Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
1.
3D Print Med ; 9(1): 16, 2023 Jun 09.
Article in English | MEDLINE | ID: mdl-37294496

ABSTRACT

Custom-made triflange acetabular implants are increasingly used in complex revision surgery where supporting bone stock is diminished. In most cases these triflange cups induce stress-shielding. A new concept for the triflange is introduced that uses deformable porous titanium to redirect forces from the acetabular rim to the bone stock behind the implant and thereby reduces further stress-shielding. This concept is tested for deformability and primary stability.Three different designs of highly porous titanium cylinders were tested under compression to determine their mechanical properties. The most promising design was used to design five acetabular implants either by incorporating a deformable layer at the back of the implant or by adding a separate generic deformable mesh behind the implant. All implants were inserted into sawbones with acetabular defects followed by a cyclic compression test of 1800N for 1000 cycles.The design with a cell size of 4 mm and 0.2 mm strut thickness performed the best and was applied for the design of the acetabular implants. An immediate primary fixation was realized in all three implants with an incorporated deformable layer. One of the two implants with a separate deformable mesh needed fixation with screws. Cyclic tests revealed an average additional implant subsidence of 0.25 mm that occurred in the first 1000 cycles with minimal further subsidence thereafter.It is possible to realize primary implant fixation and stability in simulated large acetabular revision surgery using a deformable titanium layer behind the cup. Additional research is needed for further implementation of such implants in the clinic.

2.
ACS Biomater Sci Eng ; 6(10): 5486-5492, 2020 10 12.
Article in English | MEDLINE | ID: mdl-33320546

ABSTRACT

The complex reconstructive surgeries for which patient-specific orthopedic, maxillofacial, or dental implants are used often necessitate wounds that are open for a considerable amount of time. Unsurprisingly, this allows bacteria to establish implant-associated infection, despite the scrupulous sterilization efforts made during surgery. Here, we developed a prophylactic bactericidal coating via electrophoretic deposition technology for two 3D-printed porous titanium implant designs. The surface characteristics, antibiotic release behavior, antibacterial properties, and impact on osteoblast cell proliferation of the optimized coatings were investigated. The results unequivocally confirmed the biofunctionality of the implants in vitro. This study reveals a new avenue for future antibacterial patient-specific implants.


Subject(s)
Anti-Infective Agents , Coated Materials, Biocompatible , Anti-Bacterial Agents/pharmacology , Humans , Prostheses and Implants , Titanium
3.
Antimicrob Resist Infect Control ; 9(1): 121, 2020 07 31.
Article in English | MEDLINE | ID: mdl-32736656

ABSTRACT

BACKGROUND: Widespread use and misuse of antibiotics have led to a dramatic increase in the emergence of antibiotic resistant bacteria, while the discovery and development of new antibiotics is declining. This has made certain implant-associated infections such as periprosthetic joint infections, where a biofilm is formed, very difficult to treat. Alternative treatment modalities are needed to treat these types of infections in the future. One candidate that has been used extensively in the past, is the use of ionizing radiation. This review aims to provide a historical overview and future perspective of radiation therapy in infectious diseases with a focus on orthopedic infections. METHODS: A systematic search strategy was designed to select studies that used radiation as treatment for bacterial or fungal infections. A total of 216 potentially relevant full-text publications were independently reviewed, of which 182 focused on external radiation and 34 on internal radiation. Due to the large number of studies, several topics were chosen. The main advantages, disadvantages, limitations, and implications of radiation treatment for infections were discussed. RESULTS: In the pre-antibiotic era, high mortality rates were seen in different infections such as pneumonia, gas gangrene and otitis media. In some cases, external radiation therapy decreased the mortality significantly but long-term follow-up of the patients was often not performed so long term radiation effects, as well as potential increased risk of malignancies could not be investigated. Internal radiation using alpha and beta emitting radionuclides show great promise in treating fungal and bacterial infections when combined with selective targeting through antibodies, thus minimizing possible collateral damage to healthy tissue. CONCLUSION: The novel prospects of radiation treatment strategies against planktonic and biofilm-related microbial infections seem feasible and are worth investigating further. However, potential risks involving radiation treatment must be considered in each individual patient.


