Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 38
Filter
1.
J Cardiovasc Electrophysiol ; 35(2): 258-266, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38065834

ABSTRACT

BACKGROUND: Incomplete atrial lesions resulting in pulmonary vein-left atrium reconnection after pulmonary vein antrum isolation (PVAI), are related to atrial fibrillation (AF) recurrence. Unfortunately, during the PVAI procedure, fluoroscopy and electroanatomic mapping cannot accurately determine the location and size of the ablation lesions in the atrial wall and this can result in incomplete PVAI lesions (PVAI-L) after radiofrequency catheter ablation (RFCA). AIM: We seek to evaluate whether cardiac magnetic resonance (CMR), immediately after RFCA of AF, can identify PVAI-L by characterizing the left atrial tissue. METHODS: Ten patients (63.1 ± 5.7 years old, 80% male) receiving a RFCA for paroxysmal AF underwent a CMR before (<1 week) and after (<1 h) the PVAI. Two-dimensional dark-blood T2-weighted short tau inversion recovery (DB-STIR), Three-dimensional inversion-recovery prepared long inversion time (3D-TWILITE) and three-dimensional late gadolinium enhancement (3D-LGE) images were performed to visualize PVAI-L. RESULTS: The PVAI-L was visible in 10 patients (100%) using 3D-TWILITE and 3D-LGE. Conversely, On DB-STIR, the ablation core of the PAVI-L could not be identified because of a diffuse high signal of the atrial wall post-PVAI. Microvascular obstruction was identified in 7 (70%) patients using 3D-LGE. CONCLUSION: CMR can visualize PVAI-L immediately after the RFCA of AF even without the use of contrast agents. Future studies are needed to understand if the use of CMR for PVAI-L detection after RFCA can improve the results of ablation procedures.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Male , Middle Aged , Aged , Female , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Contrast Media , Treatment Outcome , Gadolinium , Magnetic Resonance Spectroscopy , Catheter Ablation/adverse effects , Catheter Ablation/methods , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery
2.
Eur Heart J Suppl ; 25(Suppl C): C265-C270, 2023 May.
Article in English | MEDLINE | ID: mdl-37125279

ABSTRACT

Radiofrequency (RF) catheter ablation has become a widely used therapeutic approach. However, long-term results in terms of arrhythmia recurrence are still suboptimal. Cardiac magnetic resonance (CMR) could offer a valuable tool to overcome this limitation, with the possibility of targeting the arrhythmic substrate and evaluating the location, depth, and possible gaps of RF lesions. Moreover, real-time CMR-guided procedures offer a radiation-free approach with an evaluation of anatomical structures, substrates, RF lesions, and possible complications during a single procedure. The first steps in the field have been made with cavotricuspid isthmus ablation, showing similar procedural duration and success rate to standard fluoroscopy-guided procedures, while allowing visualization of anatomic structures and RF lesions. These promising results open the path for further studies in the context of more complex arrhythmias, like atrial fibrillation and ventricular tachycardias. Of note, setting up an interventional CMR (iCMR) centre requires safety and technical standards, mostly related to the need for CMR-compatible equipment and medical staff's educational training. For the cardiac imagers, it is fundamental to provide correct CMR sequences for catheter tracking and guide RF delivery. At the same time, the electrophysiologist needs a rapid interpretation of CMR images during the procedures. The aim of this paper is first to review the logistic and technical aspects of setting up an iCMR suite. Then, we will describe the experience in iCMR-guided flutter ablations of two European centres, Policlinico Casilino in Rome, Italy, and Haga Teaching Hospital in The Hague, the Netherlands.

3.
Pacing Clin Electrophysiol ; 45(10): 1248-1254, 2022 10.
Article in English | MEDLINE | ID: mdl-36031774

ABSTRACT

AIMS: To evaluate safety of leadless pacemaker implantation through the internal jugular vein in a larger cohort with longer follow-up. Moreover, feasibility of non-apical pacing as well as relation between pacing site and QRS duration were assessed. METHODS: Eighty Two consecutive patients, who received a leadless pacemaker though the internal jugular vein, were included. Electrical parameters were measured at regular follow-up and any complications were registered. Paced QRS interval was compared for three pacing sites, RVOT, RV mid septum, and RV apical septum. RESULTS: In all patients, the leadless pacemaker was implanted successfully. In 69 patients, the device was implanted in a non-apical position. In 71% of cases, the device could be deployed at first attempt. The median fluoroscopy time was 4.4 min (range 0.9-51) The paced QRS interval was significantly narrower for non-apical pacing sites compared to apical pacing si 156  vs. 179 ms. p = .04, respectively. During mean follow-up of 16 months (range 0-43 months), electrical parameters remained stable. Two complications occurred, which could be resolved during the implant procedure. There were no access site related complications. CONCLUSION: The jugular approach for leadless pacemaker implantation is feasible and may avoid vascular complications. It facilitates non-apical positioning of leadless pacemakers leading to a narrower paced QRS interval. The jugular approach allows for immediate post procedural ambulation.


