80% was confirmed for sac regression evaluation. RESULTS: After exclusions, PSM resulted in 96 ESAR and 96 sEVAR patients. Mean imaging follow-up (months) was 44.4±21.3 versus 43.0±19.6 (p=0.643), respectively. The overall number of patients achieving sac regression was higher in the ESAR group (n=57, 59.4% vs n=31, 32.3%; p<0.001) and the cumulative sac regression achieved at 5 years was 65% versus 38% (p=0.003) in favor of the ESAR group. There were no statistically significant differences in type-Ia endoleak and/or other endoleaks. Univariate analysis for sac regression patients in the sEVAR and ESAR group individually showed the bubble-shape neck as a predictor of sac regression failure. There were no statistical differences in overall and aneurysm-related mortality. CONCLUSION: Endosutured aneurysm repair provided improved rates of sac regression for patients with AAA and HNA when compared with sEVAR at midterm and up to 5 years, despite similar rates of type-Ia endoleaks, and the need to consider some important limitations. The presence of bubble-shaped neck was a predictor of sac regression failure for both groups equally. CLINICAL IMPACT: The use of EndoAnchors aids and improves EVAR treatment in hostile neck anatomies by an increased rate of sac regression when compared to EVAR treatment alone in up to 5 year analysis. Moreover, a trend to reduced number of type Ia endoleaks is also achieved, although not significant in the present study. This data, adds to current and growing evidence on the usefulness of EndoAnchors for AAA endovascular treatment.

12.
Vascular ; 30(1): 27-37, 2022 Feb.
Article in English | MEDLINE | ID: mdl-33568007

ABSTRACT

OBJECTIVES: We aim to describe real-world outcomes from multicenter data about the efficacy of adjunct Heli-FX EndoAnchor usage in preventing or repairing failures during infrarenal endovascular aneurysm repair (EVAR), so-called EndoSutured-aneurysm-repair (ESAR). METHODS: The current study has been assigned an identifier (NCT04100499) at the US National Library of Medicine (https://ClinicalTrials.gov). It is an observational retrospective study of prospectively collected data from seven vascular surgery departments between June 2010 and December 2019. Patients included in the ANCHOR registry were excluded from this analysis. The decision for the use of EndoAnchors was made by the treating surgeon or multidisciplinary aortic committee according to each center's practice. Follow-up imaging was scheduled according to each center's protocol, which necessarily included either abdominal ultrasound or radiography or computed tomographic scan imaging. The main outcomes analyzed were technical success, freedom from type Ia endoleaks (IaEL), all-cause and aneurysm-related mortality, and sac variation and trends evaluated for those with at least six months imaging follow-up. RESULTS: Two hundred and seventy-five patients underwent ESAR in participating centers during the study period. After exclusions, 221 patients (184 males, 37 females, mean age 75 ± 8.3 years) were finally included for analysis. Median follow-up for the cohort was 27 (interquartile range 12-48) months. A median 6 (interquartile range 3) EndoAnchors were deployed at ESAR, 175 (79%) procedures were primary and 46 (21%) revision cases, 40 associated with type IaEL. Technical success at operation (initial), 30-day, and overall success were 89, 95.5, and 96.8%, respectively; the 30-day success was higher due to those with subsequent spontaneous proximal endoleak seal. At two years, freedom from type IaEL was 94% for the whole series; 96% and 86% for the primary and revision groups, respectively; whereas freedom from all-cause mortality, aneurysm-related mortality, and reintervention was 89%, 98%, and 87%, respectively. Sac evolution pre-ESAR was 66 ± 15.1 vs. post ESAR 61 ± 17.5 (p < 0.001) and for 180 patients with at least six-month follow-up, 92.2% of them being in a stable (51%) or regression (41%) situation. CONCLUSIONS: This real-world registry demonstrates that adjunct EndoAnchor usage at EVAR achieves high rates of freedom from type IaEL at mid-term including in a high number of patients with hostile neck anatomy, with positive trends in sac-size evolution. Further data with longer follow-up may help to establish EndoAnchor usage as a routine adjunct to EVAR, especially in hostile necks.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Physicians , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/complications , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis/adverse effects , Blood Vessel Prosthesis Implantation/adverse effects , Endoleak/diagnostic imaging , Endoleak/etiology , Endoleak/prevention & control , Endovascular Procedures/adverse effects , Endovascular Procedures/methods , Female , Humans , Male , Peru , Registries , Retrospective Studies , Treatment Outcome
13.
J Endovasc Ther ; 28(6): 871-877, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34190634