Subject(s)
Bacteria/radiation effects , Bacterial Infections/radiotherapy , Biofilms/radiation effects , Radiation, Ionizing , Anti-Bacterial Agents/adverse effects , Bacterial Infections/microbiology , History, 19th Century , History, 20th Century , History, 21st Century , Humans , Radiotherapy/history , Radiotherapy/trends
4.
J Control Release ; 326: 38-52, 2020 10 10.
Article in English | MEDLINE | ID: mdl-32580041

ABSTRACT

The occurrence of an implant-associated infection (IAI) with the formation of a persisting bacterial biofilm remains a major risk following orthopedic biomaterial implantation. Yet, progress in the fabrication of tunable and durable implant coatings with sufficient bactericidal activity to prevent IAI has been limited. Here, an electrospun composite coating was optimized for the combinatorial and sustained delivery of antibiotics. Antibiotics-laden poly(ε-caprolactone) (PCL) and poly`1q`(lactic-co glycolic acid) (PLGA) nanofibers were electrospun onto lattice structured titanium (Ti) implants. In order to achieve tunable and independent delivery of vancomycin (Van) and rifampicin (Rif), we investigated the influence of the specific drug-polymer interaction and the nanofiber coating composition on the drug release profile and durability of the polymer-Ti interface. We found that a bi-layered nanofiber structure, produced by electrospinning of an inner layer of [PCL/Van] and an outer layer of [PLGA/Rif], yielded the optimal combinatorial drug release profile. This resulted in markedly enhanced bactericidal activity against planktonic and adherent Staphylococcus aureus for 6 weeks as compared to single drug delivery. Moreover, after 6 weeks, synergistic bacterial killing was observed as a result of sustained Van and Rif release. The application of a nanofiber-filled lattice structure successfully prevented the delamination of the multi-layer coating after press-fit cadaveric bone implantation. This new lattice design, in conjunction with the multi-layer nanofiber structure, can be applied to develop tunable and durable coatings for various metallic implantable devices. This is particularly appealing to tune the release of multiple antimicrobial agents over a period of weeks to prevent early and delayed onset IAI.


Subject(s)
Pharmaceutical Preparations , Staphylococcal Infections , Anti-Bacterial Agents , Humans , Staphylococcus aureus , Vancomycin
5.
PLoS One ; 15(5): e0233086, 2020.
Article in English | MEDLINE | ID: mdl-32407350

ABSTRACT

BACKGROUND: Implant associated infections such as periprosthetic joint infections are difficult to treat as the bacteria form a biofilm on the prosthetic material. This biofilm complicates surgical and antibiotic treatment. With rising antibiotic resistance, alternative treatment options are needed to treat these infections in the future. The aim of this article is to provide proof-of-principle data required for further development of radioimmunotherapy for non-invasive treatment of implant associated infections. METHODS: Planktonic cells and biofilms of Methicillin-resistant staphylococcus aureus are grown and treated with radioimmunotherapy. The monoclonal antibodies used, target wall teichoic acids that are cell and biofilm specific. Three different radionuclides in different doses were used. Viability and metabolic activity of the bacterial cells and biofilms were measured by CFU dilution and XTT reduction. RESULTS: Alpha-RIT with Bismuth-213 showed significant and dose dependent killing in both planktonic MRSA and biofilm. When planktonic bacteria were treated with 370 kBq of 213Bi-RIT 99% of the bacteria were killed. Complete killing of the bacteria in the biofilm was seen at 185 kBq. Beta-RIT with Lutetium-177 and Actinium-225 showed little to no significant killing. CONCLUSION: Our results demonstrate the ability of specific antibodies loaded with an alpha-emitter Bismuth-213 to selectively kill staphylococcus aureus cells in vitro in both planktonic and biofilm state. RIT could therefore be a potentially alternative treatment modality against planktonic and biofilm-related microbial infections.