Subject(s)
Pacemaker, Artificial , Humans , Equipment Design , Jugular Veins , Cardiac Pacing, Artificial , Treatment Outcome
4.
Ther Adv Cardiovasc Dis ; 16: 17539447221119624, 2022.
Article in English | MEDLINE | ID: mdl-36039865

ABSTRACT

BACKGROUND: Cardiac magnetic resonance (CMR) provides excellent temporal and spatial resolution, tissue characterization, and flow measurements. This enables major advantages when guiding cardiac invasive procedures compared with X-ray fluoroscopy or ultrasound guidance. However, clinical implementation is limited due to limited availability of technological advancements in magnetic resonance imaging (MRI) compatible equipment. A systematic review of the available literature on past and present applications of interventional MR and its technology readiness level (TRL) was performed, also suggesting future applications. METHODS: A structured literature search was performed using PubMed. Search terms were focused on interventional CMR, cardiac catheterization, and other cardiac invasive procedures. All search results were screened for relevance by language, title, and abstract. TRL was adjusted for use in this article, level 1 being in a hypothetical stage and level 9 being widespread clinical translation. The papers were categorized by the type of procedure and the TRL was estimated. RESULTS: Of 466 papers, 117 papers met the inclusion criteria. TRL was most frequently estimated at level 5 meaning only applicable to in vivo animal studies. Diagnostic right heart catheterization and cavotricuspid isthmus ablation had the highest TRL of 8, meaning proven feasibility and efficacy in a series of humans. CONCLUSION: This article shows that interventional CMR has a potential widespread application although clinical translation is at a modest level with TRL usually at 5. Future development should be directed toward availability of MR-compatible equipment and further improvement of the CMR techniques. This could lead to increased TRL of interventional CMR providing better treatment.


Subject(s)
Magnetic Resonance Imaging, Interventional , Animals , Humans , Magnetic Resonance Imaging , Magnetic Resonance Imaging, Interventional/methods , Magnetic Resonance Spectroscopy , Predictive Value of Tests , Technology
5.
Circ Arrhythm Electrophysiol ; 15(8): e010835, 2022 08.
Article in English | MEDLINE | ID: mdl-35917465

ABSTRACT

BACKGROUND: Irreversible electroporation (IRE) ablation is generally performed with multielectrode catheters. Electrode-tissue contact is an important predictor for the success of pulmonary vein (PV) isolation; however, contact force is difficult to measure with multielectrode ablation catheters. In a preclinical study, we assessed the feasibility of a multielectrode impedance system (MEIS) as a predictor of long-term success of PV isolation. In addition, we present the first-in-human clinical experience with MEIS. METHODS: In 10 pigs, one PV was ablated based on impedance (MEIS group), and the other PV was solely based on local electrogram information (EP group). IRE ablations were performed at 200 J. After 3 months, recurrence of conduction was assessed. Subsequently, in 30 patients undergoing PV isolation with IRE, MEIS was evaluated and MEIS contact values were compared to local electrograms. RESULTS: In the porcine study, 43 IRE applications were delivered in 19 PVs. Acutely, no reconnections were observed in either group. After 3 months, 0 versus 3 (P=0.21) PVs showed conduction recurrence in the MEIS and EP groups, respectively. Results from the clinical study showed a significant linear relation was found between mean MEIS value and bipolar dV/dt (r2=0.49, P<0.001), with a slope of 20.6 mV/s per Ohm. CONCLUSIONS: Data from the animal study suggest that MEIS values predict effective IRE applications. For the long-term success of electrical PV isolation with circular IRE applications, no significant difference in efficacy was found between ablation based on the measurement of electrode interface impedance and ablation using the classical EP approach for determining electrode-tissue contact. Experiences of the first clinical use of MEIS were promising and serve as an important basis for future research.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Animals , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Electroporation , Heart Rate , Humans , Pulmonary Veins/surgery , Swine , Treatment Outcome
7.
J Cardiovasc Electrophysiol ; 33(3): 360-367, 2022 03.
Article in English | MEDLINE | ID: mdl-35018697

