Australas J Ultrasound Med ; 23(4): 210-219, 2020.
Article in English | MEDLINE | ID: mdl-34765407

ABSTRACT

A patent foramen ovale (PFO) is a common remnant of fetal circulation present in up to 25% of the worldwide adult population. Paradoxical embolism occurs when venous blood crosses the PFO into the arterial system, bypassing the pulmonary circulation. This allows for the direct passage of microemboli into cerebral blood vessels, increasing the risk of cryptogenic stroke. This review investigates the current diagnostic procedures used to detect and grade a PFO, including transthoracic echocardiography (TTE), transoesophageal echocardiography (TOE) and transcranial Doppler (TCD). Only a few studies have directly compared the use of TTE with TCD for PFO detection but several have compared TTE and TCD independently against the clinical gold standard TOE. Known pitfalls of TTE and TCD are also discussed, including the difficulty of differentiating between intracardiac shunts and intrapulmonary shunts. This review also discusses methods to optimise imaging, such as performing an adequate Valsalva manoeuvre, the role of abdominal compression and the choice of the injection site for the contrast agent and how these may increase the diagnostic success of detecting a right-to-left shunt when prompted by a clinician.