Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 27
Filter
1.
EuroIntervention ; 19(9): 766-771, 2023 Nov 17.
Article in English | MEDLINE | ID: mdl-37605804

ABSTRACT

About one-third of patients undergoing transcatheter aortic valve implantation (TAVI) use oral anticoagulants (OAC), mainly due to atrial fibrillation. General guidelines advise interrupting OAC in patients with a high risk of bleeding undergoing interventions. However, preliminary observational data suggest that the continuation of OAC during TAVI is safe and may reduce the risk of periprocedural thromboembolic events. The Periprocedural Continuation Versus Interruption of Oral Anticoagulant Drugs During Transcatheter Aortic Valve Implantation (POPular PAUSE TAVI) is a multicentre, randomised clinical trial with open-label treatment and blinded endpoint assessment. Patients are randomised 1:1 to periprocedural continuation versus interruption of OAC and are stratified for vitamin K antagonist or direct oral anticoagulant use. The primary endpoint is a composite of cardiovascular mortality, all stroke, myocardial infarction, major vascular complications and type 2-4 bleeding within 30 days after TAVI, according to the Valve Academic Research Consortium-3 criteria. Secondary endpoints include separate individual and composite outcomes, quality of life and cost-effectiveness. Since continuation of OAC is associated with the ancillary benefit that it simplifies periprocedural management, the primary outcome is first analysed for non-inferiority; if non-inferiority is proven, superiority will be tested. Recruitment started in November 2020, and the trial will continue until a total of 858 patients have been included and followed for 90 days. In summary, POPular PAUSE TAVI is the first randomised clinical trial to assess the safety and efficacy of periprocedural continuation versus interruption of OAC in patients undergoing TAVI.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Quality of Life , Anticoagulants/therapeutic use , Hemorrhage , Treatment Outcome , Aortic Valve/surgery , Risk Factors
2.
JACC Cardiovasc Interv ; 16(16): 2004-2017, 2023 08 28.
Article in English | MEDLINE | ID: mdl-37480891

ABSTRACT

OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.


Subject(s)
Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Incidence , Bundle-Branch Block , Prognosis , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
3.
JACC cardiovasc. interv ; (23): (23)00846-4, jul.2023. ilus
Article in English | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1444382

ABSTRACT

OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.


Subject(s)
Pacemaker, Artificial
4.
Circ Cardiovasc Interv ; 16(1): e012538, 2023 01.
Article in English | MEDLINE | ID: mdl-36649387

ABSTRACT

BACKGROUND: In recent years, transcatheter aortic valve replacement (TAVR) techniques and technology have continuously improved. Data regarding the impact of these advancements on outcomes in large real-world settings are still limited. The aim of this study was to investigate temporal trends and assess contemporary outcomes after TAVR with Evolut PRO/PRO+ supra-annular self-expanding valves. METHODS: This study included patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries who underwent transfemoral TAVR with Evolut PRO/PRO+. Procedural dates (August 2017 through November 2021) were stratified in quartiles (Q) and used to investigate temporal trends in TAVR outcomes. Predischarge, 30-day Valve Academic Research Consortium-3 defined, and 1-year outcomes were evaluated. RESULTS: In total, 1616 patients from 28 centers were included. Over time, patients had lower Society of Thoracic Surgeon-Predicted Risk of Mortality score (Q1-4, 4.1% [2.8-6.3%], 3.7% [2.6-5.3%], 3.3% [2.4-4.9%], 2.9% [2.2-4.3%]; P<0.001) and more moderate or heavy valve calcification (Q1-4, 80%, 80%, 82%, 88%; P=0.038). Overall Valve Academic Research Consortium-3 technical success was 94.1%, with 30-day and 1-year all-cause mortality of 2.4% and 10%, respectively. Throughout the study period, procedures were associated with higher rates of 30-day device success (Q1-4, 81.2%, 82.2%, 82.0%, 88.0%; Cochran-Armitage P=0.023) and early safety (Q1-4, 66.8%, 67.5%, 74.0%, 77.6%; Cochran-Armitage P<0.001), with fewer permanent pacemaker implantations (Q1-4: 15.3%, 20.0%, 12.1%, 11.6%; Cochran-Armitage P=0.023) and residual mild or greater paravalvular leaks (Q1-4, 50.4%, 42.1%, 36.5%, 35.8%; Cochran-Armitage P<0.001). CONCLUSIONS: TAVR with Evolut PRO/PRO+ self-expanding valve is safe and effective. Despite the treatment of heavier calcified anatomies, procedural outcomes are improving over time with less need for pacemaker implantation and less significant paravalvular leaks.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Time Factors , Treatment Outcome , Registries , Prosthesis Design , Risk Factors
5.
N Engl J Med ; 383(15): 1447-1457, 2020 10 08.
Article in English | MEDLINE | ID: mdl-32865376

