Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
J Bone Joint Surg Am ; 98(16): 1359-69, 2016 Aug 17.
Article in English | MEDLINE | ID: mdl-27535438

ABSTRACT

BACKGROUND: In revision total knee arthroplasty (TKA), the femoral component and tibial baseplate are usually cemented. However, stems can be fixed either with cement or with a press-fit technique, with the latter resulting in hybrid fixation. There is no consensus on the preferred stem fixation technique. Therefore, we compared the stability of cemented TKA implants with the stability of TKA implants fixed with the hybrid technique in a prospective randomized trial using radiostereometric analysis (RSA). METHODS: Thirty-two patients with a Type-I or II bone defect who needed revision TKA and were randomly allocated at the time of surgery into either the cemented or hybrid-fixation group were included in the study. The radiographs for the RSA were obtained during hospitalization (baseline); at 6 weeks; and at 3, 6, 12, and 24 months. Migration of the femoral and tibial implants was measured using model-based RSA and expressed along or around the 3 orthogonal axes and as total translation (TT) and total rotation (TR). Clinical results were evaluated using the Knee Society Score (KSS), the Knee injury and Osteoarthritis Outcome Score (KOOS), active flexion, and visual analog scale (VAS) scores for pain and satisfaction. Mann-Whitney and chi-square tests were used to compare migration and clinical outcomes between the cement and hybrid techniques. RESULTS: At 24 months, no difference in median migration or the number of migrating components was found between the cemented and hybrid-fixation groups. In each group, approximately one-third of the tibial components had total rotation of >1°. The clinical scores did not differ between the techniques. CONCLUSIONS: At 24 months after revision TKAs, cemented and hybrid-fixation replacements were equally stable. Unexpectedly, both groups had implants with >1 mm or >1° of micromotion although there were no clinical or radiographic signs of loosening. Whether these findings indicate the possibility of loosening with longer follow-up remains to be investigated. LEVEL OF EVIDENCE: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Knee Joint/surgery , Knee Prosthesis , Orthopedic Procedures/methods , Aged , Bone Cements , Cementation , Female , Humans , Knee Joint/diagnostic imaging , Male , Middle Aged , Osteoarthritis, Knee/diagnostic imaging , Osteoarthritis, Knee/surgery , Radiostereometric Analysis , Range of Motion, Articular/physiology , Reoperation , Treatment Outcome
2.
Knee Surg Sports Traumatol Arthrosc ; 24(10): 3235-3241, 2016 Oct.
Article in English | MEDLINE | ID: mdl-26215774

ABSTRACT

PURPOSE: Revision of the severe stiff total knee arthroplasty (TKA) is challenging, and clinical outcome is inferior to other indications for revision. The purpose of the present study was to determine clinical outcome of TKA revision in patients with severe stiffness (range of motion (ROM) ≤ 70°) and evaluate a possible influence of accompanying findings, such as component malposition, aseptic loosening or instability. METHODS: A prospective cohort of 40 patients with a preoperative ROM ≤ 70° and a minimum of 2-year follow-up after total system revision (Genesis or Legion stemmed condylar implant) was evaluated. ROM, Knee Society Scoring System (KSS) and visual analogue scale (VAS) pain scores were obtained preoperatively and at 2 years. Patient satisfaction and complication rate were assessed. Component malposition was most frequently reported as accompanying finding (n = 27). Comparisons between pre- and postoperative outcome (p < 0.05) and between different subgroups (component malposition, aseptic loosening, and instability) based on accompanying findings were made (no statistical comparison). RESULTS: ROM, KSS and VAS pain scores improved significantly (p < 0.001): median ROM at two years 85° (range 10-125) and median gain 25° (range -10 to +85). Median VAS satisfaction was 53.5 points (range 15-98). Seventeen patients reported at least one complication, including one re-revision. Six patients underwent manipulation under anaesthesia, and five were referred to the pain clinic. No clear differences between subgroups were observed. CONCLUSIONS: TKA revision in patients with severe stiffness resulted in a moderate but significant improved clinical outcome after 2 years. Accompanying abnormalities such as component malposition, aseptic loosening or instability did not influence clinical outcome. Realistic patient counselling on the moderate outcome and possible remaining limitations in daily life might help to improve patient satisfaction. LEVEL OF EVIDENCE: Therapeutic studies-case series with no comparison group, Level IV.