Subject(s)
Methicillin-Resistant Staphylococcus aureus , Prosthesis-Related Infections/radiotherapy , Radioimmunotherapy , Staphylococcal Infections/radiotherapy , Actinium/therapeutic use , Antibodies, Monoclonal/therapeutic use , Biofilms/growth & development , Biofilms/radiation effects , Bismuth/therapeutic use , Humans , In Vitro Techniques , Lutetium/therapeutic use , Methicillin-Resistant Staphylococcus aureus/immunology , Methicillin-Resistant Staphylococcus aureus/radiation effects , Plankton/growth & development , Plankton/radiation effects , Proof of Concept Study , Radioisotopes/therapeutic use , Teichoic Acids/immunology
6.
Data Brief ; 21: 1642-1648, 2018 Dec.
Article in English | MEDLINE | ID: mdl-30505893

ABSTRACT

A model is needed to study the effectiveness of different anti-bacterial coatings on complex metal implants in a bone environment. This article shares data on the design of porous titanium implants for intramedullary implantation in the proximal rat tibia. The implant length, diameter and porosity were optimized after testing on cadaveric specimens. This article shares data on which parameters are critical to establish a chronic implant infection in Sprague Dawley rats when using the new implant design. To this end, different strains of Staphylococcus aureus and inoculation doses were investigated.

7.
Acta Biomater ; 81: 315-327, 2018 11.
Article in English | MEDLINE | ID: mdl-30268917

ABSTRACT

Implant-associated infections (IAI) are often recurrent, expensive to treat, and associated with high rates of morbidity, if not mortality. We biofunctionalized the surface of additively manufactured volume-porous titanium implants using electrophoretic deposition (EPD) as a way to eliminate the peri-operative bacterial load and prevent IAI. Chitosan-based (Ch) coatings were incorporated with different concentrations of silver (Ag) nanoparticles or vancomycin. A full-scale in vitro and in vivo study was then performed to evaluate the antibacterial, immunogenic, and osteogenic activity of the developed implants. In vitro, Ch + vancomycin or Ch + Ag coatings completely eliminated, or reduced the number of planktonic and adherent Staphylococcus aureus by up to 4 orders of magnitude, respectively. In an in vivo tibia intramedullary implant model, Ch + Ag coatings caused no adverse immune or bone response under aseptic conditions. Following Staphylococcus aureus inoculation, Ch + vancomycin coatings reduced the implant infection rate as compared to chitosan-only coatings. Ch + Ag implants did not demonstrate antibacterial effects in vivo and even aggravated infection-mediated bone remodeling including increased osteoclast formation and inflammation-induced new bone formation. As an explanation for the poor antibacterial activity of Ch + Ag implants, it was found that antibacterial Ag concentrations were cytotoxic for neutrophils, and that non-toxic Ag concentrations diminished their phagocytic activity. This study shows the potential of EPD coating to biofunctionalize porous titanium implants with different antibacterial agents. Using this method, Ag-based coatings seem inferior to antibiotic coatings, as their adverse effects on the normal immune response could cancel the direct antibacterial effects of Ag nanoparticles. STATEMENT OF SIGNIFICANCE: Implant-associated infections (IAI) are a clinical, societal, and economical burden. Surface biofunctionalization approaches can render complex metal implants with strong local antibacterial action. The antibacterial effects of inorganic materials such as silver nanoparticles (Ag NPs) are often highlighted under very confined conditions in vitro. As a novelty, this study also reports the antibacterial, immunogenic, and osteogenic activity of Ag NP-coated additively-manufactured titanium in vivo. Importantly, it was found that the developed coatings could impair the normal function of neutrophils, the most important phagocytic cells protecting us from IAI. Not surprisingly, the Ag NP-based coatings were outperformed by an antibiotic-based coating. This emphasizes the importance of also targeting implant immune-modulatory functions in future coating strategies against IAI.