ABSTRACT

BACKGROUND: The effect of single as compared with dual antiplatelet treatment on bleeding and thromboembolic events after transcatheter aortic-valve implantation (TAVI) in patients who do not have an indication for long-term anticoagulation has not been well studied. METHODS: In a randomized, controlled trial, we assigned a subgroup of patients who were undergoing TAVI and did not have an indication for long-term anticoagulation, in a 1:1 ratio, to receive aspirin alone or aspirin plus clopidogrel for 3 months. The two primary outcomes were all bleeding (including minor, major, and life-threatening or disabling bleeding) and non-procedure-related bleeding over a period of 12 months. Most bleeding at the TAVI puncture site was counted as non-procedure-related. The two secondary outcomes were a composite of death from cardiovascular causes, non-procedure-related bleeding, stroke, or myocardial infarction (secondary composite 1) and a composite of death from cardiovascular causes, ischemic stroke, or myocardial infarction (secondary composite 2) at 1 year, with both outcomes tested sequentially for noninferiority (noninferiority margin, 7.5 percentage points) and superiority. RESULTS: A total of 331 patients were assigned to receive aspirin alone and 334 were assigned to receive aspirin plus clopidogrel. A bleeding event occurred in 50 patients (15.1%) receiving aspirin alone and in 89 (26.6%) receiving aspirin plus clopidogrel (risk ratio, 0.57; 95% confidence interval [CI], 0.42 to 0.77; P = 0.001). Non-procedure-related bleeding occurred in 50 patients (15.1%) and 83 patients (24.9%), respectively (risk ratio, 0.61; 95% CI, 0.44 to 0.83; P = 0.005). A secondary composite 1 event occurred in 76 patients (23.0%) receiving aspirin alone and in 104 (31.1%) receiving aspirin plus clopidogrel (difference, -8.2 percentage points; 95% CI for noninferiority, -14.9 to -1.5; P<0.001; risk ratio, 0.74; 95% CI for superiority, 0.57 to 0.95; P = 0.04). A secondary composite 2 event occurred in 32 patients (9.7%) and 33 patients (9.9%), respectively (difference, -0.2 percentage points; 95% CI for noninferiority, -4.7 to 4.3; P = 0.004; risk ratio, 0.98; 95% CI for superiority, 0.62 to 1.55; P = 0.93). A total of 44 patients (13.3%) and 32 (9.6%), respectively, received oral anticoagulation during the trial. CONCLUSIONS: Among patients undergoing TAVI who did not have an indication for oral anticoagulation, the incidence of bleeding and the composite of bleeding or thromboembolic events at 1 year were significantly less frequent with aspirin than with aspirin plus clopidogrel administered for 3 months. (Funded by the Netherlands Organization for Health Research and Development; POPular TAVI EU Clinical Trials Register number, 2013-003125-28; ClinicalTrials.gov number, NCT02247128.).


Subject(s)
Aspirin/therapeutic use , Clopidogrel/therapeutic use , Hemorrhage/chemically induced , Platelet Aggregation Inhibitors/therapeutic use , Thrombosis/prevention & control , Transcatheter Aortic Valve Replacement , Administration, Oral , Aged , Aged, 80 and over , Aspirin/adverse effects , Cardiovascular Diseases/epidemiology , Cardiovascular Diseases/mortality , Clopidogrel/adverse effects , Drug Therapy, Combination , Female , Hemorrhage/epidemiology , Humans , Incidence , Male , Platelet Aggregation Inhibitors/adverse effects , Postoperative Period , Thrombosis/epidemiology
6.
Am. j. cardiol ; 125(9): 1369-1377, May., 2020. graf.
Article in English | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1099637

