Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Head Neck ; 45(4): 993-1005, 2023 04.
Article in English | MEDLINE | ID: mdl-36811302

ABSTRACT

BACKGROUND: To improve the understanding of the thermodynamics and performance of small passive hygroscopic Heat and Moisture Exchangers (HMEs), a computer model simulating HME function is required. METHODS: We developed a numerical HME model to calculate the HME's water and heat exchange. The model was tuned and verified with experimental data and validated by applying it to HME design variations. RESULTS: Verification of the model's results to the experimental data shows that the tuned model yields reliable results. The mass of the core, which determines the HME's total heat capacity, is the most important parameter influencing the performance of passive HMEs. CONCLUSIONS: Increasing the HME's diameter is an effective way to improve an HME, as it yields higher performance and lowers breathing resistance. HMEs intended for use in warm or dry climates should contain more and those for use in cold humid climates should contain less hygroscopic salt.


Subject(s)
Hot Temperature , Respiration, Artificial , Humans , Humidity
2.
Head Neck ; 43(4): 1073-1087, 2021 04.
Article in English | MEDLINE | ID: mdl-33615610

ABSTRACT

BACKGROUND: Due to the heat and moisture exchanger's (HME) breathing resistance, laryngectomized patients cannot always use an (optimal) HME during physical exercise. We propose a novel HME cassette concept with adjustable "bypass," to provide adjustment between different breathing resistances within one device. METHODS: Under standardized conditions, the resistance and humidification performance of a high resistance/high humidification HME (XM) foam in a cassette with and without bypass were compared to a lower resistance/lesser humidification HME (XF) foam in a closed cassette. RESULTS: With a bypass in the cassette, the resistance and humidification performance of XM foam were similar to those of XF foam in the closed cassette. Compared to XM foam in the closed cassette, introducing the bypass resulted in a 40% resistance decrease, whereas humidification performance was maintained at 80% of the original value. CONCLUSIONS: This HME cassette prototype allows adjustment between substantially different resistances while maintaining appropriate humidification performances.


Subject(s)
Hot Temperature , Laryngectomy , Humans , Humidity
SELECTION OF CITATIONS
SEARCH DETAIL
...