ABSTRACT

INTRODUCTION: Electroporation ablation creates deep and wide myocardial lesions. No data are available on time course and characteristics of acute lesion formation. METHODS: For the acute phase of myocardial lesion development, seven pigs were investigated. Single 200 J applications were delivered at four different epicardial right ventricular sites using a linear suction device, yielding a total of 28 lesions. Timing of applications was designed to yield lesions at seven time points: 0, 10, 20, 30, 40, 50, and 60 min, with four lesions per time point. After killing, lesion characteristics were histologically investigated. For the chronic phase of myocardial lesion development, tissue samples were used from previously conducted studies where tissue was obtained at 3 weeks and 3 months after electroporation ablation. RESULTS: Acute myocardial lesions induce a necrosis pattern with contraction band necrosis and interstitial edema, immediately present after electroporation ablation. No further histological changes such as hemorrhage or influx of inflammatory cells occurred in the first hour. After 3 weeks, the lesions consisted of sharply demarcated loose connective tissue that further developed to more fibrotic scar tissue after 3 months without additional changes. Within the scar tissue, arteries and nerves were unaffected. CONCLUSION: Electroporation ablation immediately induces contraction band necrosis and edema without additional tissue changes in the first hour. After 3 weeks, a sharply demarked scar has been developed that remains stable during follow-up of 3 months. This is highly relevant for clinical application of electroporation ablation in terms of the electrophysiological endpoint and waiting period after ablation.


Subject(s)
Catheter Ablation , Animals , Catheter Ablation/adverse effects , Electroporation , Heart Ventricles , Swine
8.
J Cardiovasc Electrophysiol ; 33(3): 559-564, 2022 03.
Article in English | MEDLINE | ID: mdl-35040534

ABSTRACT

BACKGROUND: Persistent phrenic nerve palsy (PNP) is an established complication of atrial fibrillation (AF) ablation, especially during cryoballoon and thoracoscopic ablation. Data on persistent PNP reversibility is limited because most patients recover <24 h. This study aims to investigate persistent PNP recovery, freedom of PNP-related symptoms after AF ablation and identify baseline variables associated with the occurrence and early PNP recovery in a large nationwide registry study. METHODS: In this study, we used data from the Netherlands Heart Registration, comprising data from 9549 catheter and thoracoscopic AF ablations performed in 2016 and 2017. PNP data was available of 7433 procedures, and additional follow-up data were collected for patients who developed persistent PNP. RESULTS: Overall, the mean age was 62 ± 10 years, and 67.7% were male. Fifty-four (0.7%) patients developed persistent PNP and follow-up was available in 44 (81.5%) patients. PNP incidence was 0.07%, 0.29%, 1.41%, and 1.25%, respectively for patients treated with conventional-RF, phased-RF, cryoballoon, and thoracoscopic ablation respectively. Seventy-one percent of the patients fully recovered, and 86% were free of PNP-related symptoms after a median follow-up of 203 (113-351) and 184 (82-359) days, respectively. Female sex, cryoballoon, and thoracoscopic ablation were associated with a higher risk to develop PNP. Patients with PNP recovering ≤180 days had a larger left atrium volume index than those with late or no recovery. CONCLUSION: After AF ablation, persistent PNP recovers in the majority of patients, and most are free of symptoms. Female patients and patients treated with cryoballoon or thoracoscopic ablation are more prone to develop PNP.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Cryosurgery/adverse effects , Cryosurgery/methods , Female , Follow-Up Studies , Humans , Male , Middle Aged , Netherlands/epidemiology , Paralysis/etiology , Phrenic Nerve , Pulmonary Veins/surgery , Treatment Outcome
9.
J Hypertens ; 40(3): 606-614, 2022 03 01.
Article in English | MEDLINE | ID: mdl-34862332