Subject(s)
Anti-Bacterial Agents , Coated Materials, Biocompatible , Prostheses and Implants , Silver , Staphylococcus aureus/growth & development , Titanium , Vancomycin , Animals , Anti-Bacterial Agents/chemistry , Anti-Bacterial Agents/pharmacology , Coated Materials, Biocompatible/chemistry , Coated Materials, Biocompatible/pharmacology , Male , Materials Testing , Osteogenesis/drug effects , Rats , Rats, Sprague-Dawley , Silver/chemistry , Silver/pharmacology , Titanium/chemistry , Titanium/pharmacology , Vancomycin/chemistry , Vancomycin/pharmacology
8.
Skeletal Radiol ; 47(8): 1099-1109, 2018 Aug.
Article in English | MEDLINE | ID: mdl-29388037

ABSTRACT

OBJECTIVE: Pseudotumors, a well-known complication of metal-on-metal total hip arthroplasty (MoM THA), are well identified on metal artifact-reducing sequences magnetic resonance imaging (MARS-MRI). Several MRI grading systems are described in the orthopedic literature, but their validity is unknown in large clinical studies. Our study was undertaken to describe the classification of pseudotumors in a preselected cohort divided into high- and low-risk patients, using three pseudotumor grading systems applied on MARS-MRI, and to determine the interobserver reliability of the grading systems. PATIENTS AND METHODS: A retrospective study was performed on 377 consecutive patients (240 MRI scans) treated with an M2a-38 and Taperloc stem combination (Biomet, Warsaw, IN, USA). Patients were divided into a high-risk and a low-risk group based on previous published risk factors. Two observers determined the presence of pseudotumors using three different pseudotumor grading systems for classifying MARS-MRI results. RESULTS: The prevalence of pseudotumors as determined with MARS-MRI was 59% in our high-risk group, 0% in the low-risk group and 43% in the control group. Serum cobalt values were increased in the high-risk group. The kappa values of the Anderson, Hauptfleisch and Matthies grading system scores were 0.43, 0.44, and 0.49 respectively. CONCLUSIONS: High-risk patients are at a high risk for pseudotumor development. No pseudotumor development was found in low-risk patients. Interobserver reliability scored best with the Matthies system, but all three grading systems showed only a moderate agreement.


Subject(s)
Arthroplasty, Replacement, Hip , Granuloma, Plasma Cell/diagnostic imaging , Hip Prosthesis/adverse effects , Magnetic Resonance Imaging , Metal-on-Metal Joint Prostheses/adverse effects , Female , Granuloma, Plasma Cell/etiology , Humans , Male , Middle Aged , Observer Variation , Prosthesis Design , Reproducibility of Results , Retrospective Studies , Risk
9.
Arch Orthop Trauma Surg ; 128(10): 1065-72, 2008 Oct.
Article in English | MEDLINE | ID: mdl-18058112

ABSTRACT

INTRODUCTION: In a consecutive series of 64 patients with an ABG-II stem, we analyzed whether the tightness of the fit of the prosthesis affected bone remodeling and if there was a relation between clinical and radiological results. MATERIALS AND METHODS: Radiographic analysis of bone remodeling in different Gruen zones was done. Bone density changes were graded as present or absent in the AP and lateral radiographs as compared with the previous sets of radiographs. Bone remodeling was compared to literature values of the ABG-I stem. Three stem levels were defined. The proximal level was set at the upper border of the lesser trochanter, the mid-stem level at halfway the stem and the distal level 1 cm above the tip of the prosthesis. Femoral fit was defined as tight when the ratio of the fit was >/=0.8 and as non-tight if the fit was <0.8. The incidence of thigh pain was scored using the Merle d'Aubigne (MdA) hip score. RESULTS: Proximal bone resorption in Gruen zone 1 was 26.6% and in zone 7, 34.4% compared to 48 and 45% for the ABG-I stem after 5 years. No correlation was found between femoral fit and radiological changes. Proximal and distal fit was significantly lower for patients with thigh pain than without thigh pain. Patients with a non-tight proximal fit produced significantly more varus (17/30 = 56.7%) than patients with a tight proximal fit (2/34 = 5.9%; P < 0.01). CONCLUSION: Femoral fit in ABG-II does not predict certain radiological changes, but less proximal bone resorption confirms the design changes from ABG-I to ABG-II. A non-tight proximal fit is correlated with varus position of the stem. Thigh pain is correlated with a poor fit and fill of the femoral stem.


