1.
Sci Rep ; 12(1): 3499, 2022 03 03.
Article in English | MEDLINE | ID: mdl-35241700

ABSTRACT

Femoral component orientation plays a key role in implant stability and therefore the success rate of total hip arthroplasty. To date, this topic has been studied using various definitions and a variety of imaging modalities and protocols. The aim of this study is a proof of concept that a new algorithm can be used to describe the femoral component's 3D orientation on the three orthogonal anatomical planes and relative to its mechanical axis using input from two orthogonal planes. CT scans of 18 patients with a total of 22 hip arthroplasties were collected. From these, orthogonal coronal and sagittal projections of the complete femur were acquired in the scanning position (MIPs) and relative to the femoral mechanical axis (corrected MIPs). On these images, the orientation of the neck of the femoral component in space and relative to the femoral axis, respectively, was measured by coronal inclination (CIF), sagittal inclination (SIF) and transverse version (TVF). With the algorithm, TVF was also calculated based on CIF and SIF. Differences between measured and calculated TVF and intra- and inter-observer reliability were evaluated using intra-class correlation coefficients (ICC). The error of non-orthogonal imaging (85° angle between the sagittal and coronal reconstructions) was tested on a third series of MIPs. The ICC between the calculated TVF and manually measured TVF, in space and relative to the femoral axis, was 0.98 for both with median absolute differences of 1.3 and 1.5°. For non-orthogonal images this was 0.70 with a median absolute difference of 5°. ICCs for intra-observer and inter-observer reliability for the calculated TVF values were 0.98 and 0.88, respectively. With this algorithm the transverse orientation of the neck of the femoral component can be assessed in space and relative to the mechanical femoral axis by combining its sagittal and coronal orientation. As long as the imaging visualizes two orthogonal planes, the orientation of an implant can be assessed in 3-D, regardless of the imaging modality.


Subject(s)
Arthroplasty, Replacement, Hip , Algorithms , Arthroplasty, Replacement, Hip/methods , Femur/diagnostic imaging , Femur/surgery , Humans , Reproducibility of Results , Tomography, X-Ray Computed/methods
2.
Arch Orthop Trauma Surg ; 142(6): 1253-1264, 2022 Jun.
Article in English | MEDLINE | ID: mdl-34101017

ABSTRACT

INTRODUCTION: Dislocation remains a major complication in total hip arthroplasty (THA), in which femoral component orientation is considered a key parameter. New imaging modalities and definitions on femoral component orientation have been introduced, describing orientation in different planes. This study aims to systematically review the relevance of the different orientation parameters on implant stability. METHODS: A systematic review was performed according to the PRISMA guidelines to identify articles in the PubMed and EMBASE databases that study the relation between any femoral component orientation parameters and implant stability in primary THA. RESULTS: After screening for inclusion and exclusion criteria and quality assessment, nine articles were included. Definitions to describe the femoral component orientation and methodologies to assess its relevance for implant stability differed greatly, with lack of consensus. Seven retrospective case-control studies reported on the relevance of the transversal plane orientation: Low femoral- or low combined femoral and acetabular anteversion was statistical significantly related with more posterior dislocations, and high femoral- or combined femoral and acetabular anteversion with anterior dislocations in two studies. There were insufficient data on sagittal and coronal component orientation in relation to implant stability. CONCLUSION: Because of incomparable definitions, limited quality and heterogeneity in methodology of the included studies, there is only weak evidence that the degree of transverse component version is related with implant stability in primary THA. Recommendations about the optimal orientation of the femoral component in all three anatomical planes cannot be provided. Future studies should uniformly define the three-dimensional orientation of the femoral component and systematically describe implant stability.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Joint Dislocations , Acetabulum/surgery , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/methods , Hip Prosthesis/adverse effects , Humans , Joint Dislocations/surgery , Retrospective Studies
3.
Bone Joint J ; 102-B(9): 1261-1267, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32862680