Subject(s)
Arthroplasty, Replacement, Knee/adverse effects , Knee Joint/physiopathology , Range of Motion, Articular/physiology , Reoperation , Cohort Studies , Female , Follow-Up Studies , Humans , Knee Joint/surgery , Male , Middle Aged , Patient Satisfaction , Visual Analog Scale
3.
Bone Joint J ; 97-B(6): 780-5, 2015 Jun.
Article in English | MEDLINE | ID: mdl-26033057

ABSTRACT

We evaluated the accuracy with which a custom-made acetabular component could be positioned at revision arthroplasty of the hip in patients with a Paprosky type 3 acetabular defect. A total of 16 patients with a Paprosky type 3 defect underwent revision surgery using a custom-made trabecular titanium implant. There were four men and 12 women with a median age of 67 years (48 to 79). The planned inclination (INCL), anteversion (AV), rotation and centre of rotation (COR) of the implant were compared with the post-operative position using CT scans. A total of seven implants were malpositioned in one or more parameters: one with respect to INCL, three with respect to AV, four with respect to rotation and five with respect to the COR. To the best of our knowledge, this is the first study in which CT data acquired for the pre-operative planning of a custom-made revision acetabular implant have been compared with CT data on the post-operative position. The results are encouraging.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Aged , Arthroplasty, Replacement, Hip/methods , Female , Humans , Male , Middle Aged , Reoperation
4.
Bone Joint J ; 97-B(2): 160-3, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25628276

ABSTRACT

The long-term survival of the cementless Spotorno CLS femoral component in patients aged > 50 years at the time of arthroplasty was investigated. Survivorship analysis of a consecutive series of 85 patients (100 hips; under 50 years of age at a mean follow-up of 18.4 years (16.3 to 20.8)) was performed. The clinical and radiographic outcomes were satisfactory. The overall rate of survival of the femoral component was 93.5% (95% confidence interval (CI), 90.9 to 96.1) after 19 years. Survival with revision for aseptic loosening as the end point was 95.7% (95% CI 93.6 to 97.8%) at 19 years. This study demonstrates an excellent long-term survival of the Spotorno CLS femoral component after 16 to 20 years in young patients undergoing total hip arthroplasty.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Adolescent , Adult , Equipment Failure Analysis , Female , Femur , Follow-Up Studies , Hip Dislocation, Congenital/surgery , Humans , Male , Middle Aged , Osteoarthritis, Hip/surgery , Prosthesis Design , Reoperation , Young Adult
5.
J Orthop Traumatol ; 16(1): 15-20, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25245630

ABSTRACT

BACKGROUND: A dual mobility cup has the theoretic potential to improve stability in primary total hip arthroplasty (THA) and mid-term cohort results are favorable. We hypothesized that use of a new-generation dual mobility cup in revision arthroplasty prevents dislocation in patients with a history of recurrent dislocation of the THA. MATERIALS AND METHODS: We performed a retrospective cohort study of patients receiving an isolated acetabular revision with a dual mobility cup for recurrent dislocation of the prosthesis with a minimum follow-up of 1 year. Kaplan-Meier survival analyses were performed with dislocation as a primary endpoint and re-revision for any reason as a secondary endpoint. RESULTS: Forty-nine consecutive patients (50 hips) were included; none of the patients was lost to follow-up. The median follow-up was 29 months (range 12-66 months). Two patients died from unrelated causes. Survival after 56 months was 100 % based on dislocation and 93 % (95 % CI 79-98 %) based on re-revision for any reason. Radiologic analysis revealed no osteolysis or radiolucent lines around the acetabular component during the follow-up period. CONCLUSION: The dual mobility cup is an efficient solution for instability of THA with a favorable implant survival at 56 months. LEVEL OF EVIDENCE: Level 4, retrospective case series.