ABSTRACT

PURPOSE: To describe the use of large-diameter balloon-expandable stent-grafts (BeGraft aortic stent-graft, Bentley InnoMed GmbH, Hechingen, Germany) in the treatment of infrarenal penetrating aortic ulcer (iPAU). MATERIALS AND METHODS: Retrospective analysis of patients undergoing endovascular treatment with the BeGraft aortic stent-graft in 8 European centers from January 2017 to October 2020. Demographics, perioperative data, and midterm outcomes were collected. Endpoints of the study were technical feasibility, early mortality, and morbidity. RESULTS: A total of 40 patients were included. The mean age was 73.9±7.05 years and 63.2% were male. Indications for treatment included size and morphology (65%), presence of symptoms (29.5%), and contained ruptures (5.5%). Urgent treatment was performed in 5% of cases. Technical success was 97.5%. Median operation time was 58 minutes (19-170 minutes), with 27.5% of patients having additional procedures during the main intervention (1 additional repair with a C-TAG (W.L. Gore & Associates, Inc, Flagstaff, AZ, USA) thoracic endoprosthesis, 5 covered endovascular reconstruction of aortic bifurcation procedures, 3 extensions with proximal cuffs, and 2 percutaneous angioplasties of the common iliac arteries). Percutaneous femoral access was used in 72.5%, while groin cut-down was performed in 27.5%. Repair was successful with only 1 stent in 45% of cases, while 37.5% required 2 stents and nearly 17.5% required 3/4 stent-grafts. The 30-day mortality was 0%, with a 2.5% reintervention rate (1 patient required evacuation of an intra-abdominal hematoma). Median follow-up was 13.9 months (2-39 months), during which no vascular-related reinterventions or deaths were reported. In 4 patients, a type II endoleak was observed. No cases of graft migration, thrombosis, or stent-fracture were observed. CONCLUSIONS: The treatment of iPAU with the BeGraft aortic stent-graft in a selective patient group is feasible with low rate of perioperative morbidity and mortality. Balloon-expandable stent-grafts offer the option to repair iPAUs with a shorter coverage of the aorta using low-profile sheath, that enables treatment in the presence of calcified access vessels and small diameter aortic bifurcations.


Subject(s)
Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aged , Aged, 80 and over , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Humans , Male , Prosthesis Design , Retrospective Studies , Stents , Treatment Outcome , Ulcer/diagnostic imaging , Ulcer/surgery
15.
Ann Thorac Surg ; 111(6): e399-e401, 2021 06.
Article in English | MEDLINE | ID: mdl-33253673

ABSTRACT

Mediastinoscopy is considered a safe technique to biopsy mediastinal lesions. Among its complications, vascular ones are the most common. We present a rare case of intimal dissection of the innominate artery during the performance of a mediastinoscopy that caused an ischemic attack from which the patient recovered completely without long-term sequelae. We analyze the possible causes and risk factors of this complication.


Subject(s)
Brachiocephalic Trunk , Intraoperative Complications/etiology , Mediastinoscopy/adverse effects , Aged , Brachiocephalic Trunk/diagnostic imaging , Female , Humans , Intraoperative Complications/diagnostic imaging , Mediastinoscopy/methods , Tomography, X-Ray Computed , Video-Assisted Surgery
16.
Int J Cardiol ; 331: 63-68, 2021 05 15.
Article in English | MEDLINE | ID: mdl-33164839

ABSTRACT

BACKGROUND: The aim of the present study was to evaluate early results of thoracic endovascular aortic repair (TEVAR) using the Valiant Navion™ stent graft in a "real-world" scenario. METHODS: All patients who underwent TEVAR with the Valiant Navion™ endograft between November 2018 and November 2019 were included in this retrospective multicenter study (six European centers). The primary endpoints were technical success, incidence of major adverse events (MAEs), access failure, deployment failure, deployment accuracy, and rate of intraoperative endoleaks (ELs). RESULTS: One hundred-sixteen patients with varying thoracic aortic diseases were included. Eighteen patients (15.5%) were treated for an off-label condition. The technical success rate was 100%, without any access or deployment failures. The proximal and distal deployment accuracy rates were 99.1% and 97.4%, respectively. There were no intraoperative MAEs, including death. Two (1.7%) type Ib ELs were detected at the first postoperative CTA, all of which were in off-label procedures and related to the short length of the sealing neck. No type III ELs were detected. The median hospitalization time was 8 days (IQR 4-12), including a median intensive care unit stay of 1 day (IQR 1-2). The in-hospital mortality rate was 4.3%. At a median follow-up time of 98 days (IQR 39-187), there were no aortic-related mortalities or new onset of endoleaks. CONCLUSION: Our initial experience with the Valiant Navion™ endograft in a wide variety of aortic diseases showed safe early outcomes, especially for on-label procedures.


