Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Cardiovasc Imaging ; 28(8): 1895-904, 2012 Dec.
Article in English | MEDLINE | ID: mdl-22302648

ABSTRACT

A novel method to assess left ventricular (LV) mechanical dyssynchrony using three-dimensional echocardiography (3DE) and semi-automated border detection was investigated, which might be superior in prediction of response to cardiac resynchronisation therapy (CRT) compared to traditional measures that rely solely on segmental time-to-contraction. Twenty-eight heart failure patients underwent real-time 3DE before CRT and at 6­12 months follow-up. Analysis of 3DE was performed using TomTec Research-Arena software featuring semi-automated endocardial border detection. The following echocardiographic parameters were calculated in a 16-segment model: areas under segmental time-volume-curves (STV); delay between contraction of the earliest and latest segment (L-E); and standard deviation of segmental time-to-contraction (SDI). Response to CRT was defined as ≥10% decrease in LV end-systolic volume at follow-up. Baseline Pre-STV had a higher sensitivity than SDI for prediction of response (94 vs 67%, respectively), with equal specificity (78%) and a higher area under receiver operator characteristic curve. In contrast, L-E had a sensitivity of 83% and a specificity of 56%. Using 3DE, methods that combine segmental time-to-contraction with segmental contractility might improve LV dyssynchrony assessment compared to traditional methods based on segmental time-to-contraction alone. Pre-STV might be a better predictor of response to CRT than SDI.


Subject(s)
Cardiac Resynchronization Therapy , Echocardiography, Three-Dimensional , Heart Failure/diagnostic imaging , Heart Failure/therapy , Image Interpretation, Computer-Assisted , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Left/therapy , Ventricular Function, Left , Aged , Automation , Female , Heart Failure/physiopathology , Humans , Male , Middle Aged , Myocardial Contraction , Predictive Value of Tests , Sensitivity and Specificity , Software , Stroke Volume , Time Factors , Treatment Outcome , Ventricular Dysfunction, Left/physiopathology
2.
Neth Heart J ; 19(10): 423-31, 2011 Oct.
Article in English | MEDLINE | ID: mdl-21584798

ABSTRACT

One of the earliest applications of clinical echocardiography is evaluation of left ventricular (LV) function and size. Accurate, reproducible and quantitative evaluation of LV function and size is vital for diagnosis, treatment and prediction of prognosis of heart disease. Early three-dimensional (3D) echocardiographic techniques showed better reproducibility than two-dimensional (2D) echocardiography and narrower limits of agreement for assessment of LV function and size in comparison to reference methods, mostly cardiac magnetic resonance (CMR) imaging, but acquisition methods were cumbersome and a lack of user-friendly analysis software initially precluded widespread use. Through the advent of matrix transducers enabling real-time three-dimensional echocardiography (3DE) and improvements in analysis software featuring semi-automated volumetric analysis, 3D echocardiography evolved into a simple and fast imaging modality for everyday clinical use. 3DE provides the possibility to evaluate the entire LV in three spatial dimensions during the complete cardiac cycle, offering a more accurate and complete quantitative evaluation the LV. Improved efficiency in acquisition and analysis may provide clinicians with important diagnostic information within minutes. The current article reviews the methodology and application of 3DE for quantitative evaluation of the LV, provides the scientific evidence for its current clinical use, and discusses its current limitations and potential future directions.

3.
Neth Heart J ; 16(2): 47-52, 2008 Feb.
Article in English | MEDLINE | ID: mdl-18335021

ABSTRACT

BACKGROUND: In three-dimensional echocardiography (3DE), individual endocardial trabeculae are not clearly visible necessitating left ventricular (LV) volumes to be measured by tracing the innermost endocardial contour. Ultrasound contrast agents aim to improve endocardial definition, but may delineate the outermost endocardial contour by filling up intertrabecular space. Although measurement reproducibility may benefit, there may be a significant influence on absolute LV volume measurements. METHODS: Twenty patients with a recent myocardial infarction and good ultrasound image quality underwent 3DE using the TomTec Freehand method before and during continuous intravenous contrast infusion. LV volumes were measured offline using TomTec Echo-Scan software. RESULTS: The use of contrast enhancement increased end-diastolic (110+/-35 vs. 144+/-53 ml; p<0.01) and end-systolic volume measurements (68+/-31 vs. 87+/-45 ml; p<0.01) significantly compared with non-contrast; the ejection fraction remained unchanged (40+/-13 vs. 41+/-14%, p=NS). Measurement reproducibility did not improve significantly, however. CONCLUSION: Volumes measured by 3DE are significantly larger when ultrasound contrast is used. Possibly, intertrabecular space comprises a substantial part of the LV cavity. In the presence of an adequate apical acoustic window, ultrasound contrast does not improve LV volume measurement reproducibility. (Neth Heart J 2008;16:47-52.).

SELECTION OF CITATIONS
SEARCH DETAIL
...