ABSTRACT

Safety and feasibility of transfemoral Acurate neo implantation without systematic predilatation are not fully investigated. Our aim was to evaluate the use and impact of pre-implantation balloon aortic valvuloplasty (pre-BAV) before transcatheter aortic valve implantation (TAVI) with Acurate neo. The NEOPRO Registry retrospectively included 1,263 patients who underwent transfemoral TAVI with Acurate neo at 18 centers between January 2012 and March 2018. Information on preBAV was available for 1,262 patients (99.9%). Primary endpoints were pre-discharge moderate-tosevere paravalvular aortic regurgitation (PAR II+), 30-day new permanent pacemaker implantation (PPI), and 30-day all-cause mortality or stroke. A total of 1,262 patients who underwent TAVI with (n=1,051) or without predilatation (n=211) were included. A reduction in the pre-BAV rate was observed during the study period (from 95.7% in the first date quintile to 78.4% in the last date quintile). Patients who underwent pre-BAV had higher degrees of aortic valve (AV) and left ventricular outflow tract (LVOT) calcification. Primary endpoints were similar between pre-BAV and no pre-BAV groups (PAR II+ 5.5% vs. 3.4%, p=0.214; 30-day PPI 9.0% vs. 8.0%, p=0.660; 30-day death or stroke 4.9% vs. 4.4%, p=0.743). The need for postdilatation and other procedural outcomes were comparable between groups. Predilatation did not have a significant impact on primary endpoints across AV and LVOT calcification subgroups (subgroup analyses) and was not independently associated with primary endpoints (multivariate analyses). In conclusion, transfemoral Acurate neo implantation without predilatation appears to be feasible and safe, especially in patients with milder degrees of AV and LVOT calcification. (AU)


Subject(s)
Transcatheter Aortic Valve Replacement , Aortic Valve
7.
N Engl J Med ; 382(18): 1696-1707, 2020 04 30.
Article in English | MEDLINE | ID: mdl-32223116

ABSTRACT

BACKGROUND: The roles of anticoagulation alone or with an antiplatelet agent after transcatheter aortic-valve implantation (TAVI) have not been well studied. METHODS: We performed a randomized trial of clopidogrel in patients undergoing TAVI who were receiving oral anticoagulation for appropriate indications. Patients were assigned before TAVI in a 1:1 ratio not to receive clopidogrel or to receive clopidogrel for 3 months. The two primary outcomes were all bleeding and non-procedure-related bleeding over a period of 12 months. Procedure-related bleeding was defined as Bleeding Academic Research Consortium type 4 severe bleeding, and therefore most bleeding at the puncture site was counted as non-procedure-related. The two secondary outcomes were a composite of death from cardiovascular causes, non-procedure-related bleeding, stroke, or myocardial infarction at 12 months (secondary composite 1) and a composite of death from cardiovascular causes, ischemic stroke, or myocardial infarction (secondary composite 2), both tested for noninferiority (noninferiority margin, 7.5 percentage points) and superiority. RESULTS: Bleeding occurred in 34 of the 157 patients (21.7%) receiving oral anticoagulation alone and in 54 of the 156 (34.6%) receiving oral anticoagulation plus clopidogrel (risk ratio, 0.63; 95% confidence interval [CI], 0.43 to 0.90; P = 0.01); most bleeding events were at the TAVI access site. Non-procedure-related bleeding occurred in 34 patients (21.7%) and in 53 (34.0%), respectively (risk ratio, 0.64; 95% CI, 0.44 to 0.92; P = 0.02). Most bleeding occurred in the first month and was minor. A secondary composite 1 event occurred in 49 patients (31.2%) receiving oral anticoagulation alone and in 71 (45.5%) receiving oral anticoagulation plus clopidogrel (difference, -14.3 percentage points; 95% CI for noninferiority, -25.0 to -3.6; risk ratio, 0.69; 95% CI for superiority, 0.51 to 0.92). A secondary composite 2 event occurred in 21 patients (13.4%) and in 27 (17.3%), respectively (difference, -3.9 percentage points; 95% CI for noninferiority, -11.9 to 4.0; risk ratio, 0.77; 95% CI for superiority, 0.46 to 1.31). CONCLUSIONS: In patients undergoing TAVI who were receiving oral anticoagulation, the incidence of serious bleeding over a period of 1 month or 1 year was lower with oral anticoagulation alone than with oral anticoagulation plus clopidogrel. (Funded by the Netherlands Organization for Health Research and Development; POPular TAVI EU Clinical Trials Register number, 2013-003125-28; ClinicalTrials.gov number, NCT02247128.).