Subject(s)
Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Humans , Prosthesis Design , Retrospective Studies , Stents , Treatment Outcome
18.
J Endovasc Ther ; 28(2): 295-299, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33070677

ABSTRACT

PURPOSE: To describe steps related to intraoperative C-arm orientations that can be taken during preoperative planning of thoracic stent-graft repair to facilitate the deployment of EndoAnchors in the distal aortic arch. TECHNIQUE: Previous experience from transcatheter aortic valve implantation (TAVI) may be helpful in addressing issues with C-arm orientation. In TAVI, preoperative computed tomography (CT) images are routinely obtained to generate a patient-specific curve that represents a virtually complete rotation of the C-arm perpendicular to the annulus. The curve clearly demonstrates that each adjustment in cranial or caudal view needs parallax correction in the left or right anterior oblique direction to remain perpendicular, and vice versa. This experience can be translated to the preoperative planning of EndoAnchor use in the aortic arch. By placing markers along the circumference of the proximal landing zone of the preoperative CT scan, the required C-arm orientations can be determined for each marker. CONCLUSION: Determining the optimal C-arm orientation during preoperative planning will facilitate successful EndoAnchor deployment and may contribute to improved durability of endovascular repair in hostile necks in the aortic arch.


Subject(s)
Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis , Endoleak/surgery , Humans , Prosthesis Design , Stents , Treatment Outcome
19.
Vascular ; 29(1): 148-149, 2021 02.
Article in English | MEDLINE | ID: mdl-32631132
20.
Ann Vasc Surg ; 70: 444-448, 2021 Jan.
Article in English | MEDLINE | ID: mdl-32592846

ABSTRACT

BACKGROUND: The presence of sac enlargement after abdominal aortic aneurysm (AAA) open repair, a condition usually called perigraft seroma (PGS), nearly always has a benign behavior. Some theories implicated for PGS formation include coagulation abnormalities, fibroblast inhibition, low-grade infection, or improper graft handling. METHODS: This is a retrospective study including patients treated for AAA in 2 academic vascular surgery departments from 2007 to 2014, where 1 center preferably used polytetrafluoroethylene (PTFE) grafts whereas the preference of other center was mostly Dacron graft. The definition of PGS was conceived as a fluid collection around the graft on CT scan imaging with a radiodensity ≤25 Hounsfield units, reaching at least 30 mm in diameter and beyond the third postoperative month. Analysis was performed between patients with and without PGS. RESULTS: Seventy-eight patients met the inclusion criteria: 42 received Dacron and 36 PTFE grafts. Twenty-three (29.5%) patients accomplished the PGS diagnosis. Having a PTFE graft was the strongest factor for PGS formation on multivariate analysis. The medium seroma size was 42 mm (range, 30-90.6 mm) and the mean time from AAA repair to PGS detection was 26 months (range, 4-106 months). Three patients of the 23 with PGS required surgical repair, all of them were successfully treated: 2 by endovascular means and the remaining with explantation and Dacron reconstruction. CONCLUSIONS: PGS formation is not an unusual complication after open reconstructions for AAA treatment. This is especially true for PTFE grafts, and thus, closer follow-up is warranted if using this material. Treatment is clearly needed when symptoms appear; however, preventive strategies with either endovascular relining or reopen reconstructions require an individual approach counterbalancing benefits versus risk of the procedures.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis/adverse effects , Polytetrafluoroethylene/adverse effects , Seroma/etiology , Aged , Aortic Aneurysm, Abdominal/diagnostic imaging , Female , Humans , Male , Middle Aged , Polyethylene Terephthalates/adverse effects , Prosthesis Design , Retrospective Studies , Risk Assessment , Risk Factors , Seroma/diagnostic imaging , Spain , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...