ABSTRACT

AIMS: The aetiologies of common degenerative spine, hip, and knee pathologies are still not completely understood. Mechanical theories have suggested that those diseases are related to sagittal pelvic morphology and spinopelvic-femoral dynamics. The link between the most widely used parameter for sagittal pelvic morphology, pelvic incidence (PI), and the onset of degenerative lumbar, hip, and knee pathologies has not been studied in a large-scale setting. METHODS: A total of 421 patients from the Cohort Hip and Cohort Knee (CHECK) database, a population-based observational cohort, with hip and knee complaints < 6 months, aged between 45 and 65 years old, and with lateral lumbar, hip, and knee radiographs available, were included. Sagittal spinopelvic parameters and pathologies (spondylolisthesis and degenerative disc disease (DDD)) were measured at eight-year follow-up and characteristics of hip and knee osteoarthritis (OA) at baseline and eight-year follow-up. Epidemiology of the degenerative disorders and clinical outcome scores (hip and knee pain and Western Ontario and McMaster Universities Osteoarthritis Index) were compared between low PI (< 50°), normal PI (50° to 60°), and high PI (> 60°) using generalized estimating equations. RESULTS: Demographic details were not different between the different PI groups. L4 to L5 and L5 to S1 spondylolisthesis were more frequently present in subjects with high PI compared to low PI (L4 to L5, OR 3.717; p = 0.024 vs L5 to S1 OR 7.751; p = 0.001). L5 to S1 DDD occurred more in patients with low PI compared to high PI (OR 1.889; p = 0.010), whereas there were no differences in L4 to L5 DDD among individuals with a different PI. The incidence of hip OA was higher in participants with low PI compared to normal (OR 1.262; p = 0.414) or high PI (OR 1.337; p = 0.274), but not statistically different. The incidence of knee OA was higher in individuals with a high PI compared to low PI (OR 1.620; p = 0.034). CONCLUSION: High PI is a risk factor for development of spondylolisthesis and knee OA. Low pelvic incidence is related to DDD, and may be linked to OA of the hip. Level of Evidence: 1b Cite this article: Bone Joint J 2020;102-B(9):1261-1267.


Subject(s)
Osteoarthritis, Hip/etiology , Osteoarthritis, Knee/etiology , Spondylolisthesis/etiology , Aged , Cohort Studies , Female , Follow-Up Studies , Humans , Incidence , Lumbar Vertebrae , Male , Middle Aged , Osteoarthritis, Hip/epidemiology , Osteoarthritis, Knee/epidemiology , Prospective Studies , Risk Factors , Spondylolisthesis/epidemiology
4.
Acta Orthop ; 91(6): 705-710, 2020 12.
Article in English | MEDLINE | ID: mdl-32835560

ABSTRACT

Background and purpose - Survivorship of total hip arthroplasty (THA) with the ultra-high molecular weight polyethylene (UHMWPE) monoblock cup has been limited due to periprosthetic osteolysis and aseptic loosening, secondary to wear of the UHMWPE. In response, a vitamin E blended highly cross-linked polyethylene (HXLPE) cup was developed. This study set out to compare the wear and clinical 6-year outcomes of vitamin E blended HXLPE with UHMWPE in an isoelastic monoblock cup in patients with hip osteoarthritis who underwent uncemented THA. The 2-year results have been reported previously. Patients and methods - For this randomized controlled trial 199 patients were included. 102 patients received the vitamin E blended HXLPE uncemented acetabular cup and 97 patients the uncemented UHMWPE monoblock cup. Clinical and radiographic parameters were obtained preoperatively, directly postoperatively, and at 3, 12, 24, and 72 months. Wear rates were compared using the femoral head penetration (FHP) rate. Results - 173 patients (87%) completed the 6-year follow-up. The mean NRS scores for rest pain, load pain, and patient satisfaction were 0.3 (SD 1), 0.6 (SD 1), and 8.6 (SD 1) respectively. The mean Harris Hip Score was 93 (SD 12). The FHP rate was lower in the vitamin E blended HXLPE cup (0.028 mm/year) compared with the UHMWPE cup (0.035 mm/year) (p = 0.002). No adverse reactions associated with the clinical application of vitamin E blended HXLPE were observed. 15 complications occurred, equally distributed between the two cups. The 6-year survival to revision rate was 98% for both cups. There was no aseptic loosening. Interpretation - This study shows the superior performance of the HXLPE blended with vitamin E acetabular cup with clinical and radiographic results similar to the UHMWPE acetabular cup.