Subject(s)
Arthroplasty, Replacement, Hip , Bone Remodeling , Hip Prosthesis , Joint Diseases/diagnostic imaging , Joint Diseases/surgery , Adult , Aged , Aged, 80 and over , Bone Resorption/diagnostic imaging , Bone Resorption/surgery , Female , Femur , Follow-Up Studies , Hip Joint/diagnostic imaging , Hip Joint/surgery , Humans , Male , Middle Aged , Radiography , Retrospective Studies , Treatment Outcome
10.
Hip Int ; 16(1): 8-17, 2006.
Article in English | MEDLINE | ID: mdl-19219772

ABSTRACT

UNLABELLED: Proximal bone resorption and an increased fracture rate in the ABG-I stem has been shown. For these reasons the ABG-I stem design was changed to the ABG-II. In this study periprosthetic bone loss around the ABG-I vs ABG-II is compared to verify if the design changes resulted in improved proximal bone preservation. METHODS: 51 patients were randomised to either the ABG-I or ABG-II hip prosthesis. Periprosthetic BMD change at various time points was measured using DEXA. Between the two groups (age, gender, weight etc.) no statistical difference was encountered. Compared to the baseline at two years the ABG-II preserved bone better proximally (e.g. zone 7: ABG-II: -3.7%, ABG-I: -11.9%, p=0.05) than the ABG-I. Distally, the trend was opposite and less bone loss was measured for the ABG-I than the ABG-II in zones 3, 4 and 5 (n.s.). CONCLUSION: this study confirms the philosophy behind the design changes from the ABG-I to ABG-II stem where increased elasticity, more proximal HA-coating, a shorter and distally polished stem, were meant to reduce proximal bone resorption. In future this may lead to fewer periprosthetic fractures and to less complicated revision surgery.

11.
Int Orthop ; 29(4): 235-40, 2005 Aug.
Article in English | MEDLINE | ID: mdl-15928913

ABSTRACT

We studied 14 periprosthetic femoral fractures out of a series of 619 hydroxyapatite coated hip implants and compared the outcome to published treatment algorithms using the Vancouver classification. There were five type A fractures, six B1, two B2, and one type B3 fracture. All but one type A fractures were treated conservatively. Compared with the Vancouver classification, we observed a different fracture type in the type B fractures. No fractures at the tip of the stem were seen, as in cemented implants. Three B1 fractures were treated operatively due to fracture displacement, and three were treated conservatively. The B2 and B3 fractures were managed with long, uncemented, revision stems because of a disrupted bone-prosthesis interface. All fractures healed well. This study confirms that the modified algorithm of management of periprosthetic fractures, using the Vancouver classification, is a simple, reproducible, classification system for uncemented prostheses. Conservative treatment is a valid option if the implant is stable whilst surgical intervention is mandatory if the implant is loose.


Subject(s)
Arthroplasty, Replacement, Hip/adverse effects , Femoral Fractures/etiology , Hip Prosthesis/adverse effects , Prosthesis Failure , Aged , Aged, 80 and over , Algorithms , Coated Materials, Biocompatible/adverse effects , Durapatite/adverse effects , Female , Humans , Male , Middle Aged
12.
Cardiovasc Intervent Radiol ; 26(2): 111-7, 2003.
Article in English | MEDLINE | ID: mdl-12616414

ABSTRACT

The purpose of this study was to determine whether transcatheter arterial chemoembolization (TACE) protocol affects the total volume of chemotherapy injected into the liver as well as subsequent arterial patency. A total of 160 patients with primary or secondary liver cancer were treated with 3 different chemoembolization protocols at a single institution. Data were analyzed retrospectively. Group 1 (n = 36) consisted of slurry of chemotherapy, oil and polyvinyl alcohol particles (PVA), group 2 (n = 91), chemotherapy and oil followed by PVA, and group 3 (n = 33), chemotherapy and oil followed by Gelfoam pledgets. The total volume of chemotherapy injected into the liver was recorded. Arterial patency was determined during subsequent chemoembolizations. The mean percentage of total intended chemotherapy dose administered was 54.6% for group 1, 75.3% for group 2, and 80.6% for group 3. Arterial patency at follow-up angiography was 56% for group 1, 74% for group 2, and 81% for group 3. The slurry protocol (group 1) significantly reduced arterial patency and injectable volume of chemotherapy during TACE.


