Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 133
Filter
1.
Article in English, Spanish | MEDLINE | ID: mdl-38697283

ABSTRACT

INTRODUCTION AND OBJECTIVES: The multiparametric implantable cardioverter-defibrillator HeartLogic index has proven to be a sensitive and timely predictor of impending heart failure (HF) decompensation. We evaluated the impact of a standardized follow-up protocol implemented by nursing staff and based on remote management of alerts. METHODS: The algorithm was activated in HF patients at 19 Spanish centers. Transmitted data were analyzed remotely, and patients were contacted by telephone if alerts were issued. Clinical actions were implemented remotely or through outpatient visits. The primary endpoint consisted of HF hospitalizations or death. Secondary endpoints were HF outpatient visits. We compared the 12-month periods before and after the adoption of the protocol. RESULTS: We analyzed 392 patients (aged 69±10 years, 76% male, 50% ischemic cardiomyopathy) with implantable cardioverter-defibrillators (20%) or cardiac resynchronization therapy defibrillators (80%). The primary endpoint occurred 151 times in 86 (22%) patients during the 12 months before the adoption of the protocol, and 69 times in 45 (11%) patients (P<.001) during the 12 months after its adoption. The mean number of hospitalizations per patient was 0.39±0.89 pre- and 0.18±0.57 postadoption (P<.001). There were 185 outpatient visits for HF in 96 (24%) patients before adoption and 64 in 48 (12%) patients after adoption (P<.001). The mean number of visits per patient was 0.47±1.11 pre- and 0.16±0.51 postadoption (P<.001). CONCLUSIONS: A standardized follow-up protocol based on remote management of HeartLogic alerts enabled effective remote management of HF patients. After its adoption, we observed a significant reduction in HF hospitalizations and outpatient visits.

2.
J Cardiovasc Med (Hagerstown) ; 25(7): 551-558, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38809231

ABSTRACT

AIMS: In patients undergoing pacemaker implantation with no prior history of heart failure (HF), the presence of left bundle branch block (LBBB) has been identified as an independent predictor of HF-related death or hospitalization, while the prognostic significance of right bundle branch block (RBBB) remains uncertain. We aimed to assess the long-term risk of all-cause mortality in patients with a standard indication for permanent pacing and normal or moderately depressed left ventricular function when RBBB is detected at the time of implantation. METHODS: We retrospectively enrolled 1348 consecutive patients who had undergone single- or dual-chamber pacemaker implantation at the study center, from January 1990 to December 2022. Patients with a left ventricular ejection fraction ≤35% or a prior diagnosis of HF were excluded. RESULTS: The baseline 12-lead electrocardiogram revealed an RBBB in 241 (18%) and an LBBB in 98 (7%) patients. During a median follow-up of 65 [25th-75th percentile: 32-117] months, 704 (52%) patients died. The combined endpoint of cardiovascular death or HF hospitalization was reached by 173 (13%) patients. On multivariate analysis, RBBB was confirmed as an independent predictor of death [hazard ratio, 1.33; 95% confidence interval (CI), 1.09-1.63; P  = 0.005]. However, when considering the combined endpoint of cardiovascular death and HF hospitalization, this endpoint was independently associated with LBBB (hazard ratio, 2.13; 95% CI, 1.38-3.29; P  < 0.001), but not with RBBB. CONCLUSION: In patients with standard pacemaker indications and normal or moderately depressed left ventricular function, the presence of basal RBBB was an independent predictor of mortality. However, it was not associated with the combined endpoint of cardiovascular death and HF hospitalization.


Subject(s)
Bundle-Branch Block , Electrocardiography , Pacemaker, Artificial , Humans , Bundle-Branch Block/therapy , Bundle-Branch Block/physiopathology , Bundle-Branch Block/mortality , Bundle-Branch Block/diagnosis , Male , Female , Aged , Retrospective Studies , Aged, 80 and over , Cardiac Pacing, Artificial/mortality , Risk Factors , Ventricular Function, Left , Heart Failure/mortality , Heart Failure/therapy , Heart Failure/physiopathology , Heart Failure/diagnosis , Time Factors , Hospitalization/statistics & numerical data , Middle Aged , Prognosis , Risk Assessment/methods , Treatment Outcome , Clinical Relevance
4.
Article in English | MEDLINE | ID: mdl-37938506

