1.
Cardiol Ther ; 11(4): 523-530, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36074260

ABSTRACT

INTRODUCTION: Guidelines recommend lifelong follow-up with transthoracic echocardiograms (TTE) for patients who had a patent ductus arteriosus (PDA) device closure via catheterization. The goal of this study was to determine the utility of follow-up TTE in patients who underwent an uncomplicated PDA device closure during infancy. METHODS: Chart review was performed on patients who had a PDA closure at not more than 1 year of age between January 1, 2002 and June 1, 2020. Patients were excluded if they had other congenital heart disease, did not have a follow-up TTE at least 3 months after procedure, or had a velocity greater than 2.0 m/s in the left pulmonary artery (LPA) or descending aorta (DAo) on the first TTE at least 3 months after device placement. Time points included the first TTE after the procedure, first TTE at least 3 months after procedure, and the most recent TTE. RESULTS: Total of 147 infants met the inclusion criteria. Age and weight at initial procedure were 141 ± 217 days and 4.2 ± 2.8 kg. There was no significant difference in DAo velocity between initial and most recent TTE. LPA velocity and left ventricular diastolic Z score significantly decreased between initial and most recent TTE. Seventy-eight patients had repeat echocardiograms more than 1 year after PDA procedure with no change in clinical management. No patient underwent an intervention on the LPA or DAo for stenosis. CONCLUSION: In patients who underwent an uncomplicated PDA closure during infancy, TTE parameters either stayed stable or improved over time. These findings need to be corroborated in larger studies with longer follow-up. If verified, the long-term TTE guidelines may need to be simplified for this patient population.

2.
Cardiol Ther ; 11(3): 445-452, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35780440

ABSTRACT

INTRODUCTION: Guidelines recommend lifelong follow-up with transthoracic echocardiograms (TTE) for patients who had a patent ductus arteriosus (PDA) device closure via catheterization. The goal of this study was to determine the utility of follow-up TTE in patients who underwent an uncomplicated PDA device closure after infancy. METHODS: Chart review was performed on patients who had a PDA closure ≥ 1 year of age between 1/1/2002 and 6/1/2020. Patients were excluded if they had other congenital heart disease, did not have a follow-up TTE ≥ 6 months after procedure, had a residual PDA or velocity > 2.0 m/s in the left pulmonary artery (LPA) or descending aorta (DAo) on the first TTE ≥ 6 months after device placement. Time points included the initial TTE after the procedure, first TTE ≥ 6 months after procedure, and the most recent TTE. RESULTS: A total of 189 patients met the study criteria. The median age and weight at initial procedure were 2.7 (1.0-64.7) years and 12.5 (3.4-69.2) kg. Most recent TTE was performed 2.0 (0.4-17.0) years after PDA closure. There were no significant differences in fractional shortening (36.4 ± 5.0% vs. 36.9 ± 5.6%) or LPA velocity (1.1 ± 0.4 m/s vs. 1.1 ± 0.4 m/s) from initial to most recent TTE, respectively. Left ventricular internal diastolic diameter Z-score significantly decreased (1.4 ± 1.8 vs. - 0.01 ± 1.2, p < 0.01) and DAo peak velocity significantly increased (1.2 ± 0.3 m/s vs. 1.3 ± 0.3 m/s, p = 0.02) from initial to most recent TTE, respectively. No patient died or underwent an intervention on the LPA or DAo for stenosis. Seventy-five patients had a total of 208 repeat TTE > 1 year after PDA procedure with no change in clinical management. CONCLUSIONS: In patients who underwent an uncomplicated PDA closure after infancy, TTE parameters improved or stayed within normal limits on the most recent TTE. Repeat lifetime TTEs after 1-year post-device placement in this population may not necessarily be needed if there are no clinical concerns.

SELECTION OF CITATIONS
SEARCH DETAIL
...