N Engl J Med ; 389(16): 1477-1487, 2023 Oct 19.
Article in English | MEDLINE | ID: mdl-37634149

ABSTRACT

BACKGROUND: Imaging-guided percutaneous coronary intervention (PCI) is associated with better clinical outcomes than angiography-guided PCI. Whether routine optical coherence tomography (OCT) guidance in PCI of lesions involving coronary-artery branch points (bifurcations) improves clinical outcomes as compared with angiographic guidance is uncertain. METHODS: We conducted a multicenter, randomized, open-label trial at 38 centers in Europe. Patients with a clinical indication for PCI and a complex bifurcation lesion identified by means of coronary angiography were randomly assigned in a 1:1 ratio to OCT-guided PCI or angiography-guided PCI. The primary end point was a composite of major adverse cardiac events (MACE), defined as death from a cardiac cause, target-lesion myocardial infarction, or ischemia-driven target-lesion revascularization at a median follow-up of 2 years. RESULTS: We assigned 1201 patients to OCT-guided PCI (600 patients) or angiography-guided PCI (601 patients). A total of 111 patients (18.5%) in the OCT-guided PCI group and 116 (19.3%) in the angiography-guided PCI group had a bifurcation lesion involving the left main coronary artery. At 2 years, a primary end-point event had occurred in 59 patients (10.1%) in the OCT-guided PCI group and in 83 patients (14.1%) in the angiography-guided PCI group (hazard ratio, 0.70; 95% confidence interval, 0.50 to 0.98; P = 0.035). Procedure-related complications occurred in 41 patients (6.8%) in the OCT-guided PCI group and 34 patients (5.7%) in the angiography-guided PCI group. CONCLUSIONS: Among patients with complex coronary-artery bifurcation lesions, OCT-guided PCI was associated with a lower incidence of MACE at 2 years than angiography-guided PCI. (Funded by Abbott Vascular and others; OCTOBER ClinicalTrials.gov number, NCT03171311.).


Subject(s)
Coronary Angiography , Coronary Artery Disease , Percutaneous Coronary Intervention , Tomography, Optical Coherence , Humans , Coronary Angiography/adverse effects , Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/methods , Tomography, Optical Coherence/adverse effects , Tomography, Optical Coherence/methods , Treatment Outcome , Europe
2.
Int J Cardiol ; 283: 84-87, 2019 05 15.
Article in English | MEDLINE | ID: mdl-30449693

ABSTRACT

Percutaneous recanalization of coronary chronic total occlusions (CTOs) traditionally relies on the use of dual access and large bore catheters, with trans-femoral approach adoption in most of the cases. Aim of this manuscript is to describe an alternative algorithm, that we called "Minimalistic Hybrid Algorithm", in order to minimize the use of double access, large bore catheters, and femoral approach thus reducing patient's discomfort and possibly procedural complications. This algorithm can be interpreted as an evolution of the classic "Hybrid Algorithm" and requires the operator to be confident with all techniques known in this conventional algorithm. Indeed, all possible techniques and approaches of the conventional hybrid approach to treat CTOs are included in a novel diagram for procedural strategy, which offers an alternative sequence of steps to limit, whenever possible, the invasiveness of the procedure. After dividing the cases in "simple" or "complex" CTO lesions according to the available complexity scores and to the "feeling", knowledge and expertise of the operator, a systematic description of the procedural steps is provided. This includes antegrade and retrograde approaches, as well as sub-intimal and intra-luminal techniques, in order to maintain the simpler single-catheter transradial strategies in the first line for the simple CTO, and the adoption of more complex, double access and transfemoral ones in the further steps. The minimalistic hybrid algorithm herein described is a possible alternative sequence of steps in the setting of CTO recanalization, with the potential of limiting the use of double access, large bore catheters, and femoral approach.


Subject(s)
Algorithms , Coronary Occlusion/surgery , Minimally Invasive Surgical Procedures/methods , Percutaneous Coronary Intervention/methods , Chronic Disease , Coronary Angiography , Coronary Occlusion/diagnosis , Femoral Artery , Humans , Radial Artery
3.
Catheter Cardiovasc Interv ; 92(5): E299-E307, 2018 11 01.
Article in English | MEDLINE | ID: mdl-29411523