Subject(s)
Anticoagulants/therapeutic use , Clopidogrel/therapeutic use , Hemorrhage/chemically induced , Platelet Aggregation Inhibitors/therapeutic use , Transcatheter Aortic Valve Replacement , Administration, Oral , Aged , Aged, 80 and over , Anticoagulants/adverse effects , Cardiovascular Diseases/epidemiology , Cardiovascular Diseases/mortality , Clopidogrel/adverse effects , Drug Therapy, Combination , Hemorrhage/epidemiology , Humans , Incidence , Kaplan-Meier Estimate , Male , Platelet Aggregation Inhibitors/adverse effects , Transcatheter Aortic Valve Replacement/adverse effects
8.
Am J Cardiol ; 125(9): 1369-1377, 2020 05 01.
Article in English | MEDLINE | ID: mdl-32098656

ABSTRACT

Safety and feasibility of transfemoral Acurate neo implantation without systematic predilatation are not fully investigated. Our aim was to evaluate the use and impact of pre-implantation balloon aortic valvuloplasty (pre-BAV) before transcatheter aortic valve implantation (TAVI) with Acurate neo. The NEOPRO Registry retrospectively included 1,263 patients who underwent transfemoral TAVI with Acurate neo at 18 centers between January 2012 and March 2018. Information on pre-BAV was available for 1,262 patients (99.9%). Primary end points were pre-discharge moderate-to-severe paravalvular aortic regurgitation (PAR II+), 30-day new permanent pacemaker implantation, and 30-day all-cause mortality or stroke. A total of 1,262 patients who underwent TAVI with (n = 1,051) or without predilatation (n = 211) were included. A reduction in the pre-BAV rate was observed during the study period (from 95.7% in the first date quintile to 78.4% in the last date quintile). Patients who underwent pre-BAV had higher degrees of aortic valve (AV) and left ventricular outflow tract (LVOT) calcification. Primary endpoints were similar between pre-BAV and no pre-BAV groups (PAR II+ 5.5% vs 3.4%, p = 0.214; 30-day permanent pacemaker implantation 9.0% vs 8.0%, p = 0.660; 30-day death or stroke 4.9% vs 4.4%, p = 0.743). The need for postdilatation and other procedural outcomes were comparable between groups. Predilatation did not have a significant impact on primary endpoints across AV and LVOT calcification subgroups (subgroup analyses) and was not independently associated with primary endpoints (multivariate analyses). In conclusion, transfemoral Acurate neo implantation without predilatation appears to be feasible and safe, especially in patients with milder degrees of AV and LVOT calcification.


Subject(s)
Aortic Valve Stenosis/surgery , Balloon Valvuloplasty/instrumentation , Dilatation/instrumentation , Transcatheter Aortic Valve Replacement/methods , Aged , Aged, 80 and over , Equipment Design , Female , Humans , Male , Preoperative Period , Registries , Retrospective Studies
9.
Curr Cardiol Rep ; 21(5): 37, 2019 03 28.
Article in English | MEDLINE | ID: mdl-30924027

ABSTRACT

PURPOSE OF REVIEW: This review aims to provide an updated overview and a clinical perspective on novel transcatheter tricuspid valve interventions (TTVI), highlighting potential challenges and future directions. RECENT FINDINGS: Severe tricuspid regurgitation (TR) is a predictor of mortality. However, a sizeable number of patients remain untreated until the end-stage when cardiac surgery presents a prohibitive risk. The emergent need in finding a treatment for patients with TR, deemed for surgery options, has encouraged the development of TTVI. These procedures mimic classical surgery techniques and are mainly divided in four categories: annuloplasty and coaptation devices, edge-to-edge techniques and transcatheter tricuspid valve replacement. Early studies showed promising results, but long-term follow-up data are not available. For patients with severe TR and high surgical risk, several percutaneous options are available. However, these therapies are in a growing phase and bigger studies and long term follow-up are needed to prove their efficacy.