Subject(s)
Acetabulum/surgery , Arthroplasty, Replacement, Hip/methods , Hip Dislocation/surgery , Hip Prosthesis , Female , Follow-Up Studies , Hip Dislocation/physiopathology , Humans , Male , Prosthesis Design , Prosthesis Failure , Reoperation , Retrospective Studies , Time Factors
6.
J Bone Joint Surg Am ; 96(10): e81, 2014 May 21.
Article in English | MEDLINE | ID: mdl-24875033

ABSTRACT

BACKGROUND: An important factor in the functional results after total knee arthroplasty is the achieved maximal flexion. The main purpose of this study was to compare the maximal knee flexion one year after surgery in patients who received either the bicruciate substituting knee system or the conventional posterior stabilized system. METHODS: In a prospective randomized controlled trial, 124 patients presenting with osteoarthritis received the bicruciate substituting or the conventional posterior stabilized prosthesis. The primary outcome was the maximum flexion angle at one year postoperatively on a lateral radiograph made with the supine patient using manual force to bend the knee. Secondary outcomes were active flexion (lying and standing), the Knee Society Score, the Patella Scoring System score, the University of California Los Angeles score, the number and type of adverse device effects, and visual analog scale satisfaction up to two years postoperatively. The outcome measures of both groups were compared using one-sided t tests and non-parametric alternatives, with a significance level of p < 0.05. RESULTS: No significant differences between the two groups were observed in maximal flexion on radiographs and in active flexion at baseline. The median maximal flexion on radiographs was 127° (range, 83° to 150°) for the bicruciate substituting group and 125° (range, 74° to 145°) for the conventional posterior stabilized group. The two groups showed comparable two-year results with respect to the Knee Society Score, the Patella Scoring System, the University of California Los Angeles score, and visual analog scale satisfaction. In the bicruciate substituting group, forty-one adverse device effects in twenty-six patients were reported, including three total system revisions and fourteen manipulations under anesthesia, compared with the conventional posterior stabilized group, in which sixteen adverse device effects were observed in thirteen patients, including six manipulations under anesthesia (p = 0.012). CONCLUSIONS: Patients who receive a bicruciate substituting system compared with those who receive a conventional posterior stabilized system have comparable knee flexion characteristics and clinical and functional outcomes but more complications by two years after total knee arthroplasty. LEVEL OF EVIDENCE: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.


Subject(s)
Arthroplasty, Replacement, Knee/instrumentation , Knee Prosthesis , Osteoarthritis, Knee/surgery , Prosthesis Design , Humans , Operative Time , Osteoarthritis, Knee/physiopathology , Postoperative Complications/etiology , Prospective Studies , Range of Motion, Articular , Treatment Outcome
7.
Knee ; 15(4): 336-8, 2008 Aug.
Article in English | MEDLINE | ID: mdl-18514528

ABSTRACT

The prevalence of pulmonary tuberculosis is increasing and is associated with a rise in skeletal tuberculosis. Even after appropriate anti-tuberculosis therapy, reactivation of the infection may occur, even after many years. In this case report we describe a patient who had a reactivation of tuberculosis in the knee after total knee arthroplasty. At the age of 14 years, the patient had isolated tuberculosis arthritis of the left knee. Reactivation occurred after total knee arthroplasty 61 years later, at the age of 75. The patient was treated with a combined therapy; first the joint was irrigated with povidine-iodine and saline solution, and gentamicin beads were left behind. When the cultures revealed Mycobacterium tuberculosis, drug therapy of isoniazid, rifampicin, ethambutol and pyrazinamide was started and was continued for 9 months postoperatively. At a recent follow-up, the patient is doing well, with good range of motion in the knee.


Subject(s)
Arthritis, Infectious/diagnosis , Arthritis, Infectious/etiology , Arthroplasty, Replacement, Knee/adverse effects , Knee Joint , Tuberculosis, Osteoarticular/diagnosis , Tuberculosis, Osteoarticular/etiology , Aged , Arthritis, Infectious/therapy , Female , Humans , Recurrence , Time Factors , Tuberculosis, Osteoarticular/therapy
8.
Knee Surg Sports Traumatol Arthrosc ; 15(8): 1019-22, 2007 Aug.
Article in English | MEDLINE | ID: mdl-17437082

