Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Publication year range
1.
Ned Tijdschr Geneeskd ; 162: D1553, 2018.
Article in Dutch | MEDLINE | ID: mdl-29350116

ABSTRACT

A 69-year-old man came to our emergency department with nausea, vomiting and upper abdominal pain under the suspicion of an ileus. Four weeks before he had had an elective aortic valve replacement. The basal thoracic slides of the abdominal CT-scan revealed a significant amount of pericardial effusion, after which the patient was referred for emergency cardiac surgery. Abdominal complaints are rarely the primary symptoms of severe heart failure.


Subject(s)
Abdominal Pain/etiology , Heart Valve Prosthesis Implantation/adverse effects , Pericardial Effusion/etiology , Aged , Aortic Valve , Elective Surgical Procedures/adverse effects , Heart Valve Prosthesis , Humans , Male , Nausea/etiology , Pericardial Effusion/surgery , Vomiting/etiology
2.
Int J Cardiol ; 179: 539-45, 2015 Jan 20.
Article in English | MEDLINE | ID: mdl-25466563

ABSTRACT

OBJECTIVES: We sought to investigate the role of balloon size during pre-implantation valvuloplasty in predicting AR and optimal Medtronic CoreValve (MCS) implantation depth. BACKGROUND: Paravalvular aortic regurgitation (AR) is common following MCS implantation. A number of anatomical and procedural variables have been proposed as determinants of AR including degree of valve calcification, valve undersizing and implantation depth. METHODS: We conducted a multicenter retrospective analysis of 282 patients who had undergone MCS implantation with prior cardiac CT annular sizing between 2007 and 2011. Native valve minimum (Dmin), maximum (Dmax) and arithmetic mean (Dmean) annulus diameters as well as agatston calcium score were recorded. Nominal and achieved balloon size was also recorded. AR was assessed using contrast angiography at the end of each procedure. Implant depth was measured as the mean distance from the nadir of the non- and left coronary sinuses to the distal valve frame angiographically. RESULTS: 29 mm and 26 mm MCS were implanted in 60% and 39% of patients respectively. The majority of patients (N=165) developed AR <2 following MCS implantation. AR ≥3 was observed in 16% of the study population. High agatston calcium score and Dmean were found to be independent predictors of AR ≥3 in multivariate analysis (P<0.0001). Nominal balloon diameter and the number of balloon inflations did not influence AR. However a small achieved balloon diameter-to-Dmean ratio (≤0.85) showed modest correlation with AR ≥3 (P=0.04). This observation was made irrespective of the degree of valve calcification. A small MCS size-to-Dmean ratio is also associated with AR ≥3 (P=0.001). A mean implantation depth of ≥8+2mm was also associated with AR ≥3. Implantation depth of ≥12 mm was associated with small MCS diameter-to-Dmean ratio and increased 30-day mortality. CONCLUSION: CT measured aortic annulus diameter and agatston calcium score remain important predictors of significant AR. Other procedural predictors include valve undersizing and low implantation depth. A small achieved balloon diameter-to-Dmean ratio might also predict AR ≥3. Our findings confirm that a small achieved balloon size during pre-implantation valvuloplasty predicts moderate-severe AR in addition to previously documented factors.


Subject(s)
Aortic Valve Insufficiency/etiology , Aortic Valve Stenosis/surgery , Aortic Valve/pathology , Calcinosis/surgery , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Stenosis/diagnostic imaging , Calcinosis/diagnostic imaging , Contrast Media , Coronary Angiography , Female , Humans , Male , Prosthesis Design , Retrospective Studies , Tomography, X-Ray Computed
3.
Neth Heart J ; 20(1): 16-23, 2012 Jan.
Article in English | MEDLINE | ID: mdl-22167520

ABSTRACT

AIMS: To assess treatment decision and outcome in patients referred for transcatheter aortic valve implantation (TAVI) in addition to predictive factors of mortality after TAVI. METHODS: Three-centre prospective observational study including 358 patients. Endpoints were defined according to the Valve Academic Research Consortium. RESULTS: Of the 358 patients referred for TAVI, TAVI was performed in 235 patients (65%), surgical aortic valve replacement (AVR) in 24 (7%) and medical therapy (MT) in 99 (28%). Reasons to decline TAVI in favour of AVR/MT were patient preference (29%), peripheral vascular disease (15%) and non-severe aortic stenosis (11%). The logistic EuroSCORE was significantly higher in patients who underwent TAVI and MT in comparison with those undergoing AVR (19 vs. 10%, p = 0.007). At 30 days, all-cause mortality and the combined safety endpoint were 9 and 24% after TAVI and 8 and 25% after AVR, respectively. All-cause mortality was significantly lower in the TAVI group compared with the MT group at 6 months, 1 year and 2 years (12% vs. 22%, 21% vs. 33% and 31% vs. 55%, respectively, p < 0.001). Multivariable analysis revealed that blood transfusion (HR: 1.19; 95% CI: 1.05-1.33), pre-existing renal failure (HR: 1.18; 95% CI: 1.06-1.33) and STS score (HR: 1.06; 95% CI: 1.02-1.10) were independent predictors of mortality at a median of 10 (IQR: 3-23) months after TAVI. CONCLUSIONS: Approximately two-thirds of the patients referred for TAVI receive this treatment with gratifying short- and long-term survival. Another 7% underwent AVR. Prognosis is poor in patients who do not receive valve replacement therapy.

SELECTION OF CITATIONS
SEARCH DETAIL
...