ABSTRACT

BACKGROUND: The subcutaneous implantable cardioverter defibrillator (S-ICD) and leadless pacemaker (LP) are alternative options for patients at high risk of infection requiring ICD and pacing therapy. In this analysis, we described the simultaneous implantation of S-ICD and LP in patients with high infectious risk. METHODS: The study cohort comprised patients referred to our institution for ICD implantation due to high-risk factors of infection. RESULTS: Between 2018 and 2022, 13 patients were referred, including 11 with infected ICD and 2 for first ICD implantation in the presence of high-risk factors. In cases of infected ICD, successful extraction was performed using a mechanical dilatation technique. Reimplantation was delayed until resolution of infection with antibiotic therapy. The devices were implanted during a single procedure, with S-ICD implantation following LP placement for verification of sensing adequacy through surface ECG screening. Suitable vectors for sensing during inhibited and ventricular pacing were identified in all patients. Defibrillation testing was effective, and no issues with double counting or undersensing were observed. The postoperative period was uneventful, and during a median follow-up of 35 months, no complications or infections were reported. The median ventricular pacing percentage was 5%, and a single inappropriate shock episode due to myopotential interference was reported and resolved by reprogramming the sensing vector. CONCLUSION: Simultaneous implantation of S-ICD and LP is feasible and safe in patients at high risk of infection requiring both ICD and pacing therapy. This combined approach provides an effective solution for these patients.

5.
Europace ; 25(9)2023 08 02.
Article in English | MEDLINE | ID: mdl-37656991

ABSTRACT

AIMS: The HeartLogic Index combines data from multiple implantable cardioverter defibrillators (ICDs) sensors and has been shown to accurately stratify patients at risk of heart failure (HF) events. We evaluated and compared the performance of this algorithm during sinus rhythm and during long-lasting atrial fibrillation (AF). METHODS AND RESULTS: HeartLogic was activated in 568 ICD patients from 26 centres. We found periods of ≥30 consecutive days with an atrial high-rate episode (AHRE) burden <1 h/day and periods with an AHRE burden ≥20 h/day. We then identified patients who met both criteria during the follow-up (AHRE group, n = 53), to allow pairwise comparison of periods. For control purposes, we identified patients with an AHRE burden <1 h throughout their follow-up and implemented 2:1 propensity score matching vs. the AHRE group (matched non-AHRE group, n = 106). In the AHRE group, the rate of alerts was 1.2 [95% confidence interval (CI): 1.0-1.5]/patient-year during periods with an AHRE burden <1 h/day and 2.0 (95% CI: 1.5-2.6)/patient-year during periods with an AHRE-burden ≥20 h/day (P = 0.004). The rate of HF hospitalizations was 0.34 (95% CI: 0.15-0.69)/patient-year during IN-alert periods and 0.06 (95% CI: 0.02-0.14)/patient-year during OUT-of-alert periods (P < 0.001). The IN/OUT-of-alert state incidence rate ratio of HF hospitalizations was 8.59 (95% CI: 1.67-55.31) during periods with an AHRE burden <1 h/day and 2.70 (95% CI: 1.01-28.33) during periods with an AHRE burden ≥20 h/day. In the matched non-AHRE group, the rate of HF hospitalizations was 0.29 (95% CI: 0.12-0.60)/patient-year during IN-alert periods and 0.04 (95% CI: 0.02-0.08)/patient-year during OUT-of-alert periods (P < 0.001). The incidence rate ratio was 7.11 (95% CI: 2.19-22.44). CONCLUSION: Patients received more alerts during periods of AF. The ability of the algorithm to identify increased risk of HF events was confirmed during AF, despite a lower IN/OUT-of-alert incidence rate ratio in comparison with non-AF periods and non-AF patients. CLINICAL TRIAL REGISTRATION: http://clinicaltrials.gov/Identifier: NCT02275637.


Subject(s)
Atrial Fibrillation , Defibrillators, Implantable , Heart Failure , Humans , Algorithms , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/therapy , Heart Atria , Heart Failure/diagnosis , Heart Failure/epidemiology , Heart Failure/therapy
6.
Europace ; 25(9)2023 08 02.
Article in English | MEDLINE | ID: mdl-37536671