ABSTRACT

BACKGROUND: The severity of COVID-19 after SARS-CoV-2 infection is unpredictable. Angiotensin-converting enzyme-2 (ACE2) is the receptor responsible for coronavirus binding, while subsequent cell entry relies on priming by the serine protease TMPRSS2 (transmembrane protease, serine 2). Although renin-angiotensin-aldosterone-system (RAAS) blockers have been suggested to upregulate ACE2, their use in COVID-19 patients is now considered well tolerated. The aim of our study was to investigate parameters that determine COVID-19 severity, focusing on RAAS-components and variation in the genes encoding for ACE2 and TMPRSS2. METHODS: Adult patients hospitalized due to SARS-CoV-2 infection between May 2020 and October 2020 in the Haga Teaching Hospital were included, and soluble ACE2 (sACE2), renin, aldosterone (in heparin plasma) and polymorphisms in the ACE2 and TMPRSS2 genes (in DNA obtained from EDTA blood) were determined. MEASUREMENTS AND MAIN RESULTS: Out of the 188 patients who were included, 60 were defined as severe COVID-19 (ICU and/or death). These patients more often used antidiabetic drugs, were older, had higher renin and sACE2 levels, lower aldosterone levels and a lower aldosterone/renin ratio. In addition, they displayed the TMPRSS2-rs2070788 AA genotype less frequently. No ACE2 polymorphism-related differences were observed. Multivariate regression analysis revealed independent significance for age, sACE2, the aldosterone/renin ratio, and the TMPRSS2 rs2070788 non-AA genotype as predictors of COVID-19 severity, together yielding a C-index of 0.79. Findings were independent of the use of RAAS blockers. CONCLUSION: High sACE2, a low aldosterone/renin ratio and having the TMPRSS2 rs2070788 non-AA genotype are novel independent determinants that may help to predict COVID-19 disease severity. TRIAL REGISTRATION: retrospectively registered.


Subject(s)
Aldosterone/blood , Angiotensin-Converting Enzyme 2/blood , COVID-19 , Renin/blood , Angiotensin-Converting Enzyme 2/genetics , COVID-19/diagnosis , Humans , Renin-Angiotensin System , SARS-CoV-2 , Serine Endopeptidases/genetics
10.
Europace ; 23(2): 216-225, 2021 02 05.
Article in English | MEDLINE | ID: mdl-33141152

ABSTRACT

AIMS: Pulmonary vein isolation (PVI) has become a cornerstone of the invasive treatment of atrial fibrillation. Severe complications are reported in 1-3% of patients. This study aims to compare complications and follow-up outcome of PVI in patients with atrial fibrillation. METHODS AND RESULTS: The data were extracted from the Netherlands Heart Registration. Procedural and follow-up outcomes in patients treated with conventional radiofrequency (C-RF), multielectrode phased RF (Ph-RF), or cryoballoon (CB) ablation from 2012 to 2017 were compared. Subgroup analysis was performed to identify variables associated with complications and repeat ablations. In total, 13 823 patients (69% male) were included. The reported complication incidence was 3.6%. Patients treated with C-RF developed more cardiac tamponades (C-RF 0.8% vs. Ph-RF 0.3% vs. CB 0.3%, P ≤ 0.001) and vascular complications (C-RF 1.7% vs. Ph-RF 1.2% vs. CB 1.3%, P ≤ 0.001). Ph-RF was associated with fewer bleeding complications (C-RF: 1.0% vs. Ph-RF: 0.4% vs. CB: 0.7%, P = 0.020). Phrenic nerve palsy mainly occurred in patients treated with CB (C-RF: 0.1% vs. Ph-RF: 0.2% vs. CB: 1.5%, P ≤ 0.001). In total, 18.4% of patients were referred for repeat ablation within 1 year. Female sex, age, and CHA2DS2-VASc were independent risk factors for cardiac tamponade and bleeding complications, with an adjusted OR for female patients of 2.97 (95% CI 1.98-4.45) and 2.02 (95% CI 1.03-4.00) respectively. CONCLUSION: The reported complication rate during PVI was low. Patients treated with C-RF ablation were more likely to develop cardiac tamponades and vascular complications. Female sex was associated with more cardiac tamponade and bleeding complications.


Subject(s)
Ablation Techniques , Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Cryosurgery/adverse effects , Female , Humans , Male , Netherlands/epidemiology , Pulmonary Veins/surgery , Recurrence , Treatment Outcome
11.
Biomed Eng Online ; 18(1): 75, 2019 Jun 20.
Article in English | MEDLINE | ID: mdl-31221146

ABSTRACT

BACKGROUND: Irreversible electroporation (IRE) using direct current (DC) is an effective method for the ablation of cardiac tissue. A major drawback of the use of DC-IRE, however, are two problems: requirement of general anesthesia due to severe muscle contractions and the formation of bubbles containing gaseous products from electrolysis. The use of high-frequency alternating current (HF-IRE) is expected to solve both problems, because HF-IRE produces little to no muscle spasms and does not cause electrolysis. METHODS: In the present study, we introduce a novel asymmetric, high-frequency (aHF) waveform for HF-IRE and present the results of a first, small, animal study to test its efficacy. RESULTS: The data of the experiments suggest that the aHF waveform creates significantly deeper lesions than a symmetric HF waveform of the same energy and frequency (p = 0.003). CONCLUSION: We therefore conclude that the use of the aHF enhances the feasibility of the HF-IRE method.