Subject(s)
Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Chemoembolization, Therapeutic/instrumentation , Hepatic Artery/pathology , Hepatic Artery/surgery , Liver Neoplasms/therapy , Angiography, Digital Subtraction , Antibiotics, Antineoplastic/administration & dosage , Antineoplastic Agents/administration & dosage , Catheters, Indwelling , Cisplatin/administration & dosage , Contrast Media/administration & dosage , Dose-Response Relationship, Drug , Doxorubicin/administration & dosage , Follow-Up Studies , Gelatin Sponge, Absorbable/administration & dosage , Hemostatics/administration & dosage , Hepatic Artery/diagnostic imaging , Humans , Injections, Intra-Arterial , Iodized Oil/administration & dosage , Liver Neoplasms/physiopathology , Maryland , Middle Aged , Mitomycin/administration & dosage , Polyvinyl Alcohol/administration & dosage , Treatment Outcome , Vascular Patency/drug effects
13.
Eur J Surg Oncol ; 28(5): 481-9, 2002 Aug.
Article in English | MEDLINE | ID: mdl-12217299

ABSTRACT

AIMS: Presence of axillary lymph node metastases is considered the most important prognostic factor for breast cancer survival. In a period of increasing popularity for the sentinel node procedure, clarity about the possible relation between axillary dissection and survival is essential. This study investigated whether the total number of removed lymph nodes and the ratio of invaded/removed lymph nodes (lymph node ratio (LNR) would prove to be independent prognostic factors for survival. METHODS: Data from 453 consecutive patients with stage I or II breast cancer were studied retrospectively. The total number of removed lymph nodes and the LNR were analysed for their prognostic value in comparison with known prognostic factors. RESULTS: Node-negative patients with < 14 lymph nodes removed had a 10 year survival of 79% compared with 89% in patients with > or = 14 lymph nodes removed (P=0.005). The 10 year survival for patients with an LNR > or = 0.2 was 52%, compared with 73% for patients with an LNR < 0.2 (P<0.0001). A Cox proportional hazards model showed that, for node-negative patients, only age and total number of removed lymph nodes were significant prognostic factors. For node-positive patients, age, total number of removed lymph nodes and the LNR were significant risk factors for survival outcome. The LNR was also significantly associated with the presence of distant metastases during follow-up (hazard ratio 3.56, range 1.63-7.77). CONCLUSIONS: In stage I and II breast cancer, a favourable prognosis was found for node-negative patients with > or = 14 removed lymph nodes. Before axillary lymph node dissection with its well-defined survival prognosis is replaced by less invasive staging methods, long-term survival using new staging techniques needs to be defined. For node-positive patients, the LNR proved to be an excellent predictor for survival outcome or development of metastatic disease. Selection of lymph node-positive patients based on the LNR may guide specific adjuvant treatment choices.


Subject(s)
Lymph Nodes/pathology , Lymph Nodes/surgery , Aged , Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Axilla , Breast Neoplasms/diagnosis , Breast Neoplasms/therapy , Carcinoma, Ductal, Breast/diagnosis , Carcinoma, Ductal, Breast/therapy , Carcinoma, Lobular/diagnosis , Carcinoma, Lobular/therapy , Female , Follow-Up Studies , Humans , Lymph Node Excision , Lymph Nodes/diagnostic imaging , Mammography , Mastectomy, Radical , Middle Aged , Multivariate Analysis , Neoplasm Metastasis , Neoplasm Staging , Netherlands , Predictive Value of Tests , Prognosis , Radiotherapy, Adjuvant , Survival Analysis , Tamoxifen/therapeutic use , Time Factors , Treatment Outcome , Women's Health
SELECTION OF CITATIONS