ABSTRACT

AIMS: Patients with cardiomyopathies and channelopathies are usually younger and have a predominantly arrhythmia-related prognosis; they have nearly normal life expectancy thanks to the protection against sudden cardiac death provided by the implantable cardioverter defibrillator (ICD). The subcutaneous ICD (S-ICD) is an effective alternative to the transvenous ICD and has evolved over the years. This study aimed to evaluate the rate of inappropriate shocks (IS), appropriate therapies, and device-related complications in patients with cardiomyopathies and channelopathies who underwent modern S-ICD implantation. METHODS AND RESULTS: We enrolled consecutive patients with cardiomyopathies and channelopathies who had undergone implantation of a modern S-ICD from January 2016 to December 2020 and who were followed up until December 2022. A total of 1338 S-ICD implantations were performed within the observation period. Of these patients, 628 had cardiomyopathies or channelopathies. The rate of IS at 12 months was 4.6% [95% confidence interval (CI): 2.8-6.9] in patients with cardiomyopathies and 1.1% (95% CI: 0.1-3.8) in patients with channelopathies (P = 0.032). No significant differences were noted over a median follow-up of 43 months [hazard ratio (HR): 0.76; 95% CI: 0.45-1.31; P = 0.351]. The rate of appropriate shocks at 12 months was 2.3% (95% CI: 1.1-4.1) in patients with cardiomyopathies and 2.1% (95% CI: 0.6-5.3) in patients with channelopathies (P = 1.0). The rate of device-related complications was 0.9% (95% CI: 0.3-2.3) and 3.2% (95% CI: 1.2-6.8), respectively (P = 0.074). No significant differences were noted over the entire follow-up. The need for pacing was low, occurring in 0.8% of patients. CONCLUSION: Modern S-ICDs may be a valuable alternative to transvenous ICDs in patients with cardiomyopathies and channelopathies. Our findings suggest that modern S-ICD therapy carries a low rate of IS. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Subject(s)
Cardiomyopathies , Channelopathies , Defibrillators, Implantable , Humans , Defibrillators, Implantable/adverse effects , Channelopathies/complications , Channelopathies/therapy , Treatment Outcome , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Cardiomyopathies/complications , Cardiomyopathies/therapy , Registries
7.
ESC Heart Fail ; 10(4): 2469-2478, 2023 08.
Article in English | MEDLINE | ID: mdl-37278122

ABSTRACT

AIMS: The HeartLogic algorithm combines multiple implantable defibrillator (ICD) sensor data and has proved to be a sensitive and timely predictor of impending heart failure (HF) decompensation in cardiac resynchronization therapy (CRT-D) patients. We evaluated the performance of this algorithm in non-CRT ICD patients and in the presence of co-morbidities. METHODS AND RESULTS: The HeartLogic feature was activated in 568 ICD patients (410 with CRT-D) from 26 centres. The median follow-up was 26 months [25th-75th percentile: 16-37]. During follow-up, 97 hospitalizations were reported (53 cardiovascular) and 55 patients died. We recorded 1200 HeartLogic alerts in 370 patients. Overall, the time IN the alert state was 13% of the total observation period. The rate of cardiovascular hospitalizations or death was 0.48/patient-year (95% CI: 0.37-0.60) with the HeartLogic IN the alert state and 0.04/patient-year (95% CI: 0.03-0.05) OUT of the alert state, with an incidence rate ratio of 13.35 (95% CI: 8.83-20.51, P < 0.001). Among patient characteristics, atrial fibrillation (AF) on implantation (HR: 1.62, 95% CI: 1.27-2.07, P < 0.001) and chronic kidney disease (CKD) (HR: 1.53, 95% CI: 1.21-1.93, P < 0.001) independently predicted alerts. HeartLogic alerts were not associated with CRT-D versus ICD implantation (HR: 1.03, 95% CI: 0.82-1.30, P = 0.775). Comparisons of the clinical event rates in the IN alert state with those in the OUT of alert state yielded incidence rate ratios ranging from 9.72 to 14.54 (all P < 0.001) in all groups of patients stratified by: CRT-D/ICD, AF/non-AF, and CKD/non-CKD. After multivariate correction, the occurrence of alerts was associated with cardiovascular hospitalization or death (HR: 1.92, 95% CI: 1.05-3.51, P = 0.036). CONCLUSIONS: The burden of HeartLogic alerts was similar between CRT-D and ICD patients, while patients with AF and CKD seemed more exposed to alerts. Nonetheless, the ability of the HeartLogic algorithm to identify periods of significantly increased risk of clinical events was confirmed, regardless of the type of device and the presence of AF or CKD.