Subject(s)
Ablation Techniques/methods , Arrhythmias, Cardiac/therapy , Electroporation/methods , Animals , Arrhythmias, Cardiac/physiopathology , Electric Conductivity , Myocardial Contraction , Swine
12.
J Cardiovasc Electrophysiol ; 30(6): 877-885, 2019 06.
Article in English | MEDLINE | ID: mdl-30848001

ABSTRACT

INTRODUCTION: Stroke is one of the most feared complications during catheter ablation of atrial fibrillation (AF). While symptomatic thromboembolic events are rare, magnetic resonance imaging (MRI) may identify asymptomatic (ie, silent) cerebral lesions (SCLs) following pulmonary vein isolation (PVI) procedures. METHODS AND RESULTS: The REDUCE-TE Pilot was a prospective multicenter, single-arm observational study investigating the incidence of SCL in patients with symptomatic paroxysmal AF undergoing PVI with a novel gold-tip, externally irrigated ablation catheter. After ablation, cerebral diffusion-weighted MRI and a postablation follow-up were performed at 1 to 3 days after the ablation procedure. A neurocognitive test was done before and after ablation. The primary study endpoint was the occurrence of one or more new SCLs. Secondary study endpoints included neurocognitive status, procedural success rate, and periprocedural complications including symptomatic thromboembolic events. A total of 104 patients were enrolled (69% male, mean age: 61.5 ± 9.7 years, mean CHA2 DS 2 -VASc score: 1.7 ± 1.2). Postprocedural MRI examination was performed in 97 patients, and in nine of them (9.3%; 95% CI: 4.3-16.9%) a total of 11 SCLs were detected. Univariate analyses did not reveal any significant predictor for new SCLs. Nonsignificant trends were observed for low activated clotting time during ablation and for international normalized ratio value outside the range of 2 to 3 at ablation. There was no evidence of significant deterioration of neurocognitive function after PVI. In four patients, a pericardial tamponade was noted but all patients fully recovered during follow-up. CONCLUSIONS: Ablation of AF using a novel gold-tip, externally irrigated ablation catheter, resulted in SCLs in approximately one out of 10 patients without a measurable effect on neurocognitive function.


Subject(s)
Atrial Fibrillation/surgery , Cardiac Catheters , Catheter Ablation/adverse effects , Catheter Ablation/instrumentation , Cognition , Gold , Intracranial Embolism/epidemiology , Postoperative Cognitive Complications/epidemiology , Pulmonary Veins/surgery , Therapeutic Irrigation/adverse effects , Therapeutic Irrigation/instrumentation , Action Potentials , Aged , Asymptomatic Diseases , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Diffusion Magnetic Resonance Imaging , Equipment Design , Female , Germany/epidemiology , Heart Rate , Humans , Incidence , Intracranial Embolism/diagnostic imaging , Male , Mental Status and Dementia Tests , Middle Aged , Pilot Projects , Postoperative Cognitive Complications/diagnosis , Postoperative Cognitive Complications/psychology , Pulmonary Veins/physiopathology , Time Factors , Treatment Outcome
13.
Pacing Clin Electrophysiol ; 42(4): 395-399, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30653690

ABSTRACT

BACKGROUND: Leadless pacing is generally performed from a femoral approach. However, the femoral route is not always available. Until now, data regarding implantation using a jugular approach other than a single-case report were lacking. METHODS: The case records of all patients who underwent internal jugular venous (IJV) leadless pacemaker implantation (Micra, Medtronic, Dublin, Ireland) at our center were analyzed retrospectively. RESULTS: Nineteen patients underwent IJV leadless pacemaker implantation, nine females, mean age of 77.5 ±9.6  years; permanent atrial fibrillation in all patients with normal left ventricular ejection fraction. Implant indication was atrioventricular conduction disturbance in 10, pre-AV node ablation in seven, and replacement of a conventional VVI pacemaker in two (infection in one and lead malfunction in the other). The device was positioned at the superior septum in seven patients, apicoseptal in seven patients, and midseptal in five patients. In 12 patients, a sufficient device position was obtained at the first attempt, in three at the second, in one at the third, in one at the fourth, and in two at the sixth attempt. The mean pacing threshold was 0.56 ± 0.39V at 0.24-ms pulse width, sensed amplitude was 9.1 ± 3.2 mV, mean fluoroscopy duration was 3.1 ± 1.6 min. There were no vascular or other complications. At follow-up, electrical parameters remained stable in 18 of 19 patients. CONCLUSION: Although experience is minimal, we suggest that the IJV approach is safe and may be considered in patients where the femoral approach is contraindicated.


