Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Endoscopy ; 54(5): 509-514, 2022 05.
Article in English | MEDLINE | ID: mdl-34521120

ABSTRACT

BACKGROUND : Suboptimal lifting increases complexity of endoscopic mucosal resection (EMR) for benign colorectal polyps. Cap-assisted EMR (EMR-C) may allow fibrotic polyp tissue to be captured in the snare. This study evaluated the efficacy and safety of EMR-C for benign nonlifting colorectal polyps. METHODS : This was a multicenter study, which prospectively registered all EMR-C procedures (2016-2018) for presumed benign nonlifting colorectal polyps. RESULTS : 70 nonlifting polyps with a median size of 25 mm (interquartile range [IQR] 15-40) were treated with EMR-C. Complete polyp removal was achieved in 68 (97.1 %), including 47 (67.1 %) with EMR-C alone. Overall, 66 polyps showed benign histology, and endoscopic follow-up after a median of 6 months (IQR 6-10) showed recurrence in 19.7 %. First (n = 10) and second (n = 2) benign recurrences were all treated endoscopically. Deep mural injury type III-V occurred in 7.4 % and was treated successfully with clips. CONCLUSION : EMR-C may be an alternative therapeutic option for removal of benign nonlifting polyp tissue. Although recurrence still occurs, repeat endoscopic therapy usually leads to complete polyp clearance.


Subject(s)
Colonic Polyps , Endoscopic Mucosal Resection , Colonic Polyps/pathology , Colonic Polyps/surgery , Colonoscopy/adverse effects , Colonoscopy/methods , Endoscopic Mucosal Resection/adverse effects , Endoscopic Mucosal Resection/methods , Humans
2.
Clin Endosc ; 54(4): 603-607, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33434963

ABSTRACT

Endoscopic ultrasonography-guided gastroenterostomy using a lumen-apposing metal stent has emerged as a novel technique in the palliative treatment of malignant gastric outlet obstruction. Endoscopic ultrasonography-guided gastroenterostomy seems to have the potential to provide long-lasting patency in a minimally invasive manner. Low reintervention rates have been described. We report two cases with early lumen-apposing metal stent dysfunction, compromising patency. One case showed food impaction after three weeks, and hyperplastic tissue overgrowth with a buried distal flange six weeks after stent placement. The latter was successfully treated by argon plasma coagulation, stent removal, and deployment of a larger-diameter lumen-apposing metal stent. The second case showed a narrowed luminal diameter of the stent and jejunal pressure ulcerations after three weeks. The narrowing was successfully treated by balloon dilation. Eight weeks later, hyperplastic tissue overgrowth at the distal flange of the stent and a gastro-colonic fistula were diagnosed, followed by extensive reconstructive surgery.

SELECTION OF CITATIONS
SEARCH DETAIL
...