Subject(s)
Atrial Fibrillation , Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Humans , Cardiac Resynchronization Therapy/methods , Heart Failure/epidemiology , Heart Failure/therapy , Atrial Fibrillation/etiology , Algorithms , Morbidity
8.
Europace ; 25(6)2023 06 02.
Article in English | MEDLINE | ID: mdl-37350404

ABSTRACT

AIMS: Subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy is expanding rapidly. However, there are few data on the S-ICD extraction procedure and subsequent patient management. The aim of this analysis was to describe the procedure, management, and outcome of S-ICD extractions in clinical practice. METHODS AND RESULTS: We enrolled consecutive patients who required complete S-ICD extraction at 66 Italian centres. From 2013 to 2022, 2718 patients undergoing de novo implantation of an S-ICD were enrolled. Of these, 71 required complete S-ICD system extraction (17 owing to infection). The S-ICD system was successfully extracted in all patients, and no complications were reported; the median procedure duration was 40 (25th-75th percentile: 20-55) min. Simple manual traction was sufficient to remove the lead in 59 (84%) patients, in whom lead-dwelling time was shorter [20 (9-32) months vs. 30 (22-41) months; P = 0.032]. Hospitalization time was short in the case of both non-infectious [2 (1-2) days] and infectious indications [3 (1-6) days]. In the case of infection, no patients required post-extraction intravenous antibiotics, the median duration of any antibiotic therapy was 10 (10-14) days, and the re-implantation was performed during the same procedure in 29% of cases. No complications arose over a median of 21 months. CONCLUSION: The S-ICD extraction was safe and easy to perform, with no complications. Simple traction of the lead was successful in most patients, but specific tools could be needed for systems implanted for a longer time. The peri- and post-procedural management of S-ICD extraction was free from complications and not burdensome for patients and healthcare system. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Subject(s)
Defibrillators, Implantable , Humans , Administration, Intravenous , Anti-Bacterial Agents , Hospitalization , Treatment Outcome
9.
Europace ; 25(4): 1467-1474, 2023 04 15.
Article in English | MEDLINE | ID: mdl-36881780

ABSTRACT

AIMS: Patients with atrial fibrillation frequently experience sleep disorder breathing, and both conditions are highly prevalent in presence of heart failure (HF). We explored the association between the combination of an HF and a sleep apnoea (SA) index and the incidence of atrial high-rate events (AHRE) in patients with implantable defibrillators (ICDs). METHODS AND RESULTS: Data were prospectively collected from 411 consecutive HF patients with ICD. The IN-alert HF state was measured by the multi-sensor HeartLogic Index (>16), and the ICD-measured Respiratory Disturbance Index (RDI) was computed to identify severe SA. The endpoints were as follows: daily AHRE burden of ≥5 min, ≥6 h, and ≥23 h. During a median follow-up of 26 months, the time IN-alert HF state was 13% of the total observation period. The RDI value was ≥30 episodes/h (severe SA) during 58% of the observation period. An AHRE burden of ≥5 min/day was documented in 139 (34%) patients, ≥6 h/day in 89 (22%) patients, and ≥23 h/day in 68 (17%) patients. The IN-alert HF state was independently associated with AHRE regardless of the daily burden threshold: hazard ratios from 2.17 for ≥5 min/day to 3.43 for ≥23 h/day (P < 0.01). An RDI ≥ 30 episodes/h was associated only with AHRE burden ≥5 min/day [hazard ratio 1.55 (95% confidence interval: 1.11-2.16), P = 0.001]. The combination of IN-alert HF state and RDI ≥ 30 episodes/h accounted for only 6% of the follow-up period and was associated with high rates of AHRE occurrence (from 28 events/100 patient-years for AHRE burden ≥5 min/day to 22 events/100 patient-years for AHRE burden ≥23 h/day). CONCLUSIONS: In HF patients, the occurrence of AHRE is independently associated with the ICD-measured IN-alert HF state and RDI ≥ 30 episodes/h. The coexistence of these two conditions occurs rarely but is associated with a very high rate of AHRE occurrence. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Subject(s)
Atrial Fibrillation , Defibrillators, Implantable , Heart Failure , Sleep Apnea Syndromes , Humans , Defibrillators, Implantable/adverse effects , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/therapy , Risk Assessment , Heart Failure/diagnosis , Heart Failure/epidemiology , Heart Failure/therapy
10.
Europace ; 25(5)2023 05 19.
Article in English | MEDLINE | ID: mdl-36932709