Subject(s)
Arthroplasty, Replacement, Hip , Osteolysis , Polyethylene/pharmacology , Polyethylenes/pharmacology , Postoperative Complications , Prosthesis Design , Vitamin E/pharmacology , Acetabulum/diagnostic imaging , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/instrumentation , Arthroplasty, Replacement, Hip/methods , Female , Hip Prosthesis , Humans , Male , Middle Aged , Osteoarthritis, Hip/surgery , Osteolysis/diagnosis , Osteolysis/etiology , Osteolysis/prevention & control , Outcome Assessment, Health Care , Postoperative Complications/diagnosis , Postoperative Complications/etiology , Prosthesis Design/adverse effects , Prosthesis Design/methods , Prosthesis Failure/etiology , Radiography/methods
5.
JBJS Case Connect ; 10(1): e0466, 2020.
Article in English | MEDLINE | ID: mdl-32224646

ABSTRACT

CASE: An 84-year old woman developed 2 large seromal cysts at the medial side of her right thigh, 4 months after total knee arthroplasty (TKA). The cysts were located at the place where the tourniquet, during surgery, had been applied. The diagnosis was confirmed with echography and magnetic resonance imaging. Both cysts were resected, and the patient recovered completely, after one relapse in which a lymphatic vessel was sutured. CONCLUSION: Development of seromal cyst after tourniquet use during TKA is a rare but serious complication.


Subject(s)
Arthroplasty, Replacement, Knee , Cysts/etiology , Postoperative Complications/etiology , Seroma/etiology , Tourniquets/adverse effects , Aged, 80 and over , Cysts/surgery , Female , Humans , Recurrence , Reoperation , Seroma/surgery , Ultrasonography, Interventional
6.
Acta Orthop ; 91(3): 254-259, 2020 06.
Article in English | MEDLINE | ID: mdl-32098534

ABSTRACT

Background and purpose - The long-term survival of arthroplasty components may be limited by polyethylene wear-related problems such as periprosthetic osteolysis and aseptic loosening. Highly cross-linked polyethylene (HXLPE) blended with vitamin E was introduced to improve oxidative stability and to avoid long-term embrittlement. This study clinically compares the tribological behavior and clinical outcome of vitamin E blended HXLPE with ultra-high molecular weight polyethylene (UHMWPE) in an isoelastic monoblock cup for uncemented total hip arthroplasty.Patients and methods - In this randomized controlled trial (RCT), 199 patients were included: 102 patients received the vitamin E blended HXLPE cup, 97 patients the UHMWPE cup. Clinical and radiographic parameters were obtained preoperatively, directly postoperative and at 3, 12, and 24 months. Wear rates were compared using the mean linear femoral head penetration (FHP) rate.Results - 188 patients (94%) completed the 2-year follow-up. Mean patient satisfaction was higher in the vitamin E blended HXLPE group (8.9 [1]) than in in the control group (8.5 [2], p = 0.03). The Harris Hip Score (HHS) was higher in the vitamin E blended HXLPE group (95 [8]) than in the control group (92 [11], p = 0.3). The FHP rate was lower in the vitamin E blended HXLPE group: 0.046 mm/year compared with 0.056 mm/year in the control group (p = 0.05). No adverse reactions associated with the clinical application of vitamin E blended HXLPE were observed during follow-up, with an excellent 2-year survival to revision rate of 98% for both cups.Interpretation - This study shows the superior performance of the HXLPE blended with vitamin E acetabular cup with lower linear femoral head penetration rates and better clinical results compared with the UHMWPE acetabular cup after 2 years.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Hip Prosthesis , Polyethylene/therapeutic use , Polyethylenes/therapeutic use , Vitamin E/therapeutic use , Acetabulum/surgery , Adult , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/instrumentation , Female , Hip Prosthesis/adverse effects , Humans , Male , Middle Aged , Prosthesis Design , Prosthesis Failure , Single-Blind Method , Young Adult
7.
J Orthop ; 16(5): 396-399, 2019.
Article in English | MEDLINE | ID: mdl-31110402