Subject(s)
Atrial Fibrillation/surgery , Atrioventricular Block/therapy , Catheter Ablation/methods , Jugular Veins , Pacemaker, Artificial , Aged , Atrial Fibrillation/physiopathology , Atrioventricular Block/physiopathology , Equipment Design , Female , Humans , Male , Reoperation , Retrospective Studies
15.
J Cardiovasc Electrophysiol ; 29(9): 1210-1220, 2018 09.
Article in English | MEDLINE | ID: mdl-29846989

ABSTRACT

BACKGROUND: Advancements in electrophysiology 3-D mapping systems facilitate the broadening scope of electrophysiology study and catheter ablation to treat complex arrhythmias. While electroanatomical mapping systems have default settings available for a variety of mapping parameters, significant operator customization driven by arrhythmia type and experience can occur. However, multicenter comprehensive reporting of customized mapping settings is lacking. METHODS: In this prospective, multicenter observational registry, subjects with cardiac arrhythmias underwent electrophysiology study and ablation procedure using the EnSite Precision™ electroanatomical mapping system per standard of care, and associated automated mapping thresholds and procedural characteristics were observed. RESULTS: Cardiac mapping and ablation was performed in 503 patients (64.4% male, 59.6 ± 13.2 years) for a variety of indications including atrial fibrillation (N = 277), atrial flutter (N = 67), other supraventricular tachycardias (N = 96), and ventricular tachycardia (N = 56). Automated electroanatomical mapping was used to generate 88.2% of all maps, and arrhythmia-specific adjustments of mapping thresholds were utilized to collect electrophysiologically relevant data. The most commonly used thresholds for mapping in AF were Distance (average 2.7 ± 3.5 mm) and Signal-to-Noise Ratio (5.2 ± 1.1), while mapping in VT commonly used Score (88.5 ± 6.5%) and Distance (0.6 ± 0.5 mm). Automated mapping collected and utilized 8.8 times more data than manual mapping without increasing mapping time. CONCLUSIONS: This registry revealed arrhythmia-specific automated mapping settings used to generate electroanatomical maps of multiple cardiac rhythms with higher point density than manual mapping without increasing mapping time. Commonly used mapping threshold settings could serve as an important reference for new automated electroanatomical mapping users or those expanding their usage to new indications and arrhythmias.


Subject(s)
Atrial Fibrillation/diagnostic imaging , Atrial Flutter/diagnostic imaging , Electrophysiologic Techniques, Cardiac/methods , Imaging, Three-Dimensional/methods , Tachycardia, Supraventricular/diagnostic imaging , Adult , Aged , Atrial Fibrillation/physiopathology , Atrial Fibrillation/surgery , Atrial Flutter/physiopathology , Atrial Flutter/surgery , Catheter Ablation , Female , Humans , Male , Middle Aged , Prospective Studies , Registries , Tachycardia, Supraventricular/physiopathology , Tachycardia, Supraventricular/surgery
16.
Europace ; 20(1): 149-156, 2018 01 01.
Article in English | MEDLINE | ID: mdl-28064250

ABSTRACT

Aims: With multi-electrode catheters, measuring contact force (CF) on each electrode is technically challenging. Present electrical methods, like the electrical coupling index (ECI) may yield false positive values in pulmonary veins. We developed a novel method that measures electrode-interface resistance (IR) by applying a very local electrical field between neighbouring catheter electrodes while measuring voltage between each catheter electrode and a skin patch. The aim of this study was to evaluate the new IR method to measure electrode-tissue contact. Methods and results: In vitro, effects of remote high-impedance structures were studied. In addition, both ECI and IR were directly compared with true electrode-tissue CF. In five pigs, the influence of high-impedance pulmonary tissue on ECI and IR was investigated while navigating the free floating catheter into the caval veins. Inside the left atrium (LA), IR was directly compared with CF. Finally, multi-electrode IR measurements in the LA and inferior pulmonary vein (IPV) were compared. In vitro, IR is much less affected by remote high-impedance structures than ECI (3% vs. 32%). Both IR and ECI strongly relate to electrode-tissue CF (r2 = 0.84). In vivo, and in contrast to ECI, IR was not affected by nearby pulmonary tissue. Inside the LA, a strong relation between IR and CF was found. This finding was confirmed by simultaneous multi-electrode measurements in LA and IPV. Conclusion: Data of the present study suggest that electrode-tissue contact affects the IR while being highly insensitive to remote structures. This method facilitates electrode-tissue contact measurements with circular multi-electrode ablation catheters.