Subject(s)
Cardiac Catheterization/methods , Heart Valve Prosthesis Implantation/methods , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve/surgery , Humans , Treatment Outcome
10.
JACC Cardiovasc Interv ; 12(5): 433-443, 2019 03 11.
Article in English | MEDLINE | ID: mdl-30846081

ABSTRACT

OBJECTIVES: The aim of this study was to compare transcatheter aortic valve replacement (TAVR) with the Acurate neo (NEO) and Evolut PRO (PRO) devices. BACKGROUND: The NEO and PRO bioprostheses are 2 next-generation self-expanding devices developed for TAVR. METHODS: The NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) registry retrospectively included patients who underwent transfemoral TAVR with either NEO or PRO valves at 24 centers between January 2012 and March 2018. One-to-one propensity score matching resulted in 251 pairs. Pre-discharge and 30-day Valve Academic Research Consortium (VARC)-2 defined outcomes were evaluated. Binary logistic regression was performed to adjust the treatment effect for propensity score quintiles. RESULTS: A total of 1,551 patients (n = 1,263 NEO; n = 288 PRO) were included. The mean age was 82 years, and the mean Society of Thoracic Surgeons score was 5.1%. After propensity score matching (n = 502), VARC-2 device success (90.6% vs. 91.6%; p = 0.751) and pre-discharge moderate to severe (II+) paravalvular aortic regurgitation (7.3% vs. 5.7%; p = 0.584) were comparable between the NEO and PRO groups. Furthermore, there were no significant differences in any 30-day clinical outcome between matched NEO and PRO pairs, including all-cause mortality (3.2% vs. 1.2%; p = 0.221), stroke (2.4% vs. 2.8%; p = 1.000), new permanent pacemaker implantation (11.0% vs. 12.8%; p = 0.565), and VARC-2 early safety endpoint (10.6% vs. 10.4%; p = 1.000). Logistic regression on the unmatched cohort confirmed a similar risk of VARC-2 device success, paravalvular aortic regurgitation II+, and 30-day clinical outcomes after NEO and PRO implantation. CONCLUSIONS: In this multicenter registry, transfemoral TAVR with the NEO and PRO bioprostheses was associated with high device success, acceptable rates of paravalvular aortic regurgitation II+, and good 30-day clinical outcomes. After adjusting for potential confounders, short-term outcomes were similar between the devices.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Bioprosthesis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Female , Humans , Male , Postoperative Complications/etiology , Postoperative Complications/mortality , Propensity Score , Prosthesis Design , Registries , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
11.
Int J Cardiol ; 283: 84-87, 2019 05 15.
Article in English | MEDLINE | ID: mdl-30449693

ABSTRACT

Percutaneous recanalization of coronary chronic total occlusions (CTOs) traditionally relies on the use of dual access and large bore catheters, with trans-femoral approach adoption in most of the cases. Aim of this manuscript is to describe an alternative algorithm, that we called "Minimalistic Hybrid Algorithm", in order to minimize the use of double access, large bore catheters, and femoral approach thus reducing patient's discomfort and possibly procedural complications. This algorithm can be interpreted as an evolution of the classic "Hybrid Algorithm" and requires the operator to be confident with all techniques known in this conventional algorithm. Indeed, all possible techniques and approaches of the conventional hybrid approach to treat CTOs are included in a novel diagram for procedural strategy, which offers an alternative sequence of steps to limit, whenever possible, the invasiveness of the procedure. After dividing the cases in "simple" or "complex" CTO lesions according to the available complexity scores and to the "feeling", knowledge and expertise of the operator, a systematic description of the procedural steps is provided. This includes antegrade and retrograde approaches, as well as sub-intimal and intra-luminal techniques, in order to maintain the simpler single-catheter transradial strategies in the first line for the simple CTO, and the adoption of more complex, double access and transfemoral ones in the further steps. The minimalistic hybrid algorithm herein described is a possible alternative sequence of steps in the setting of CTO recanalization, with the potential of limiting the use of double access, large bore catheters, and femoral approach.