ABSTRACT

BACKGROUND: Total hip arthroplasty (THA) is a very successful procedure in orthopedics. Still polyethylene wear and gait deficits are limiting the clinical success.It is important to reconstruct leg length (LL) and femoral offset (FO) anatomically in order to have the best possible result of a THA. Gait deficits can arise due to leg length discrepancy as well as changes in the abductor moment arm. In THA, LL and FO are strongly determined by the orientation, size and geometry of the femoral stem. METHODS: This radio-anatomical study used the data of a prospective cases series of 112 patients who underwent 126 primary THAs and had completed a 1-year follow-up examination. FO and LL were compared between the conventional straight stem in vivo and a computed simulated implantation of a short curved stem, using the pre- and postoperative pelvic radiographs of the same patients. RESULTS: In this simulation of the short curved stem statistically significantly restored native FO (p = 0.010) and LL (p = 0.000) better, compared to the conventional straight stem. CONCLUSIONS: Thus, the short curved stem restores FO and LL better, and could potentially prevent gait deficits.

8.
Acta Orthop ; 90(5): 455-459, 2019 10.
Article in English | MEDLINE | ID: mdl-31132902

ABSTRACT

Background and purpose - The preferred treatment of an acute prosthetic joint infection (PJI) is debridement, antibiotics, irrigation and retention of the prosthesis (DAIR). The antibiotic treatment consists of an empirical and targeted phase. In the empirical phase, intravenous antibiotics are started after surgery before micro-organisms are determined in microbiological cultures. Which empirical antibiotic is used differs between hospitals, partly reflecting geographic differences in susceptibility spectrums. We investigated whether flucloxacillin should remain the antibiotic of choice in our hospital for empiric treatment of acute PJI with DAIR. Patients and methods - We retrospectively analyzed 91 patients treated for PJI with DAIR between 2012 and 2016. The susceptibility of micro-organisms was determined in multiple cultures of periprosthetic tissue and synovial fluid for 3 antibiotics: amoxicillin/clavulanic acid, cefazolin, and flucloxacillin. Results - Positive microbiological cultures from 68 patients were analyzed. Staphylococcus aureus was the predominant pathogen, cultured in half of the patients. In one-third of patients more than 1 micro-organism was found. On a patient level, the data showed that 65% were responsive to flucloxacillin, 76% to amoxicillin/clavulanic acid, and 79% to cefazolin. Interpretation - Flucloxacillin appeared to be a suboptimal choice in our patient population treated with DAIR. We therefore changed our practice to cefazolin as the preferred antibiotic in the empirical treatment of acute PJI with DAIR.


Subject(s)
Anti-Bacterial Agents/therapeutic use , Hip Prosthesis/adverse effects , Knee Prosthesis/adverse effects , Practice Patterns, Physicians'/statistics & numerical data , Prosthesis-Related Infections/drug therapy , Acute Disease , Aged , Aged, 80 and over , Amoxicillin-Potassium Clavulanate Combination/therapeutic use , Antibiotic Prophylaxis/methods , Cefazolin/therapeutic use , Clinical Decision-Making/methods , Combined Modality Therapy/methods , Debridement , Female , Floxacillin/therapeutic use , Humans , Male , Microbial Sensitivity Tests , Middle Aged , Netherlands , Prosthesis-Related Infections/etiology , Retrospective Studies , Staphylococcal Infections/drug therapy