Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Publication year range
1.
Gac Med Mex ; 159(3): 210-218, 2023.
Article in English | MEDLINE | ID: mdl-37494706

ABSTRACT

BACKGROUND: Heart valve replacement surgery with mechanical or biological prostheses entails a risk of thromboembolism and bleeding complications. OBJECTIVE: To determine the complications related to complementary anticoagulation therapy and the probability of risk. METHODS: One-hundred and sixty-three patients who underwent heart valve replacement between 2002 and 2016 with either mechanical or biological prostheses, and who received vitamin K antagonists after hospital discharge, were studied. Anticoagulation therapy was categorized into optimal and non-optimal according to INR values prior to the development of complications. Patients with comorbidities and other risk factors for thrombosis and/or bleeding were excluded. RESULTS: In total, 68.7 % of patients received mechanical prostheses, and 31.3 %, biological prostheses (p ≤ 0.001); 25.2 % experienced the complications that motivated the study (p ≤ 0.001), which were hemorrhagic in 48.8 %, thromboembolic in 26.8 %, and of both types in 24.4 % (relative risk = 4.229). Among the patients with complications, 95.1 % received mechanical prostheses, and 4.9 %, biological (p = 0.005); non-optimal INR was identified in 49.7 % (p ≤ 0.001). CONCLUSIONS: Given the high risk of thromboembolic and hemorrhagic complications, valve prostheses must be carefully chosen, and care priorities should include prevention and follow-up, especially in those patients who require anticoagulation therapy.


ANTECEDENTES: El reemplazo valvular por prótesis mecánicas o biológicas implica riesgo de tromboembolismo y complicaciones hemorrágicas. OBJETIVO: Determinar las complicaciones relacionadas con la terapia de anticoagulación complementaria y la probabilidad de riesgo en pacientes portadores de prótesis valvulares del corazón. MÉTODOS: Se estudiaron 163 pacientes entre 2002 y 2016, portadores de prótesis mecánicas y biológicas, quienes recibieron antagonistas de la vitamina K posterior al egreso hospitalario. La terapia de anticoagulación se categorizó en óptima y no óptima conforme a los valores de INR previos a las complicaciones. Fueron excluidos los pacientes con comorbilidades y otros factores de riesgo de trombosis y/o sangrado. RESULTADOS: a 68.7 % de los pacientes se les colocó prótesis mecánica y a 31.3 %, biológica (p ≤ 0.001); 25.2 % presentó las complicaciones motivo de estudio (p ≤ 0.001), hemorrágicas en 48.8 %, tromboembólicas en 26.8 % y de ambos tipos en 24.4 % (riesgo relativo = 4.229); a 95.1 % de los pacientes con complicaciones se les colocó prótesis mecánica y a 4.9 %, biológica (p = 0.005); 49.7 % presentó INR no óptimo (p ≤ 0.001). CONCLUSIONES: Ante riesgo alto de complicaciones tromboembólicas y hemorrágicas, la elección de las prótesis valvulares, la prevención y el seguimiento son prioridades, principalmente en quienes requieren terapia de anticoagulación.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Thromboembolism , Humans , Tertiary Care Centers , Thromboembolism/epidemiology , Thromboembolism/etiology , Thromboembolism/prevention & control , Heart Valve Prosthesis/adverse effects , Anticoagulants/therapeutic use , Hemorrhage/epidemiology , Hemorrhage/etiology , Heart Valves , Heart Valve Prosthesis Implantation/adverse effects
2.
Gac. méd. Méx ; 159(3): 215-223, may.-jun. 2023. tab
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1448279

ABSTRACT

Resumen Antecedentes: El reemplazo valvular por prótesis mecánicas o biológicas implica riesgo de tromboembolismo y complicaciones hemorrágicas. Objetivo: Determinar las complicaciones relacionadas con la terapia de anticoagulación complementaria y la probabilidad de riesgo en pacientes portadores de prótesis valvulares del corazón. Métodos: Se estudiaron 163 pacientes entre 2002 y 2016, portadores de prótesis mecánicas y biológicas, quienes recibieron antagonistas de la vitamina K posterior al egreso hospitalario. La terapia de anticoagulación se categorizó en óptima y no óptima conforme a los valores de INR previos a las complicaciones. Fueron excluidos los pacientes con comorbilidades y otros factores de riesgo de trombosis y/o sangrado. Resultados: a 68.7 % de los pacientes se les colocó prótesis mecánica y a 31.3 %, biológica (p ≤ 0.001); 25.2 % presentó las complicaciones motivo de estudio (p ≤ 0.001), hemorrágicas en 48.8 %, tromboembólicas en 26.8 % y de ambos tipos en 24.4 % (riesgo relativo = 4.229); a 95.1 % de los pacientes con complicaciones se les colocó prótesis mecánica y a 4.9 %, biológica (p = 0.005); 49.7 % presentó INR no óptimo (p ≤ 0.001). Conclusiones: Ante riesgo alto de complicaciones tromboembólicas y hemorrágicas, la elección de las prótesis valvulares, la prevención y el seguimiento son prioridades, principalmente en quienes requieren terapia de anticoagulación.


Abstract Background: Heart valve replacement surgery with mechanical or biological prostheses entails a risk of thromboembolism and bleeding complications. Objective: To determine the complications related to complementary anticoagulation therapy and the probability of risk. Methods: One-hundred and sixty-three patients who underwent heart valve replacement between 2002 and 2016 with either mechanical or biological prostheses, and who received vitamin K antagonists after hospital discharge, were studied. Anticoagulation therapy was categorized into optimal and non-optimal according to INR values prior to the development of complications. Patients with comorbidities and other risk factors for thrombosis and/or bleeding were excluded. Results: In total, 68.7 % of patients received mechanical prostheses, and 31.3 %, biological prostheses (p ≤ 0.001); 25.2 % experienced the complications that motivated the study (p ≤ 0.001), which were hemorrhagic in 48.8 %, thromboembolic in 26.8 %, and of both types in 24.4 % (relative risk = 4.229). Among the patients with complications, 95.1 % received mechanical prostheses, and 4.9 %, biological (p = 0.005); non-optimal INR was identified in 49.7 % (p ≤ 0.001). Conclusions: Given the high risk of thromboembolic and hemorrhagic complications, valve prostheses must be carefully chosen, and care priorities should include prevention and follow-up, especially in those patients who require anticoagulation therapy.

SELECTION OF CITATIONS
SEARCH DETAIL
...