ABSTRACT

AIMS: In subcutaneous implantable cardioverter defibrillator (S-ICD) recipients, the UNTOUCHED study demonstrated a very low inappropriate shock rate on programming a conditional zone between 200 and 250 bpm and a shock zone for arrhythmias >250 bpm. The extent to which this programming approach is adopted in clinical practice is still unknown, as is its impact on the rates of inappropriate and appropriate therapies. METHODS AND RESULTS: We assessed ICD programming on implantation and during follow-up in a cohort of 1468 consecutive S-ICD recipients in 56 Italian centres. We also measured the occurrence of inappropriate and appropriate shocks during follow-up. On implantation, the median programmed conditional zone cut-off was set to 200 bpm (IQR: 200-220) and the shock zone cut-off was 230 bpm (IQR: 210-250). During follow-up, the conditional zone cut-off rate was not significantly changed, while the shock zone cut-off was changed in 622 (42%) patients and the median value increased to 250 bpm (IQR: 230-250) (P < 0.001). UNTOUCHED-like programming of detection cut-offs was adopted in 426 (29%) patients immediately after device implantation, and in 714 (49%, P < 0.001) at the last follow-up. UNTOUCHED-like programming was independently associated with fewer inappropriate shocks (hazard ratio 0.50, 95%CI 0.25-0.98, P = 0.044), and had no impact on appropriate and ineffective shocks. CONCLUSIONS: In recent years, S-ICD implanting centres have increasingly programmed high arrhythmia detection cut-off rates, at the time of implantation in the case of new S-ICD recipients, and during follow-up in the case of pre-existing implants. This has contributed significantly to reducing the incidence of inappropriate shocks in clinical practice. Rordorf: Programming of the S-ICD. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Subject(s)
Defibrillators, Implantable , Tachycardia, Ventricular , Humans , Defibrillators, Implantable/adverse effects , Tachycardia, Ventricular/diagnosis , Follow-Up Studies , Prospective Studies , Electric Countershock , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy
11.
J Cardiovasc Electrophysiol ; 34(5): 1257-1267, 2023 05.
Article in English | MEDLINE | ID: mdl-36994907

ABSTRACT

INTRODUCTION: The prediction of ventricular tachyarrhythmias among patients with implantable cardioverter defibrillators is difficult with available clinical tools. We sought to assess whether in patients with heart failure (HF) and reduced ejection fraction with defibrillators, physiological sensor-based HF status, as summarized by the HeartLogic index, could predict appropriate device therapies. METHODS: Five hundred and sixty-eight consecutive HF patients with defibrillators (n = 158, 28%) or cardiac resynchronization therapy-defibrillators (n = 410, 72%) were included in this prospective observational multicenter analysis. The association of both HeartLogic index and its physiological components with defibrillator shocks and overall appropriate therapies was assessed in regression and time-dependent Cox models. RESULTS: Over a follow-up of 25 (15-35) months, 122 (21%) patients received an appropriate device therapy (shock, n = 74, 13%), while the HeartLogic index crossed the threshold value (alert, HeartLogic ≥ 16) 1200 times (0.71 alerts/patient-year) in 370 (65%) subjects. The occurrence of ≥1 HeartLogic alert was significantly associated with both appropriate shocks (Hazard ratios [HR]: 2.44, 95% confidence interval [CI]: 1.49-3.97, p = .003), and any appropriate defibrillator therapies. In multivariable time-dependent Cox models, weekly IN-alert state was the strongest predictor of appropriate defibrillator shocks (HR: 2.94, 95% CI: 1.73-5.01, p < .001) and overall therapies. Compared with stable patients, patients with appropriate shocks had significantly higher values of HeartLogic index, third heart sound amplitude, and resting heart rate 30-60 days before device therapy. CONCLUSION: The HeartLogic index is an independent dynamic predictor of appropriate defibrillator therapies. The combined index and its individual physiological components change before the arrhythmic event occurs.