Subject(s)
Cardiac Catheterization/instrumentation , Cardiac Catheters , Catheter Ablation/instrumentation , Heart Atria/surgery , Pulmonary Veins/surgery , Animals , Electric Impedance , Equipment Design , Materials Testing , Models, Animal , Sus scrofa
17.
Article in English | MEDLINE | ID: mdl-28487347

ABSTRACT

BACKGROUND: Esophageal ulceration and fistula are complications of pulmonary vein isolation using thermal energy sources. Irreversible electroporation is a novel, nonthermal ablation modality for pulmonary vein isolation. A single 200 J application can create deep myocardial lesions. Acute and chronic effects of this new energy source on the esophagus are unknown. METHODS AND RESULTS: In 8 pigs (±70 kg), the suprasternal esophagus was surgically exposed. A linear suction device with a single 35-mm long and 6-mm wide protruding linear electrode inside a plastic suction cup was used for ablation. Single, nonarcing, nonbarotraumatic, cathodal 100 and 200 J applications were delivered at 2 different sites on the anterior esophageal adventitia. No proton-pump inhibitors were administered during follow-up. Esophagoscopy was performed at days 2 and 7. After euthanasia at day 60, the esophagus was evaluated visually and histologically. All ablations were uneventful. Esophagoscopy at day 2 showed small white densities in the ablated areas, which appeared to be small intraepithelial vesicles. No epithelial erythema, erosions, or ulcerations were seen. At day 7, all densities had disappeared, and all esophaguses appeared completely normalized. After euthanasia, there were no macroscopically visible lesions on the adventitia or epithelium. Histologically, a small scar was observed at the outer part of the muscular layer, whereas the mucosa and submucosa were normal. CONCLUSIONS: Esophageal architecture remains unaffected 2 months after irreversible electroporation, purposely targeting the adventitia. Irreversible electroporation seems to be a safe modality for catheter ablation near the esophagus.


Subject(s)
Adventitia/surgery , Catheter Ablation/methods , Electroporation , Esophagus/surgery , Adventitia/pathology , Animals , Biopsy , Catheter Ablation/adverse effects , Esophagoscopy , Esophagus/pathology , Models, Animal , Risk Assessment , Sus scrofa , Time Factors
18.
J Cardiovasc Electrophysiol ; 27(12): 1403-1410, 2016 12.
Article in English | MEDLINE | ID: mdl-27565119

ABSTRACT

INTRODUCTION: Reliable detection and monitoring of atrial fibrillation (AF) is essential for accurate clinical decision making, which can now be done continuously with the introduction of implantable cardiac monitors (ICM) The DETECT AF study evaluated the performance of the Confirm DM2102 ICM (St. Jude Medical, St. Paul, MN, USA) to accurately detect and monitor AF. METHODS: Ninety patients previously implanted with the ICM and with either suspected or known paroxysmal AF were enrolled at 12 centers in Germany and The Netherlands. At least 2 weeks after ICM implant, patients wore a Holter monitor for 4 days, while the ICM monitored for AF episodes lasting at least 2 minutes. Holter monitor data was analyzed by a blinded, independent core laboratory and compared to the ICM AF detections. Patient and episode sensitivity (SE), specificity (SP), positive predictive value (PPV), and negative predictive (NPV) were calculated using standard analysis and a generalized estimation equation method where appropriate. RESULTS: A total of 79/90 subjects (61% male, 65.7 ± 9.6 years old) were included in the analysis, totaling 6,894 hours of Holter monitoring. Using a per patient analysis SE was 100%, PPV was 64.0%, SP was 85.7%, and NPV was 100%. Using a per episode analysis, SE was 94.0% and PPV was 64.0%. With an AF duration analysis, the SE was 83.9%, PPV was 97.3%, SP was 99.4% with an NPV of 98.5%. CONCLUSION: The SJM Confirm DM2102 can accurately and repeatedly detect paroxysmal AF episodes of at least 2 minutes in length.