ABSTRACT

Goal of this study is to determine the anterior-posterior laxity in 30 degrees of knee flexion for a posterior cruciate retaining total knee arthroplasty with a relative dished insert and implanted with a ligament tensor. Furthermore, the correlation between these AP laxities and the postoperative range of motion (ROM) and postoperative Knee Society Score (KSS) is analysed. Fifty-one balanSys total knee arthroplasties were performed in 49 patients between 1998 and 2000. These arthroplasties are analysed with respect to AP laxity (Rolimeter), ROM and KSS with a mean follow-up of 4.6 years. The mean anterior laxity is 2.8 mm with no posterior laxities at all. The average postoperative ROM is 110 degrees with an average KSS of 142. No correlations between AP-laxity and postoperative ROM or between AP-laxity and postoperative KSS are found. A posterior cruciate retaining TKA with a relative dished insert and implanted with a tensor is very stable in the anterior-posterior direction in 30 degrees of knee flexion. This limited laxity does not seem to disadvantage the mean postoperative ROM and KSS, when compared to other TKA studies.


Subject(s)
Arthroplasty, Replacement, Knee/instrumentation , Joint Instability/etiology , Knee Joint/physiopathology , Postoperative Complications , Range of Motion, Articular/physiology , Aged , Aged, 80 and over , Female , Femur/surgery , Follow-Up Studies , Humans , Joint Prosthesis , Male , Middle Aged , Posterior Cruciate Ligament/physiopathology , Prosthesis Design , Surface Properties , Tibia/surgery
9.
Knee ; 13(6): 430-4, 2006 Dec.
Article in English | MEDLINE | ID: mdl-16956763

ABSTRACT

In this retrospective cohort, the results of step-cut tibial tubercle osteotomy (TTO) in 39 revision total knee arthroplasty, using the Continuum Knee System (CKS), are determined. In 39 revision, total knee arthroplasties, adequate exposure was obtained after step-cut TTO. All knees were recently reviewed for clinical and radiological results. Symptomatic TTO-related complications occurred in three out of 39 patients. Two patients had proximal migration of the tibial tubercle due to an insufficient step-cut. Another patient had posttraumatic avulsion of the tibial tubercle. No TTO-related extensor lag or tibial fracture occurred We conclude that, when adequate exposure cannot be obtained, step-cut TTO is a safe and reproducible procedure if strict attention is paid to technique and fixation. It does not compromise the functional results of TKA.


Subject(s)
Arthroplasty, Replacement, Knee , Osteotomy/methods , Tibia/surgery , Adult , Aged , Arthritis, Rheumatoid/surgery , Cohort Studies , Female , Follow-Up Studies , Humans , Knee Joint/diagnostic imaging , Knee Joint/surgery , Male , Middle Aged , Osteoarthritis, Knee/surgery , Radiography , Reoperation/methods , Retrospective Studies , Treatment Outcome
10.
J Bone Joint Surg Br ; 87(7): 911-5, 2005 Jul.
Article in English | MEDLINE | ID: mdl-15972901

ABSTRACT

We report the long-term results of 51 pelvic osteotomies in 43 patients with a mean follow-up of 15 years (13 to 20). The mean age of the patients was 28 years (14 to 46). At review three patients were lost to follow-up, and six had received a total hip arthroplasty. Of 48 hips, 42 (88%) were preserved, with good to excellent clinical results in 27 (64%). Pre-operatively, 41 (80%) of the treated hips had shown no sign of osteoarthritis. Thirty-one (65%) hips showed no progression of osteoarthritis after follow-up for 15 years. Significant negative factors for good long-term results were the presence of osteoarthritic changes and a fair or poor clinical score pre-operatively. Pelvic reorientation osteotomy for symptomatic hip dysplasia can give satisfactory and reproducible long-term clinical results.


Subject(s)
Acetabulum/surgery , Bone Diseases, Developmental/surgery , Osteotomy/methods , Pelvis/surgery , Acetabulum/diagnostic imaging , Adolescent , Adult , Arthroplasty, Replacement, Hip/methods , Bone Diseases, Developmental/diagnostic imaging , Female , Follow-Up Studies , Humans , Male , Middle Aged , Osteotomy/adverse effects , Pelvis/diagnostic imaging , Radiography , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...