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Tachycardia, Ventricular , Ventricular Dysfunction, Left , Humans , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/therapy , Tachycardia, Ventricular/complications , Heart Failure/diagnosis , Heart Failure/therapy , Heart Failure/complications , Cardiac Resynchronization Therapy/adverse effects , Ventricular Dysfunction, Left/therapy
12.
Heart Rhythm ; 20(7): 992-997, 2023 Jul.
Article in English | MEDLINE | ID: mdl-36966948

ABSTRACT

BACKGROUND: The HeartLogic algorithm (Boston Scientific) has proved to be a sensitive and timely predictor of impending heart failure (HF) decompensation. OBJECTIVE: The purpose of this study was to determine whether remotely monitored data from this algorithm could be used to identify patients at high risk for mortality. METHODS: The algorithm combines implantable cardioverter-defibrillator (ICD)-measured accelerometer-based heart sounds, intrathoracic impedance, respiration rate, ratio of respiration rate to tidal volume, night heart rate, and patient activity into a single index. An alert is issued when the index crosses a programmable threshold. The feature was activated in 568 ICD patients from 26 centers. RESULTS: During median follow-up of 26 months [25th-75th percentile 16-37], 1200 alerts were recorded in 370 patients (65%). Overall, the time IN-alert state was 13% of the total observation period (151/1159 years) and 20% of the follow-up period of the 370 patients with alerts. During follow-up, 55 patients died (46 in the group with alerts). The rate of death was 0.25 per patient-year (95% confidence interval [CI] 0.17-0.34) IN-alert state and 0.02 per patient-year (95% CI 0.01-0.03) OUT of the alert state, with an incidence rate ratio of 13.72 (95% CI 7.62-25.60; P <.001). After multivariate correction for baseline confounders (age, ischemic cardiomyopathy, kidney disease, atrial fibrillation), the IN-alert state remained significantly associated with the occurrence of death (hazard ratio 9.18; 95% CI 5.27-15.99; P <.001). CONCLUSION: The HeartLogic algorithm provides an index that can be used to identify patients at higher risk for all-cause mortality. The index state identifies periods of significantly increased risk of death.


Subject(s)
Atrial Fibrillation , Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Humans , Cardiac Resynchronization Therapy/adverse effects , Heart Failure/diagnosis , Heart Failure/therapy , Heart Failure/etiology , Atrial Fibrillation/therapy , Algorithms
13.
Europace ; 25(4): 1423-1431, 2023 04 15.
Article in English | MEDLINE | ID: mdl-36794691

ABSTRACT

AIMS: A previous randomized study demonstrated that the subcutaneous implantable cardioverter defibrillator (S-ICD) was noninferior to transvenous ICD with respect to device-related complications and inappropriate shocks. However, that was performed prior to the widespread adoption of pulse generator implantation in the intermuscular (IM) space instead of the traditional subcutaneous (SC) pocket. The aim of this analysis was to compare survival from device-related complications and inappropriate shocks between patients who underwent S-ICD implantation with the generator positioned in an IM position in comparison with an SC pocket. METHODS AND RESULTS: We analysed 1577 consecutive patients who had undergone S-ICD implantation from 2013 to 2021 and were followed up until December 2021. Subcutaneous patients (n = 290) were propensity matched with patients of the IM group (n = 290), and their outcomes were compared. : During a median follow-up of 28 months, device-related complications were reported in 28 (4.8%) patients and inappropriate shocks were reported in 37 (6.4%) patients. The risk of complication was lower in the matched IM group than in the SC group [hazard ratio 0.41, 95% confidence interval (CI) 0.17-0.99, P = 0.041], as well as the composite of complications and inappropriate shocks (hazard ratio 0.50, 95% CI 0.30-0.86, P = 0.013). The risk of appropriate shocks was similar between groups (hazard ratio 0.90, 95% CI 0.50-1.61, P = 0.721). There was no significant interaction between generator positioning and variables such as gender, age, body mass index, and ejection fraction. CONCLUSION: Our data showed the superiority of the IM S-ICD generator positioning in reducing device-related complications and inappropriate shocks. CLINICAL TRIAL REGISTRATION: Clinical Trial Registration: ClinicalTrials.gov; NCT02275637.


Subject(s)
Defibrillators, Implantable , Humans , Defibrillators, Implantable/adverse effects , Case-Control Studies , Death, Sudden, Cardiac/etiology , Retrospective Studies , Treatment Outcome
15.
JACC Clin Electrophysiol ; 8(10): 1249-1256, 2022 10.
Article in English | MEDLINE | ID: mdl-36266001