ABSTRACT

BACKGROUND: Coronary chronic total occlusions (CTO) usually coexist with diffusely diseased coronary segments proximal and/or distal to the CTO segment. During percutaneous treatment of CTO, multiple overlapping stents are often needed to treat these long lesions. OBJECTIVES: Aim of this study is to report the first use of long, tapered coronary sirolimus-eluting stents (SES) in this setting. METHODS AND RESULTS: This is a retrospective analysis of 100 consecutive patients undergoing CTO recanalization following the hybrid algorithm. Procedural success rate was 89% (11 failures). Among the successful cases, "conventional" drug-eluting stents(DES) were used in 40(44.9%) patients, while in 49(55%) patients long-tapered SES were attempted with a success rate of 98% (1 cross-over to regular stents). Total stent length in the long-tapered DES group was higher compared to the "conventional" stenting group (76 ± 28 mm vs 46 ± 22 mm, P < .001), with a similar total number of stent (1.6 ± 0.8 vs 1.9 ± 0.8). At quantitative coronary analysis, proximal and distal segment involvement was more extended in patients undergoing long-tapered stenting, with longer overall lesion length. No differences in periprocedural complications and clinical outcomes at a mean follow-up of 303 ± 179 days were observed. CONCLUSIONS: The use of long tapered coronary DES is technically feasible and safe for the percutaneous treatment of CTOs, especially for patients presenting with long lesions.


Subject(s)
Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon, Coronary/instrumentation , Cardiovascular Agents/administration & dosage , Coronary Occlusion/therapy , Drug-Eluting Stents , Sirolimus/administration & dosage , Aged , Cardiovascular Agents/adverse effects , Chronic Disease , Coronary Occlusion/diagnostic imaging , Coronary Occlusion/physiopathology , Female , Humans , Male , Middle Aged , Prosthesis Design , Retrospective Studies , Sirolimus/adverse effects , Time Factors , Treatment Outcome , Vascular Patency
4.
Intensive Care Med ; 35(11): 1893-9, 2009 Nov.
Article in English | MEDLINE | ID: mdl-19639300

ABSTRACT

INTRODUCTION: Microcirculatory abnormalities are frequently observed in patients with severe heart failure and correlate to worse outcomes. We tested the hypothesis that nitroglycerin dose-dependently improves perfusion in severe heart failure and that this could be monitored by measuring central-peripheral temperature gradient and with Sidestream Dark Field imaging of the sublingual mucosa. METHODS: A dose-response study was performed in 17 patients with cardiogenic shock (n = 9) or end-stage chronic heart failure (n = 8) admitted to Erasmus University Medical Center. We did hemodynamic measurements at baseline and during increasing infusion rates of nitroglycerin (up to a maximum dose of 133 microg min(-1)). As parameters of tissue perfusion, we measured central-peripheral temperature gradient (delta-T) and sublingual perfused capillary density (PCD). RESULTS: Nitroglycerin dose-dependently decreased mean arterial pressure (p < 0.001) and cardiac filling pressures (both central venous pressure (CVP) and pulmonary capillary wedge pressure: p < 0.001). It increased cardiac index (p = 0.01). Nitroglycerin decreased delta-T (p < 0.001) and increased sublingual PCD (p < 0.001). Significant changes in delta-T and PCD occurred earlier, i.e., at a lower doses of NTG, than changes in global hemodynamics. Macrohemodynamic and microcirculatory responses to nitroglycerin infusion were consistent in patients with either cardiogenic shock or end-stage chronic heart failure. Changes in microcirculatory parameters occurred independently of changes in cardiac index. CONCLUSIONS: Nitroglycerin dose-dependently increases tissue perfusion in patients with severe heart failure, as observed by a decrease in central-peripheral temperature gradient and an increase in sublingual perfused capillary density.


Subject(s)
Heart Failure/drug therapy , Microcirculation/drug effects , Nitroglycerin/administration & dosage , Shock, Cardiogenic/drug therapy , Vasodilator Agents/administration & dosage , Aged , Analysis of Variance , Chronic Disease , Dose-Response Relationship, Drug , Drug Monitoring , Female , Heart Failure/diagnosis , Heart Failure/metabolism , Heart Failure/physiopathology , Humans , Infusions, Intravenous , Male , Middle Aged , Mouth Floor/blood supply , Mouth Floor/drug effects , Nitric Oxide/metabolism , Nitroglycerin/pharmacology , Shock, Cardiogenic/diagnosis , Shock, Cardiogenic/metabolism , Shock, Cardiogenic/physiopathology , Single-Blind Method , Statistics, Nonparametric , Stroboscopy , Treatment Outcome , Vasodilator Agents/pharmacology