Subject(s)
Atrial Fibrillation/diagnosis , Electrocardiography, Ambulatory/instrumentation , Heart Conduction System/physiopathology , Transducers , Action Potentials , Aged , Atrial Fibrillation/physiopathology , Equipment Design , Female , Germany , Heart Rate , Humans , Male , Materials Testing , Middle Aged , Netherlands , Predictive Value of Tests , Prospective Studies , Reproducibility of Results , Signal Processing, Computer-Assisted
19.
Europace ; 18(9): 1335-42, 2016 Sep.
Article in English | MEDLINE | ID: mdl-26838694

ABSTRACT

AIMS: Pulmonary vein antrum isolation (PVAI) is the cornerstone of atrial fibrillation (AF) ablation. There is an ongoing discussion on whether and when to add substrate modification to PVAI. This study evaluates (1) long-term efficacy of PVAI as a primary ablation strategy in all patients independently from AF type and (2) predictors of arrhythmia recurrence. METHODS AND RESULTS: A total of 509 consecutive patients (mean age 57 years, 38.9% non-paroxysmal AF) with AF underwent PVAI. In redo procedures, ablation was restricted to re-pulmonary vein (PV) isolation in case of PV reconnection. If the PVs were found to be isolated, substrate modification was performed. In total, 774 procedures were performed. Mean follow-up duration after the first and last ablation was, respectively, 66 ± 23 and 55 ± 25 months. A single PVAI was sufficient in restoring and maintaining long-term sinus rhythm in 41.3% (n = 210) of patients. Multiple procedures (mean 1.5) with re-PV isolation increased long-term success to 58.3% (n = 297). Additional substrate modification (n = 70) increased success to 62.5% (n = 318). After the last ablation, 87.5% of patients experienced success or significant clinical improvement on or off antiarrhythmic drugs. The incidence of left-sided atrial flutter or atrial tachycardia was 5% after PVAI and increased to 32% after additional substrate modification. Independent predictors for arrhythmia recurrence after the last ablation were non-paroxysmal AF, female sex, body mass index, hypertension, and AF duration. CONCLUSION: Five-year freedom of atrial tachyarrhythmia could be achieved by PVAI as primary ablation strategy in 58.3% of patients. Additional substrate modification only moderately increased overall success.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/methods , Pulmonary Veins/surgery , Action Potentials , Aged , Anti-Arrhythmia Agents/therapeutic use , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Catheter Ablation/adverse effects , Cohort Studies , Disease-Free Survival , Female , Heart Rate , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Netherlands , Proportional Hazards Models , Pulmonary Veins/physiopathology , Recurrence , Reoperation , Risk Factors , Time Factors , Treatment Outcome
20.
J Am Heart Assoc ; 4(10): e002222, 2015 Oct 14.
Article in English | MEDLINE | ID: mdl-26467997

ABSTRACT

BACKGROUND: Inverse potential mapping (IPM) noninvasively reconstructs cardiac surface potentials using body surface potentials. This requires a volume conductor model (VCM), usually constructed from computed tomography; however, computed tomography exposes the patient to harmful radiation and lacks information about tissue structure. Magnetic resonance imaging (MRI) is not associated with this limitation and might have advantages for mapping purposes. This feasibility study investigated a magnetic resonance imaging-based IPM approach. In addition, the impact of incorporating the lungs and their particular resistivity values was explored. METHODS AND RESULTS: Three volunteers and 8 patients with premature ventricular contractions scheduled for ablation underwent 65-electrode body surface potential mapping. A VCM was created using magnetic resonance imaging. Cardiac surface potentials were estimated from body surface potentials and used to determine the origin of electrical activation. The IPM-defined origin of sinus rhythm corresponded well with the anatomic position of the sinus node, as described in the literature. In patients, the IPM-derived premature ventricular contraction focus was 3-dimensionally located within 8.3±2.7 mm of the invasively determined focus using electroanatomic mapping. The impact of lungs on the IPM was investigated using homogeneous and inhomogeneous VCMs. The inhomogeneous VCM, incorporating lung-specific conductivity, provided more accurate results compared with the homogeneous VCM (8.3±2.7 and 10.3±3.1 mm, respectively; P=0.043). The interobserver agreement was high for homogeneous (intraclass correlation coefficient 0.862, P=0.003) and inhomogeneous (intraclass correlation coefficient 0.812, P=0.004) VCMs. CONCLUSION: Magnetic resonance imaging-based whole-heart IPM enables accurate spatial localization of sinus rhythm and premature ventricular contractions comparable to electroanatomic mapping. An inhomogeneous VCM improved IPM accuracy.


Subject(s)
Body Surface Potential Mapping/methods , Heart Conduction System/physiopathology , Heart Rate , Magnetic Resonance Imaging/methods , Ventricular Premature Complexes/diagnosis , Action Potentials , Adult , Case-Control Studies , Catheter Ablation , Feasibility Studies , Female , Heart Conduction System/surgery , Humans , Male , Middle Aged , Models, Cardiovascular , Predictive Value of Tests , Reproducibility of Results , Signal Processing, Computer-Assisted , Treatment Outcome , Ventricular Premature Complexes/physiopathology , Ventricular Premature Complexes/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...