ABSTRACT

BACKGROUND: Sleep-disordered breathing is highly prevalent in heart failure (HF) and has been suggested as a risk factor for malignant ventricular arrhythmias. The Respiratory Disturbance Index (RDI) computed by an implantable cardioverter-defibrillator (ICD) algorithm accurately identifies severe sleep apnea. OBJECTIVES: In the present analysis, the authors evaluated the association between ICD-detected sleep apnea and the incidence of appropriate ICD therapies in patients with HF. METHODS: We enrolled 411 HF patients who had received an ICD endowed with an algorithm that calculates the RDI each night. In this analysis, the weekly mean RDI value was considered. The endpoint was the first appropriate ICD shock. RESULTS: The median follow-up was 26 months (25th to 75th percentile: 16-35 months). During follow-up, 1 or more ICD shocks were documented in 58 (14%) patients. Patients with shocks were younger (age 66 ± 13 years vs 70 ± 10 years; P = 0.038), and had more frequently undergone implantation for secondary prevention (21% vs 10%; P = 0.026). The maximum RDI value calculated during the entire follow-up period did not differ between patients with and without shocks (55 ± 15 episodes/h vs 54 ± 14 episodes/h; P = 0.539). However, the ICD-detected RDI showed considerable variability during follow-up. The overall median of the weekly RDI was 33 episodes/h (25th to 75th percentile: 24-45 episodes/h). A time-dependent Cox regression model revealed that a continuously measured weekly mean RDI of ≥45 episodes/h was independently associated with shock occurrence (HR: 4.63; 95% CI: 2.54-8.43; P < 0.001), after correction for baseline confounders (age, secondary prevention). CONCLUSIONS: In HF patients, appropriate ICD shocks were more likely to be delivered during periods when patients exhibited more sleep-disordered breathing. (Arrhythmias Detection in a Real World Population [RHYTHM DETECT]; NCT02275637).


Subject(s)
Defibrillators, Implantable , Heart Failure , Sleep Apnea Syndromes , Aged , Humans , Middle Aged , Arrhythmias, Cardiac/epidemiology , Heart Failure/epidemiology , Heart Failure/therapy , Sleep Apnea Syndromes/diagnosis , Sleep Apnea Syndromes/epidemiology
16.
Article in English | MEDLINE | ID: mdl-35927601

ABSTRACT

BACKGROUND: The risk of complications has been shown to be lower with subcutaneous implantable defibrillator (S-ICD) than with conventional ICDs. Given the low frequency of complications, experience of how to manage them is limited. In this paper, we describe generator- and lead-related complications recorded in a series of S-ICD patients, and we propose our conservative approach to managing them. METHODS: The study cohort consisted of S-ICD patients who were referred to our institution owing to generator- or lead-related complications requiring surgical intervention. With our "shift and cover" approach, the system component involved is moved from its original position to an alternative, more protected location. In the case of the generator, this involves moving it to an intermuscular pocket. In the case of infections at the parasternal scar, the electrode sleeve is moved away from its original location, stitched, and then covered with the muscular fascia. RESULTS: Fourteen S-ICD patients were referred to our institution owing to system-related complications. Complications involved the generator in 7 cases (deep pocket infections with erosion, extrusion, or pain), the lead in 5 cases (parasternal infections at the xyphoid incision site), and both the generator and the lead in 2 cases. Complications were managed without completely removing the device and resolved in a single surgical session with no intraoperative complications. During defibrillation testing, the first shock at 65 J was effective in all patients. The shock impedance after revision was significantly lower than that measured during first implantation (59 ± 10 Ohm versus 86 ± 24 Ohm, P = 0.013). In all cases, the cosmetic result was satisfactory. No complications or recurrent infections were reported at the 12-month follow-up visit. CONCLUSIONS: The proposed conservative approach was successful in managing S-ICD complications. The revision procedure allowed to optimize the system configuration in terms of the defibrillation vector, resulting in lower shock impedance values and better device positioning.