Subject(s)
Algorithms , Coronary Occlusion/surgery , Minimally Invasive Surgical Procedures/methods , Percutaneous Coronary Intervention/methods , Chronic Disease , Coronary Angiography , Coronary Occlusion/diagnosis , Femoral Artery , Humans , Radial Artery
12.
Catheter Cardiovasc Interv ; 93(6): 1097-1105, 2019 05 01.
Article in English | MEDLINE | ID: mdl-30461187

ABSTRACT

OBJECTIVE: The aim of this study was to describe the early use of dedicated patient specific computer modeling in patients with bicuspid aortic valve (BAV) undergoing transcatheter aortic valve implantation (TAVI), in predicting procedure feasibility and patient related outcome. BACKGROUND: Dedicated patient specific computer modeling, used for optimizing TAVI procedures, is currently validated for the prediction of contact pressure, valve morphology and paravalvular leakage (PVL). The simulation of TAVI procedures is increasingly used in patients with tricuspid aortic valve stenosis. Currently, BAV disease is considered as a relative contra-indication for TAVI due to its specific anatomical characteristics. METHODS: This single center study consisted of seven patients with BAV undergoing TAVI. A patient specific computer simulation was performed based on multislice computer tomography images. The model advised the best fitting prosthetic valve size or sizes and simulated this valve on different implantation depths with the corresponding presence and severity of PVL and prosthetic valve morphology. The simulation results were compared with the procedural outcomes using transesophageal echocardiography (TEE) and fluoroscopy. RESULTS: The patient specific computer modeling predicted accurately the outcome (PVL and valve morphology) of TAVI in all cases. In one case, the TAVI procedure was unsuccessful and retrospectively not suitable for TAVI, which was correctly predicted by the model. CONCLUSION: The patient specific computer modeling adequately predicts feasibility and outcome of TAVI in patients with BAV disease and may extend the applicability of TAVI. Moreover, it improves decision-making and therefore individual procedural outcomes in this difficult patient population.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/abnormalities , Heart Valve Diseases/complications , Models, Cardiovascular , Patient-Specific Modeling , Surgery, Computer-Assisted , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/etiology , Aortic Valve Stenosis/physiopathology , Bicuspid Aortic Valve Disease , Clinical Decision-Making , Decision Support Techniques , Feasibility Studies , Female , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/physiopathology , Heart Valve Prosthesis , Humans , Male , Multidetector Computed Tomography , Patient Selection , Prosthesis Design , Retrospective Studies , Surgery, Computer-Assisted/adverse effects , Surgery, Computer-Assisted/instrumentation , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Treatment Outcome
14.
Am J Cardiol ; 121(10): 1239-1245, 2018 05 15.
Article in English | MEDLINE | ID: mdl-29525062

ABSTRACT

Transcatheter aortic valve implantation (TAVI) is associated with acute kidney injury (AKI), but can also improve the kidney function (IKF). We assessed the effects of kidney function changes in relation to baseline kidney function on 2-year clinical outcomes after TAVI. In total, 639 consecutive patients with aortic stenosis who underwent TAVI were stratified into 3 groups according to the ratio of serum creatinine post- to pre-TAVI: IKF (≤0.80; n = 95 [15%]), stable kidney function (0.80 to 1.5; n = 477 [75%]), and AKI (≥1.5; n = 67 [10%]). Different AKI risk scores were compared using receiving-operator characteristics. Median follow-up was 24 (8 to 44) months. At 3 months, the increase in estimated glomerular filtration rate in the IKF group remained, and the decreased estimated glomerular filtration rate in the AKI group recovered. Compared with a stable kidney function, AKI showed a higher 2-year mortality rate (adjusted hazard ratio [HR] 3.69, 95% confidence interval [CI] 2.43 to 5.62) and IKF a lower mortality rate (adjusted hazard ratio 0.53, 95% CI 0.30 to 0.93). AKI also predicted major and life-threatening bleeding (adjusted odds ratio 2.94, 95% CI 1.27 to 6.78). Independent predictors of AKI were chronic kidney disease and pulmonary hypertension. Independent predictors of IKF were female gender, a preserved kidney function, absence of atrial fibrillation, and hemoglobin level. Established AKI risk scores performed moderately and did not differentiate between AKI and IKF. In conclusion, AKI is transient and is independently associated with a higher mortality rate, whereas IKF is sustained and is associated with a lower mortality rate. These effects are independent of baseline kidney function. Further studies are warranted to investigate the role of IKF and generate a dedicated prediction model.