18.
Clin Cardiol ; 45(6): 670-678, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35502643

ABSTRACT

AIMS: HeartLogic algorithm combines data from multiple implantable defibrillators (ICD)-based sensors to predict impending heart failure (HF) decompensation. A treatment protocol to manage algorithm alerts is not yet known, although decongestive treatment adjustments are the most frequent alert-triggered actions reported in clinical practice. We describe the implementation of HeartLogic for remote monitoring of HF patients, and we evaluate the approach to diuretic dosing and timing of the intervention in patients with device alerts. METHODS: The algorithm was activated in 229 ICD patients at eight centers. The median follow-up was 17 months (25th-75th percentile: 11-24). Remote data reviews and patient phone contacts were undertaken at the time of HeartLogic alerts, to assess the patient's status and to prevent HF worsening. We analyzed alert-triggered augmented HF treatments, consisting of isolated increases in diuretics dosage. RESULTS: We reported 242 alerts (0.8 alerts/patient-year) in 123 patients, 137 (56%) alerts triggered clinical actions to treat HF. The HeartLogic index decreased after the 56 actions consisting of diuretics increase. Specifically, alerts resolved more quickly when the increases in dosing of diuretics were early rather than late: 28 days versus 62 days, p < .001. The need of hospitalization for further treatments to resolve the alert condition was associated with higher HeartLogic index values on the day of the diuretics increase (odds ratio: 1.11, 95% CI: 1.02-1.20, p = .013) and with late interventions (odds ratio: 5.11, 95% CI: 1.09-24.48, p = .041). No complications were reported after drug adjustments. CONCLUSIONS: Decongestive treatment adjustments triggered by alerts seem safe and effective. The early use of decongestive treatment and the use of high doses of diuretics seem to be associated with more favorable outcomes.


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Algorithms , Cardiac Resynchronization Therapy/methods , Diuretics/therapeutic use , Heart Failure/diagnosis , Heart Failure/therapy , Humans
19.
J Interv Card Electrophysiol ; 64(1): 257-264, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35412167

ABSTRACT

BACKGROUND: The remote device management (RM) is recommended for patients with cardiac implantable electronic devices (CIEDs). RM underutilization is frequently driven by the lack of correct system activation. The MyLATITUDE Patient App (Boston Scientific) has been developed to encourage patient compliance with RM by providing information on communicator setup, troubleshooting, and connection status of the communicator. METHODS: At 14 centers, patients with CIEDs were invited to download and install the App on a mobile device. After 3 months, patients were asked to complete an ad hoc questionnaire to evaluate their experience. RESULTS: The App was proposed to 242 consecutive patients: 81 before RM activation, and 161 during follow-up. The App was successfully installed by 177 (73%) patients. The time required for activation of the communicator and the need for additional support were similar between patients who followed the indications provided by the App and those who underwent standard in-clinic training. During follow-up, notifications of lack of connection were received by 20 (11%) patients and missed transmission by 22 (12%). The median time from notification to resolution was 2 days. After 3 months, 175 (99%) communicators of the 177 patients who installed the App were in "Monitored" status versus 113 (94%) of 120 patients without the App installed (p=0.033). The use of the app made 84% of patients feel reassured. CONCLUSIONS: The App was well accepted by CIED patients and offered support for communicator management and installation. Its use enabled patients to remain connected with greater continuity during follow-up.


Subject(s)
Defibrillators, Implantable , Mobile Applications , Pacemaker, Artificial , Humans , Monitoring, Physiologic , Multicenter Studies as Topic , Patient Compliance
20.
Biology (Basel) ; 11(1)2022 Jan 12.
Article in English | MEDLINE | ID: mdl-35053117

ABSTRACT

AIMS: The utilization of remote monitoring platforms was recommended amidst the COVID-19 pandemic. The HeartLogic index combines multiple implantable cardioverter defibrillator (ICD) sensors and has proved to be a predictor of impending heart failure (HF) decompensation. We examined how multiple ICD sensors behave in the periods of anticipated restrictions pertaining to physical activity. METHODS: The HeartLogic feature was active in 349 ICD and cardiac resynchronization therapy ICD patients at 20 Italian centers. The period from 1 January to 19 July 2020, was divided into three phases: pre-lockdown (weeks 1-11), lockdown (weeks 12-20), post-lockdown (weeks 21-29). RESULTS: Immediately after the implementation of stay-at-home orders (week 12), we observed a significant drop in median activity level whereas there was no difference in the other contributing parameters. The median composite HeartLogic index increased at the end of the Lockdown. The weekly rate of alerts was significantly higher during the lockdown (1.56 alerts/week/100 pts, 95%CI: 1.15-2.06; IRR = 1.71, p = 0.014) and post-lockdown (1.37 alerts/week/100 pts, 95%CI: 0.99-1.84; IRR = 1.50, p = 0.072) than that reported in pre-lockdown (0.91 alerts/week/100 pts, 95%CI: 0.64-1.27). However, the median duration of alert state and the maximum index value did not change among phases, as well as the proportion of alerts followed by clinical actions at the centers and the proportion of alerts fully managed remotely. CONCLUSIONS: During the lockdown, the system detected a significant drop in the median activity level and generated a higher rate of alerts suggestive of worsening of the HF status.

SELECTION OF CITATIONS
SEARCH DETAIL
...