Subject(s)
Aortic Valve Stenosis/surgery , Creatinine/metabolism , Glomerular Filtration Rate , Renal Insufficiency, Chronic/metabolism , Transcatheter Aortic Valve Replacement , Acute Kidney Injury/epidemiology , Aged , Aged, 80 and over , Aortic Valve Stenosis/epidemiology , Comorbidity , Female , Hemorrhage/epidemiology , Humans , Hypertension, Pulmonary/epidemiology , Linear Models , Logistic Models , Male , Mortality , Odds Ratio , Postoperative Complications/epidemiology , Prognosis , Proportional Hazards Models , Renal Insufficiency, Chronic/epidemiology , Retrospective Studies , Sex Factors , Treatment Outcome
15.
Catheter Cardiovasc Interv ; 92(5): E299-E307, 2018 11 01.
Article in English | MEDLINE | ID: mdl-29411523

ABSTRACT

BACKGROUND: Coronary chronic total occlusions (CTO) usually coexist with diffusely diseased coronary segments proximal and/or distal to the CTO segment. During percutaneous treatment of CTO, multiple overlapping stents are often needed to treat these long lesions. OBJECTIVES: Aim of this study is to report the first use of long, tapered coronary sirolimus-eluting stents (SES) in this setting. METHODS AND RESULTS: This is a retrospective analysis of 100 consecutive patients undergoing CTO recanalization following the hybrid algorithm. Procedural success rate was 89% (11 failures). Among the successful cases, "conventional" drug-eluting stents(DES) were used in 40(44.9%) patients, while in 49(55%) patients long-tapered SES were attempted with a success rate of 98% (1 cross-over to regular stents). Total stent length in the long-tapered DES group was higher compared to the "conventional" stenting group (76 ± 28 mm vs 46 ± 22 mm, P < .001), with a similar total number of stent (1.6 ± 0.8 vs 1.9 ± 0.8). At quantitative coronary analysis, proximal and distal segment involvement was more extended in patients undergoing long-tapered stenting, with longer overall lesion length. No differences in periprocedural complications and clinical outcomes at a mean follow-up of 303 ± 179 days were observed. CONCLUSIONS: The use of long tapered coronary DES is technically feasible and safe for the percutaneous treatment of CTOs, especially for patients presenting with long lesions.


Subject(s)
Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon, Coronary/instrumentation , Cardiovascular Agents/administration & dosage , Coronary Occlusion/therapy , Drug-Eluting Stents , Sirolimus/administration & dosage , Aged , Cardiovascular Agents/adverse effects , Chronic Disease , Coronary Occlusion/diagnostic imaging , Coronary Occlusion/physiopathology , Female , Humans , Male , Middle Aged , Prosthesis Design , Retrospective Studies , Sirolimus/adverse effects , Time Factors , Treatment Outcome , Vascular Patency
16.
Am J Cardiol ; 120(11): 2035-2040, 2017 Dec 01.
Article in English | MEDLINE | ID: mdl-29033048

ABSTRACT

Percutaneous mitral valve repair with the MitraClip is an established treatment for patients with mitral regurgitation (MR) who are inoperable or at high risk for surgery. Atrial Fibrillation (AF) frequently coincides with MR, but only scarce data of the influence of AF on outcome after MitraClip is available. The aim of the current study was to compare the clinical outcome after MitraClip treatment in patients with versus without atrial fibrillation. Between January 2009 and January 2016, all consecutive patients treated with a MitraClip in 5 Dutch centers were included. Outcome measures were survival, symptoms, MR grade, and stroke incidence. In total, 618 patients were treated with a MitraClip. Patients with AF were older, had higher N-terminal B-type natriuretic peptide levels, more tricuspid regurgitation, less often coronary artery disease and a better left ventricular function. Survival of patients treated with the MitraClip was similar for patients with AF (82%) and without AF (non-AF; 85%) after 1 year (p = 0.30), but significantly different after 5-year follow-up (AF 34%; non-AF 47%; p = 0.006). After 1 month, 64% of the patients with AF were in New York Heart Association class I or II, in contrast to 77% of the patients without AF (p = 0.001). The stroke incidence appeared not to be significantly different (AF 1.8%; non-AF 1.0%; p = 0.40). In conclusion, patients with AF had similar 1-year survival, MR reduction, and stroke incidence compared with non-AF patients. However, MitraClip patients with AF had reduced long-term survival and remained more symptomatic compared with those without AF.


Subject(s)
Atrial Fibrillation/complications , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis , Mitral Valve Insufficiency/surgery , Mitral Valve/surgery , Postoperative Complications/epidemiology , Ventricular Function, Left/physiology , Aged , Aged, 80 and over , Atrial Fibrillation/mortality , Atrial Fibrillation/physiopathology , Echocardiography, Transesophageal , Electrocardiography , Female , Humans , Incidence , Kaplan-Meier Estimate , Male , Middle Aged , Mitral Valve/diagnostic imaging , Mitral Valve Insufficiency/complications , Mitral Valve Insufficiency/mortality , Netherlands/epidemiology , Prosthesis Design , Retrospective Studies , Severity of Illness Index , Treatment Outcome
19.
Cardiovasc Diagn Ther ; 6(2): 160-5, 2016 Apr.
Article in English | MEDLINE | ID: mdl-27054105

ABSTRACT

Percutaneous edge-to-edge mitral valve (MV) repair is a relatively new treatment option for mitral regurgitation (MR). After the feasibility and safety having been proved in low-surgical-risk patients, the use of this procedure has shifted more to the treatment of high-risk patients. With the absence of randomized controlled trials (RCT) for this particular subgroup, observational studies try to add evidence to the safety aspect of this procedure. These also provide short- and mid-term mortality figures. Several mortality predictors have been identified, which may help the optimal selection of patients who will benefit most from this technique. In this article we provide an overview of the literature about mortality and its predictors in patients treated with the percutaneous edge-to-edge device.

20.
Catheter Cardiovasc Interv ; 87(3): 467-75, 2016 Feb 15.
Article in English | MEDLINE | ID: mdl-26268819

ABSTRACT

OBJECTIVES: To evaluate long-term survival in high surgical risk patients undergoing percutaneous mitral valve repair (MVR) using the MitraClip(®) system and to identify preprocedural predictors of long-term mortality. BACKGROUND: Data for long-term survival and preprocedural predictors of mortality after percutaneous MVR in high surgical risk patients are sporadic. METHODS: From January 2009 to April 2013, 136 consecutive high surgical risk patients, with symptomatic moderate-to-severe or severe mitral regurgitation (MR), underwent percutaneous MVR using the MitraClip system. Cardiac and overall survival was determined at one and 2 years postprocedure. Univariate and multivariate analysis was performed to identify preprocedural predictors of long-term mortality. RESULTS: One year postprocedure, cardiac and overall survival was 86.7% and 84.6%, respectively and at 2 years cardiac and overall survival was 77.7% and 74.8%, respectively. In univariate analysis advanced age, lower body mass index, impaired renal function, elevated levels of log-N-terminal-pro-brain-natriuretic-peptide (log-NTproBNP), poor performance in functional tests (New York Heart Association (NYHA) class) and high logistic Euroscore (LES) and Society of Thoracic Surgeons (STS) score were identified as preprocedural predictors of long-term cardiac mortality. In multivariate analysis preoperative NYHA class III and IV, elevated levels of log-NTproBNP and advanced age predicted long-term cardiac mortality. CONCLUSIONS: Percutaneous MVR using the MitraClip system has favorable long-term survival rates in high surgical risk patients. Preprocedural NYHA functional class III and IV, elevated log-NTproBNP levels and advanced age predict higher long-term cardiac mortality and should be considered during patient selection.


Subject(s)
Cardiac Catheterization/mortality , Heart Valve Prosthesis Implantation/mortality , Mitral Valve Insufficiency/therapy , Mitral Valve , Aged , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Female , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Mitral Valve/physiopathology , Mitral Valve Insufficiency/diagnosis , Mitral Valve Insufficiency/mortality , Mitral Valve Insufficiency/physiopathology , Multivariate Analysis , Proportional Hazards Models , Prosthesis Design , Risk Assessment , Risk Factors , Severity of Illness Index , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...